Loading...
HomeMy WebLinkAboutEric Cendejas 11.22kw (1) SCOPE OF WORK: GOVERNING CODES a TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE SYSTEM RATING +. LOCATED AT 7802 LOCKWOOD DR FORT PIERCE, FL 34951. 2018 NFPA 1 (FIRE CODE) 11.22 KWDC THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY 2017 NATIONAL ELECTRICAL CODE GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. 2020 FLORIDA BUILDING CODE (7TH EDITION) 7.92 KWAC ATLANTIC KEYENERGY�LLC THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES 7006 STAPOINT CT AUTHORITY HAVING JURISDICTION (AHJ): SAINT LUCIE COUNTY STE B WINTER EQUIPMENT SUMMARY PARK,FL 32792 SHEET INDEX +1 (407)988-0273 33 Q.PEAK DUO BLK-G6 340 MODULES PV 0 COVER PAGE 33 ENPHASE IQ7-60-2-US MICROINVERTERS PV 1 STRING LAYOUT&BOM REVISIONS PV-2 ELECTRICAL LINE DIAGRAM&CALCS. DESCRIPTION DATE REV GENERAL NOTES: WIRING AND CONDUIT NOTES: PV-3 SPECIFICATIONS&SIGNAGE • THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND . ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PV 4+ EQUIPMENT SPECIFICATIONS OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE PURPOSE AND APPROVED FOR THE SITE APPLICATIONS MODIFICATIONS IN CONSTRUCTION DETAILS. • ALL PV CABLES AND HOMERUN WIRES BE#10AWG'USE-2, PV • ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY Ml INSTALLATION OF ANY EQUIPMENT AT SITE. OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER • CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL PROJECT SITE BOXES AS REQUIRED Signature with Seal PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. . ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED • CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS ACCORDING TO [NEC 690.8 (A)(1)& (13)(1)], [NEC 2401 [NEC AND EXISTING CONDITIONS.ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER 690.71 FOR MULTIPLE CONDUCTORS BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION • ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT AND ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE SHALL BE DERATED ACCORDING TO [NEC TABLE 310.15 f� CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL (13)(2)(C)] BLACK Ol COMPENSATION. • EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 9l . r • DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, RATED, WET AND UV RESISTANT,AND UL LISTED RATED FOR , �� � DATE:12/16/2021 FLOORS, ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE ROTE, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT CONTRACTOR AT NO ADDITIONAL COST. PROJECT NAME&ADDRESS i • THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND WIRE FROM SHARP EDGES COMPLETION OF THE WORK WITH APPROVED MATERIALS. • 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH i t , • NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR ARCHITECT. IDENTIFIED BY OTHER EFFECTIVE MEANS t • CONTRACTOR SHALL OBTAIN BUILDING PERMIT. NO WORK TO START UNLESS BUILDING • ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION PERMIT IS PROPERLY DISPLAYED. + r� • ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE • VOLTAGE DROP LIMITED TO 2% O WITH THE REQUIREMENTS OF THE FL BUILDING CODE, THE DEPARTMENT OF NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE _ ry I c� ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. COLOR CODED AS FOLLOWS: DC POSITIVE- RED (OR MARKED ti' O • IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL RED), DC NEGATIVE-GREY(OR MARKED GREY) Q -c— PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR PV_0 HOUSE PHOTO SCALE:NTS � w J CV > U O , THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. CODED: DC POSITIVE-GREY(OR MARKED GREY), DC 0 O rn NEGATIVE- BLACK(OR MARKED BLACK) z LLj I cn • ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO • AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE z W Y U �j BE PAINTED BY GENERAL CONTRACTOR. A OR L1- BLACK, PHASE B OR L2 RED, PHASE C OR L3- BLUE, W U ti • THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE NEUTRAL-WHITE/GRAY U 750 LL ~ c LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. Y W J 0 W • THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, No ~ L CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. ao = N • CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK. Printed copies of this document are not considered signed W ti 0 —_ and seal,and all SHA-1 authentication code must be verified C6 ELECTRICAL NOTES: on any electronic copies E • THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE INSTALLED ONLY BY QUALIFIED PEOPLE. A QUALIFIED PERSON IS ,�"h0pippo" Omar R W ONE WHO HAS SKILLS AND KNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OF THE ELECTRICAL EQUIPMENT AND INSTALLATIONS ,�`` R filq'f.," AND HAS RECEIVED SAFETY TRAINING TO RECOGNIZE AND AVOID THE HAZARDS INVOLVED. (NEC 690.4(C), NEC 2017) �c "'+ • LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. FOR A LINE SIDE TAP ;O.` , 4= Ti rado CONNECTION, UTILITY NEEDS TO BE NOTIFIED WELL IN ADVANCE TO COORDINATE BUILDING ELECTRICAL SHUT OFF. 2021 •12.16 • NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC. SUBCONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONS AND THE -�' - COORDINATION REQUIREMENTS OF OTHER TRADES. :0 . :T.r. r SHEET NAME _ ? • ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TO QUALIFIED PERSONNEL. 13:40:15 COVER PAGE • ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WATERTIGHT AND APPROVED FOR USE IN WET LOCATIONS. (NEC 690), NEC 2017. "`"��ONNt ' `'� • WIRING METHODS FOR PV SYSTEM CONDUCTORS Al PERMITTED WITHIN 10 IN. OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE LOCATED rrrr,+r"0��j555 _051001 DIRECTLY BELOW THE ROOF SURFACE THAT'S COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT WIRING SHEET SIZE • BACK-FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. ANSI B • ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARE LISTED AS UV RESISTANT. • CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS IN NEC 690 11" X 17" • PV SOURCE, OUTPUT AND INVERTER CIRCUITS SHALL BE IDENTIFIED AT ALL POINTS OF TERMINATION, CONNECTION, AND SPLICES. THE MEANS OF ID SHEET NUMBER CAN BE SEPARATE COLOR CODING, MARKING TAPE, TAGGING ETC. (NEC 690.4), NEC 2017. • MEASURE THE LINE-TO-LINE AND LINE-TO-NEUTRAL VOLTAGE OF ALL SERVICE ENTRANCE CONDUCTORS PRIOR TO INSTALLING ANY SOLAR �\V�_O EQUIPMENT. THE VOLTAGES FOR THE 240VAC RATED. BILL OF MATERIALS LEGEND JB -JUNCTION BOX _ MENERGY EQUIPMENT QTY DESCRIPTIONca -COMBINER BOX SOLAR PV MODULE 33 Q.PEAK DUO BLK-G6 340 AC DISCONNECT INVERTER 33 ENPHASE IQ7-60-2-US MAIN SERVICE PANELATLANTIC KE JUNCTION BOX 1 JUNCTION BOX, NEMA 3R, UL LISTED uM UTILITY METER 7006 STAPOINT CT COMBINER BOX 1 ENPHASE IQ COMBINER 3 W/IQ ENVOY X-IQ-AM1-240-3 --------coNDUIr STE B WINTER ( ) PARK,FL 32792 AC DISCONNECT 1 FUSED AC DISCONNECT(2)50A FUSES, 240V, NEMA 3R, UL LISTED (E) PACK OF RESIDENCE +1 (407)988-0273 ENPHASE Q CABLE 39 ENPHASE Q CABLE 240V(PER CONNECTOR) BRANCH TERMINATOR 3 BRANCH TERMINATOR REVISIONS IQ WATER TIGHT CAP 6 IQ WATER TIGHT CAPS DESCRIPTION DATE REV GROUNDING LUG 1 7 1GROUNDING LUG OOO - MODULE STRINGING 36" FIRE SETBACK Signature with seal C-8 B-8 C-9 C-7 B-7 - m -10 C-6 B-6 m DATE:12/16/2021 PROJECT NAME&ADDRESS C-5 B-5 Printed copies of this document are not considered signed and seal,and all SHA-1 authentication code must be verified C-11 on any electronic copies C-4 B-4 ,otWL'`T1 "I Omar R d9 #=; Tirado _1 o:. CO 2021 .12.16 C-2 B-2 Q co o M CO ;off .TA�oF .