HomeMy WebLinkAboutEvaluation Report - Roofing Underlayments CREEK Certificate of Authorization bur 29824 17520 Edinburgh Drive Tampa, FL 33647 Ij TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 7T"EDITION(2020) Manufacturer: BEACON SALES ACQUISITIONS, INC. Issued October 18, 2020 c/o OWENS CORNING ROOFING AND ASPHALT LLC 1 Owens Corning Parkway Toledo, OH 43657 (800)438-7465 Quality Assurance: Intertek Testing Services NA, Inc. (QUA1673) SCOPE Category: Roofing Subcategory: Underlayments Code Edition: Florida Building Code, 7"' Edition (2020)including High-Velocity Hurricane Zones (HVHZ) Code Sections: 1507.1.1, 1518.4 Properties: Physical properties REFERENCES Entity Report No. Standard Year Intertek Testing Services NA Ltd.(TST1509) 102389161 COQ-002A AC 188 2012 Intertek Testing Services NA Ltd.(TST1509) 102389161 COQ-004 ASTM D 226 2009 PRI Construction Materials Technologies(TST5878) OCR-259-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) 1378TO127 ASTM D 4533 2015 ASTM D 5035 2011(2019) ASTM D 751 2019 PRODUCT DESCRIPTION Beacon Tri-Built A mechanically attached, synthetic underlayment for use in steep slope roofing applications as an alternative to ASTM D 226, Type I or Type II felt that has demonstrated a minimum tear strength per ASTM D 4533 of 15 pounds, a minimum tensile strength per ASTM D 5035 of 20 pounds/inch, and meets liquid water transmission test of Section 8.6 of ASTM D 4869. OCR17002.3 FL22259-R3 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 G R E E K OWENS CORNING ROOFING AND ASPHALT LLC Beacon Tri-Built TECHNICAL SERVICES, LLC APPLICATION Unless otherwise noted, the following application details shall be followed for New and Existing construction. See manufacturer's installation instructions for further detail. Roof Deck: The roof deck shall be constructed of closely fitted wood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than '/8"gap at abutting joints. Attachment method Underlayment shall be attached in accordance with the FBC Section 1507.1.1, (Non-HVHZ): Table 1507.1.1.1 and manufacturer's installation instructions. Attachment method Underlayment shall be installed with a minimum 4-inch head lap and minimum 6-inch (HVHZ): end lap and be fastened as specified in FBC Section 1518.2. Allowable roof coverings Mechanically attached roof systems as prescribed in FBC Table 1507.1.1.1. (Non-HVHZ): Allowable roof coverings Underlayment shall be used with mechanically attached asphalt shingles. (HVHZ): LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 5) Roof slope limitations shall be in accordance with FBC requirements. 6) The underlayment may be used as described in other current FBC product approval documents. 7) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 8) The underlayment shall not be installed over existing roof coverings. 9) The underlayment shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. The first layer shall cover the entire bottom edge of the deck. End laps shall be staggered a minimum of 72-inches from the preceding course. 10) The underlayment shall be exposed on the roof deck for a maximum duration of 30 days. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. OCR17002.3 FL22259-R3 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 G R E E K OWENS CORNING ROOFING AND ASPHALT LLC Beacon Tri-Built TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 7`h Edition (2020) including High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. 11%JYIIR��11���, 2020. 10.18 �,. �.••. �ENs� . s •,: �� 11 :45:25 ti. . � , No 74021 _� � Digitally signetl by ZecM1ary R.Prieat = -04'00' �-33' STATE OF 1JJ '��'�•'•A, p?:•'�� � Zachary R. Priest, P.E. R `• G��� Florida Registration No. 74021 4'���S�ONA�� ``� Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR17002.3 FL22259-R3 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.