Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GRID TIED PHOVOLTAIC SYSTEM
CODE INFORMATION U � a ULJ w o � SOLAR INDIVIDUAL PERMIT PACKAGE Y a �a �a� APPLICABLE CODES, LAWS AND REGULATIONS 2020 7TH EDITION FLORIDA BUILDING CODE (FBC) o D v v 2020 FLORIDA FIRE PREVENTION CODE (FFPC) o ° z 2017 NATIONAL ELECTRIC CODE (NEC) 2020 FLORIDA ENERGY CODE (FEC) a o " a RAYMOND SMITH a U o� Digitally signed by Heinrich Heinrich Villanueva 7.60 kW GRID TIED PHOTOVOLTAIC SYSTEM Villanueva°60;44z08'0o'' AC SYSTEM SIZE = 6.91 KW SATELLITE IMAGE 7723439763 PROJECT LOCATION 5771 TRAVELERS WAY FORT PIERCE, FLORIDA 34982 AHJ : ST. LUCIE COUNTY UTILITY: FLORIDA POWER & LIGHT CO JOB NOTES SHEET INDEX LU V) 00 LU Y SCOPE OF WORK PV SOLAR ARCHITECTURAL DRAWINGS - (N) 7.600 KW PHOTOVOLTAIC SYSTEM PVA-0 COVER SHEET PVA-1 ARRAY LAYOUT = Q Q m Q Q - (19) 40OW (MODEL SPR-A-400-G-AC) PV MODULES 0 U) 0 0 c LU 0 LU w - POINT OF INTERCONNECTION AT MAIN SERVICE PANEL ° Q w LU Q w WITH LINE SIDE TAP � w o 0 Q� in� o �� In > o SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEC2017, NFPA70 AND THOSE SET PV SOLAR STRUCTURAL DRAWINGS � 3 � z g FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, PVS-1 MOUNTING DETAILS o 00 MAXIMUM NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODEL NUMBER, INTERVTER MANUFACTURER AND MODEL NUMBER, AS APPLICABLE REVISIONS REV DESCRIPTION DATE DB SYSTEM CONTAINS SAME INFORMATION WITHIN FSEC CERTIFICATION: MAXIMUM NUMBER OF MODULE BRANCHES: 2 BRANCHES PV SOLAR ELECTRICAL DRAWINGS MAXIMUM NUMBER OF MODULES PER BRANCH: 10 MODULES PVE-1 ELECTRICAL SINGLE -LINE DIAGRAM & DRAWN BY: MAXIMUM OUTPUT PER MODULE: 349W, 1.45A @240V SPECIFICATIONS MODULE MANUFACTURER AND MODEL NUMBER: SUNPOWER (SPR-A400-G-AC) PVE-2 ELECTRICAL CALCULATION crPeISTI/YlI FULGENCIO INVERTER MANUFACTURER AND MODEL NUMBER: SUNPOWER (IQ7AS-66-ACM-US) PVE-3 ELECTRICAL DATA & SPECIFICATIONS PVE-4 EQUINOX GROUNDING DETAILS INSTALLER SKY SOLAR ENERGY IN PROJECT RP-183683 DATE DRAWN 11-10-2021 FSEC REGISTRATION NUMBER: 401075 PVE-5 BRANCH DIAGRAM SCALE NTS SHEET PVA-0 L E G E N D 0 JUNCTION BOX CONDUIT UTILITY SERVICE POINT AND METERING PROPERTY LINE ��� FIRE ACCESS PATHWAY 65'-7" ROOF ACCESS POINT N1C NEW LOAD CENTER AC DISCONNECT I ROOF ACCESS POINT ❑ D (E) GARAGE G rn 36" / V / T C NOTE: 1. FIELD ADJUSTMENTS OF FEWER THAN 6" FM ----- — D MAY BE ALLOWED BASED ON SITE ___________ ___________ ` CONDITIONS AND MEASUREMENTS. F[ 2. DESIGN WIND SPEED = 159 MPH Li I ROOF 1 1 2 MODULE QTY. 17 2 AZIMUTH 180° 271° PITCH 4.5:12 4.5:12 CONTRACT MODULE 19 SPR-A400-G-AC (240) & QUANTITY MICROINVERTER 19 IQ7A5-66-ACM-US (240) TYPE & QUANTITY ROOF TYPE COMP SHINGLE N ROOF ATTACHMENT 70 QUANTITY STORY 1 -STORY HOME TYPE TOTAL 388 SQ.FT. ARRAY AREA W (D N 00 < U ~ cn 2 W o W g W LL a J } LLI U ,--i W � a � � z O LL J O In REVISIONS DESCRIPTION DRAWN BY: C♦ ISTI FULGENCIO INSTALLER SKY SOLAR ENERGY IN PROJECT RP-183683 DATE DRAWN 11-10-2021 SCALE 1/16" = 1'-0" SHEET PVA-1 In LLJ W o 0 Ln u v o > > v 3 Ln a o 4 A z K U o 4 A O v o " �- m z a � o Z a o = _ a O O W (j W N U_ rn U0J Q Q M Q H O ap ~mow w p � U_ C7 Q W U_ 0- FIG a Q Lu JJz U 7)C QLU ^ a U f DC p Ln o C z O V QUL Q Y _J n REVISIONS REV DESCRIPTION DATE IDS DRAWN BY: CSTI FULGENCI° INSTALLER SKY SOLAR ENERGY IN PROJECT RP-183683 DATE DRAWN 11-10-2021 SCALE NTS SHEET PVS-1 TABLE 1 -ARRAYS INFORMATION MAX. ROOF ROOFING ATTACHMENT NO. OF FRAMING PENETRATION MAX. ATTACHMENT MAX. RAIL RAFTER PITCH TYPE TYPE STORIES TYPE (in.) PATTERN (in.) SPACING (in.) OVERHANG (in.) SPAN (ft.) ROOF 1 21° Comp Shingle Pegasus L-foot 1 2x4 Truss @ 24" OC 6' Staggered 24" 8" ROOF 2 21° Comp Shingle Pegasus L-foot 1 2x4 Truss @ 24" OC 6' Staggered 24" 8" -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- CHECK TABLE 2 FOR PENETRATION PATTERN GUIDE FIG 1.1: ROOF 1 STRUCTURAL FRAMING DETAIL FIGURE 2: INVISIMOUNT ROOF ATTACHMENT DETAILS @TRUSS RAFTERS FLASHING INVISIMOUNT RAIL +� 2�YN INVISIMOUNT RAIL PV MODULE PV MODULE PV MODULE HEX CAP _ COMPOSITION SHINGLES L FOOT SHINGLE ON TOP OF FLASHING l FLASHING SHOE ASSEMBLY z f 5/16" S.S. LAG BOLT WITH III I" WASHER @ - CENTER TYP. PRE -DRILL REQUIRED. EXTERNAL LOAD 2"X4" TRUSS OR RAFTER (DOUGLAS FIR OR EQUAL) BEARING WALL 0.75" MIN. FIGURE 3: MOUNTING CLAMP FIG 1.2: ROOF 2 STRUCTURAL FRAMING DETAIL TABLE 2: PENETRATION GUIDE FOR INSTALL POSITIONING DETAILS TWO OR MORE ROWS OF MODULES FLASHING 2" 11.8" 11.8. 