HomeMy WebLinkAboutEric Cendejas Unirac Duo DS 1 1 2 1 3 4 5 6 7 8 9
RESIDENTIAL UNIVERSAL PV STRUCTURAL PLAN. I CERTIFY THAT THE SHEETHING&FRAMING OFTHIS STRUCTURE WILL SAFELY W
COMMON SOLAR
APPEARANCOMPONENT
CE MAY VARY. MY EXAMPLES
SHOWN, ACCOMMODATE CALCULATED
LOADS.THIS SPIFT NATTESTEDLTO FORCES AND EQUIPMENT p CODE&AL CURRENT BREFERENCED STANDARDSIDA BUILDING L12 EXPOSURE DESIGNED 0&VSKr160 MPH.EXPOSURE D CONTRACTOR SHALL COMPLY WITH CURRENT NFPA 1 SOLAR PRO
11,V=ULT170 MPH. THIS UNIVERSAL PLAN IS INTENDED FOR RESIDENTIAL PV ISIONS iktiti*�TIONS 1,4100
4 �� #�
MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT. CU +6 /��/#�
UNIRAC SOLARMOUNT UNIVERSAL INSTALLATION PLAN GROUNDING FOLLOW OEM Proper Flashing Placement ++!fi
- GROUNDING PV MODULE P 9
A =_ MID-CLAMP INSTRUCTION SHEETS +t
MID-CLAMP �+
�V� FOR PROPER FLASHING
o 1.THIS IS A SINGLE SHEET UNIVERSAL STRUCTURAL PLAN.ELECTRICAL PLAN IS PV RAIL PLACEMENT Ho.591Q
a G G SEPARATELY SEALED DOCUMENT. HEX HEAD BOLT ROOF T
`3 TILE
2.THIS PLAN OFFERS THREE INSTALLATION METHODS. PV RAIL F3/8-16
LANGE NUT — ® '
w a.FRAMING METHOD.SEE DRAWING(s) O
3 a= AT
b.SHEATHING METHOD.SEE DRAWING(s) 0 IF
L-FOOT O # +t, IS� Ty, f
c.STANDING SEAM METAL ROOF.USE CLAMP OF CHOICE; . OFi4 -.'
p W i5 METAL PLATE,
ago ACE https:I1WWW.aceclamp.comistanding-seam-metal-roof-clamps SQUARE OR ROUND rr'`DgLO `
c W S-5 httpsals-5.comlproductslroof-clamps) oil 1111"
TRA http://trasnowandsun.com/product-category/solar-mounting/ ROOF
o= J.CONTRACTOR SHALL MAKE CLEAR TO AHJ WHICH INSTALLATION DETAILS WILL BE SHEETING 1�^
USED,AND PROVIDE OEM DATA SHEETS,MANUALS OR OTHER INFO REQUIRED BY AHJ EXISTAOOF EXISTING Digitally signed by
S FOAM FRAMING
$o o ASPH.SHINGLE FLORIDA PRODUCT ADHESIVE
4.SOLAR EQUIPMENT ADDS LESS THAN 4-PSF GRAVITY LOAD TO STRUCTURE. APPROVED SEALANT
Q 8 a 4-MINIMUM EXISTING FOUR#14 CRS SCREWS a l l e n d g eze I m a n
6 5. THERE SHALL BE A PV MODULE TO RAIL MOUNTING CLAMP AT EVERY #12 X 2-INCH, 1"BEYOND BOTTOM OF
B G °o SS,SMS UNDERLAYMENT DECK 1 ji'-16X 1K'Iflte0L7
W E MODULE/RAIL CROSSING POINT WITH MINIMUM 4 CLAMPS PER MODULE. '1w�TMK' Date: 2021 .12.15
z a e ADJOINING MODULES SHALL SHARE MID CLAMPS.MODULES MAY BE 03 SpL"NTE'TILE,SINGLE PLY SE NTS TILE ROOFATTACHMNET
LANDSCAPE OR PORTRAIT AT CONTRACTOR OPTION. 1z^ 16:22:40 -05'00'
s 0 6. PV MOUNTING RAILS SHALL BE INSTALLED PERPENDICULAR TO ROOF
`= FRAMING.SEE ROOF ATTACHMENT SPAN TABLE @UPPER RIGHT MID-CLAMP MID-CLAMP ALLEN GEZELMAN
7. THERE SHALL BE A MINIMUM OF TWO RAILS UNDER EACH PV MODULE. 3/8-16 x 3/4 HEX HEAD BOLT - State Of Florida, Professional
8.CONTRACTOR SHALL SUBMIT&ABIDE BY THE RAIL OEM INSTRUCTIONS. PV RAIL 3/8-16 FLANGE NUT ,
Engineer License No. PE 59180
9. RAILS SHALL ATTACH TO ROOF THRU L-FEET AS SHOWN HEREON. L-FEET EXIST. PV MODULE PV RAIL e^ 16502 Hanna Rd,
Ue REQUIRE FLASHINGS WHICH CAN BE SF-SO(SELF-FLASHING,SHEETING ONLY) ROOF TILE TRA MOUNTING CLAMP ACE CLAMP Lutz, FL 33549
SHOWN HEREON OR MIN 4"x 8"x 26 GA.GALV,0.032 ALUM,OR INDUSTRY EXIST.METAL 7 PH 813-909-1956
0 STANDARD OEM FLASHINGS OVER ATTACHMENTS LAGGED INTO ROOF DECKING 1f" '"
w L-FOOT ON ROOF — , Allen@GezelmanPE.com
