HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET Llo
Cccct ST. LUCIE WORKS
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code-Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Required Sections of Attachments Required
Roof System the Permit Application See List Below
Form
Low Slope Application A, B,C 1,2,3,4,5,6,7
Prescriptive BUR-RAS 150 A, B,C 2,4,5,6,7
Asphaltic Shingles A, B, D 1,2,4,5,6,7
Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7
Metal Roofs A, B, D 1,2,3,4,5,6,7
Wood Shingles and A, B, D IA4,5,6,7
Shakes
Other As Applicable 1,2,3,4,5,6,7
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16,or if applicable, RAS 127 or RAS 128
4. Other Component of Product Approval
S. Municipal Permit Application
6. Owners Notification for Roofing Considerations(Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18,2021
ST. LUCIE
Section A (General Information)
Master Permit No. Process No.
Contractors Name: Sunrise City CHDO Inc License# CCC1327208
Job Address 3115 Duban Ter Fort Pierce, FL 34982
ROOF CATEGORY
ZLow Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles
Asphaltic Shingles ❑Metal Panel/Shingles ❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ New roof ❑ Repair ❑ Maintenance Fv-(]Reroofing ❑Recovering
1416 ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) 1416
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
1
q-
ST LUCIE
Section C (Low Slope Roof) Surfacing:
Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
manufacturer Zone 1':—" oc @ Lap,#Rows @ "ac
(If a component is not used, identify as"NA") Zone 1:—" oc @ Lap,# Rows @ "ac
System Manufacturer: Polyglass Zone 2:—" oc @ Lap,# Rows @ "ac
Product Approval No.:
FL1654 Zone 3:—" oc @ Lap,# Rows @ "ac
Number of Fasteners Per Insulation Board:
Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3:
Zone 1': -37.8 Zone 1: -37.8 Zone 2: -63.5 Zone 3: -95.2 Illustrate Components Noted and Details as Applicable:
Max. Design Pressure, from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping,
system: Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterf lashing, Coping, Etc.,
Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base
Type:Plywood Flashing,Component Material, Material'Thickness, Fastener
Type,Fastener Spacing or Submit Manufacturers Details that
Gauge Thickness: 5/8 Comply with RAS 111 and Chapter 16.
Slope: •5/15
Anchor/Base Sheet&No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material: FT.
Insulation Base Layer: N/A
Base Insultation Size and Thickness: N/A Parapet
Base Insulation Fastener/Bonding Material: Height
N/A
Top Insulation Layer: N/A
N/A
Top Insulation Size and Thickness: N/A SBS-SA Cap FT.
Top Insulation Fastener/Bonding Material: SBS-SA Base
N/A
Mean
Base Sheet(s) & No.of Ply(s):
sBS-SA Plywood Roof
Base Sheet Fastener/Bonding Material: Height
N/A
10,
Ply Sheet(s)'& No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply: SBS-SA
Top Ply Fastener/Bonding Material:
. LUCIE WORKS
Section D ( eep Slope Roof System)
Roof System Manu cturer:
Notice ofAcceptan Number:
Minimum Design Wind P ssures, If Applicable(From RAS 127 or Calculations):
Zone 1: Zone 2e: Zone 2n: Zone 2r: Zone 3e: Zone r:
D Type:
Ty - Underlayment:
Roof Slope:
12 Ins ation:
Fir Barrier: Z_
Ridge Ventilation? Fas ner Type &Sp cing:
Ad esive pe:
Ty Cap Sheet:
Mean Roof Height: I Roo vering:
Type Size Drip
Edge:
I LUCIE WORKS
Section E(Tile Calculations)
For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mf. If the Mf values
e greater than or equal to the Mrvalues,for each area of the roof,then the tile attachment metho eptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: x _ _�-Mg: =Mn Product Approval Mi
(Zone 2e: x? = )-Mg: =M'a Product Approval Mf
(Zone 2n: x _ _)- Mg: =Mom, Product Approval
(Zone 2r: x _ )-Mg: =M Product Approval f
one 3e: x _ -Mg: =Me,. Product Appro I Mf
( ne 3r: X _ -�-Mg: =Mrar Product Appr val Mf
Method 2"Simplified Tile Calculations Per Table Bel "
Required Moment of esistance(Mr) From Table Below Product Approval Mf
Mr required Moment Resistance*
Mean Roof Height Roof lope 15, 20' 25' 30' 40'
2:12 34.4 36.5 38.2 39.7 42.2
3:12 32.2 34.4 36.0 37.4 39.8
4:12 1130.4 32.2 33.8 35.1 37.3
5:12 28.4 30.1 31.6 32.8 34.9
6:12 .4 28.0 29 4 30.5 32.4
7:12 24. 25.9 .1 28.2 30.0
*Must be used in conjunction with a list o moment based tile sy ems
• For Uplift based tile systems use Method 3. Compare the valu s for F'with the values for Fr If the F'values are greater than or
equal to the Fr values,for each area of the ro then the tile ttachment method is acceptable.
Method 3" lift Base Tile Calculations Per RAS 12T
(Zone 1: x L =x W:= ) -W: cos =Fri Product Approval F'
(Zone 2e: x L =x W:= )-W: s r =Fr2e Product Approval F'
(Zone 2n: x L =x W:= )-W: c r =Fr2n Product Approval F'
(Zone 2r: x L =x W:= )-W: cos =Fr2r Product Approval F'
(Zone 3e: x L =x W:= )-W: Cos r =Frse Product Approval F'
(Zone 3r: x L =x W:= )-W: Cos r =Fr3r Product Approval F'
Where to Obtain Infor ation
Description Symbol Where to find
Design Pressure Zo/es 1,2e,2n,2r,3e,3r From app\by
e table in RAS 127 or by an engineering analysis
Design Pressure Zo es 1,2e,2n,2r,3e,3r
prepared based on ASCE 7
Mean Roof Height H Job Site
Roof Slope 0 Job Site
Aerodynamic Multiplier a Product Approval
Restoring Moment due to Gravi Mg Product Approval
Attachment Resistance Mf Product Approval
Required Moment Resista a Mg Calculated
Minimum Attachment sistance F' Product Approval
Required Uplift Resis nce Fr Calculated
Average Tile Weig W Product Approval
Tile Dimensions L=length W=width Product Approval
All calculatio must be submitted to the building official at the time of permit application.