1.8 "y�2" INVISIMOUNT RAIL - - _ I 1 1 1 1 1 I I 1 1 --1 I PV MODULE I 1 1 1 1 1 I I 1 1 1 1 1 I I 1 1 1 1 I �00 I 1 1 1 1 1 I I 1 1 1 1 1 I I 1 1 1 1 I � I 1 1 1 1 1 I I 1 1 1 1 1 I I 1 1 1 1 I ( I ICI O STACKED STAGGERED FULLY STAGGERED OOOOO � �� w z 00000 O ONE ROW OF MODULES 00000 00000 EXTERNAL LOAD BEARING WALL 66CELLMODULE FULLY STAGGERED STACKED/STAGGERED • RAILS SHALL BE POSITIONED IN THE NON -CROSS HATCHED REGIONS *CHECK TABLE 1 FOR MAX.. PENETRATION SPACING AND PENETRATION PATTERN FOR EACH ARRAY. m � a LUw O o � a o O o z o m z Z Q � O o a Q � O = _ a M cC �O � ^ p a LU ((f LU r N (D U_ rn U0J W Q Lnof cj� 0 (� p LUO LL C7 J J LU - Lu Z Z Z = > -i a < Lu QQZ cl�U D Q ^ a U p � Z O VQ L Q Y J o O U) n REVISIONS REV DESCRIPTION DATE DB DRAWN BY: C RISTIK� FULGENCIO INSTALLER SKY SOLAR ENERGY IN PROJECT RP-183683 DATE DRAWN 11-10-2021 SCALE NTS SHEET PVS-2 e SUNPOWER MODULES SPR-A400-G-AC (240) MICROINVERTER MODEL: IQ7AS-66-ACM-US (240) ROOFTOP ARRAY WIRING Bran , 9 Circuit ACDMODULES 1 I Branc \ACI Circuit 110 AChMODULES2 TAG DESCRIPTION 0 SOLAR AC MODULE / BRANCH Q DC / DC CONVERTERS Q3 SOURCE CIRCUIT JUNCTION BOX ® SEPARATE DC DISCONNECT INTERNAL INVERTER DC DISCONNECT © STRING INVERTER SOLAR LOAD CENTER ® PV PRODUCTION METER A SEPARATE AC DISCONNECT ACM NO YES NO NO NO YES NO YES PV CERTIFICATIONS AND COMPLIANCE • UL 1741 / IEEE-1547 • UL 1741 AC MODULE (TYPE 2 FIRE RATED) • UL 62109-1 / IEC 62109-2 • UL LISTED PV RAPID SHUTDOWN EQUIPMENT ENABLES INSTALLATION IN ACCORDANCE WITH: • NEC 690.6 (AC MODULE) • NEC 690.12 RAPID SHUTDOWN (INSIDE AND OUTSIDE THE ARRAY) • NEC 690.15 AC CONNECTORS, 690.33(A)-(E)(1) A (N) SOLAR LOAD CENTER A 100A MIN., 120/240 V, M.L.O, NEMA-311 JUNCTION BOX, LOCATION: EXTERIOR WALL NEMA-3R 0 F MLO� r I Or�P I�L2�' " 15�2P FIGURE A: SINGLE LINE DIAGRAM - 7.60 kW ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e -4 �VS66 (3) #14 THWN (1) #14 THWN EGC 40A -J��PN-G BOND INSIDE D AC DISCO 9 UTILITY -LOCKABLE SAFETY SWITCH 60A, 240VAC SQUARE D D222NRB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR SIZE NUMBER OF TAG CONDUCTOR TYPE (AWG) CONDUCTORS SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY #12 2 ❑A EGC: BARE Cu #6 1 THWN-2 #10 4 B EGC: THWN-2 #10 1 THWN-2 #8 3 ❑ EGC: THWN-2 #10 1 THWN-2 #6 3 D ❑ GEC: THWN-2 #6 1 INCOMING SOURCE FEED (E) MAIN SERVICE PANEL MANUF:SQUARE D 150A, 120/240 V, 1 PH, 3 W LOCATION: INSIDE GARAGE LINE SIDE TAP F z F(E) ~ UTILITY ILSCO KUP-L-TAP BIDIRECTIONAL IPC-4/0-6 PV DISCONNECT I W METER #: I ACD8515 LOCATED WITHIN FROM THIS TAPAP Digitally signed C h I MCB 150A, 2P ftj H \/ by Chi F Leung TO 1 � � Date: 2021.11.11 Leung 16:52:54 08'00' EXISTING I I � I LOADS E C This item has been signed and sealed by Chi Fung Leung, PE on the date and / or time stamp shown using a digital signature. Jnot I Printed copies of this document are considered signed and sealed and the signature must be verified — on any electronic copses. EXISTING GROUND — ELECTRICAL NOTES ONDUIT/CABLE TYPE CONDUIT SIZE 1. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 2. ALL CONDUIT BEND RADII TO CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS. BRANCH CIRCUIT FROM PV ARRAY TO __ 3. MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENT TO BE INSTALLED. JUNCTION BOX 4. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS. 5. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 6. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING NEC REQUIREMENTS. EMT 3/4" 7. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY 3RD PARTY. 8. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 9. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. EMT 3/4" 10. EQUIVALENT SPECIFICATION ON CABLES AND ELECTRICAL EQUIPMENT SPECIFIED ARE ACCEPTABLE. 11. AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. EMT 3/4" AC MODULES NOTES 1. DC CIRCUIT IS ISOLATED AND INSULATED FROM GROUND AND MEETS THE REQUIREMENT OF NEC 690.35. 