LU FRAMING, E.G. UNIRAC SOLARMOUNT,UNIRAC FLASHKIT,OTHER ACCEPTABLE SHEETING
C z a TO AHJ. www.GezelmanPE.com
10. SF-SO ROOF ATTACHMENTS ARE INTENDED TO BE INSTALLED INTO
w SHEETING ALONE,HAVE BEEN SO TESTED AND ARE RATED AT 900-POUNDS MIN 3• ssPRo7EABRACKE7 PAPER PLANS SHALL BEAR
WATER
N ALLOWABLE PER ROOF ATTACHMENT. PROOFING I ss-u CLAMP SIGNATURE&SEAL
OPTIONAL P
u 11. ALL FLASHINGS SHALL BE INSTALLED IN A GENEROUS BED OF FLORIDA TILE ROOF FILL CAVITY WITH uNIRAGFLASHKIr APPROVED METAL ROOF CLAMPS If...This item has been electronically
EXISTING FRAMING 09 10
STANDOFF scALe.Nrs scA�e NTs
< PRODUCT CONTROL APPROVED(PCA)POLYURETHANE ROOF SEALANT. OR LONG DOW FOAM signed and sealed by Allen Gezelman
Z ?� L-FOOT
12. LONG L FEET&/OR STANDOFFS ARE PERMITTED AS NEEDED FOR ROOF on the date adjacent to the seal.Printed
O �i WATER PROOFING
U CLEARANCE. MIN.4#14 X 2"SMS-SS WITH SONOLASTIC 5/16"CRS.LAG W/3" copies of this document are not
13. ENGINEER OF RECORD IEOR PREFERS EMAIL COMMUNICATION: 1"BEYOND BOTTOM OF NP-1 OR EQUAL THREAD EMBEDMENT DECK NOT[NLOJDED
DECK POLYURETHANE CAULK IN BLOCKING,JOIST, IN TILT LEG CIS considered signed and sealed and the
OR ATTACRUSSHMENT;
SHA authentication code must be
a en@geze manpe.com FRAMING-METAL ROOF ATTACHMENT;
ENGINEERING NOTES. BARREL TILE ROOF ATTACHMNET ROOF COVERING COULD BE SHINGLE,TILE,OR SINGLE-PLY.
of D5 _E NTs o6 s�E„� verified on any electronic copies
SCALE:NTS
%'-16 z 1y"56 HIX BDLT
O %'z 1W■%"HD FMDER WASHER
/ %,-is6TRUT NUT
ID a PART TABLE {y` Ag
u P/N DESCRIPTION B N
wz CT)004275M FLASHLOC DUO MILL,20 PACK f�
BND T & p N
LL 004275D FLASHLOC DUO DARK,20 PACK NUT 3/8-xl-"xl"SS
o "
A \ -16 56 FLANGE NUT M N
E FLORIDA ROOF ATTACHMENT SPACING(FEET): k LL
U o ROOF HEIGHT<30-FT & ROOF SLOPE<30° - O
U #12-14 SCREW,HWH,SS,SELF-DR WIND(MPH) PZ1 PZ2 PZ3 UNIRAC RAIL i� s "' , 1� �I j6'L16XTS5 Het BOLT W tLl
LL' E O o W/#12 EPDM WASHER 110 8 6 4 SM-L 1sa L� 1
m ® 120 8 6 2 SM-L _--� .- pQ�e DETAIL B 11i'X1�/i•X K'ID FHOeI WAWta7l CD i--I
m Q 0 SS SERRATED 130 6 4 2 SM-L - w I- c2 � Q
?ae T W' (C (n
r FLANGE NUT 140 6 4 2 SM-S sse _ f -- � U� CLINT HD I [') "" U LLB
_ sse so MOUNT STANDARD I— Q
® m 150 6 4 2 SM-S w MINIMUM 31 16" U J k O fSH
0 160 6 4 2 SM-HD 1� d 1_ — MINIMUM 2 T " MINIMUM 3 S�6n HEIGHT Q 0 UEd dj
® 170 4 4 SM-HD 60 HEIGHT 1�6 Q w J U V V
E ® ® 180 4 2 SM-HD .:�_. .� __.. 1S0 J—_ Z W O_ O U
FLASHLOC DTD ....r� " .. (n
w zs�„ MILL OR DARK 1 1 J!L �• "^' - """ i/9 U00
LL w 0
y
43j., B r r-- -i,'4 i m' ..,....'.::.� va i� U 00 tU Li
z ' i i d a Sae END CLAMP O CL
o I ; G 6h 1 MID LU
o L_____J rn• fl•= , ppyR iNY uLel.nR dRrr KM LaRR.r,k LU
z _.
,n2 3�Y L -�-J10
y� N,R4 fnMn ss,.YVH WwMr sariw. Lfl V/
•yll^ }lh1[
-a 3 UNIRAC Res e I 0% O
Y N s'/z" iLit roo6 0 c 7 degrees Ga1Ne*aDF Hlprool
'M•-16
p g PZV:FIELD-OF-ROOF----INTERIOR FANGENUT
PZ1:FIELD-OF-ROOF EXTERIOR %%16X%'T BOLT
a PZ2:ROOF PERIMETER O z'4 (MIN.3'LEAST OF 40%EAVE HEIGHT OR 10%BUILDING L/W.
F 3 sz� PZ3:OUTSIDE CORNERS ® Plan Code:
o u L&W=PZ2,a=PZ2 WIDTH.,h=EAVE HEIGHT. �2"� �2—•�
oz f
> FLASH LOC DUO ATTACHMENT UNIRAC D U O
a z u 02 07 FLORIDA WIND ZONES ASCE 7-16 11 UNIRAC SOLARMOUNT SYSTEM COMPONENTS
w a ALE NT5 ALE NT5 rev 11-04-2021
w SCALE:N/A