� 13:40:26 � , Uj Uj v o LL LL N C-1 B-1 9 / _ 0 Z W Lo to -05 00 ��/////////////�//i. a (E) UTILITY METER z LJJ Y U N .� 36 FIRE SETBACK J (E)MAIN SERVICE PANEL L1J U W -0 (N)FUSED AC DISCONNECT U (n OJ .� JB —————————————- ----- (N)ENPHASE IQ COMBINER 3 Y_ w CV 7 n N)3/4" LTNM CONDUIT oo 0A-3 A-2 A-1 r— LL = m (N)JUNCTION BOX W F�Qi� A-5 A-6 A-7 A-8 A-13 A-1 A-11 A-10 A-9 SHEET NAME STRING LAYOUT & BOM SHEET SIZE ANSI B (E) FRONT OF RESIDENCE 11" X 17" 1 ROOF PLAN WITH STRING LAYOUT & BOM LOCKWOOD DR SHEET NUMBER PV-1 PV-1 SCALE: 1/8"= 1'-0" INITIAL CONDUCTOR FINAL CONDUCTOR #OF CURRENT-CARRYING TERMINAL CONDUIT FILL CONT. MAX. BASE DERATED VOLTAGE ID TYPICAL LOCATION LOCATION CONDUCTOR CONDUIT PARALLEL CONDUCTORSIN OCPD EGC TEMP.CORR.FACTOR FACTOR CURRENT CURRENT AMP. AMP. AMP. LENGTH DROP CIRCUITS CONDUIT RATING 1 1 BRANCH 1 JUNCTION BOX 12 AWG Q CABLE 1 2 N/A 6 AWG BARE 0.76 (55°C) N/A 13.OA 16.3A N/A N/A 25A 52FT 0.64% COPPER 2 1 BRANCH 2 JUNCTION BOX 12 AWG Q CABLE 1 2 N/A 6 AWG BARE 0.76 (55°C) N/A 8.OA 10.OA N/A N/A 25A 40FT 0.25% ATLANTIC KEY ENERGY LLC COPPER 7006 STAPOINT CT BARE STE B WINTER 3 1 BRANCH 3 JUNCTION BOX 12 AWG Q CABLE 1 2 N/A 6 AWG COPPER 0.76 (55°C) N/A 12.OA 15.OA N/A N/A 25A 65FT 0.55% PARK,FL 32792 +1 (407)988-0273 4 1 JUNCTION BOX IQ COMBINER BOX 10 AWG THWN-2 COPPER MIN 0.75"DIA LTNM 3 6 20A 10 AWG THWN-2, 0.76 (55°C) 0.8 13.OA 16.3A 40A 24.3A 35A 31 FT 0.43% COPPER 5 1 IQ COMBINER BOX FUSED AC 8 AWG THWN-2 COPPER MIN 0.75"DIA LTNM 1 3 50A 10 AWG THWN-2, 0.96 (33°C) 1 33.OA 41.3A 55A 52.8A 50A 5FT 0.11% REVISIONS DISCONNECT COPPER FUSED AC DESCRIPTION DATE REV 6 1 DISCONNECT MSP 6 AWG THWN-2 COPPER MIN 0.75"DIA LTNM 1 3 N/A 0.96 (33°C) 1 33.OA 41.3A 75A 72.OA 65A 5FT 0.07% NOTE: LTNM OR EQUIVALENT TYPE CONDUIT BRANCH 1 TO UTILITY GRID Signature with Seal 13- Q.PEAK DUO BLK-G6 340 MODULES �Ll �L2 FN BI-DIRECTIONAL UTILITY O METER#ACD2011 • • • POINT OF 1-PH,3-W, 120V/240V INTERCONNECTION SUPPLY SIDE TAP a L2 N (E)MAIN BREAKER TO DATE:12/16/2021 JUNCTION BOX HOUSE 240 V, 150A/2P - 600 V, NEMA 3R, Li L N PROJECT NAME&ADDRESS AV � � Q CABLE � 2 3 UL LISTED 4 ENVOY Li L1 (E)MAIN SERVICE L L1 20A/2P 10A/15A/2P AC DISCONNECT: L L2 PANEL,200A RATED, L2 240V,FUSED Li L1 1-PH,3-W,240V BRANCH 2 20A/2P NEMA 3R,UL LISTED L L2 08- Q.PEAK DUO BLK-G6 340 MODULES �z (2)50AFUSES E L1 L1 Li L1 O Ll 20A/2P 15A/2P Lz L2 L L2 U L2 N N O -- F- c c M 1:'O L • • • �— -- -- -- Q _ c � I I N ) w 0 J N � L — 5 6 G — LLJ U 0 LI- Z 0>> w I L z w > C) ca __________ ____ (N) ENPHASE IQ 1 U U) 0 LU I--Lu AV AV COMBINER 3 #6AWG SOLID BARE COPPER __I EXISTING GROUND Y w U (X-IQ-AM1-240-3) (PPB) ELECTRODE CONDUCTOR 04 POWER PERFECT BOX w 00 Q a) BRANCH 3 (ES1PN),120/24OV, = NEMA 3X 12- Q.PEAK DUO BLK-G6 340 MODULES E Printed copies of this document are not considered signed and seal,and all SHA-1 authentication code must be verified • • • on any electronic copies rr ,,, Omar R �l ,. �a M f• SHEET NAME 9 = TIrado ELECTRICAL LINE * - 2021 .12.16 & CALCS. tram OF �►. SHEET SIZE ra Q.0= 13:40:42 (33) ENPHASE IQ7-60-2-US MICROINVERTERS fONAti ;1,�,.w`'• _OC'00' ANSI B +a„ 5 11" X 17" 1 ELECTRICAL LINE DIAGRAM SHEET NUMBER PV_2 SCALE: NTS PV-2 F6] © . © SOLAR MODULE SPECIFICATIONS Fil • • •• . • MANUFACTURER / MODEL Q.PEAK DUO BLK-G6 340 .