2. SUNPOWER PROVIDED CABLES COMES WITH TWO (2) #12 AWG WIRE AND THIS IS BY DESIGN. NEUTRAL AND ADDITIONAL GROUND WIRE IS NOT REQUIRED FOR PROVIDED TRUNK AND EXTENSION CABLES. 3. SUNPOWER AC MODULES HAVE BEEN TESTED AND CERTIFIED TO UL 2703 FOR INTEGRATED GROUNDING AND HENCE A SEPARATE GROUND WIRE IS NOT REQUIRED WITHIN THE ARRAY. 4. USE ROW -TO -ROW GROUNDING CLIP PROVIDED TO GROUND ROWS OF MODULE. BOND SUB -ARRAYS BY RUNNING #6 AWG BARE CU WIRE AND GROUND LUGS AT A SINGLE POINT ON EACH SUB -ARRAY AND THEN TO THE JUNCTION BOX. REFER TO PVE-4 FOR ADDITIONAL DETAILS. w LU V) N Q 00 It = Q ~ >Q Q Q a > �_ w Z -ZO (n O W CL J H ~O w LL 0- -1 V 0 a Q Lu JZ U p U w Q a >QN LL gW Lu Ow � n 1 EVISIONS I REV DESCRIPTION DATE DB DRAWN BY: �p CgRISTI F/YFI PULGENCIO INSTALLER SKY SOLAR ENERGY IN PROJECT RP-183683 DATE DRAWN 11-10-2021 SCALE NTS PVE-1 9. x N H � ELECTRICAL CALCULATIONS W x a U,v, o 3 a � O z u O a o z K a ti O = x V a O O ' ^ V This item has been signed and sealed by Chi Fung Leung, PE on the date and / or time stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. w U) w U) 00 Q U M Y z 2 J Q M Q a g O 2 W O W J p > LL a- U Tz p a- a L a Q 0 H � =p U LU Q ~ a tY u^i z w O (D LL Q �C J U) R E V I S I O N S REV DESCRIPTION DATE DB DRAWN BY: C RISTI FULGENCIO INSTALLER SKY SOLAR ENERGY IN PROTECT RP-183683 DATE DRAWN 11-10-2021 SCALE NTS SHEET PVE-2 SUBPANEL TO GRID -TIE WIRING #8 VOLTAGE 240 V SUM OF BRANCHES: lOUT-TOTAL = 27.55 A MINIMUM WIRE AMPACITY: 'MAX = IOUT x 1.25 34.44 A CONDUCTOR DE -RATING MAXIMUM AMBIENT TEMPERATURE 35 °C TEMPERATURE USED FOR AMPACITY DE -RATING 35 °C TEMPERATURE DE -RATING COEFFICIENT 0.96 FILL DE -RATING COEFFICIENT 1.00 lwiREMiN =IMAx / TEMP_COEFF / FILL_COEFF 35.87 A WIRE SIZE AMPACITY 55 A CONDUCTOR SIZE #8 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #8 ONE WAY CIRCUIT LENGTH 15 FT. VOLTAGE DROP 0.27% OVERCURRENT PROTECTION 40A, 2P MINIMUM OCPD = lour x 1.25 34.44 A BRANCH1 BRANCH2 ROOF JCT BOX TO SUBPANEL WIRING #10 #10 NUMBER OF MODULES 9 10 VOLTAGE 240 V 240 V RATED AC OUTPUT CURRENT: lour = 13.05 A 14.5 A MINIMUM WIRE AMPACITY: IMAx = lour x 1.25 16.31 A 18.13 A CONDUCTOR DE -RATING MAXIMUM AMBIENT TEMPERATURE 35 °C 35 °C TEMPERATURE ADDER 22 °C 22 °C TEMPERATURE USED FOR AMPACITY DE -RATING 57 °C 57 °C TEMPERATURE DE -RATING COEFFICIENT 0.71 0.71 FILL DE -RATING COEFFICIENT 0.8 0.8 lwiREMiN = 'MAX / TEMP_COEFF / FILL_COEFF 28.72 A 31.91 A WIRE SIZE AMPACITY 40 A 40 A CONDUCTOR SIZE #10 #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 #10 ONE WAY CIRCUIT LENGTH 25 FT. 25 FT. CALCULATED VOLTAGE DROP 0.34% 0.37% OVERCURRENT PROTECTION 20A, 2P 20A, 2P MINIMUM OCPD = lour x 1.25 16.31 A 18.13 A � a w w o O WARNING WARNING o WARNING /� ( , Q •- SOURCE ELECTRIC OSHCKHAZARD POWER 4,/ LL O F m z Q a O o . . •WER SUPPLY Z .� Q 2 O = _ v TERMINALS ON. OUTPUT CONNECTION a v .. • • • - . . • • RELOCATE SOURCES: GRID . : ENERGIZED LOAD v l O z IN THE OPEN POSITION NEC 705.12 (B)(3) NEC 690.13 (B) NEC 705.12 (B)(2)(3)(b) PLACE ON PV SYSTEM DISCONNECTINS MEANS PLACE ADJACENT TO BACK -FED BREAKER PLACE ON ALL EQUIPMENT THAT IS SUPPLIED BY BOTH POWER SOURCES RAPID DOWN PHOTOVOLTAIC POWER SOURCE WARNING OPERATING VOLTAGE 240 V PHOTOVOLTAIC SYSTEM SWI OR This item has been signed and sealed by Chi Fung Leung, PE on the MAXIMUM • ' COMBINER PANEL date and / or time stamp shown digital . 55 . • LAREMAC using a signature. - CURRENT OUTPUT Printed copies of this document are not considered signed and sealed DO NOT ADD LOADS and the signature must be verified on any electronic copies. NEC 690.56 (C)(3) NEC 690.54 PLACE ON RAPID SHUTDOWN SWITCH OR EQUIPMENT PLACE ON INTERCONNECTION DISCONNECTING MEANS WITH INTEGRATED RAPID SHUTDOWN *REFLECTIVE* EQUIPMENT LABEL NOTES 1. LABELS SHOWN ARE THEIR LU ACTUAL REQUIRED SIZE. WARNING: PHA OTOVOLTAI( SOLAR PV SYSTEM EQUIPPED 2. LABEL MATERIAL SHALL BE SUITABLE FOR c}iI ^' w cn a o THE EQUIPMENT POWER SOURCE u } � � r WITH RAPID SHUTDOWN ENVIRONMENT. 