HomeMy WebLinkAboutGRID TIED PHOVOLTAIC SYSTEMCODE INFORMATION
U
� a
ULJ
w o �
SOLAR INDIVIDUAL PERMIT PACKAGE
Y a
�a
�a�
APPLICABLE CODES, LAWS AND REGULATIONS
2020 7TH EDITION FLORIDA BUILDING CODE (FBC)
o D v v
2020 FLORIDA FIRE PREVENTION CODE (FFPC)
o °
z
2017 NATIONAL ELECTRIC CODE (NEC)
2020 FLORIDA ENERGY CODE (FEC)
a o
" a
RAYMOND SMITH
a U
o�
Digitally signed by
Heinrich Heinrich Villanueva
7.60 kW GRID TIED PHOTOVOLTAIC SYSTEM
Villanueva°60;44z08'0o''
AC SYSTEM SIZE = 6.91 KW
SATELLITE IMAGE
7723439763
PROJECT LOCATION
5771 TRAVELERS WAY
FORT PIERCE, FLORIDA 34982
AHJ : ST. LUCIE COUNTY
UTILITY: FLORIDA POWER & LIGHT CO
JOB NOTES
SHEET INDEX
LU
V)
00
LU
Y
SCOPE OF WORK
PV SOLAR ARCHITECTURAL DRAWINGS
- (N) 7.600 KW PHOTOVOLTAIC SYSTEM
PVA-0 COVER SHEET
PVA-1 ARRAY LAYOUT
= Q
Q m
Q
Q
- (19) 40OW (MODEL SPR-A-400-G-AC) PV MODULES
0
U) 0
0
c
LU 0
LU
w
- POINT OF INTERCONNECTION AT MAIN SERVICE PANEL
°
Q w
LU
Q w
WITH LINE SIDE TAP
� w
o 0
Q�
in� o
��
In
>
o
SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEC2017, NFPA70 AND THOSE SET
PV SOLAR STRUCTURAL DRAWINGS
�
3
�
z
g
FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDING MAXIMUM NUMBER OF MODULE STRINGS,
PVS-1 MOUNTING DETAILS
o
00
MAXIMUM NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODEL NUMBER,
INTERVTER MANUFACTURER AND MODEL NUMBER, AS APPLICABLE
REVISIONS
REV
DESCRIPTION
DATE
DB
SYSTEM CONTAINS SAME INFORMATION WITHIN FSEC CERTIFICATION:
MAXIMUM NUMBER OF MODULE BRANCHES: 2 BRANCHES
PV SOLAR ELECTRICAL DRAWINGS
MAXIMUM NUMBER OF MODULES PER BRANCH: 10 MODULES
PVE-1 ELECTRICAL SINGLE -LINE DIAGRAM &
DRAWN BY:
MAXIMUM OUTPUT PER MODULE: 349W, 1.45A @240V
SPECIFICATIONS
MODULE MANUFACTURER AND MODEL NUMBER: SUNPOWER (SPR-A400-G-AC)
PVE-2 ELECTRICAL CALCULATION
crPeISTI/YlI FULGENCIO
INVERTER MANUFACTURER AND MODEL NUMBER: SUNPOWER (IQ7AS-66-ACM-US)
PVE-3 ELECTRICAL DATA & SPECIFICATIONS
PVE-4 EQUINOX GROUNDING DETAILS
INSTALLER
SKY SOLAR ENERGY IN
PROJECT
RP-183683
DATE DRAWN
11-10-2021
FSEC REGISTRATION NUMBER: 401075
PVE-5 BRANCH DIAGRAM
SCALE
NTS
SHEET
PVA-0
L E G E N D
0 JUNCTION BOX
CONDUIT
UTILITY SERVICE POINT
AND METERING
PROPERTY LINE
��� FIRE ACCESS PATHWAY
65'-7"
ROOF ACCESS
POINT N1C NEW LOAD CENTER
AC DISCONNECT
I ROOF ACCESS
POINT
❑
D
(E) GARAGE G
rn
36" / V /
T C NOTE:
1. FIELD ADJUSTMENTS OF FEWER THAN 6"
FM
----- — D MAY BE ALLOWED BASED ON SITE
___________ ___________ ` CONDITIONS AND MEASUREMENTS.
F[ 2. DESIGN WIND SPEED = 159 MPH
Li I
ROOF
1
1 2
MODULE
QTY.
17
2
AZIMUTH
180°
271°
PITCH
4.5:12
4.5:12
CONTRACT MODULE
19 SPR-A400-G-AC (240)
& QUANTITY
MICROINVERTER
19 IQ7A5-66-ACM-US (240)
TYPE & QUANTITY
ROOF TYPE
COMP SHINGLE
N
ROOF ATTACHMENT
70
QUANTITY
STORY
1 -STORY
HOME TYPE
TOTAL
388 SQ.FT.
ARRAY AREA
W
(D
N
00
<
U
~
cn 2
W o
W
g
W LL
a
J
}
LLI
U
,--i W
� a
�
�
z
O
LL
J
O
In
REVISIONS
DESCRIPTION
DRAWN BY:
C♦ ISTI FULGENCIO
INSTALLER SKY SOLAR ENERGY IN
PROJECT RP-183683
DATE DRAWN 11-10-2021
SCALE 1/16" = 1'-0"
SHEET
PVA-1
In
LLJ W o
0
Ln u v o
> > v
3 Ln
a o
4 A z K U o
4 A O v
o "
�- m z
a � o
Z a
o = _
a O
O W
(j W
N
U_ rn U0J
Q Q M Q H
O ap ~mow
w p � U_ C7
Q W U_ 0-
FIG a Q Lu JJz
U 7)C
QLU ^ a U f
DC p Ln o C z
O V QUL
Q
Y _J
n
REVISIONS
REV DESCRIPTION DATE IDS
DRAWN BY:
CSTI FULGENCI°
INSTALLER SKY SOLAR ENERGY IN
PROJECT RP-183683
DATE DRAWN 11-10-2021
SCALE NTS
SHEET
PVS-1
TABLE 1
-ARRAYS INFORMATION
MAX.
ROOF
ROOFING
ATTACHMENT
NO. OF
FRAMING
PENETRATION
MAX. ATTACHMENT
MAX. RAIL
RAFTER
PITCH
TYPE
TYPE
STORIES
TYPE (in.)
PATTERN (in.)
SPACING (in.)
OVERHANG (in.)
SPAN (ft.)
ROOF 1
21°
Comp Shingle
Pegasus L-foot
1
2x4 Truss @ 24" OC
6'
Staggered
24"
8"
ROOF 2
21°
Comp Shingle
Pegasus L-foot
1
2x4 Truss @ 24" OC
6'
Staggered
24"
8"
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
CHECK TABLE 2 FOR PENETRATION PATTERN GUIDE
FIG 1.1: ROOF 1 STRUCTURAL FRAMING DETAIL
FIGURE 2: INVISIMOUNT ROOF ATTACHMENT
DETAILS @TRUSS RAFTERS
FLASHING
INVISIMOUNT RAIL +� 2�YN
INVISIMOUNT RAIL
PV MODULE
PV MODULE
PV MODULE
HEX CAP
_
COMPOSITION SHINGLES L FOOT
SHINGLE ON TOP OF
FLASHING
l
FLASHING
SHOE ASSEMBLY
z
f
5/16" S.S. LAG BOLT WITH III I" WASHER @
-
CENTER TYP. PRE -DRILL REQUIRED.
EXTERNAL LOAD
2"X4" TRUSS OR RAFTER
(DOUGLAS FIR OR EQUAL)
BEARING WALL
0.75" MIN.
FIGURE 3: MOUNTING CLAMP
FIG 1.2: ROOF 2 STRUCTURAL
FRAMING DETAIL
TABLE 2: PENETRATION GUIDE FOR INSTALL
POSITIONING DETAILS
TWO OR MORE ROWS OF MODULES
FLASHING
2" 11.8" 11.8.
1.8 "y�2"
INVISIMOUNT RAIL
- - _
I 1 1 1 1 1 I I 1 1 --1 I
PV MODULE
I 1 1 1 1 1 I I 1 1 1 1 1 I I 1 1 1
1 I
�00
I 1 1 1 1 1 I I 1 1 1 1 1 I I 1 1 1
1 I
�
I 1 1 1 1 1 I I 1 1 1 1 1 I I 1 1 1
1 I
( I ICI
O
STACKED STAGGERED FULLY STAGGERED
OOOOO
�
��
w
z
00000
O
ONE ROW OF MODULES
00000
00000
EXTERNAL LOAD
BEARING WALL
66CELLMODULE
FULLY STAGGERED STACKED/STAGGERED
• RAILS SHALL BE POSITIONED IN THE NON -CROSS
HATCHED REGIONS
*CHECK TABLE 1 FOR MAX.. PENETRATION SPACING AND PENETRATION PATTERN FOR EACH ARRAY.
m
� a
LUw
O o
� a o
O o
z
o
m z
Z
Q � O o
a Q �
O = _
a M
cC �O
�
^
p a
LU
((f
LU
r
N
(D
U_
rn
U0J
W
Q
Lnof cj�
0
(� p
LUO
LL C7
J J
LU -
Lu Z Z
Z =
>
-i
a
< Lu
QQZ
cl�U
D
Q
^ a
U
p
� Z
O
VQ
L
Q
Y
J
o
O
U)
n
REVISIONS
REV
DESCRIPTION
DATE
DB
DRAWN BY:
C RISTIK� FULGENCIO
INSTALLER
SKY SOLAR ENERGY IN
PROJECT
RP-183683
DATE DRAWN
11-10-2021
SCALE
NTS
SHEET
PVS-2
e
SUNPOWER MODULES
SPR-A400-G-AC (240)
MICROINVERTER MODEL:
IQ7AS-66-ACM-US (240)
ROOFTOP
ARRAY WIRING
Bran
, 9 Circuit ACDMODULES 1 I
Branc
\ACI
Circuit 110 AChMODULES2
TAG
DESCRIPTION
0
SOLAR AC MODULE / BRANCH
Q
DC / DC CONVERTERS
Q3
SOURCE CIRCUIT JUNCTION BOX
®
SEPARATE DC DISCONNECT
INTERNAL INVERTER DC DISCONNECT
©
STRING INVERTER
SOLAR LOAD CENTER
®
PV PRODUCTION METER
A
SEPARATE AC DISCONNECT
ACM
NO
YES
NO
NO
NO
YES
NO
YES
PV CERTIFICATIONS AND COMPLIANCE
• UL 1741 / IEEE-1547
• UL 1741 AC MODULE (TYPE 2 FIRE RATED)
• UL 62109-1 / IEC 62109-2
• UL LISTED PV RAPID SHUTDOWN EQUIPMENT
ENABLES INSTALLATION IN ACCORDANCE WITH:
• NEC 690.6 (AC MODULE)
• NEC 690.12 RAPID SHUTDOWN (INSIDE AND OUTSIDE
THE ARRAY)
• NEC 690.15 AC CONNECTORS, 690.33(A)-(E)(1)
A
(N) SOLAR LOAD CENTER
A 100A MIN., 120/240 V,
M.L.O, NEMA-311
JUNCTION BOX, LOCATION: EXTERIOR WALL
NEMA-3R
0
F MLO� r
I Or�P
I�L2�' " 15�2P
FIGURE A: SINGLE LINE DIAGRAM - 7.60 kW
ETHERNET
CONNECTION TO
DSL/CABLE MODEM
CAT5e -4
�VS66
(3) #14 THWN
(1) #14 THWN EGC
40A
-J��PN-G BOND INSIDE
D AC DISCO
9
UTILITY -LOCKABLE SAFETY SWITCH 60A, 240VAC
SQUARE D D222NRB OR EQUIVALENT
LOCATED OUTSIDE
WITH VISIBLE KNIFE BLADES
CONDUCTOR / CONDUIT SCHEDULE
DESCRIPTION &
CONDUCTOR SIZE
NUMBER OF
TAG
CONDUCTOR TYPE
(AWG)
CONDUCTORS
SUNPOWER PROVIDED AC MODULES EXTENSION
CABLE, LISTED AS AN ASSEMBLY
#12
2
❑A
EGC: BARE Cu
#6
1
THWN-2
#10
4
B
EGC: THWN-2
#10
1
THWN-2
#8
3
❑
EGC: THWN-2
#10
1
THWN-2
#6
3
D
❑
GEC: THWN-2
#6
1
INCOMING SOURCE FEED
(E) MAIN SERVICE PANEL
MANUF:SQUARE D
150A, 120/240 V, 1 PH, 3 W
LOCATION: INSIDE GARAGE
LINE SIDE TAP
F
z
F(E)
~
UTILITY
ILSCO KUP-L-TAP
BIDIRECTIONAL
IPC-4/0-6
PV DISCONNECT
I
W
METER #:
I ACD8515
LOCATED WITHIN
FROM THIS TAPAP
Digitally signed
C h I
MCB
150A, 2P
ftj
H
\/
by Chi F Leung
TO
1
� �
Date: 2021.11.11
Leung 16:52:54 08'00'
EXISTING
I
I
�
I
LOADS
E
C
This item has been signed and
sealed by Chi Fung Leung, PE on the
date and / or time stamp shown
using a digital signature.
Jnot
I
Printed copies of this document are
considered signed and sealed
and the signature must be verified
—
on any electronic copses.
EXISTING
GROUND —
ELECTRICAL NOTES
ONDUIT/CABLE TYPE
CONDUIT SIZE
1. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC.
2. ALL CONDUIT BEND RADII TO CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS.
BRANCH CIRCUIT
FROM PV ARRAY TO
__
3. MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENT TO BE INSTALLED.
JUNCTION BOX
4. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS.
5. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.
6. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING NEC REQUIREMENTS.
EMT
3/4"
7. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY 3RD PARTY.
8. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.
9. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT.
EMT
3/4"
10. EQUIVALENT SPECIFICATION ON CABLES AND ELECTRICAL EQUIPMENT SPECIFIED ARE ACCEPTABLE.
11. AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED.
EMT
3/4"
AC MODULES NOTES
1. DC CIRCUIT IS ISOLATED AND INSULATED FROM GROUND AND MEETS THE REQUIREMENT OF NEC 690.35.
2. SUNPOWER PROVIDED CABLES COMES WITH TWO (2) #12 AWG WIRE AND THIS IS BY DESIGN. NEUTRAL AND ADDITIONAL GROUND WIRE
IS NOT REQUIRED FOR PROVIDED TRUNK AND EXTENSION CABLES.
3. SUNPOWER AC MODULES HAVE BEEN TESTED AND CERTIFIED TO UL 2703 FOR INTEGRATED GROUNDING AND HENCE A SEPARATE GROUND
WIRE IS NOT REQUIRED WITHIN THE ARRAY.
4. USE ROW -TO -ROW GROUNDING CLIP PROVIDED TO GROUND ROWS OF MODULE. BOND SUB -ARRAYS BY RUNNING #6 AWG BARE CU WIRE
AND GROUND LUGS AT A SINGLE POINT ON EACH SUB -ARRAY AND THEN TO THE JUNCTION BOX. REFER TO PVE-4 FOR ADDITIONAL
DETAILS.
w
LU
V)
N
Q
00
It
= Q
~
>Q
Q
Q
a
>
�_
w Z
-ZO
(n O
W
CL
J H
~O
w
LL
0- -1 V
0 a
Q
Lu
JZ U
p
U
w
Q
a
>QN
LL
gW
Lu
Ow
�
n
1 EVISIONS I
REV DESCRIPTION DATE DB
DRAWN BY: �p
CgRISTI F/YFI PULGENCIO
INSTALLER SKY SOLAR ENERGY IN
PROJECT RP-183683
DATE DRAWN 11-10-2021
SCALE NTS
PVE-1
9.
x
N H
�
ELECTRICAL CALCULATIONS
W
x a
U,v, o
3 a �
O
z
u
O
a o
z
K a ti
O = x V
a O
O
' ^
V
This item has been signed and
sealed by Chi Fung Leung, PE on the
date and / or time stamp shown
using a digital signature.
Printed copies of this document are
not considered signed and sealed
and the signature must be verified
on any electronic copies.
w
U)
w
U)
00
Q
U
M
Y z
2
J
Q M
Q
a
g
O
2
W O
W J
p
> LL
a- U
Tz
p a-
a L
a Q
0
H �
=p U
LU
Q ~
a
tY
u^i
z w
O
(D
LL
Q
�C
J
U)
R E V I S I O N S
REV
DESCRIPTION
DATE
DB
DRAWN BY:
C RISTI FULGENCIO
INSTALLER
SKY SOLAR ENERGY IN
PROTECT
RP-183683
DATE DRAWN
11-10-2021
SCALE
NTS
SHEET
PVE-2
SUBPANEL TO GRID -TIE WIRING
#8
VOLTAGE
240 V
SUM OF BRANCHES: lOUT-TOTAL =
27.55 A
MINIMUM WIRE AMPACITY: 'MAX = IOUT x 1.25
34.44 A
CONDUCTOR DE -RATING
MAXIMUM AMBIENT TEMPERATURE
35 °C
TEMPERATURE USED FOR AMPACITY DE -RATING
35 °C
TEMPERATURE DE -RATING COEFFICIENT
0.96
FILL DE -RATING COEFFICIENT
1.00
lwiREMiN =IMAx / TEMP_COEFF / FILL_COEFF
35.87 A
WIRE SIZE AMPACITY
55 A
CONDUCTOR SIZE
#8
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP
#8
ONE WAY CIRCUIT LENGTH
15 FT.
VOLTAGE DROP
0.27%
OVERCURRENT PROTECTION
40A, 2P
MINIMUM OCPD = lour x 1.25
34.44 A
BRANCH1
BRANCH2
ROOF JCT BOX TO SUBPANEL WIRING
#10
#10
NUMBER OF MODULES
9
10
VOLTAGE
240 V
240 V
RATED AC OUTPUT CURRENT: lour =
13.05 A
14.5 A
MINIMUM WIRE AMPACITY: IMAx = lour x 1.25
16.31 A
18.13 A
CONDUCTOR DE -RATING
MAXIMUM AMBIENT TEMPERATURE
35 °C
35 °C
TEMPERATURE ADDER
22 °C
22 °C
TEMPERATURE USED FOR AMPACITY DE -RATING
57 °C
57 °C
TEMPERATURE DE -RATING COEFFICIENT
0.71
0.71
FILL DE -RATING COEFFICIENT
0.8
0.8
lwiREMiN = 'MAX / TEMP_COEFF / FILL_COEFF
28.72 A
31.91 A
WIRE SIZE AMPACITY
40 A
40 A
CONDUCTOR SIZE
#10
#10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP
#10
#10
ONE WAY CIRCUIT LENGTH
25 FT.
25 FT.
CALCULATED VOLTAGE DROP
0.34%
0.37%
OVERCURRENT PROTECTION
20A, 2P
20A, 2P
MINIMUM OCPD = lour x 1.25
16.31 A
18.13 A
� a
w
w o
O
WARNING WARNING
o
WARNING
/�
( ,
Q
•- SOURCE
ELECTRIC OSHCKHAZARD POWER
4,/
LL
O
F m z
Q a O o
. . •WER SUPPLY
Z
.�
Q 2
O = _ v
TERMINALS ON. OUTPUT CONNECTION
a v ..
• • • -
. . • • RELOCATE SOURCES: GRID
. : ENERGIZED
LOAD
v l
O z
IN THE OPEN POSITION
NEC 705.12 (B)(3)
NEC 690.13 (B) NEC 705.12 (B)(2)(3)(b)
PLACE ON PV SYSTEM DISCONNECTINS MEANS PLACE ADJACENT TO BACK -FED BREAKER PLACE ON ALL EQUIPMENT THAT IS SUPPLIED BY BOTH
POWER SOURCES
RAPID DOWN PHOTOVOLTAIC POWER SOURCE WARNING
OPERATING VOLTAGE 240 V PHOTOVOLTAIC SYSTEM
SWI OR
This item has been signed and
sealed by Chi Fung Leung, PE on the
MAXIMUM • ' COMBINER PANEL
date and / or time stamp shown
digital
. 55 .
• LAREMAC
using a signature.
- CURRENT
OUTPUT
Printed copies of this document are
not considered signed and sealed
DO NOT ADD LOADS
and the signature must be verified
on any electronic copies.
NEC 690.56 (C)(3) NEC 690.54
PLACE ON RAPID SHUTDOWN SWITCH OR EQUIPMENT PLACE ON INTERCONNECTION DISCONNECTING MEANS
WITH INTEGRATED RAPID SHUTDOWN *REFLECTIVE*
EQUIPMENT LABEL NOTES
1. LABELS SHOWN ARE THEIR
LU
ACTUAL REQUIRED SIZE.
WARNING: PHA OTOVOLTAI(
SOLAR PV SYSTEM EQUIPPED 2. LABEL MATERIAL SHALL BE
SUITABLE FOR
c}iI
^'
w cn
a o
THE EQUIPMENT
POWER SOURCE
u
} �
� r
WITH RAPID SHUTDOWN ENVIRONMENT.
3. CONDUIT SHALL BE MARKED
= Q
p
a R
o
Q _v
WITH REQUIRED LABEL
p
� c
OJ
w
NEC 690.31 (G)(3)&(4) EVERY 10 FEET.
p
w
Uj
a can
PLACE ON ALL JUNCTION BOXES EXPOSED RACEWAYS
0 a
Q LU
Q Q
TURN RAPID SHUTDOWN EVERY 10' AND 1' FROM BENDS AND PENETRATIONS,
g o
U
o Q
ADJACENT TO THE MAIN SERVICE DISCONNECT *REFLECTIVE*
Q
^ a
o
SWITCH TO THE
°�
�
z Q
"OFF" POSITION TO
O
LL
SOLAR PV SYSTEM EQUIPPED
U
Q LU
O)
SHUT DOWN PV SYSTEM WITH RAPID SHUTDOWN
w
ANDREDUCE . • -
REVISIONS
REV
DESCRIPTION
DATE
DB
SHOCK HAZARD
N THE ARRAY
NEC 690.13 (B)
PLACE ON PV SYSTEM DISCONNECTING MEANS
DRAWN BY:
NEC 690.56 (C)(1)(a)
CfISTIA'N FULGE NCIO
INSTALLER
SKY SOLAR ENERGY IN
PLACE WITHIN 3FT OF SERVICE DISCONNECTING MEANS TO
PROJECT
RP-183683
WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL
DATE DRAWN
11-30-2021
INDICATE THE LOCATIONS OF RAPID SHUTDOWN SWITCHES
SALE
NTS
F"T
PVE-3
W w o
3 a o
z�Uo
oCl-
o�
�mZ
Z a o 0
� a �
o = = v
z v
u �100 This item has been signed and
sealed by Chi Fung Leung, PE on the
date and / or time stamp shown
using a digital signature.