• • • • . . • :• , , PV POWER SOURCE V M P 33.94 V ATLANTIC KEY ENERGY LLC LOAD SIDE MAY BE ENERGIZED IN ELECTRIC SYSTEM IMP 10.02A 7006 STAPOINT CT THE OPEN POSITION L STE B WINTER LABEL LOCATION: VOC 40.66 V PARK,FL 32792 LABEL LOCATION: POINT OF INTERCONNECTION +1 (407)988-0273 COMBINER BOX/EMT ENCLOSURES/ (PER CODE:NEC 2017,705.12(B) ISC 10.52 A AC DISCONNECT/MAIN SERVICE PANEL (PER CODE:NEC 2017,690.13(B)) RESPONDERTEMP. COEFF. VOC -0.27 %/K REVISIONS 7]F EMERGENCY WARNING F SOLAR 'RAPID2 WITH • '' • PTC RATING 318.35 W DESCRIPTION DATE REV • • • ' • • �•WN MODULE DIMENSION 68.50" (L) x 40.55" (W) TURN RAPID SHUTDOWN PANEL WATTAGE 340W D LABEL LOCATION: SWITCH TO THE souaE Ec Pic CONDUIT,RACEWAY,ENCLOSURES, "OFF"POSITION TO PV PANELS SHUT DOWN PV SYSTEM COMBINER BOX&AC DISCONNECT (PER CODE:NEC2017,690.31(G)(3)(4) INVERTER SPECIFICATIONS Signature with Seal LABEL LOCATION: MANUFACTURER/ MODEL EN PHASE IQ7-60-2-US [3] RAPID SHUTDOWN(AC DISCONNECT) PER CODE:NEC 690.56(C)(1)AND MAX DC SHORT CIRCUIT • NFPA 11.1.12.2.1.1.1.1 &11.12.2.1.4 CURRENT 15 A LABEL LOCATION: CONTINUOUS OUTPUT AC DISCONNECT/BREAKER/ CURRENT 1.OA (240V) POINTS OF CONNECTION (PER CODE:NEC2017,690.13(B) DATE:12/16/2021 • • • • AMBIENT TEMPERATURE SPECS PROJECT NAME&ADDRESS [4] RATED AC OUTPUT CURRENT 33A RECORD LOW TEMP 0°C NOMINALOPERATING AC VOLTAGE-11W AMBIENT TEMP (HIGH TEMP 2%) 33°C LABEL LOCATION: AC DISCONNECT CONDUIT HEIGHT 0.75 (PER CODE:NEC2017,690.53) ROOF TOP TEMP 90°C E CONDUCTOR TEMPERATURE RATE 55°C ° F5-1of LO RAPI• SHUTDOWN MODULE TEMPERATURE COEFFICIENT OF VOC -0.27 %/K Q 0 M CO OR SOLAR W UO � p Z 0 w Ln cn Ljj �. LABEL LOCATION. !LU U ti 70 RAPID SHUTDOWN(AC DISCONNECT) U (n O W Y � WJa PER CODE:NEC 690.58(C)(3) � O H Printed copies of this document are not considered signed �/ _ and seal,and all SHA-1 authentication code must be verified W O D— on any electronic copies LL "r; ""''�r•. Omar R E Tlrado 2021 .12.16 %,�� �•a*s4Q~ � SHEET NAME '•.,!ow� � ;ttiw -05 00 SPECIFICATIONS & SIGNAGE ADHESIVE FASTENED SIGNS: SHEET SIZE • ANSI Z535.4-2011 PRODUCT SAFETY SIGNS AND LABELS, PROVIDES GUIDELINES FOR SUITABLE FONT SIZES,WORDS, ANSI B COLORS,SYMBOLS,AND LOCATION REQUIREMENTS FOR LABELS. NEC 110.21(B)(1) 1 1" X 17" • THE LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED.NEC 110.21(B)(3) SHEET NUMBER • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED.VINYL SIGNS SHALL BE WEATHER RESISTANT. P /_3 IT - powered by � MECHANICAL SPECIFICATION Format 1740mm x 1030mm x 32mm(including frame) Weight 19.9kg aeomm ATLANTIC KEY ENERGY LLC Front Cover 3.2mm thermally pre-stressed glass with vaomm 7006 STAPOINT CT anti-reflection technology STE B WINTER Back Cover Composite f lm ° PARK,FL 32792 Frame Black anodised aluminium +1 (407)988-0273 Cell 6 x 20 monocrystalline Q.ANTUM solar half cells ® - - Junction box 53-101 mm x 32-60 mm x 15-18 mm Protection class IP67,with bypass diodes REVISIONS tssomm Cable 4 mm2 Solar cable;(+)>-1150 mm,(-)>-1150 mmo__b Connector Stffiubli MC4,Hanwha Q CELLS HQC4;IP68 O.M°uNno° (DMLA) DESCRIPTION DATE REV +�1-Ai D-A 40.5mmIyIBSmm . • = • ELECTRICAL CHARACTERISTICS POWER CLASS 330 335 340 345 pv magazine' pyali Tested I award tV MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC1(POWER TOLERANCE+5W/-OW) Signature with Seal '�,"old` a, �!)]7 a�m;a, Power at MPP' PMpp [W] 330 335 340 345 to Innovation Short Circuit Current' Isc [A] 10.41 10.47 10.52 10.58 B �� � VDENro.com E ID.40032587 E Open Circuit Voltage' Voc [V] 40.15 40.41 40.66 40.92 5 Current at MPP INpp [A] 9.91 9.97 10.02 10.07 ® QCELLS Voltage at MPP VMpp IV] 33.29 33.62 33.94 34.25 L He&Living Award 020 GERMAII MOST TOP BRAND PV nE�osacugm Efficiency' 9 [%] >-18.4 >>>18.7 >>>19.0 >>>19.3 POPULAR PROVIDER MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' 2 1 ace SOlar T¢Chnvagy EUROPE Power at MPP P,App [W] 247.0 250.7 254.5 258.2 I,U1Q,EE`„.IrA) 2020 E Short Circuit Current Isc [A] 8.39 8.43 8.48 8.52 DATE:12/16/2021 E Open Circuit Voltage Voc IV] 37.86 38.10 38.34 38.59 .c 2 Current at MPP lm, [A] 7.80 7.84 7.89 793 PROJECT NAME&ADDRESS Voltage at MPP VNpp IV] 31.66 31.97 32.27 32.57 'Measurement tolerances PNpp±3%;Isc;Voc±5%at STC:1000 W/ni 25±2°C,AM 1.5 according to IEC 60904-3•'800 W/m�,NMOT,spectrum AM 1.5 Q.ANTUM TECHNOLOGY:LOW LEVELISED COST OF ELECTRICITY 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE Higher yield per surface area,lower BOS costs,higher K °° -°Ce" At least 98%of nominal power dur- '��0 i F � I a power classes,and an efficiency rate of up to 19.5%. W m .mm mm.,aa,m�.m m ng first year.Thereafter max.0.54% c itB° ---------------------------"--- - I �a degradation per year.At least 93.1% too of nominal power up to 10 years.At a " INNOVATIVE ALL-WEATH ER TECHNOLOGY z °0 least 85%of nominal power up to 15 �f � I O 25 years. w --r-----r-----,----_-------- r t�J Optimal yields,whatever the weather with excellent z a U low-light and temperature behaviour. o All data within measurement toler- OL0j O O antes.Full warranties in accordance w CO Q m O fEc with the warranty terms of the zoo am am $.a woa M C'7 o m Q CELLS sales organisation of our IRRADIANCEfw/m i ENDURING HIGH PERFORMANCE D s y w C) N (B ° v m respective country. O J L6 >, y I Long-term yield security with Anti LID Technology,Anti PID g mom � � YEARS Typical module performance under low irradiance conditions in v Technology',Hot-Spot Protect and Traceable Quality Tra.QTM. 5 m°' comparisontoSTC conditions(25°C,1000w/m�. Q z 0 - 0-) TEMPERATURE COEFFICIENTS w W LLI EXTREME WEATHER RATING Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient ofVoc [%/K] -0.27 v Q�� O High-tech aluminium alloy frame,certified for Temperature Coefficient of Pm, [%/K] -0.36 Nominal Module Operating Temperature NMOT [°C] 43±3 LU Il, uu high snow(5400 Pa)and wind loads(4000 Pa). PROPERTIES FOR SYSTEM DESIGN Y LU N ® A RELIABLE INVESTMENT Maximum System Voltage Vsys IV] 1000 PV module classification Classll n/ LL C) _ '� Inclusive 12-year product warranty and 25-year Maximum Reverse Current IR [A] 20 Fire Rating based on ANSI/UL 61730 C/TYPE 2 1 LU 00 Q linear performance warranty2. [L - Max.Design Load,Push/Pull [Pa] 3600/2667 Permitted Module Temperature -40°C-+85°C o (0 ] on Continuous Duty STATE OF THE ART MODULE TECHNOLOGY o Max.Test Load,Push/Pull [Pa] 5400/4000 1%( ' Q.ANTUM DUO combines cutting edge cell separation a LU and innovative wiring with Q.ANTUM Technology. QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION to 0 �f :Ior 24< �� U 'APT test conditions accordin tolEC/TS62804-1:2015,methodB-1500V,168h VIDE QualityTested, w Ito IEC 61 :2016; /`® O-O i?dHO 2 See data sheet on rear for further information. IEC 61730730:2016. TovRn.