3. CONDUIT SHALL BE MARKED = Q p a R o Q _v WITH REQUIRED LABEL p � c OJ w NEC 690.31 (G)(3)&(4) EVERY 10 FEET. p w Uj a can PLACE ON ALL JUNCTION BOXES EXPOSED RACEWAYS 0 a Q LU Q Q TURN RAPID SHUTDOWN EVERY 10' AND 1' FROM BENDS AND PENETRATIONS, g o U o Q ADJACENT TO THE MAIN SERVICE DISCONNECT *REFLECTIVE* Q ^ a o SWITCH TO THE °� � z Q "OFF" POSITION TO O LL SOLAR PV SYSTEM EQUIPPED U Q LU O) SHUT DOWN PV SYSTEM WITH RAPID SHUTDOWN w ANDREDUCE . • - REVISIONS REV DESCRIPTION DATE DB SHOCK HAZARD N THE ARRAY NEC 690.13 (B) PLACE ON PV SYSTEM DISCONNECTING MEANS DRAWN BY: NEC 690.56 (C)(1)(a) CfISTIA'N FULGE NCIO INSTALLER SKY SOLAR ENERGY IN PLACE WITHIN 3FT OF SERVICE DISCONNECTING MEANS TO PROJECT RP-183683 WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL DATE DRAWN 11-30-2021 INDICATE THE LOCATIONS OF RAPID SHUTDOWN SWITCHES SALE NTS F"T PVE-3 W w o 3 a o z�Uo oCl- o� �mZ Z a o 0 � a � o = = v z v u �100 This item has been signed and sealed by Chi Fung Leung, PE on the date and / or time stamp shown using a digital signature. Printed copies of this document are Lee not considered signed and sealed and the signature must be verified on any electronic copies.9! its Lu 00 a U O� Y Q Q m Q � Q 0 0 Ln O o LU o W O Lu 1,_ a z a a LLB J O � a o F- � o Lu Q H a > tY C Ln Q O o a Y J o O U) r; REVISIONS REV DESCRIPTION DATE DB DRAWN BY: CWISTI/IfN FULGENCIO INSTALLER SKY SOLAR ENERGY IN PROJECT RP-183683 DATE DRAWN 11-10-2021 SCALE NTS SHEET PVE-4 SunPower InvisiMount"^with R2R Grounding Clip Ground Path and Compliance OUR � Module r/ �Irp * `° ��K• -xrw POWER TO THIS BUILDING IS ALSO �"h SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT(S) � service' Module N "�` LOCATED AS SHOWN: 1 � Bonding Components MAIN SERVICE ��,�a� PANEL �•«�� E Grounding Electrode to � 690.47(A) Na GEC a• Service Panel 690.47(D) 2 Service Panel to 690.43(c) �7ai PHOTOVOLTAIC Ground Wire ARRAY O N ROOF Ground Wire to Ground Lug to Rail 690.43(C) 2703 SOLAR LOAD 4 Module Frame to 690.43(C) 2703 CENTER Module Frame 5 Module Frame n/a 1703 �+ AC -------- - - C; x N H � x a INSTALLER NAME: w 0 BRANCH VOLTAGES: z 0 1. 0 ^ 2. a " 0 O 0 Z 0 a = = x `^ 3. a 0 4. 0 ' ^ 5. U vI 6. This item has been signed and sealed by Chi Fung Leung, PE on the date and / or time stamp shown using a digital signature. Printed copies of this document are T not considered signed and sealed O and the signature must be verified on any electronic copies. O N w U) 00 a U rn Y = Q Q M Q g 0 � o Cn p LU w Q 0 > -i a 0 o < L Q U Lu H �p Q — Q ~ ^ a m tY p Ln O Q �C J 0 Ln R E V I S I O N S ROOF 1 N-LC [ACD ® REV DESCRIPTION DATE DB DRAWN BY: ci s 1..,. ; o C RISTI FULGENCIO N INSTALLER SKY SOLAR ENERGY IN PROTECT RP-183683 DATE DRAWN 11-10-2021 SCALE 19/128" = 1'-0" SHEET PVE-5 ROOF 1 2 MODULE QTY. 17 2 AZIMUTH 180° 271° PITCH 4.5:12 4.5:12 A -Series: A420 I A415 I A410 I A400 I A390 Sun Power°Residential AC Module SUNPOWER1111 ' 420-390 W Residential AC Module SunPower° Maxeon°Tech nology Built specifically for use with the SunPower EquinoxTM system, the only fully integrated solution designed, engineered, and warranted by one manufacturer. I❑ Fundamentally Different. And Better. SunPower® Maxeon®Technology • Most powerful cell in home solar z • Delivers unmatched reliability • Patented solid metal foundation prevents breakage and corrosion Factory -integrated M icroinverter (M I) • Highest -power integrated AC module in solar • 60% lighter than prior SunPower Mls • Engineered and calibrated by SunPower for SunPower AC modules Highest Power Density Available. Sun Power's new Maxeon° Gen 5 cell is 65% larger than prior generations, delivering the most powerful cell and highest -efficiency module in residential solar. The result is more power per square meter than any commercially available solar. E E Ln NI 1 Highest Lifetime Energy and Savings. Designed to deliver 60% more energy over 25 years in real -world conditions like partial shade and high temperatures.' 