Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING ACCSSESORIES"VABusiness .ry ' Professional Regulation 6CIS Home LogIn User Registration - H 9 ot7opfts Submit Surcharge SFa[s $Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public user rod APPL2YAI Menu > Prq uct or Appli Se r > ARP lion &, t > APPllcation Detail ' FL * FL10758-RB Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg. keel er@owenscornIng. com Authorized Signature Greg Keeler greg-keeler@owenscorning.com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740)321-6345 g reg. keeler@0wenscorn Ing.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory R00fin9 Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 12/31/2024 Validated 6y Steven M. tlrich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL10758 R8 Cal OCR14003.4 2020 FBC Eygl Vents final .pd Sections from the Code 1708.2 Product Approval Method Method 2 Option B Date Submitted 08/10/2020 Date Validated 12/16/2020 Date Pending FHC Approval 09/18/2020 Date Approved 12117/2020 Summary Of Products, PL i Model, Number or Name DBacriptlon 10758.1 VentSure 4-Foot Strip Heat and Moisture Ridge Vents Copolymer plastic low pmfile attic Mge vents for Installation In shingle roof systems Limits of V. Installation Instructions Approved for use in NVHZ: No Approved for use outside NVHZ: Yes M10758 RS It QCR14003.4 2020 FBCf Verified By: Zachary R. Priest 74021 Impact Resistant: N/A Design Pressure: N/A Other: Refer to evaluation report Created by Intlepentlent Third Parry: Yes Evaluation Reports ELL0750 R AE OCRI4003.4 2020 FEC Ev I Vents final pdf - Created by Independent Third Party: Yes 10758.2 VentSu:e Law Profile Slant Back Roof Galvanizetl metal roof vent Vent With Pderbr Louver Limits of Use Installation Instructions Approved for use in NVHZ: No Approved for use outside HVHZ: Yes FL10758 98 IT OCK14003.4 1920 ESC Eyal Vents,f Verified By: Zachary R. Priest 74021 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Refer to evaluation repent. FL10758 R8 AE OCRI4003 Created by Independent Third Party: Yes 10759.3 Ven6um Rigid Roll Ridge Vent Ridge Ventilation System Limits of Use Installathm Instructions Approved for use in NVHZ: No Verified By: Zachary R. Priest 74021 Approved for use outside NVHZ: Yes Impact Resistant: N/A Created by Independent Third Parry: was Design pressure: NJA Evaluation Reports Other: Refer to evaluation report. Created by Independent Third! Party: Yes Beek f4xt frentd. U,::$601 Bel >.shares,FL IZViv sflSbea]-iP>6 The Sbb of Ronda an WEED employee Coov 300>10135feteMFl lS :: p,Nan edtt b ::first Iey Intem ni melt. rtyou be-eny y-.or raised under duped ass, rs, must pmaae t the nreneK. roamer email addresses aR pun ern be made awlkbk m the punter To tenons pra4uat App,evelAaeds MCWN E Credit Card Safe No. ■ CREEK Ce tfcote ofAuthorization 152E Edinburgh 2gh Or 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7' EDITION (2020) Manufacturer. OWENS CORNING ROOFING AND ASPHALT LLC Issued December 15, 2020 1 Owens Coming Parkway Toledo, OH 43657 (800)438-7465 www.owenscoming.com Quality Assurance: PRI Construction Materials Technologies (QUA9110) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1708.2 Properties: Root Ventilation Emily Report No. Stands year Architectural Testing, Inc (TST1658) 01-08660.04 TAS 100(A) Was Architectural Tealing, Inc(TST1558) 01-38660oli TAS 100(A) 1995 Architectural Testing, In. (TST1569) 01774.01-109.18 TAS 100(A) 1895 ASTM D 635 2014 ASTM D 1929 2016 ASTM D2843 2016 PRI Construction Materials Technologies (TST5878) AVIG-005-02-01 ASTM D 635 2014 ASTM D 1929 2016 ASTM D 2843 2016 PRI Construction Materials Technologies (TST5878) AVIG-006-02-01 ASTM G 155 2013 PRI OonsWcdon Materials Technologies(TST5878) OCF-111-02-01 ASTM D635 2014 ASTM D 1929 2016 ASTM D2643 2016 PRI Construction Materials Technologies (T5T5878) OCF-112-02-01 ASTM G 155 2013 PRI Construction Materials Technologies (TST5878) OCF-116-02-01 TAS 10)(A) 1995 PRI Construction Materials Technologies (TST5878) 0CF-223-02-01 TAS 100(A) 1995 PRI Construction Materials Technologles (TST5878) 011I-007-02-01 TAS 100(A) 1995 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shell notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not erymes nor imply warranty, installation, recommended use, or other product attributes that are not speci6cslly addressed herein. CREEK TECHNICAL SERVICES, LLC OWENS CORNING VentSure® Roof VenUlatlon PRODUCT DESCRIPTION AND APPLICATION VentSure 4-Foot Strip 1-1/4" x 14-7/8" x 48" low -profile attic ridge vent consisting of a two -layer nylon - Heat and Moisture Ridge polyester composite. Available with or without a polyester fabric moisture bamer for Vents: installation in shingle roof systems. 48" Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 3:12 to maAmum 16112 Installation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approAnnately 6-inches from the rake edges. Apply a'/ -Inch wide bead of ASTM D 4586 rcoffng cement along the entire length of the outside edges of the vent to seal the vent to the field shingles, taking care to not completely cover the weep slots in the vent. Center the vent over the opening and fasten to the deck using the 11 ga. Zinch galvanized ring shank nails (shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start of each vent piece. Prepare the adjacent vent section by applying the roofing cement along the edges, snap together with fixed vent, and fasten b the deck in the same manner as the fist section. Fasten the ridge shingles over the vent to the deck on the marked 'shingle nail line" with two (2) minimum 11 ga. 21/24nch galvanized ring shank roofing nails (shall comply with FBC Section 1506.5) provided with the vent or as directed by the shingle manufacturers installation instructions. Allowable Roof Coverings: Asphalt shingles Technical Services, LLC of any product changes or quality assurance changes throughout the duretion for which this report Is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that ere not specifically addressed herein. ®CREEK OWENS CORNING TECHNICAL SERVICES, LLC Venti Roof Ventllation VentSuree Low Profile 1 B" x 24" x 2-3/16" (32" x 23" Flange base) static off -ridge vent composed of ASTM Slant Back Roof Vent A653 galvanized etas] (available with painted finish). Material shall conform with with Extarlor Louver. FBC Section 1507A.3. ]W r�Lr » �1Cx T T'i•F. qCFt `T Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or exisfing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 3:12 Installation Height: Maximum 33-ft Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from the ridge. Apply 1/4-inch thick by 3-inch wide bed of ASTM D 4586 roofing cement around inner and outer flange. Place vent directly over the hole, ensuring the vent sits flat on the roof. Fasten vent 4-inches o.c. and 1-inch from outside edge of flange with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring "/.-inch penetration through wood deck (Minimum 18 nails per vent). Install baPoe In IA -Inch bad of ASTM D 4586 roofing cement and secure with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement. Allowable Roof Coverings: Asphalt shingles Technkal Services, LLC of any product changes or %safity assurance Changes throughout be duration for which this report IS land. This evaluation report does not express nor imply warranty, Installation, recarnmended use, or other product a8dbutes that are not specifically addressed herein . CREEK OWENS CORNING VentSure® Roof Ventllatlon TECHNICAL SERVICES, LLC VentSur® Rlgld Roll 5/8" x 11-1/4" x 20' attic ridge vent composed of high density polypropylene with a Ridge Vent: spun -bond polypropylene fabric. Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shaft be designed and installed in accordance with FBC requirements. Roof slope: Minimum 2:12 to maximum 20:12 Installation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (14nch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 12-mchas from the rake edges. Apply a continuous bead of polyurethane adhesive sealant along the entire length of the outside edges of the vent to seal the vent to the field shingles. Center the vent over the opening and fasten the vent 24-inches o.c. to the deck using minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring % inch penetration through wood deck. Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) or as directed by the shingle manufacturers installation instructions, ensuring %,inch penetration through wood deck. Outside edges of the shingles shall be sealed with flashing cement. Allowable Roof Coverings: Asphalt shingles 1) This report is not for use in the HVHZ. 2) Fire Classification is outside the scope of this evaluation. 3) The roof deck and deck attachment shall be designed by others in accordance with the FBC. 4) Owens Corning vents shall be installed in strict compliance with this evaluation report and the manufacturers published installation instructions. In the event of conflict the more restrictive Installation shall be enforced. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 6) Installation of the roof assembly is outside the scope of this evaluation. 7) Owens Coming vents are intended to provide passive ventilation for an enclosed attic in residential construction applications, 8) All products listed in this report shall be manufactured under a quality, assurance program In compliance With Rule 61 G20-3. Technical Services, lLC of any product changes or qusllly assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK OWENS CORNING Ventsure® Roo/Vandletlon TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7s' Edition (2020) as evidenced in the relerenoed documents submitted by the named manufacturer. PAY'R' 2020.12.15 No 74021 '•• : fQ("-�o ��-13:59:34 STATE OF :�trr� 05'00' .4 O R �0,: G\,� Zachary R. Priest, P.E. 'y�NAt-Epp Florida Registration No.74027 p,„• • •„ Organization No. ANE9841 OFINDEPENDENCE CREEK Technical Serves, LLC does not have, nor will it acqulre, a financial Interest in any com army manulacturing or distributing Products under this evaluation. CREEK Technical Services, LLC is not owned, opendl or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor Wit acquire, a financial interest in any company manufacturing or distnbuting products under this evaluation. Zachary R. Priest, P.E. does out have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT Technical Services, LLC of any product changes or quality assurance changes throughout the dumtion for which this report is valid. This evaluation report do" not express nor Imply warranty, installation, recommended use, or other product attributes that am not specifically addressed herein.