�m..e This data sheet complies CE Horizontal 1780mm 1080mm 1208mm 673.8kg 28pallets 26pallets 32modules with DIN EN 50380. packaging 10"113'0"' Vertical 1815mm 1150mm 1220mm 683kg 28pallets 24pallets 32modules = SHEET NAME packaging 21EQUIPMENT Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product.O CELLS supplies _ solar modules in two different stacking methods,depending on the location of manufacture(modules are packed horizontally,or vertically).You can find more detailed information in the document'Packaging and Transport SPECIFICATION THE IDEAL SOLUTION FOR: Information".available from o cELLs. lo Rooftop arrays on o SHEET SIZE residential buildings Hanwha O CELLS GmbH g Sonnenallee 17-21,06766 Bitterfeld-Wolfen,Germany I TEL+49(0)3494 66 99-23444 1 FAX+49(0)3494 66 99-23000 1 EMAIL salesQq-cells.com I WEB www.q-cells.com u, ANSI B 11" X 17" Engineered in Germany OCIELLS Engineered in Germany GICELLS SHEET NUMBER PV-4 Data Sheet Enphase I 7 and I 7+ M icroin�erters WATLANTICMENERGY p Q R 7006 STAPOINT CT Enphase Microinverters STE B WINTER Region:AMERICAS INPUT DATA(DC) _ IQ7-60-2-US _IQ7PLUS-722-US PARK,FL 32792 Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ +1 (407)988-0273 Module compatibility 60-cell/120 half cell PV modules 60-cell/120 half cell and 72 only cell/144half-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V REVISIONS Operating range 16 V-46 V 16 V-60 V DESCRIPTION DATE REV Min/Max start voltage 22 VI 48 V 22 V/60 V The high-powered smart grid-ready Max DC short circuit current(moduleisc) 15A 15A Enphase Overvoltage class DC port II II Enphase IQ 7 Micro- and Enphase IQ 7+ Micro- DC port backfeed current 0A oA IQ7 and IQ 7+ dramatically Simplify the Installation process While PV array configuration 1 x1 ungrounded array;No additional❑O side protection required; achleving the highest System efficiency. AC side protection requires max 20Aper branch circuit Miero nve rters OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Signature with Seal Part of the Enphase IQ System,the IQ 7 and Peak output power 250VA 295VA Maximum continuous output power 240 VA 290 VA IQ7+MICrolnverterslntegrate with the Enphase Nominal(L L)voltage/range' 240V1 208V1 240V/ 208V/ IQ Envoy', Enphase IQ Battery'',and the Enphase 211-264V 163-229V 211-264V 183-229V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Enlighten'" monitoring and analysis software. Nominal frequency 5DHz 60 Hz IQ Series Microinverters extend the reliability Extended frequency range 47-68Hz 47-68Hz AC short circuit fault current over 3 cycles 5.8Arms 5.8 Arms Standards set forth by previous generations and Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(20B VAC) 13(240 VAC) 11 (208 VAC) Undergo over a mllllon hours of power ontesting, Overvoltage class AC port III III DATE:12/16/2021 AC port backfeed current 18 MA 1 B mA PROJECT NAME&ADDRESS enabling Enphase to provide an industry leading Power factor setting 1.0 1.0 warranty of Lip to 25 years. Power factor(adjustable) 0 85leading.. 0.35lagging 0.83 leading...0.85lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40'C t o+65'C E Easy to Install Relative humidity range 4%to 100%(condensing) � Q U Connector type MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Lf) Lightweight and simple Dimensions(HxWxD} 212 mm x 175 mm x 30.2 mm(without bracket) CO � , �C M O Faster installation with improved,lightertwo wire cabling Weight 1.08 kg(2.38lbs) Q co CO I:Built-in rapid shutdown compliant(NEC 2014&2017) Cooling Natural convection-No fars w w O _J � Co Approved for wet locations Yes Z O 0')Pollution degree PD3 0 �J J L0 U) z W U ^ Co Productive and Reliable Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Y N F Optimized for high powered 60-cell/120 half cell and 72 Environmental category/UV exposure rating NEMAType 61 outdoor �W 0 C) 0� I- _0 cell/144 half-cell*modules FEATURES U 0 More than a million hours of testing Communication Power Line Communication(PLC) Y_ W N 0 Class it double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options. ~ Both options require installation of an Enphase IQ Envoy. LL � _ UL listed Disconnecting means The AC and DC connectors have been evaluated and approved by ULfor use as the load-break W 1�_ O ILL disconnect required by NEC 690. M Smart Grid Read Compliance CA Rule 21 (UL 1741-SA) E y UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, W CAN/CSA C22.2 No.107.1-01 Complies with advanced grid support,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC frequency ride-through requirements 2017,and NEC 2020 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, Remotely updates to respond to changing for AC and OC conductors,when installed according manufacturer's instructions. grid requirements Configurable forvarying grid profiles Meets CA Rule 21(UL 1741-SA) SHEET NAME ® .No enforced Seethe compatibility calculator EQUIPMENT *The IQ7+Micro is re uiredto support 72-cell/144 half-cell modules. 2.Noninalvoltagerangecanbe extended beyondnominal ifFecluiredbytheutility. SPECIFICATION 3.Limits mayvary.Refer to local requirements to deflnethe number of microinverters per branch inyour area. SHEET SIZE E N P H A S E To leam more about Enphase offerings,visit enphase.com E N P H A S E To learn more about Enphase offerings,visit enphase.com t.J \.J C 2g2Q Enphase Energy All rights reserved Enphase,the Enphase logo,Enphase IQ 7.Enphase IQ 7+,Enphase IQ Battery, v ANSI B Enphase Enli.gheen,Enphasem IQ Envoy,and othertmdearks or service nam es are t change. he trademarks of Enphase Energy,Inc Data subject to 262D l2 11 rr 1 7" SHEET NUMBER PV-5 ATLANTIC KEYMENERGY Data Sheet Enphase IQ Combiner 3 7006 STAPOINT CT Enphase Networking STE B WINTER MODEL NUMBER PARK,FL 32792 IQ Combiner 3 IQ Combiner 3 with Enphase IQ Envoy"printed circuit board for integrated revenue grade PV +1 (407)988-0273 X-IQ-AM1-240-3 production metering(ANSI C12.20+/-0.50/6)and optional*consumption monitoring(+/-2.5%). ACCESSORIES and REPLACEMENT PARTS(not included,order separately) Enphase Mobile Connect" REVISIONS CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 DESCRIPTION DATE REV CELLMODEM-01 (3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1(4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2.5%). Enphase The Enphase IQ Combiner 3'" with Enphase CT-200-SPLIT *Consumption monitoring is required for Enphase Storage Systems IQ En consolidates interconnection Ensemble Communications Kit Installed at the IQ Envoy.For communications with Enphase Encharge'"storage and Enphase Q Combiner 3 COMMS-KIT-01 EnpowerTM smart switch.Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner- equipment into a single enclosure and and allows wireless communication with Encharge and Enpower. Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. Signature with Seal (X-IQ-AM1-240-3) streamlines PV and storage installations by BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 providing a consistent, pre-wired solution for BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 EPLC-01 Power line carrier(communication bridge pair),quantity-one pair residential applications. It offers up to four XA-SOLARSHIELD-ES Replace the default solar shield with this Ensemble Combiner Solar Shield to match the look and feel of the Enphase Enpower-smart switch and the Enphase Encharge'"storage system 2-pole input circuits and Eaton BR series XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) busbar assembly. XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS DATE:12/16/2021 Rating Continuous duty System voltage 120/240 VAC,60 Hz PROJECT NAME&ADDRESS Eaton BR series busbar rating 125 A Max.continuous current rating(output to grid) 65 A Max.fuse/circuit rating(output) 90 A Smart Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Includes IQ Envoy for communication Max.continuous current rating(input from PV) 64 A C I_ and control E Max.total branch circuit breaker rating(input) 80 A of distributed generation/95 A with IQ Envoy breaker included O Flexible networking supports Wi-Fi, LO U Envoy breaker 10A or 15A rating GE Q-line/Siemens Type QP/Eaton BR series included Ethernet,or cellular y g yP � M O O !' Optional AC receptacle available for PLC bridge Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA co LJJ C) CO M N Provides production metering and optional consumption J i I monitoring Dimensions(WxHxD) 49.5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets). w C) O LL � Supports Ensemble Communications Kit for 0 z > to PP Weight 7.5 kg(16.51bs) > LU (LS communication with Enphase Encharge'"storage and z LJJ (� ^ Enphase Enpower'"smart switch Ambient temperature range -40°C to+46°C(-40°to 115°F) w Q U ci� I- _0 Cooling Natural convection,plus heat shield U '^ O LU I n Simple Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Y vJ J EL UJ O Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors �/ 0 i Reduced size from previous combiner 60 A breaker branch input: 4to 1/0 AWG copper conductors LL Cp = O Centered mounting brackets support single stud Main lug combined output: 10 to 2/0 AWG copper conductors w Il O Neutral and ground: 14 to 1/0 copper conductors LL ,r mounting Always follow local code requirements for conductor sizing. Supports back and side conduit entry Altitude To 2000 meters(6,560 feet) E Up to four 2-pole branch circuits for 240 VAC plug-in INTERNET CONNECTION OPTIONS LLI -- breakers(not included) Integrated Wi-Fi 802.11b/g/n 80 A total PV or storage branch circuits Ethernet Optional,802.3,CatSE(or Cat 6)UTP Ethernet cable (not included) Cellular CELLMODEM-M1 4G based LTE-M cellular modem(not included).Note that an Enphase Mobile Reliable Connect cellular modem is required for all Ensemble installations. Durable NRTL-certified NEMA type COMPLIANCE SHEET NAME 3R enclosure Compliance,Combiner UL 1741, CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003 EQUIPMENT Production metering:ANSI C12.20 accuracy class 0.5(PV production) u■ Five-year limited warranty Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 SPECIFICATION L UL listed LISTED I o learn more about Lnpnase otterings,visit enpnase.com ^ SHEET SIZE To learn more about Enphase offerings,visit enphase.com u E N P H A S E ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 3,and other trademarks or service names are the v E N P H A S E ANSI B trademarks of Enphase Energy,Inc.Data subject to change.2021-05-20 11" X 17" SHEET NUMBER PV-6