15096 3 140�6 `m q 13096 = 12016 m T 110°5 100% m G 9045 07 8096 CU 70% ry 6096 1 5 10 15 20 25 Years of operation Up to 60% more lifetime energy Best Reliability. Best Warranty. With more than 25 million modules deployed around ' the world, SunPower technology is proven to last. That's '• why we stand behind our module and microinverter with the industrys best 25-year Combined Power and Product Warranty, including the highest Power Warranty in solar. DC Power Data A420-G-AC A415-G-AC A410-G-AC A400-G-AC A390-G-AC Nom. Powers (Pnom) W 420 415 410 400 390 Power Tol. +5/-0% Module Efficiency 22.5 22.3 22.0 21.5 20.9 Temp. Coef. (Power) -0.29%/'C Shade Tol. Integrated module -level max. power point tracking Tested Operating Temp. Operating Conditions -40'F to +185'F (-40'C to +85'C) Max. Ambient Temp. 122°F (50°C) Max. Test Load' Wind: 125 psf, 6000 Pa, 611 kg/m2 back Snow: 187 psf, 9000 Pa, 917 kg/m2 front Design Load Wind: 75 psf, 3600 Pa, 367 kg/mz back Snow: 125 psf, 6000 Pa, 611 kg/M2 front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Solar Cells Vlechanica� Data 66 Monocrystalline Maxeon Gen 5 Front Glass High -transmission tempered glass with anti -reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA rating) Weight 46.5 Ibs (21.1 kg) Recommended Max. Module Spacing 1.3 in. (33 mm) 1 SunPower415 W, 22.3% efficient, compared to a Conventional Panel on same -sized arrays (260 W, 16% efficient, approx. 1.6 m�), 7.9% more energy per watt (based on PVSyst pan files for avg. US climate), 0.5%/yr slower degradation rate (Jordan, et. al. "Robust PV Degradation Methodology and Application:" PVSC 2018). 2 Based on search of datasheet values from websites of top 10 manufacturers per IHS, as of January2019. 3#1 rank in"FraunhoferPV Durability Initiativefor Solar Modules: Part K' PVrech Power Magazine, 2015,Campeau,Z.etal."SunPowerModule Degradation Rate;' Sun Powerwhite paper,2013. 4 Factory set to 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. 5 Standard Test Conditions(1000 W/m2 irradiance, AM 1.5, 25'C). NREL calibration standard: SOMS current, LACCS FF and voltage. All DC voltage is fully contained within the module. 6 This product is UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors; when installed according to manufacturer's instructions. 7 Please read the safety and installation instructions for more information regarding load ratings and mounting configurations. See www.sunpower.com/facts for more reference information. For more details, see extended datasheet www.sunpower.com/datasheets Specifications included in this datasheetare subjectto change without notice. ©2020 Su nPower Corporation. All Rights Reserved, SUN POWER, the SUNPOWER logo, Equinox, and MAXEON are registered trademarks of SunPower Corporation in the U.S. and other countries as well. 1-800-SUNPOWER. Warranties 25-year limited power warranty 25-year limited product warranty UL1703 Certifications UL 1741 / IEEE-1547 and UL 1741 AC Module (Type 2 fire rated) Compliance UL 62109-1 / IEC 62109-2 FCC Part 15 Class B ICES-0003 Class B CAN/CSA-C22.2 NO. 107.1-01 CA Rule 21 (UL 1741 SA)4 (includes Volt/Var and Reactive Power Priority) UL Listed PV Rapid Shutdown Equipment' Enables installation in accordance with: NEC 690.6 (AC module) NEC 690.12 Rapid Shutdown (inside and outside the array) NEC 690.15 AC Connectors, 690.33(A)-(E)(1) When used with InvisiMount racking and InvisiMount accessories (UL 2703): Module grounding and bonding through InvisiMount Class A fire rated When used with AC module Q Cables and accessories (UL 6703 and UL 2238)6: • Rated for load break disconnect PID Test Potential -induced degradation free 72.2 (1835) . B Long side 1.3 (32) B • Short side 0.9 (24) U RIENIT, L LISTED E4-0 Module Fire Performance: Type 2 SUNPCWER Please read the Safety and Installation Instructions 532628 for additional details. 534092 RevB PEGASUS SOLAR'" Simple 3-piece design for rapid installation IN One-piece flashing with elevated cone - No press -fits or deck -level EPDM washers to fail WATERTIGHT FOR LIFE �l El A BETTER DAY ON THE JOB Encapsulating design raises the water seal 0.9" above roof deck Pegasus Solar's Comp Mounts are a cost effective, high -quality option for rail installations on composition shingle roofs. Designed to last decades, the one-piece flashing with elevated cone means there is simply nothing to fail. 1. Drill pilot hole in center of rafter. 3. Place L-Foot over cone and install lag with washer through L-Foot. 5" 93.5" 2.3" 2. Optional: Apply a "U-shape" of sealant to underside of flashing and postition under 2nd shingle course, cone over pilot hole. 4. Drive lag to required depth. Attach rail per rail manufacturer's instructions. 