HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET - � ,. ST. LUCIE WORKS
L' L G
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code-Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Required Sections of Attachments Required
Roof System the Permit Application See List Below
Form
Low Slope Application A, B,C 1,2,3,4,5,6,7
Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7
Asphaltic Shingles A, B, D 1,2,4,5,6,7
Concrete or Clay Tile A, B, D, F 1,2,3,4,5,6,7
etal Roafs A, B, D
Wood Shingles and A, B, D
Shakes
Other As Applicable 1,2,3,4,5,6,7
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4. Other Component of Product Approval
5. Municipal Permit Application
6. Owners Notification for Roofing Considerations(Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18,2021
ST. LUCIE WORKS
Section A (General Information)
Master Permit No. // Process No.
Contractors Name: `Du Yl License# (Lf- ►33234/b
Job Address
ROOF CATEGORY
❑Low Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles
❑Asphaltic Shingles B-getal Panel/Shingles Mood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ New roof ❑ Repair ❑ Maintenance ❑-<eroofing ❑Recovering
ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) 3 C) Total (SF) Di)
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets.
,
r
1
3 T
i
i
i
I \�
ST. LUCIE WORKS
Section E(Tile Calculations)
For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mr.If the Mr values
are greater than or equal to the Mrvalues,for each area of the roof,then the tile attachment method is acceptable.
Method 1'Moment Based rile Calculations Per RAS 12T
(Zones: _x2._= _�-Mg:_=M,1_ Product ApprovalM,
(Zone2e: _x)_= -Mg:_=MR._ Product Approval Mr
(Zone2n: _xb_- -Mg:_=Mm,_ Product Approval Mf,
(Zone2r: _xl_= -Mg:_=Mm_ Product ApprovalMf
(Zone3e: -x7_= _ I-M9:_=Mi - Product Approval Mf.
(Zone3r: _X7L_= _I-Mg:_=Mr9r- Product ApprovalMf
Method 2 "Sim li ied Tile Calcu do er Table Below"
Required Moment of Resistance(Mr) From Tab Below uct Approval Mr
Mr requ a ment Re istance*
Mean Roof Height Roof Slope 15' 20' 25' 30' 40'
2:12 34.4 36. 38.2 39.7 42.2
3:12 32.2 34.4 36.0 37.4 39.8
4:12 30. 32.2 33.8 35.1 37.3
5:12 28.4 30.1 3U 32.8 34.9
6:12 26.4 28.0 29.4 30.5 32.4
7:12 24.4 5.9 27.1 28.2 30.0
*Must be used in conjunction with a list of moment aced tile systems
• For Uplift based tile systems use M hod 3. Compare a values for F'with the values for Fr If the F'values are greater than or
equal to the Fr values,for each area of roof,then the 'le attachment method is acceptable.
Metho "Uplift Based a Calculations Per RAS 12T
(Zone 1: x L=x W:= )-W: cos r -Fri Product Approval F'
(Zone 2e: x L=x W:= )-W: cos r =Frze Product Approval F'
(Zone 2n: x L =x W:= )-W: c r =Fon_ Product Approval F'
(Zone 2r: x L= = cos =Fr2r_ Product Approval F'
(Zone 3e: x -W. os r =Fr3e_ Product Approval F'
(Zone 3r: x L x •_ )-W: cos r =Fr3r_ Product Approval F'
Where to Obtain Information
Description Symbol Where to find
Design Pressure Zones 1,2 , h,2r,3e,3r From applicable table in RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height H Job Site
Roof Slope B Job Site
Aerodynamic Multiplier a Product Approval
Restoring Moment due to Gravity Ms Product Approval
Attachment Resistance Mr Product Approval
Required Moment Resistance M, Calculated
Minimum Attachment Resistance F' Product Approval
Required Uplift Resistance Fr Calculated
Average Tile Weight W Product Approval
Tile Dimensions L=length W=width Product Approval
All calculations must be submitted to the building official at the time of permit application.
ST. LUCIE VORKS
Section C (Low Slope Roof) Surfacing:
Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
manufacturer Zone oc @ Lap,# Rows—®"oo
(If a component is not used, identify as"NA") Zone 1:_" oc @ Lap,#Rows—@"oo
System Manufacturer: Z " oc @ Lap,#Rows—®"oD
Z e 3:_ c @ Lap Rows—®"o0
Product Approval No.:
Nu r of Fastener er 'on Board:
Design Wind Pressures, From RAS 129Or Calcula ' ns: Zone '• Z e 1:—Zone 2:—Zone 3:_
Zone 1':_Zone 1: Zone 2:_Zone 3:_ Illustrat C Dnents Noted and Details as Applicable:
Max. Design Pressure, from the specific product approv Woodbloc ' Gutter, Edge Termination, Stripping,
system: Flashing, C tinuous Cleat, Cant Strip, Base Flashing,
Counte lashi Coping, Etc.,
Deck: dicate: Mean of Height, Parapet Height,Height of Base
Type: FI hing,Component Material,Material'Thickness,Fastener
Type,Fastener Spacing or Submit Manufacturers Details that
Gauge Thickness: Compl with RAS 111 and Chapter 16.,
Slope:
Anchor/Base Sheet&No.df Ply(s):
Anchor/Base Sheet Fastener Bonding Material: FT.
Insulation Base Layer:
Base Insultation Size and T"c ness: Parapet
Base Insulation Fastener/Bondi Material: Height
Top Insulation Layer:
Top Insulation Size and Thickness: FT.
Top Insulation Fastener/Bonding Material:
Mean
Base Sheet(s)&No,of Ply(s): Roof
Base Sheet Fastener/Bonding Material: Height
Ply Sheet(s)'&No.of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
ST. LUCIE INORKS
Section ❑ (Steep Slope Roof System)
--)�/
Roof System Manufacturer: ,��/na^I�`C �
Notice of Acceptance Number:
Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations):
Zone L-41 Zone 2e:-:-SLZone 2n: Zone 2r: - q I_Zone 3e: Zone 3r:
Deck Type: 5 1,6 j" &D A Lz-100 1
Type Underlayment: -Pez l and
Roof Slope:
. 12 Insulation:
Fire Barrier: Al��-
Ridge Ventilation? Fastener Type &Spacing: ="fP—
Adhesive Type: A1114
Type Cap Sheet: /%/,.
Mean Roof Height: 1 z ' Roof Covering:
Type&Size Drip
Edge: