Loading...
HomeMy WebLinkAboutbirch energy calcs FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BIRCH DRIVE PROJECT Builder Name: SOUTHEN CITY DEVELOPMENT Street: 5109 BIRCH DRIVE Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL,34982 Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Types(1721.3 sgft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1545.30 ft2 b.Frame-Wood,Adjacent R=13.0 176.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 11.Ceiling Types (1866.0 sgft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1866.00 ft2 6. Conditioned floor area above grade(ft2) 1866 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 7. Windows(201.6 sqft.) Description Area 12.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:LAUNDRY 6 150 a. U-Factor: Sgl,U=0.65 201.60 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 35.6 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 14.Heating systems kBtu/hr Efficiency ft Area Weighted Average Overhang Depth: 1.500 . Area Weighted Average SHGC: 0.250 a.Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15.Hot water systems SHGC(AVG): N/A a.Electric Cap:50 gallons 9. Floor Types (1866.0 sgft.) Insulation Area EF:0.980 a.Slab-On-Grade Edge Insulation R=0.0 1866.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 16.Credits None Glass/Floor Area: 0.108 Total Proposed Modified Loads: 53.36 PASS Total Baseline Loads: 60.25 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this fiV Code. calculation indicates compliance G'0D with the Florida Energy Code. PREPARED BY: NICOLE &L i"XWELL Before construction is completed DATE: 9-22-2021 this building will be inspected for ��RE Srq� compliance with Section 553.908 1 hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). 9/21/2021 4:08 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: BIRCH DRIVE PROJECT Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1866 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: SOUTHEN CITY DEVELOPM Rotate Angle: 0 Street: 5109 BIRCH DRIVE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City,State,Zip: FORT PIERCE, Family Type: Detached FL, 34982 New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1866 16181.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 227 2111.1 No 0 1 1 Yes Yes Yes 2 M BATH 117 936 No 0 1 Yes Yes Yes 3 M W IC 1 36 288 No 0 1 No Yes Yes 4 M W IC 2 42 336 No 0 1 No Yes Yes 5 KITCHEN 247 2297.1 Yes 0 1 Yes Yes Yes 6 LAUNDRY 96 768 No 0 1 Yes Yes Yes 7 FOYER 204 1897.2 No 0 1 Yes Yes Yes 8 GREAT RM 286 2659.8 No 0 1 Yes Yes Yes 9 BEDROOM 4 151 1208 No 0 1 1 Yes Yes Yes 10 CLST 4 18 144 No 0 1 Yes Yes Yes 11 BEROOM 3 164 1312 No 0 1 1 Yes Yes Yes 12 CLST 3 18 144 No 0 1 Yes Yes Yes 13 BATH 2 54 432 No 0 1 Yes Yes Yes 14 CLST 2 18 144 No 0 1 Yes Yes Yes 15 BEDROOM 2 156 1248 No 0 1 1 Yes Yes Yes 16 HALL 32 256 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation MASTER BEDRO 31 ft 0 227 ft2 ___- 1 0 0 2 Slab-On-Grade Edge Insulation M BATH 13 ft 0 117 ft2 ___- 1 0 0 9/21/2021 4:08 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 3 Slab-On-Grade Edge Insulation M W IC 1 1 ft 0 36 ft2 ____ 1 0 0 4 Slab-On-Grade Edge Insulation M W IC 2 1 ft 0 42 ft2 ____ 1 0 0 5 Slab-On-Grade Edge Insulation KITCHEN 13 ft 0 247 ft2 ___- 1 0 0 6 Slab-On-Grade Edge Insulation LAUNDRY 2 ft 0 96 ft2 ___- 1 0 0 7 Slab-On-Grade Edge Insulation FOYER 17 ft 0 204 ft2 ___- 1 0 0 8 Slab-On-Grade Edge Insulation GREAT RM 18 ft 0 286 ft2 ____ 1 0 0 9 Slab-On-Grade Edge Insulation BEDROOM 4 33 ft 0 151 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation CLST 4 2 ft 0 18 ft2 ____ 1 0 0 11SIab-On-Grade Edge Insulation BEROOM 3 12 ft 0 164 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation CLST 3 2 ft 0 18 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation BATH 2 6 ft 0 54 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation CLST 2 2 ft 0 18 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulation BEDROOM 2 29 ft 0 156 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation HALL 1 ft 0 32 ft2 ____ 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2086 ft2 0 ft2 Medium N 0.3 No 0.9 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1866 ft2 N N 9/21/2021 4:08 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 30 Blown 227 ft2 0.1 Wood 2 Under Attic(Vented) M BATH 30 Blown 117 ft2 0.1 Wood 3 Under Attic(Vented) M W IC 1 30 Blown 36 ft2 0.1 Wood 4 Under Attic(Vented) M W IC 2 30 Blown 42 ft2 0.1 Wood 5 Under Attic(Vented) KITCHEN 30 Blown 247 ft2 0.1 Wood 6 Under Attic(Vented) LAUNDRY 30 Blown 96 ft2 0.1 Wood 7 Under Attic(Vented) FOYER 30 Blown 204 ft2 0.1 Wood 8 Under Attic(Vented) GREAT RM 30 Blown 286 ft2 0.1 Wood 9 Under Attic(Vented) BEDROOM 4 30 Blown 151 ft2 0.1 Wood 10 Under Attic(Vented) CLST 4 30 Blown 18 ft2 0.1 Wood 11 Under Attic(Vented) BEROOM 3 30 Blown 164 ft2 0.1 Wood 12 Under Attic(Vented) CLST 3 30 Blown 18 ft2 0.1 Wood 13 Under Attic(Vented) BATH 2 30 Blown 54 ft2 0.1 Wood 14 Under Attic(Vented) CLST 2 30 Blown 18 ft2 0.1 Wood 15 Under Attic(Vented) BEDROOM 2 30 Blown 156 ft2 0.1 Wood 16 Under Attic(Vented) HALL 30 Blown 32 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belowo 1 E Exterior Concrete Block-Int InsuMASTER BE 4.1 17 0 9 4 158.7 ft2 0 0 0.3 0 2 S Exterior Concrete Block-Int InsuMASTER BE 4.1 14 0 9 4 130.7 ft2 0 0 0.3 0 3 E Exterior Concrete Block-Int Insul M BATH 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 4 N Garage Frame-Wood M BATH 13 9 0 8 0 72.0 ft2 0 0.1 0.3 0 5 N Garage Frame-Wood M W IC 2 13 6 0 8 0 48.0 ft2 0 0.1 0.3 0 6 W Garage Frame-Wood M W IC 2 13 1 0 8 0 8.0 ft2 0 0.1 0.3 0 7 S Exterior Concrete Block-Int Insul KITCHEN 4.1 13 0 9 4 121.3 ft2 0 0 0.3 0 8 N Exterior Concrete Block-Int Insul LAUNDRY 4.1 2 0 8 0 16.0 ft2 0 0 0.3 0 9 N Garage Frame-Wood LAUNDRY 13 6 0 8 0 48.0 ft2 0 0.1 0.3 0 10 N Exterior Concrete Block-Int Insul FOYER 4.1 17 0 9 4 158.7 ft2 0 0 0.3 0 11 E Exterior Concrete Block-Int InsuIGREAT RM 4.1 5 0 9 4 46.7 ft2 0 0 0.3 0 12 S Exterior Concrete Block-Int InsuIGREAT RM 4.1 13 0 9 4 121.3 ft2 0 0 0.3 0 13 E Exterior Concrete Block-Int InsuBEDROOM 4 4.1 9 0 8 0 72.0 ft2 0 0 0.3 0 14 S Exterior Concrete Block-Int InsuBEDROOM 4 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 15 W Exterior Concrete Block-Int InsuBEDROOM 4 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 16 W Exterior Concrete Block-Int Insul CLST 4 4.1 2 0 8 0 16.0 ft2 0 0 0.3 0 17 W Exterior Concrete Block-Int InsulBEROOM 3 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 18 W Exterior Concrete Block-Int Insul CLST 3 4.1 2 0 8 0 16.0 ft2 0 0 0.3 0 19 W Exterior Concrete Block-Int Insul BATH 2 4.1 6 0 8 0 48.0 ft2 0 0 0.3 0 20 W Exterior Concrete Block-Int Insul CLST 2 4.1 2 0 8 0 16.0 ft2 0 0 0.3 0 21 N Exterior Concrete Block-Int InsuBEDROOM 2 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 22 E Exterior Concrete Block-Int InsuBEDROOM 2 4.1 4 0 8 0 32.0 ft2 0 0 0.3 0 23 W Exterior Concrete Block-Int InsuBEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 9/21/2021 4:08 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated FOYER None .23 3 8 24 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 2 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 1 ft 6 in 1 ft 4 in None None 2 E 3 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 6 in 1 ft 4 in None None 3 S 7 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 6 in 1 ft 4 in None None 4 N 10 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 1 ft 6 in 1 ft 4 