Printed copies of this document are
Lee not considered signed and sealed
and the signature must be verified
on any electronic copies.9! its Lu
00 a
U O� Y
Q Q m Q
� Q
0 0
Ln O
o LU o W
O Lu 1,_ a
z a a LLB J
O � a
o F- � o
Lu
Q H a >
tY C Ln Q
O
o a
Y J
o O
U)
r;
REVISIONS
REV DESCRIPTION DATE DB
DRAWN BY:
CWISTI/IfN FULGENCIO
INSTALLER SKY SOLAR ENERGY IN
PROJECT RP-183683
DATE DRAWN 11-10-2021
SCALE NTS
SHEET
PVE-4
SunPower InvisiMount"^with R2R Grounding Clip
Ground Path and Compliance
OUR � Module
r/ �Irp
*
`°
��K•
-xrw
POWER TO THIS BUILDING IS ALSO
�"h
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECT(S)
�
service'
Module N
"�`
LOCATED AS SHOWN:
1 �
Bonding Components
MAIN SERVICE
��,�a�
PANEL
�•«��
E
Grounding Electrode to
�
690.47(A)
Na
GEC a•
Service Panel
690.47(D)
2 Service Panel to
690.43(c)
�7ai
PHOTOVOLTAIC
Ground Wire
ARRAY O N ROOF
Ground Wire to
Ground Lug to
Rail
690.43(C)
2703
SOLAR LOAD
4 Module Frame to
690.43(C)
2703
CENTER
Module Frame
5 Module Frame
n/a
1703
�+
AC --------
- -
C; x
N H
� x a
INSTALLER NAME: w 0
BRANCH VOLTAGES: z
0
1. 0 ^
2. a " 0
O 0
Z 0 a =
= x `^
3. a 0
4. 0
' ^ 5. U vI
6.
This item has been signed and
sealed by Chi Fung Leung, PE on the
date and / or time stamp shown
using a digital signature.
Printed copies of this document are
T not considered signed and sealed
O and the signature must be verified
on any electronic copies.
O
N
w
U) 00 a
U rn Y
= Q Q M Q
g 0 � o
Cn p LU w Q
0 > -i a 0
o < L Q U
Lu H �p Q
— Q ~ ^ a m
tY p Ln
O Q
�C J
0
Ln
R E V I S I O N S
ROOF 1 N-LC [ACD ® REV DESCRIPTION DATE DB
DRAWN BY:
ci s 1..,. ; o
C RISTI FULGENCIO
N INSTALLER SKY SOLAR ENERGY IN
PROTECT RP-183683
DATE DRAWN 11-10-2021
SCALE 19/128" = 1'-0"
SHEET
PVE-5
ROOF
1
2
MODULE
QTY.
17
2
AZIMUTH
180°
271°
PITCH
4.5:12
4.5:12
A -Series: A420 I A415 I A410 I A400 I A390 Sun Power°Residential AC Module
SUNPOWER1111
'
420-390 W Residential AC Module
SunPower° Maxeon°Tech nology
Built specifically for use with the SunPower EquinoxTM system, the only fully
integrated solution designed, engineered, and warranted by one manufacturer.
I❑
Fundamentally Different.
And Better.
SunPower® Maxeon®Technology
• Most powerful cell in home solar z
• Delivers unmatched reliability
• Patented solid metal foundation prevents
breakage and corrosion
Factory -integrated M icroinverter (M I)
• Highest -power integrated AC module
in solar
• 60% lighter than prior SunPower Mls
• Engineered and calibrated by
SunPower for SunPower AC modules
Highest Power Density Available.
Sun Power's new Maxeon° Gen 5 cell is 65% larger than
prior generations, delivering the most powerful cell and
highest -efficiency module in residential solar. The result is
more power per square meter than any commercially
available solar.
E
E
Ln
NI
1
Highest Lifetime Energy and Savings.
Designed to deliver 60% more energy over 25 years in
real -world conditions like partial shade and high temperatures.'
15096
3 140�6
`m
q 13096
= 12016
m
T 110°5
100%
m
G 9045
07
8096
CU
70%
ry 6096
1 5 10 15 20 25
Years of operation
Up to
60%
more
lifetime
energy
Best Reliability. Best Warranty.
With more than 25 million modules deployed around '
the world, SunPower technology is proven to last. That's '•
why we stand behind our module and microinverter
with the industrys best 25-year Combined Power and
Product Warranty, including the highest Power Warranty
in solar.
DC Power Data
A420-G-AC A415-G-AC A410-G-AC A400-G-AC A390-G-AC
Nom. Powers (Pnom) W
420 415 410 400 390
Power Tol.
+5/-0%
Module Efficiency
22.5 22.3 22.0 21.5 20.9
Temp. Coef. (Power)
-0.29%/'C
Shade Tol.
Integrated module -level max. power point tracking
Tested
Operating Temp.
Operating Conditions
-40'F to +185'F (-40'C to +85'C)
Max. Ambient Temp.
122°F (50°C)
Max. Test Load'
Wind: 125 psf, 6000 Pa, 611 kg/m2 back
Snow: 187 psf, 9000 Pa, 917 kg/m2 front
Design Load
Wind: 75 psf, 3600 Pa, 367 kg/mz back
Snow: 125 psf, 6000 Pa, 611 kg/M2 front
Impact Resistance
1 inch (25 mm) diameter hail at 52 mph (23 m/s)
Solar Cells
Vlechanica� Data
66 Monocrystalline Maxeon Gen 5
Front Glass
High -transmission tempered glass with
anti -reflective coating
Environmental Rating
Outdoor rated
Frame
Class 1 black anodized (highest AAMA rating)
Weight
46.5 Ibs (21.1 kg)
Recommended Max.
Module Spacing
1.3 in. (33 mm)
1 SunPower415 W, 22.3% efficient, compared to a Conventional Panel on same -sized
arrays (260 W, 16% efficient, approx. 1.6 m�), 7.9% more energy per watt (based on
PVSyst pan files for avg. US climate), 0.5%/yr slower degradation rate (Jordan, et. al.
"Robust PV Degradation Methodology and Application:" PVSC 2018).
2 Based on search of datasheet values from websites of top 10 manufacturers per IHS, as of
January2019.
3#1 rank in"FraunhoferPV Durability Initiativefor Solar Modules: Part K' PVrech Power
Magazine, 2015,Campeau,Z.etal."SunPowerModule Degradation Rate;' Sun Powerwhite
paper,2013.
4 Factory set to 1547a-2014 default settings. CA Rule 21 default settings profile set during
commissioning.
5 Standard Test Conditions(1000 W/m2 irradiance, AM 1.5, 25'C). NREL calibration standard:
SOMS current, LACCS FF and voltage. All DC voltage is fully contained within the module.