3.5" !0.91, �- 2.3" 2.4" rry Specifications SKU PSCR-CBBO PSCR-UBBO Comp Mount Install Kits SPCR-CBBH PSCR-CMMO PSCR-UMMO Finish Black L-Foot and Black Flashing Mill L-Foot and Mill Flashing L-Foot Type Closed Slot Open Slot Closed Slot Closed Slot Open Slot L-Foot, Flashing, L-Foot, Flashing, L-Foot, Flashing, L-Foot, Flashing, L-Foot, Flashing, 5/16"x 4-1/2" SS Lag 5/16"x 4-1/2" SS Lag 5/16"x 4-1/2" SS Lag5/16"x 4-1/2" SS Lag 5/16"x 4-1/2" SS Lag Kit Contents with metalized with metalized with metalized with metalized with metalized EPDM washer EPDM washer EPDM washer and EPDM washer EPDM washer M10 Hex Bolt Roof Type Composition Shingle Certifications IBC, ASCE/SEI 7-16, AC286 Install Application Railed Systems Compatible Rail Most Flashing Material Painted Galvalume Plus Galvalume Plus L-Foot Material Aluminum 24 72 Kit Quantity Simple and Fast Installation Integrated module -to -rail grounding Pre -assembled mid and end clamps Levitating mid clamp for easy placement Mid clamp width facilitates consistent, even module spacing UL 2703 Listed integrated grounding Flexible Design Addresses nearly all sloped residential roofs Design in landscape and portrait with up to 8' rail span Pre -drilled rails and rail splice Rails enable easy obstacle management Customer -Preferred Aesthetics #1 module and #1 mounting aesthetics Best -in -class system aesthetics Premium, low -profile design Black anodized components Hidden mid clamps and capped, flush end clamps Part of Superior System Built for use with SunPower DC and AC modules Best -in -class system reliability and aesthetics New optional rooftop transition flashing, rail - mounted J-box, and wire management rail clips Combine with SunPower modules and SunPower EnergyLinkO monitoring app Elegant Simplicity SunPower° InvisiMountlm is a SunPower-designed rail -based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster installation time, design flexibility, and superior aesthetics. The InvisiMount product was specifically envisioned and engineered to pair with SunPower modules. The resulting system -level approach amplifies the aesthetic and installation benefits —for homeowners and for installers. sunpower.com U` InvisiMount Components Module' / Mid Clamp and Rail Module' / End Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice sow Mid clamp InvisiMount ComponentDetails Black oxide stainless steel 300 series 63 g (2.2 oz) End clamp Black anodized aluminum 6000 series 110 g (3.88 oz) Rail Black anodized aluminum 6000 series 830 g/m (9 oz/ft) Rail splice Aluminum alloy 6000 series 830 g/m (9 oz/ft) Rail bolt M10-1.5 x 25 mm; DIN 933 SS304 nominal Rail nut M10-1.5; DIN 6923 S5304 nominal Ground lug assembly SS304; A2-70 bolt; tin-plated copper lug 106.5 g/m (3.75 oz) InvisiMount Mid clamp Componentapa Uplift 664 Ibf Shear 540 Ibf End clamp Uplift 899 Ibf Shear 220 Ibf Rail Moment: upward 548 Ibf-ft Moment: downward 580 Ibf-ft Rail splice Moment: upward 548 Ibf-ft Moment: downward 580 Ibf ft L-foot Uplift 1000 Ibf Shear 390 Ibf Ground Lug Assembly (for DCsystems only) InvisiMount Operating Conditions Temperature -40° C to 90° C (-40° F to 194° F) Max. Load (LRFD) . 3000 Pa uplift 6000 Pa downforce Roof Attachment Hardware Supported by Design Tool Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment Curved and Flat Tile Roof Attachment Universal interface for other roof attachments 25-year product warranty Warranties 5-year finish warranty Certifications UL 2703 Listed Class A Fire Rated Roof Attachment Hardware Refer to roof attachment hardware manufacturer's documentation. 1 MOC -. _ -.. _ _. _ _ _ _ _ , _ _ _ _ _ _ _ _ _ _ _, _ _ _ _ _, _ _ _ _ Jware interoperability z SunPower recommends that all EquinoxT" InvisiMountTm, and AC module systems always be designed using the SunPower Design Tool. If a designer decides to instead use the component capacities listed in this document to design a system, note that the capacities shown are Load and Resistance Factor Design (LRFD) design loads, and are NOT to be used for Allowable Stress Design (ASD) calculations; and that a licensed Professional Engineer (PE) must then stamp all calculations. Should you have any questions please contact SunPower Technical Support at 1-800-SUNPOWER (1-800-786-7693). sunpower.com © 2017 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, EQUINOX, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. 509506 RevF All other trademarks are the property of their respective owners. Specifications included in this datasheet are subject to change without notice. Improve Support, Reduce Costs An intuitive monitoring website enables you to: • See a visual map of customer sites • Remotely manage hundreds of sites • Remotely diagnose and troubleshoot system issues • Drill down for the status of individual devices Add Value for Customers With mySunPower'll monitoring customers can: • Track their energy production by day, month, year and in different weather conditions • See their energy use and estimated bill savings • Maximize their savings with automatic system alerts and tips • Customize storage settings and easily monitor and track available battery power • Receive elective system reports SunPower° Monitoring — Plug -and -Play Installation This complete solution for residential monitoring and control includes the SunPower® PV Supervisor (PVS) which improves the installation process, overall system reliability, and customer experience: • Compact footprint for improved aesthetics • Robust cloud connectivity and comprehensive local connectivity • Flexible configuration of devices during installation • Consumption metering • Revenue -quality production metering • Web -based commissioning • Remote diagnostics of PVS and inverters • Durable UL Type 3R enclosure helps reduce maintenance costs • Easy integration with SunPower eBOS Robust Cloud Connectivity Multiple options to maintain optimal connectivity: • Hardwired Ethernet • WiFi • Cellular backup S U N P q v u,V r lj V , . SunPower° Pro Fleet Management for Installers mySunPowerTM for Homeownes PVS Site Requirements Number of modules . 85 (SunPower AC modules) supported per PVS • High-speed internet access via accessible Internet access router or switch • 100-240 VAC (L-N), 50 or 60 Hz Power . 208 VAC (L-L in phase 3), 60 Hz Operating Conditions • -22°F to +140°F (-30°C to +60°C) Humidity (max.) • 95%, non -condensing Warranty • Certifications Warranty • 10-year Limited Warranty • Certifications UL, cUL, CE, UL 61010-1 and -2, FCC Part 15 (Class B) SunPower° AC Modules Communication • Supports string inverters, external meters, RS-485 and other auxiliary devices Integrated • One channel of revenue -quality production metering metering • Two channels of consumption metering Ethernet • 1 LAN (or optional WAN) port PLC • Supports SunPower AC modules WiFi • 802.11 b/g/n 2.4 GHz and 5 GHz Cellular • LTE Cat-M1/3G UMTS ZigBee • IEEE 802.15.4 MAC, 2.4 GHz ISM band Data storage • 60 days Upgrades • Automatic firmware upgrades Web and Mobile Device Support Customer site • mysunpower.com Partner site • monitor.sunpower.com Browsers • Firefox, Safari, and Chrome Mobile devices • iPhone®, iPad®, and AndroidTM' 1 Create account online at mysunpower.com 2 On a mobile device, download the Customer app SunPower Monitoring app from Apple App Store or Google Playrm Store 3 Sign in using account email and password G�'p5S1Fj�4 U� SUNPOWER° © 2020 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo and MYSUNPOWER are trademarks or registered trademarks of SunPower Corporation in the U.S. and other countries as well. All other logos and trademarks are the properties of their respective owners. sunpower.com 530536 Rev D Product data sheet DU222RB Characteristics Safety switch, general duty, non fusible, 60A, 2 poles, 10 hp, 240 VAC, NEMA 3R, bolt -on provision Product availability : Stock - Normally stocked in distribution facility SQUARES r.�Green -PremlumTM Price*: 353.00 USD Main Product Single Throw Safety Switch Current Rating 60 A Certifications UL listed file E2875 Enclosure Rating NEMA 3R Disconnect Type Non -fusible disconnect switch Factory Installed Neutral None Mounting Type Surface Number of Poles 2 Electrical Connection Lugs Duty Rating Voltage Rating General duty 240 V AC Wire Size AWG 12... AWG 3 aluminium AWG 14... AWG 3 copper Complementary Short-circuit withstand 200 kA Maximum Horse Power Rating 10 hp 240 V AC 60 Hz 1 phase NEC 430.52 Tightening torque 35 Ibf.in (3.95 N.m) 0.00...0.01 in (2.08 ... 