Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFING11/30121, 12:01 PM Florida Building Code Online Business & Professional Regulation r vas Home Log in User Registration Hot Topics Submit Surcharge Stats & Facts Publications contact us 1305 Site Map Unks Search � Product Approval t+ bOr USER: Public User Procitict ARQrOyal Menu > Product or Application Search > Application List > Application Detail FL # FL27499-R4 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer 06 Dynamic Metals Address/Phone/Email 3201 SE Dominica Terace Stuart, FL 34997 (772)872-8030 juan@dynarnicmetal.net Authorized Signature Lara Jesus juan@dynamicmetal.net Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida license PE-62354 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/06/2026 Validated By Lucas A. Turner, P.E., MBA Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL27499 R4 C01 Dyo 01Qp { Standard Year TAS 100 1995 TAS 110 2000 TAS 125 2003 https:llwww.floridabuilding.orglpr/pr_app_dU.aspx?paramwGEVXQwtDquHOE2Ywe°/a2bOsCepABg3%2bkM6Ffy6ER6EZWMOZCvLCMMgag%3d%3d 115 11/30/21. 12:01 PM Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page 0 FL A 27499.1 Model, Number or Name DM Class 1000 1" Nallstrip 04/18/2021 04/30/2021 05/03/2021 06/08/2021 00 Page I / 2 0 0 Description 26 Ga. galvalume mated steel roof panel, 16" wide, with 1" snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 II 4991 Dwc,gdj Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 4991 Eval.odf Created by Independent Third Party: Yes 127499.2 1 DM Class 1000 1" Nallstrip, 1 .032" Aluminum roof panel, 16" wide, with 1" snap Flt seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 II 4992 Dwe,gdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 4992 Eval.odf Created by Independent Third Party: Yes 27499.3 DM Class 1050 1 1/2" Nallstrip s032' I eams. Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL27499 R4 It 4993 DWo,pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 4993 Eval.odf Created by Independent Third Party: Yes 27499.4 DM Class 1050 1 1/2" Nallstrip 24 Ga. Galvalume coated steel roof panel, 19" wide, with 1 1/2" snap fit seams Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 11 4994 Dwu,pd[ Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 4994 Eval.odf Created by Independent Third Party: Yes 27499.5 DM Class 1150 1" Mechanical Seam .032" Aluminum roof panel, 21" wide, with 1" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 RR4 11 4995 DwQJW Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval Report for Limits of Use. FL27499 R4 AE 4995 Eval.odf Created by Independent Third Party: Yes 27499.6 DM Class 1150 1" Mechanical Seam .032" Aluminum roof panel, 21" wide, with 1" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: No FL27499 R4 II 4996 Dwe,gd[ Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawings and Eval Report for FL27499 R4 AE 4996 Eval.odf Umits of Use. Created by Independent Third Party: Yes 27499.7 DM Class 1150 1" Mechanical Seam 26 Ga. Galvalume coated steel roof panel, 21" wide, with 1" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 It 4997 Dwo,= Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394 Mips//www.Floridabuilding.org/pr/pr_app_dtl.aspx7param=wGEVXOwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 2/5 11130/21, 12:01 PM Florida Building Code Online Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawings and Eval Report for FL27499 R4 AE 4997 Eval.odf Limits of Use. I Created by Independent Third Party: Yes 27499.8 DM Class 1500 1 1/2" Mechanical seams. Aluminum roof panel, 20" wide, with 1 1/2" standing Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. 27499.9 DM Class 1500 1 1/2" Mechanical Seam Installation Instructions FL27499 R4 II 4998 Dwg,pdj Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499 R4 AE 4998 Eval.odf Created by Independent Third Party: Yes 16 oz. Copper roof panel, 16" wide, with 1 1/2" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 11 4999 Dwa.odf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 4999 Eval.odf Created by Independent Third Party: Yes 27499.10 I SMmlaw 1500 1 1/2" Mechanical I s26 tand ng slealume coated steel roof panel, 16" wide, with 1 1/2" 1 DM Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 II 49910 Owa,gdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Umits