in None None 5 S 12 Metal Low-E Single Yes 0.65 0.25 N 53.6 ft2 1 ft 6 in 1 ft 4 in None None 6 S 14 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 6 in 1 ft 4 in None None 7 W 17 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 6 in 1 ft 4 in None None 8 W 19 Metal Low-E Single Yes 0.65 0.25 N 9.0 ft2 1 ft 6 in 1 ft 4 in None None 9 N 21 Metal Low-E Single Yes 0.65 0.25 N 25.0 ft2 1 ft 6 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 441 ft2 441 ft2 22 ft 8 ft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000275 1348.4 73.98 138.89 .0932 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 35.6 kBtu/hr 1068 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 60.9 gal 120 deg None 9/21/2021 4:08 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 150 ftz Attic 15 ftz Default Leakage LAUNDRY (Default)c(Default)c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb Mar Apr May rj Jun rj Jul rj Aug �Xj Se Oct Nov Dec Heatin HJan HFeb Mar Apr May Jun Jul Au Sep Oct Nov Dec Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftz Oft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ftz ft 0.3 M BATH Default(8 Ibs/sq.ft. ftz ft 0.3 M W IC 1 Default(8 Ibs/sq.ft. ftz ft 0.3 M W IC 2 Default(8 Ibs/sq.ft. ftz ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ftz ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ftz ft 0.3 FOYER Default(8 Ibs/sq.ft. ftz ft 0.3 GREAT RM Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 4 Default(8 Ibs/sq.ft. ftz ft 0.3 BEROOM 3 Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ftz ft 0.3 HALL 9/21/2021 4:08 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 6 of 6 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: BIRCH DRIVE PROJECT Builder Name: SOUTHEN CITY DEVELOPMENT Street: 5109 BIRCH DRIVE Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL,34982 Permit Number: Y U Owner: Jurisdiction: ST LUCIE COUNTY w Design Location: FL,Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation,insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or ceiling Concealed When required to be sealed,concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer.Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Nates and walls or ceilin s. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 9/21/2021 4:09 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 89 The lower the EnergyPerformance Index, the more efficient the home. 5109 BIRCH DRIVE, FORT PIERCE, FL, 34982 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1545.30 ft2 b.Frame-Wood,Adjacent R=13.0 176.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 11.Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1866.00 ft2 6. Conditioned floor area(ft2) 1866 b.N/A R= ft2 7. Windows- Description Area c.N/A R= ft2 a. U-Factor: Sgl,U=0.65 201.60 ft2 12.Ducts,location&insulation level R ft2 a.Sup:Attic,Ret:Attic,AH:LAUNDRY 6 150 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 SHGC: 13.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 35.6 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14.Heating systems kBtu/hr Efficiency SHGC: a.Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 0.250 8. Skylights Description Area 15.Hot water systems a.Electric Cap:50 gallons a. U-Factor(AVG): N/A ft2 EF:0.98 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1866.00 ft2 Credits(Performance method) None b.N/A R= ft2 c.N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building * ° Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed CAD WE based on installed Code compliant features. Builder Signature: Date: g O�-v"E STA Address of New Home: City/FL Zip: ' *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/21/2021 4:08 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1