Product Approval
USER: Public user
rod APPL2YAI Menu > Prq uct or Appli Se r > ARP lion &, t > APPllcation Detail
' FL *
FL10758-RB
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg. keel er@owenscornIng. com
Authorized Signature Greg Keeler
greg-keeler@owenscorning.com
Technical Representative Greg Keeler
Address/Phone/Email 2790 Columbus Road
Granville, OH 43023
(740)321-6345
g reg. keeler@0wenscorn Ing.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory R00fin9 Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 12/31/2024
Validated 6y Steven M. tlrich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL10758 R8 Cal OCR14003.4 2020 FBC Eygl Vents final .pd
Sections from the Code
1708.2
Product Approval Method Method 2 Option B
Date Submitted 08/10/2020
Date Validated 12/16/2020
Date Pending FHC Approval 09/18/2020
Date Approved 12117/2020
Summary Of Products,
PL i
Model, Number or Name
DBacriptlon
10758.1
VentSure 4-Foot Strip Heat and
Moisture Ridge Vents
Copolymer plastic low pmfile attic Mge vents for Installation In
shingle roof systems
Limits of V.
Installation Instructions
Approved for use in NVHZ: No
Approved for use outside NVHZ: Yes
M10758 RS It QCR14003.4 2020 FBCf
Verified By: Zachary R. Priest 74021
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to evaluation report
Created by Intlepentlent Third Parry: Yes
Evaluation Reports
ELL0750 R AE OCRI4003.4 2020 FEC Ev I Vents final pdf
-
Created by Independent Third Party: Yes
10758.2
VentSu:e Law Profile Slant Back Roof
Galvanizetl metal roof vent
Vent With Pderbr Louver
Limits of Use
Installation Instructions
Approved for use in NVHZ: No
Approved for use outside HVHZ: Yes
FL10758 98 IT OCK14003.4 1920 ESC Eyal Vents,f
Verified By: Zachary R. Priest 74021
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Refer to evaluation repent.
FL10758 R8 AE OCRI4003
Created by Independent Third Party: Yes
10759.3
Ven6um Rigid Roll Ridge Vent
Ridge Ventilation System
Limits of Use
Installathm Instructions
Approved for use in NVHZ: No
Verified By: Zachary R. Priest 74021
Approved for use outside NVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Parry: was
Design pressure: NJA
Evaluation Reports
Other: Refer to evaluation report.
Created by Independent Third! Party: Yes
Beek f4xt
frentd. U,::$601 Bel >.shares,FL IZViv sflSbea]-iP>6
The Sbb of Ronda an WEED employee Coov 300>10135feteMFl lS :: p,Nan edtt b ::first
Iey Intem ni melt. rtyou be-eny y-.or
raised under duped ass, rs, must pmaae t
the nreneK. roamer email addresses aR pun
ern be made awlkbk m the punter To tenons
pra4uat App,evelAaeds
MCWN E
Credit Card
Safe
No.
■ CREEK Ce tfcote ofAuthorization 152E Edinburgh
2gh Or
17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 7' EDITION (2020)
Manufacturer. OWENS CORNING ROOFING AND ASPHALT LLC Issued December 15, 2020
1 Owens Coming Parkway
Toledo, OH 43657
(800)438-7465
www.owenscoming.com
Quality Assurance: PRI Construction Materials Technologies (QUA9110)
SCOPE
Category:
Roofing
Subcategory:
Roofing Accessories that are an Integral Part of the Roofing System
Code Sections:
1708.2
Properties:
Root Ventilation
Emily
Report No.
Stands
year
Architectural Testing, Inc (TST1658)
01-08660.04
TAS 100(A)
Was
Architectural Tealing, Inc(TST1558)
01-38660oli
TAS 100(A)
1995
Architectural Testing, In. (TST1569)
01774.01-109.18
TAS 100(A)
1895
ASTM D 635
2014
ASTM D 1929
2016
ASTM D2843
2016
PRI Construction Materials Technologies (TST5878)
AVIG-005-02-01
ASTM D 635
2014
ASTM D 1929
2016
ASTM D 2843
2016
PRI Construction Materials Technologies (TST5878)
AVIG-006-02-01
ASTM G 155
2013
PRI OonsWcdon Materials Technologies(TST5878)
OCF-111-02-01
ASTM D635
2014
ASTM D 1929
2016
ASTM D2643
2016
PRI Construction Materials Technologies (T5T5878)
OCF-112-02-01
ASTM G 155
2013
PRI Construction Materials Technologies (TST5878)
OCF-116-02-01
TAS 10)(A)
1995
PRI Construction Materials Technologies (TST5878)
0CF-223-02-01
TAS 100(A)
1995
PRI Construction Materials Technologles (TST5878)
011I-007-02-01
TAS 100(A)
1995
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shell notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not erymes nor imply warranty, installation, recommended use, or other product attributes that are not
speci6cslly addressed herein.
CREEK
TECHNICAL SERVICES, LLC
OWENS CORNING
VentSure® Roof VenUlatlon
PRODUCT DESCRIPTION AND APPLICATION
VentSure 4-Foot Strip 1-1/4" x 14-7/8" x 48" low -profile attic ridge vent consisting of a two -layer nylon -
Heat and Moisture Ridge polyester composite. Available with or without a polyester fabric moisture bamer for
Vents: installation in shingle roof systems.
48"
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 3:12 to maAmum 16112
Installation Height: Maximum 60-ft
Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the
ridge for ventilation. The slot shall terminate approAnnately 6-inches from the rake
edges. Apply a'/ -Inch wide bead of ASTM D 4586 rcoffng cement along the entire
length of the outside edges of the vent to seal the vent to the field shingles, taking
care to not completely cover the weep slots in the vent. Center the vent over the
opening and fasten to the deck using the 11 ga. Zinch galvanized ring shank nails
(shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be
installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start of each
vent piece.
Prepare the adjacent vent section by applying the roofing cement along the edges,
snap together with fixed vent, and fasten b the deck in the same manner as the fist
section. Fasten the ridge shingles over the vent to the deck on the marked 'shingle
nail line" with two (2) minimum 11 ga. 21/24nch galvanized ring shank roofing nails
(shall comply with FBC Section 1506.5) provided with the vent or as directed by the
shingle manufacturers installation instructions.
Allowable Roof Coverings: Asphalt shingles
Technical Services, LLC of any product changes or quality assurance changes throughout the duretion for which this report Is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that ere not
specifically addressed herein.
®CREEK OWENS CORNING
TECHNICAL SERVICES, LLC Venti Roof Ventllation
VentSuree Low Profile 1 B" x 24" x 2-3/16" (32" x 23" Flange base) static off -ridge vent composed of ASTM
Slant Back Roof Vent A653 galvanized etas] (available with painted finish). Material shall conform with
with Extarlor Louver. FBC Section 1507A.3.
]W
r�Lr »
�1Cx T T'i•F. qCFt `T
Deck Type:
Roof deck shall be constructed of closely fitted sheathing for new or exisfing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope:
Minimum 3:12
Installation Height:
Maximum 33-ft
Attachment Method:
Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from
the ridge. Apply 1/4-inch thick by 3-inch wide bed of ASTM D 4586 roofing cement
around inner and outer flange. Place vent directly over the hole, ensuring the vent
sits flat on the roof. Fasten vent 4-inches o.c. and 1-inch from outside edge of flange
with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section
1506.5), ensuring "/.-inch penetration through wood deck (Minimum 18 nails per
vent).
Install baPoe In IA -Inch bad of ASTM D 4586 roofing cement and secure with
minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5)
spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through
wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement.
Allowable Roof Coverings:
Asphalt shingles
Technkal Services, LLC of any product changes or %safity assurance Changes throughout be duration for which this report IS land.
This evaluation report does not express nor imply warranty, Installation, recarnmended use, or other product a8dbutes that are not
specifically addressed herein
. CREEK OWENS CORNING
VentSure® Roof Ventllatlon
TECHNICAL SERVICES, LLC
VentSur® Rlgld Roll 5/8" x 11-1/4" x 20' attic ridge vent composed of high density polypropylene with a
Ridge Vent: spun -bond polypropylene fabric.
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shaft be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 2:12 to maximum 20:12
Installation Height: Maximum 60-ft
Attachment Method: Cut a 2-inch opening (14nch on each side of the ridge) centered in the deck at the
ridge for ventilation. The slot shall terminate approximately 12-mchas from the rake
edges. Apply a continuous bead of polyurethane adhesive sealant along the entire
length of the outside edges of the vent to seal the vent to the field shingles. Center
the vent over the opening and fasten the vent 24-inches o.c. to the deck using
minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5),
ensuring % inch penetration through wood deck.
Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line"
with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section
1506.5) or as directed by the shingle manufacturers installation instructions,
ensuring %,inch penetration through wood deck. Outside edges of the shingles shall
be sealed with flashing cement.
Allowable Roof Coverings: Asphalt shingles
1) This report is not for use in the HVHZ.
2) Fire Classification is outside the scope of this evaluation.
3) The roof deck and deck attachment shall be designed by others in accordance with the FBC.
4) Owens Corning vents shall be installed in strict compliance with this evaluation report and the
manufacturers published installation instructions. In the event of conflict the more restrictive Installation
shall be enforced.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion prior to installation.
6) Installation of the roof assembly is outside the scope of this evaluation.
7) Owens Coming vents are intended to provide passive ventilation for an enclosed attic in residential
construction applications,
8) All products listed in this report shall be manufactured under a quality, assurance program In compliance With
Rule 61 G20-3.
Technical Services, lLC of any product changes or qusllly assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK OWENS CORNING
Ventsure® Roo/Vandletlon
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7s' Edition (2020) as evidenced in the relerenoed documents submitted by the named manufacturer.
PAY'R' 2020.12.15
No 74021 '•• : fQ("-�o ��-13:59:34
STATE OF :�trr�
05'00'
.4 O R �0,: G\,� Zachary R. Priest, P.E.
'y�NAt-Epp Florida Registration No.74027
p,„• • •„ Organization No. ANE9841
OFINDEPENDENCE
CREEK Technical Serves, LLC does not have, nor will it acqulre, a financial Interest in any com army manulacturing or distributing
Products under this evaluation.
CREEK Technical Services, LLC is not owned, opendl or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor Wit acquire, a financial interest in any company manufacturing or distnbuting products
under this evaluation.
Zachary R. Priest, P.E. does out have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
Technical Services, LLC of any product changes or quality assurance changes throughout the dumtion for which this report is valid.
This evaluation report do" not express nor Imply warranty, installation, recommended use, or other product attributes that am not
specifically addressed herein.