5.26 mmz) AWG 14... AWG 10) 35 Ibf.in (3.95 N.m) AWG 14... AWG 10) 45 Ibf.in (5.08 N.m) 0.01 in (8.37 mmz) AWG 8) 45 Ibf.in (5.08 N.m) 0.02...0.03 in (12.3 ... 21.12 mmz) AWG 6... AWG 4) 50 Ibf.in (5.65 N.m) 0.04 in (26.67 mmz) AWG 3) Height 9.63 in (244.60 mm) Width 7.75 in (196.85 mm) Maximum Depth 3.75 in (95.25 mm) ` Price is "List Price' and may be subject to a trade discount — check with your local distributor or retailer for actual price Mar 28, 2021 Kon Schneider 1 Product Data Sheet D222NRB Safety Switch , 60A, Fusible, Cartridge (Class H, K or R), 2-Pole Technical Characteristics Terminal Type Type of Duty Maximum Voltage Rating Wire Size Depth Height Width Action Ampere Rating Approvals Enclosure Rating Enclosure Type Enclosure Material Factory Installed Neutral Fuse Type Disconnect Type Short Circuit Current Rating Mounting Type Number of Poles Shipping and Ordering ® 513UARE D by SChrUe Eder E I cctri c List Price $326.00 USD Availability Stock Item: This item is normally stocked in our distribution facility. Lugs General Duty 240VAC #10 to #2 AWG(AI) - #14 to #2 AWG(Cu) 4.83 Inches 14.88Inches 6.63 Inches Single Throw 60A UL Listed File: E2875 NEMA 3R Rainproof and Sleet/Ice proof (Indoor/Outdoor) Galvannealed Steel Yes Cartridge (Class H, K or R) Fusible 100kA (max. depending on fuse type) Surface 2-Pole Category 00106 - Safety Switch, General Duty, 30 - 200 Amp, NEMA3R Discount Schedule DE1A GTIN 00785901460640 Package Quantity 1 Weight 8.35 lbs. Availability Code Stock Item: This item is normally stocked in our distribution facility. Returnability Y Country of Origin US As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document. Generated: 06/30/2 010 15:53: 57 © 2010 Schneider Electric. All rights reserved. Schneider Electric KUP-L-Tap° Insulation Piercing Connectors C ,`SCO Compliant�� Dual Rated LISTED 19.2435% 923F Features Benefits TYPE • Body is molded from tough, resilient glass -filled nylon •Provides high degree of breakage resistance and long dependable use IPC/ • Compact design • Tin plated copper contact teeth • Insulation •Saves space • Easily penetrates most ty es of insulation • No installation piercing need to strip the conxctor which saves time yv�'Eat • Perforated end tabs • Pre -filled with silicone lubricant • Break out easily by hand • Prevents oxidation and moisture from entering the contact area �c e� • Versatile • Can be used as a splice or tap connector • Increased safety • Contains no external energized parts. Can be installed "hot" on energized conductors providing to conductor is not under load. • Horizontal line grid • Provides a visual guide for proper installation of conductors • Temperature rating 90° C W L Fig. 1 Fig. 2 Fig. 3 Fig. 4 Catalog Number Figure Number Wire Range Volts Current CU Rating AL Dimensions Torque Ft. Lbs. Bolt Head Size Main Tap L W H IPC-1/0-2 3 1/0-8 2-8 300 (480 Grounded Y System) 130 100 1-7/32 1-15/32 2-5/16 16 1/2 IPC-4/0-6 2 4/0-4 6-14 600 75 60 1-27/64 1 1-7/8 13 1/2 IPC-4/0-2/0 4/0-2 2/0-6 600 195 150 1-21/32 1-7/8 2-7/8 25 1/2 IPC-250-4/0 250kcmil-1 4/0-6 600 260 205 1-7/8 2-11/32 3-11/32 30 5/8 IPC-350-4/0 350kcmil-4/0 4/0-10 300 (480 Grounded Y System) 260 205 1-43/64 2-7/16 3-1/8 25 5/8 IPC-350-350 350kcmil-4/0 350kcmil-4/0 300 (480 Grounded Y System) 350 280 2-43/64 2-23/32 3-1/4 25 5/8 IPC-500-12 500kcmil-250kcmil 10-12 300 (480 Grounded Y System l 40 35 1-43/64 2-7/16 3-1/4 25 5/8 IPC-500-250 500kcmil-250kcmil 250kcmil-4 600 290 230 2-27/64 2-29/32 3-3/4 55 5/8-11/16 IPC-500-500 500kcmil-300kcmil 500kcmil-250kcmil 600 430 350 3-3/16 3-5/8 5 75 7/8-7/8 IPC-750-500 750kcmil-500kcmil 500kcmil-350kcmil 1 600 430 350 3-3/16 3-5/8 5 75 7/8-7/8 All wire sizes, unless noted otherwise, are American Wire Gauge (AWG) Tested to UL 486A/B, UL File E6207 4730 Madison Road, Cincinnati, Ohio 45227-1426 Phone 513 533-6200 Fax 513 871-4084 Web site www.ilsco.com Canada 1050 Lakeshore Road East, Mississauga, Ontario, Canada L5E1E4 Phone 905 274-2341 Fax 905 274-8763 224