HomeMy WebLinkAbout4006 Eng Certification 2021-22-12CIVIL, STRUCTURAL & WATER RESOURCE ENGINEERING 3370 Capital Circle NE Suite J, Tallahassee, FL 32308 │ 850-894-4521 │ fax 850-224-0505 Ebbstone.com December 22, 2021 Mr. David Johnson Chief Building Inspector St. Lucie County Planning & Developmental Services RE: Engineering Certification for 4006 Avenue P Fort Pierce, Florida 34947 House Repair Plans Permit Number 1912-0389 Per your request, the following certification is submitted: ENGINEER’S CERTIFICATION This letter and the information contained within have been prepared solely for the use of St. Lucie County Planning & Developmental Services . This letter is based solely upon the information made available to or gathered by Jacques Registe, P.E.. I do not assume responsibility for unforeseen conditions, or conditions not recognized as unacceptable at the time this letter was prepared. This letter is based solely on the visual inspection of the structure and no testing of materials was performed. I prepare this letter, and make the following conclusion in a manner consistent with sound practices, level of care, and the skills normally exercised by members of the engineering profession operating under similar circumstances. This letter and the discussion contained herein shall not, in whole or in part, be disseminated or conveyed to any other party or used or relied upon by any other party, in whole or in part, without prior written consent. I, Jacques Registe, P.E. , hereby state that this letter is, to the best of my knowledge and belief, true and correct and represents the described work in accordance with current established engineering practices. I hereby certify that I am a Licensed Professional Engineer in the State of Florida practicing with Ebbstone, Inc.. I have supervised and performed some of the work for the referenced house. All four floor joists that were added were properly installed and tied own per the building codes. The existing floor joists were tied down and are structurally adequate to carry the load. The addition plywood that was installed on the floor would not adversely impact the structural integrity of the house. The bottom sheeting installed to the floor joists provide additional strength to the structure. The drop down plywood to cover the plumbing is purely aesthetic and was installed to not adversely impacted the structure. I also certified that the bottom 2' of the right side of the exiting siding was replaced with hardie panels according to FL13223_R1_II_Install FL product approval. I certified that the all the repair work was built in accordance with the latest Florida Building Codes and the revised design plans prepared by me and submitted on July 22, 2020. I also certified that I am leaving in the house and do not intend to sell in the near future. Sincerely, Ebbstone, Inc. COA 9292 Jacques Registe, P.E. Chief Engineer Florida PE # 43397