of Use. FL27499 R4 AE 49910 Eval.odf Created by Independent Third Party: Yes 27499.11 DM Class 1500 1 1/2" Mechanical i 32""Aluminum roof panel, 16" wide, with 1 1/2" standing Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL27499 R4 II 49911 DWa,Rd( Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49911 Eval.odf Created by Independent Third Party: Yes 27499 12 DM Claw 1500 1 1/2" Mechanical standingseams. lvlume mated steel roof panel, 16" wide, with 1 1/2" Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 It 49912 Dwa,gdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49912 Eval.gd( Created by Independent Third Party: Yes 27499.13 I DM Class 1500 1 1/2" Mechanical s24 Ga. tanding slealume coated steel roof panel, 20" wide, with 1 1/2" Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL27499 R4 II 49913 Owa,Qd( Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49913 EvaL W Created by Independent Third Party: Yes 27499.14 DM Class 1750 1 3/4" Snaplock 2GSnaplock seams, coatedGalvalume eel toometal deck. panel, 18wide, with 1 4 Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL27499 R4 II 49914 Dwa,gdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPEft 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49914 Eval.W Created by Independent Third Party: Yes 27499.15 1 DM Class 1750 1 3/4" Snaplock .032" Aluminum roof panel, 18" wide, with 1 3/4" Snaplock seams, attached to metal deck. https:llw.floridabuilding.org/pr/pr_app_00.aspxTparam=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ERGEzwMOZCvLCMMgag%3d%3d 315 11/30/21. 12:01 PM Florida Building Code Online Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 11 49915 Dwgj& Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva[ report for Limits of Use. FL27499 R4 AE 49915 EvaI.Ddf Created by Independent Third Party: Yes 27499.16 DM Class 1750 1 3/4" Snaplock .032" aluminum roof panel, 18" wide, with 1 3/4" Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 I] 49916 Dw jW Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49916 Eval.odf Created by Independent Third Party: Yes 27499.17 DM Gass 1750 1 3/4" Snaplock 24 Ga. galvalume coated steel roof panel, 18" wide, with 1 3/4" Snaplock seams. Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL27499 R4 11 49917 dwq W Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49917 Eval.l= Created by Independent Third Party: Yes 27499.18 DM Class 2000 2" Mechanical Seam .032 Aluminum roof panel, 18" wide, with 2" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 11 49918 0wgjW Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Umits of Use. FL27499 R4 AE 49918 Eval.gdf Created by Independent Third Party: Yes 27499.19 DM Class 2000 2" Mechanical Seam 24 Ga. galvalume coated steel roof panel, 18" wide, with 2" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 11 49919 Dwgj& Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49919 Eval.gd[ Created by Independent Third Party: Yes 27499.20 DM Class 500 SV Crimp 26 Ga. galvalume Coated steel roof panel, 24" wide, with SV crimp. Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL27499 R4 1I 49920 DwD.gdj Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49920 Eval,l= Created by Independent Third Party: Yes Go to Page • 00 Page 1/200 Contact Bs :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employee Qpvdaht 2007-2013 State of Florida.:: Pnvaav Statement :: Arcessibllity Statement :: Refund Statement Under Florida law, email addresses are public records. If you do trot want your e-mall address released In response to a public -records request, do not send electronic mall to Mls entity. Instead, contact Me office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -pursuant to Section 455.275(1), Flonda Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide Me Department with an email address If they have one. The smalls provided may be used for official communication wIM Me licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide Me Department with an email address which can be made available ro the public. To determine IF you are a licensee under Chapter 455, F.S., please click la=. product Approval Accepts: M 9:1 507 tlsn e https://www.floridabuilding.org/prfpr_app_dll.aspx?param=wGEVXQwlDquHOE2Ywe/2bOsCepABg3°/2bkM6Ffy6ER6EzwMOZCvLCMMgag`/3d%3d 4/5 11130/21. 