6 This product is UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12;
and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors;
when installed according to manufacturer's instructions.
7 Please read the safety and installation instructions for more information regarding load
ratings and mounting configurations.
See www.sunpower.com/facts for more reference information.
For more details, see extended datasheet www.sunpower.com/datasheets Specifications
included in this datasheetare subjectto change without notice.
©2020 Su nPower Corporation. All Rights Reserved, SUN POWER, the SUNPOWER logo,
Equinox, and MAXEON are registered trademarks of SunPower Corporation in the U.S. and
other countries as well. 1-800-SUNPOWER.
Warranties
25-year limited power warranty
25-year limited product warranty
UL1703
Certifications
UL 1741 / IEEE-1547
and
UL 1741 AC Module (Type 2 fire rated)
Compliance
UL 62109-1 / IEC 62109-2
FCC Part 15 Class B
ICES-0003 Class B
CAN/CSA-C22.2 NO. 107.1-01
CA Rule 21 (UL 1741 SA)4
(includes Volt/Var and Reactive Power Priority)
UL Listed PV Rapid Shutdown Equipment'
Enables installation in accordance with:
NEC 690.6 (AC module)
NEC 690.12 Rapid Shutdown (inside and outside the array)
NEC 690.15 AC Connectors, 690.33(A)-(E)(1)
When used with InvisiMount racking and InvisiMount accessories
(UL 2703):
Module grounding and bonding through InvisiMount
Class A fire rated
When used with AC module Q Cables and accessories (UL 6703 and
UL 2238)6:
• Rated for load break disconnect
PID Test Potential -induced degradation free
72.2 (1835)
. B
Long side 1.3 (32)
B
• Short side 0.9 (24)
U RIENIT,
L
LISTED E4-0
Module Fire Performance: Type 2 SUNPCWER
Please read the Safety and Installation Instructions 532628 for additional details.
534092 RevB
PEGASUS
SOLAR'"
Simple 3-piece design
for rapid installation
IN
One-piece flashing with elevated cone - No
press -fits or deck -level EPDM washers to fail
WATERTIGHT FOR LIFE
�l
El
A BETTER DAY ON THE JOB
Encapsulating design
raises the water seal
0.9" above roof deck
Pegasus Solar's Comp Mounts are a cost effective, high -quality option for rail installations on composition shingle roofs.
Designed to last decades, the one-piece flashing with elevated cone means there is simply nothing to fail.
1. Drill pilot hole in
center of rafter.
3. Place L-Foot over
cone and install lag
with washer through
L-Foot.
5" 93.5"
2.3"
2. Optional: Apply a
"U-shape" of sealant
to underside of
flashing and postition
under 2nd shingle
course, cone over
pilot hole.
4. Drive lag to required
depth. Attach rail per
rail manufacturer's
instructions.
3.5"
!0.91,
�- 2.3" 2.4"
rry
Specifications
SKU
PSCR-CBBO
PSCR-UBBO
Comp Mount Install Kits
SPCR-CBBH
PSCR-CMMO
PSCR-UMMO
Finish
Black L-Foot and Black Flashing
Mill L-Foot and Mill Flashing
L-Foot Type
Closed Slot
Open Slot
Closed Slot
Closed Slot
Open Slot
L-Foot, Flashing,
L-Foot, Flashing,
L-Foot, Flashing,
L-Foot, Flashing,
L-Foot, Flashing,
5/16"x 4-1/2" SS Lag
5/16"x 4-1/2" SS Lag
5/16"x 4-1/2" SS Lag5/16"x
4-1/2" SS Lag
5/16"x 4-1/2" SS Lag
Kit Contents
with metalized
with metalized
with metalized
with metalized
with metalized
EPDM washer
EPDM washer
EPDM washer and
EPDM washer
EPDM washer
M10 Hex Bolt
Roof Type
Composition Shingle
Certifications
IBC, ASCE/SEI 7-16, AC286
Install Application
Railed Systems
Compatible Rail
Most
Flashing Material
Painted Galvalume Plus
Galvalume Plus
L-Foot Material
Aluminum
24
72
Kit Quantity
Simple and Fast Installation
Integrated module -to -rail grounding
Pre -assembled mid and end clamps
Levitating mid clamp for easy placement
Mid clamp width facilitates consistent, even
module spacing
UL 2703 Listed integrated grounding
Flexible Design
Addresses nearly all sloped residential roofs
Design in landscape and portrait with up to 8'
rail span
Pre -drilled rails and rail splice
Rails enable easy obstacle management
Customer -Preferred Aesthetics
#1 module and #1 mounting aesthetics
Best -in -class system aesthetics
Premium, low -profile design
Black anodized components
Hidden mid clamps and capped, flush
end clamps
Part of Superior System
Built for use with SunPower DC and AC modules
Best -in -class system reliability and aesthetics
New optional rooftop transition flashing, rail -
mounted J-box, and wire management rail clips
Combine with SunPower modules and
SunPower EnergyLinkO monitoring app
Elegant Simplicity
SunPower° InvisiMountlm is a SunPower-designed
rail -based mounting system. The InvisiMount system
addresses residential sloped roofs and combines faster
installation time, design flexibility, and superior aesthetics.
The InvisiMount product was specifically envisioned and
engineered to pair with SunPower modules. The resulting
system -level approach amplifies the aesthetic and
installation benefits —for homeowners and for installers.
sunpower.com
U`
InvisiMount Components
Module' / Mid Clamp and Rail Module' / End Clamp and Rail
Mid Clamp End Clamp
Rail & Rail Splice
sow
Mid clamp
InvisiMount ComponentDetails
Black oxide stainless steel 300 series
63 g (2.2 oz)
End clamp
Black anodized aluminum 6000 series
110 g (3.88 oz)
Rail
Black anodized aluminum 6000 series
830 g/m (9 oz/ft)
Rail splice
Aluminum alloy 6000 series
830 g/m (9 oz/ft)
Rail bolt
M10-1.5 x 25 mm; DIN 933 SS304
nominal
Rail nut
M10-1.5; DIN 6923 S5304
nominal
Ground lug
assembly
SS304; A2-70 bolt; tin-plated copper lug
106.5 g/m (3.75 oz)
InvisiMount
Mid clamp
Componentapa
Uplift
664 Ibf
Shear
540 Ibf
End clamp
Uplift
899 Ibf
Shear
220 Ibf
Rail
Moment: upward
548 Ibf-ft
Moment: downward
580 Ibf-ft
Rail splice
Moment: upward
548 Ibf-ft
Moment: downward
580 Ibf ft
L-foot
Uplift
1000 Ibf
Shear
390 Ibf
Ground Lug Assembly (for DCsystems only)
InvisiMount Operating Conditions
Temperature -40° C to 90° C (-40° F to 194° F)
Max. Load (LRFD) . 3000 Pa uplift
6000 Pa downforce
Roof Attachment Hardware Supported by Design Tool
Composition Shingle Rafter Attachment
Application Composition Shingle Roof Decking Attachment
Curved and Flat Tile Roof Attachment
Universal interface for other roof attachments
25-year product warranty
Warranties
5-year finish warranty
Certifications
UL 2703 Listed
Class A Fire Rated
Roof Attachment Hardware
Refer to roof attachment hardware manufacturer's documentation.
1 MOC -. _ -.. _ _. _ _ _ _ _ , _ _ _ _ _ _ _ _ _ _ _, _ _ _ _ _, _ _ _ _ Jware interoperability
z SunPower recommends that all EquinoxT" InvisiMountTm, and AC module systems always be designed using the SunPower Design Tool. If a designer decides to
instead use the component capacities listed in this document to design a system, note that the capacities shown are Load and Resistance Factor Design (LRFD)
design loads, and are NOT to be used for Allowable Stress Design (ASD) calculations; and that a licensed Professional Engineer (PE) must then stamp all calculations.
Should you have any questions please contact SunPower Technical Support at 1-800-SUNPOWER (1-800-786-7693).
sunpower.com
© 2017 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, EQUINOX, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. 509506 RevF
All other trademarks are the property of their respective owners. Specifications included in this datasheet are subject to change without notice.
Improve Support,
Reduce Costs
An intuitive monitoring website
enables you to:
• See a visual map of
customer sites
• Remotely manage hundreds
of sites
• Remotely diagnose and
troubleshoot system issues
• Drill down for the status of
individual devices
Add Value
for Customers
With mySunPower'll monitoring
customers can:
• Track their energy production
by day, month, year and in
different weather conditions
• See their energy use and
estimated bill savings
• Maximize their savings with
automatic system alerts and tips
• Customize storage settings
and easily monitor and track
available battery power
• Receive elective system reports
SunPower° Monitoring —
Plug -and -Play Installation
This complete solution for residential monitoring and control includes the
SunPower® PV Supervisor (PVS) which improves the installation process, overall
system reliability, and customer experience:
• Compact footprint for improved aesthetics
• Robust cloud connectivity and comprehensive local connectivity
• Flexible configuration of devices during installation
• Consumption metering
• Revenue -quality production metering
• Web -based commissioning
• Remote diagnostics of PVS and inverters
• Durable UL Type 3R enclosure helps reduce maintenance costs
• Easy integration with SunPower eBOS
Robust Cloud Connectivity
Multiple options to maintain optimal connectivity:
• Hardwired Ethernet
• WiFi
• Cellular backup
S U N P
q
v u,V r lj V , .
SunPower° Pro Fleet
Management for Installers
mySunPowerTM for
Homeownes
PVS
Site Requirements
Number
of modules
. 85 (SunPower AC modules)
supported
per PVS
• High-speed internet access via accessible
Internet access
router or switch
• 100-240 VAC (L-N), 50 or 60 Hz
Power
. 208 VAC (L-L in phase 3), 60 Hz
Operating Conditions • -22°F to +140°F (-30°C to +60°C)
Humidity (max.) • 95%, non -condensing
Warranty • Certifications
Warranty • 10-year Limited Warranty
• Certifications UL, cUL, CE, UL 61010-1 and -2, FCC Part 15
(Class B)
SunPower° AC Modules
Communication
• Supports string inverters, external meters,
RS-485
and other auxiliary devices
Integrated
• One channel of revenue -quality
production metering
metering
• Two channels of consumption metering
Ethernet
• 1 LAN (or optional WAN) port
PLC
• Supports SunPower AC modules
WiFi
• 802.11 b/g/n 2.4 GHz and 5 GHz
Cellular
• LTE Cat-M1/3G UMTS
ZigBee
• IEEE 802.15.4 MAC, 2.4 GHz ISM band
Data storage
• 60 days
Upgrades
• Automatic firmware upgrades
Web and Mobile Device Support
Customer site • mysunpower.com
Partner site
• monitor.sunpower.com
Browsers
• Firefox, Safari, and Chrome
Mobile devices
• iPhone®, iPad®, and AndroidTM'
1 Create account online at mysunpower.com
2 On a mobile device, download the
Customer app
SunPower Monitoring app from Apple App
Store or Google Playrm Store
3 Sign in using account email and password
G�'p5S1Fj�4
U� SUNPOWER°
© 2020 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo and
MYSUNPOWER are trademarks or registered trademarks of SunPower Corporation in the
U.S. and other countries as well. All other logos and trademarks are the properties of their
respective owners.
sunpower.com
530536 Rev D
Product data sheet DU222RB
Characteristics Safety switch, general duty, non fusible, 60A,
2 poles, 10 hp, 240 VAC, NEMA 3R, bolt -on
provision
Product availability : Stock - Normally stocked in distribution facility
SQUARES r.�Green
-PremlumTM
Price*: 353.00 USD
Main
Product
Single Throw Safety Switch
Current Rating
60 A
Certifications
UL listed file E2875
Enclosure Rating
NEMA 3R
Disconnect Type
Non -fusible disconnect switch
Factory Installed Neutral
None
Mounting Type
Surface
Number of Poles
2
Electrical Connection
Lugs
Duty Rating
Voltage Rating
General duty
240 V AC
Wire Size
AWG 12... AWG 3 aluminium
AWG 14... AWG 3 copper
Complementary
Short-circuit withstand
200 kA
Maximum Horse Power Rating
10 hp 240 V AC 60 Hz 1 phase NEC 430.52
Tightening torque
35 Ibf.in (3.95 N.m) 0.00...0.01 in (2.08 ... 5.26 mmz) AWG 14... AWG 10)
35 Ibf.in (3.95 N.m) AWG 14... AWG 10)
45 Ibf.in (5.08 N.m) 0.01 in (8.37 mmz) AWG 8)
45 Ibf.in (5.08 N.m) 0.02...0.03 in (12.3 ... 21.12 mmz) AWG 6... AWG 4)
50 Ibf.in (5.65 N.m) 0.04 in (26.67 mmz) AWG 3)
Height
9.63 in (244.60 mm)
Width
7.75 in (196.85 mm)
Maximum Depth
3.75 in (95.25 mm)
` Price is "List Price' and may be subject to a trade
discount — check with your local distributor or retailer for actual price
Mar 28, 2021
Kon Schneider 1
Product Data Sheet D222NRB
Safety Switch , 60A, Fusible, Cartridge (Class H, K
or R), 2-Pole
Technical Characteristics
Terminal Type
Type of Duty
Maximum Voltage Rating
Wire Size
Depth
Height
Width
Action
Ampere Rating
Approvals
Enclosure Rating
Enclosure Type
Enclosure Material
Factory Installed Neutral
Fuse Type
Disconnect Type
Short Circuit Current Rating
Mounting Type
Number of Poles
Shipping and Ordering
® 513UARE D
by SChrUe Eder E I cctri c
List Price $326.00 USD
Availability Stock Item: This item is normally stocked in our distribution facility.
Lugs
General Duty
240VAC
#10 to #2 AWG(AI) - #14 to #2 AWG(Cu)
4.83 Inches
14.88Inches
6.63 Inches
Single Throw
60A
UL Listed File: E2875
NEMA 3R
Rainproof and Sleet/Ice proof (Indoor/Outdoor)
Galvannealed Steel
Yes
Cartridge (Class H, K or R)
Fusible
100kA (max. depending on fuse type)
Surface
2-Pole
Category 00106 - Safety Switch, General Duty, 30 - 200 Amp, NEMA3R
Discount Schedule DE1A
GTIN 00785901460640
Package Quantity 1
Weight 8.35 lbs.
Availability Code Stock Item: This item is normally stocked in our distribution facility.
Returnability Y
Country of Origin US
As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document.
Generated: 06/30/2 010 15:53: 57
© 2010 Schneider Electric. All rights reserved. Schneider
Electric
KUP-L-Tap°
Insulation Piercing
Connectors C
,`SCO
Compliant��
Dual Rated
LISTED 19.2435%
923F
Features
Benefits
TYPE
• Body is molded from tough, resilient glass -filled nylon •Provides high degree of breakage resistance and long dependable use
IPC/
• Compact design
• Tin plated copper contact teeth
• Insulation
•Saves space
• Easily penetrates most ty es of insulation
• No installation
piercing
need to strip the conxctor which saves time
yv�'Eat
• Perforated end tabs
• Pre -filled with silicone lubricant
• Break out easily by hand
• Prevents oxidation and moisture from entering the contact area
�c e�
• Versatile
• Can be used as a splice or tap connector
• Increased safety
• Contains no external energized parts. Can be installed "hot" on energized
conductors providing to conductor is not under load.
• Horizontal line grid
• Provides a visual guide for proper installation of conductors
• Temperature rating 90° C
W L
Fig. 1 Fig. 2 Fig. 3 Fig. 4
Catalog
Number
Figure
Number
Wire
Range
Volts
Current
CU
Rating
AL
Dimensions
Torque
Ft. Lbs.
Bolt Head
Size
Main
Tap
L
W
H
IPC-1/0-2
3
1/0-8
2-8
300 (480 Grounded Y System)
130
100
1-7/32
1-15/32
2-5/16
16
1/2
IPC-4/0-6
2
4/0-4
6-14
600
75
60
1-27/64
1
1-7/8
13
1/2
IPC-4/0-2/0
4/0-2
2/0-6
600
195
150
1-21/32
1-7/8
2-7/8
25
1/2
IPC-250-4/0
250kcmil-1
4/0-6
600
260
205
1-7/8
2-11/32
3-11/32
30
5/8
IPC-350-4/0
350kcmil-4/0
4/0-10
300 (480 Grounded Y System)
260
205
1-43/64
2-7/16
3-1/8
25
5/8
IPC-350-350
350kcmil-4/0
350kcmil-4/0
300 (480 Grounded Y System)
350
280
2-43/64
2-23/32
3-1/4
25
5/8
IPC-500-12
500kcmil-250kcmil
10-12
300 (480 Grounded Y System l
40
35
1-43/64
2-7/16
3-1/4
25
5/8
IPC-500-250
500kcmil-250kcmil
250kcmil-4
600
290
230
2-27/64
2-29/32
3-3/4
55
5/8-11/16
IPC-500-500
500kcmil-300kcmil
500kcmil-250kcmil
600
430
350
3-3/16
3-5/8
5
75
7/8-7/8
IPC-750-500
750kcmil-500kcmil
500kcmil-350kcmil
1 600
430
350
3-3/16
3-5/8
5
75
7/8-7/8
All wire sizes, unless noted otherwise, are American Wire Gauge (AWG)
Tested to UL 486A/B, UL File E6207
4730 Madison Road, Cincinnati, Ohio 45227-1426 Phone 513 533-6200 Fax 513 871-4084 Web site www.ilsco.com
Canada 1050 Lakeshore Road East, Mississauga, Ontario, Canada L5E1E4 Phone 905 274-2341 Fax 905 274-8763 224