12:01 PM Florida Building Code Online Credit Card Safe https:/1www.0oridabuilding.org/prlpr_app_dtl.aspz?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3/2bkM6Ffy6ER6EzwMOZCvLCMMgag/3d°/n3d 515 WOLTERS ENGINEERING ENGINEERING, DRAFTING, CONSULTING 1521197th Road N West Palm Beach, FL 33412 PhIFx: (561) 225-1982 PRODUCT EVALUATION (FOR HVHZ APPROVED PRODUCT) PRODUCT: DM CLASS 1000 26 GA. GALVALUME 1" NAILSTRIP 16" WIDE ROOF PANEL (FLPA# 27499.1) MANUFACTURER: DYNAMIC METALS, LLC 3201 SE DOMINICA TERRACE STUART, FL 34997 To all concerned, The DM Class 1000 Series 26 Ga. Galvalume 1" Nailstrip 16" Wide Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the requirements of Sections 1507.4 and 1518.9 of the 7th Edition (2020) Florida Building Code. The panel has been tested per TAS 100, TAS 125, and ASTM E2140 by Intertek B&C with results shown in test reports G3443.40.450- 44, G3443.14-450-44, and M1607.01-450-44. It has also been tested per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing "NSS16-HZ" dated 8/16/19, signed and sealed by Scott Wolters, PE. 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE. 3. Supplemental Calculations to support NSS16-HZ, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 7th Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: 16" (nominal) Fastener Spacing across panel: 16" (at Nailstrip) (Panels overlap with male/female snap fit) Min. Slope: HVHZ: 1712" Non-HVHZ: '/2712' 5MCIALIZING IN IMPACf M515fANf CU?rA1NW&L5. 5f0ITFP0Nf5. & WINPOW5 Option #1 Installation Option #2 Installation Max. Design Pressure: -116 psf -176 psf Fastener Spacing: 3" From Ends, 6" Max. O.C. 3" From Ends, 6" Max. O.C. Min Panel Fasteners: #10x1" Panclip Fasteners #10x1" Panclip Fasteners Panel Sealant: Continuous bead of Geoce" 2300 or 2320 at Nailstrip side of seam at roof slopes <3"/12" only) Continuous bead of Geocel 2 0 or 2320 at Nailstrip side of am Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note #2 below) Note: Outside of the HVHZ in areas with windspeeds < 170 mph,1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type II, installed and anchored per FBC Section 1507.1.1.1 (min). (or) Any underlayment with a valid FLPA or Miami -Dade NOA Note: Outside of the HVHZ in areas with windspeeds < 170 mph, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Minimum Substrate: '/' (15/32" min) 4-ply COX Plywood or'/4" solid wood planks (S.G. _ .42 min) nailed to 2x rafters spaced 24" max. on center with 6d ring -shank nails spaced 6" on center. Note: The'/4" wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above, or as specified by a Florida licensed Architect/Engineer Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation, 5KCI&IZING IN IMPACT M515TANf CLVAINIWALI-5, 5f0IVk0Nr5, & WINPOW5 4. All panel system perimeters, penetrations, and transitions to be flashed and sealed per the requirements of RAS 133, 5. Rational analysis, provided by a Florida licensed ArchitecVEngineer per FAS 61 G20.3.005(e), may be used for project specific approval by the local authorities having jurisdiction. 6. Where required by the Florida Building Code, panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement, "Dynamic Metals FL #27499.1, DM Class 100E". Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per approval of 3b party QA provider, to the dimensions shown on Drawing NSS16-HZ: SSQ-6800617 SSQ-5150216 SSQ-6810617 SSQ-6690517 SSQ4560615 SSQ2-2310920 5VC-0490718 5VC-0360516 SSQ2-2320920 Re -Roofing: The DM Class 1000 Series 26 Ga. Galvalume 1" Nailstrip 16" Wide Roof Panel may be installed over a single layer of existing asphalt shingles, provide the existing roof meets the requirements of Section 1511 of the Florida Building Code. If you have any questions or need more information concerning this approval, please contact me. Thank you!,l//�, 5. J�'•0 kGoE6. '�^ 2354fJ2354olters FL PE# 62 APR15 Mco'.• STATE OF ; T� .-" ' S 5MCIALIZIN6 IN IMPACf M515fANf CWrANWPLL5, 5fGRFFR0Nf5, & WIN19OW5 In co T- aanssl sintad \�t{OL `yI S��� �/'jO y-vu4P@Ol0l:IIVW3 ssot-[vt ftW:Hd 'NM xn�-ccx uocl rull9ns lsl ; mom; ° ; p 3�' *t-[et I[[cl :)vi 15601 1i'l4Vn15 3'JuvW 3mN m. i031v15 :G: (roi[xui mi Iau3alawAw°u/y'.Mmro 33VUU31 VJINIW0035 SOEC S: : a = OInIQ3rmw suvror. "' .Sii�S�,,n �= S1d13 W JI Wb NAO J W Z mo__ VVV))) N 0 O Y W C X C QI � C N it I C� �rJ