HomeMy WebLinkAboutbirch energy calcs FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: BIRCH DRIVE PROJECT Builder Name: SOUTHEN CITY DEVELOPMENT
Street: 5109 BIRCH DRIVE Permit Office: ST LUCIE COUNTY
City,State,Zip: FORT PIERCE,FL,34982 Permit Number:
Owner: Jurisdiction: ST LUCIE COUNTY
Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 10. Wall Types(1721.3 sgft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1545.30 ft2
b.Frame-Wood,Adjacent R=13.0 176.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
11.Ceiling Types (1866.0 sgft.) Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1866.00 ft2
6. Conditioned floor area above grade(ft2) 1866 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
7. Windows(201.6 sqft.) Description Area 12.Ducts R ft2
a.Sup:Attic,Ret:Attic,AH:LAUNDRY 6 150
a. U-Factor: Sgl,U=0.65 201.60 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2 13.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 35.6 SEER:16.00
c. U-Factor: N/A ft2
SHGC: 14.Heating systems kBtu/hr Efficiency
ft Area Weighted Average Overhang Depth: 1.500 .
Area Weighted Average SHGC: 0.250 a.Electric Strip Heat 27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2 15.Hot water systems
SHGC(AVG): N/A a.Electric Cap:50 gallons
9. Floor Types (1866.0 sgft.) Insulation Area EF:0.980
a.Slab-On-Grade Edge Insulation R=0.0 1866.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 16.Credits None
Glass/Floor Area: 0.108 Total Proposed Modified Loads: 53.36 PASS
Total Baseline Loads: 60.25
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this fiV
Code. calculation indicates compliance G'0D
with the Florida Energy Code.
PREPARED BY: NICOLE &L i"XWELL Before construction is completed
DATE: 9-22-2021 this building will be inspected for ��RE Srq�
compliance with Section 553.908
1 hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2).
9/21/2021 4:08 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: BIRCH DRIVE PROJECT Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1866 Lot#
Owner Name: Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: SOUTHEN CITY DEVELOPM Rotate Angle: 0 Street: 5109 BIRCH DRIVE
Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie
Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City,State,Zip: FORT PIERCE,
Family Type: Detached FL, 34982
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 1866 16181.2
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 MASTER BEDROO 227 2111.1 No 0 1 1 Yes Yes Yes
2 M BATH 117 936 No 0 1 Yes Yes Yes
3 M W IC 1 36 288 No 0 1 No Yes Yes
4 M W IC 2 42 336 No 0 1 No Yes Yes
5 KITCHEN 247 2297.1 Yes 0 1 Yes Yes Yes
6 LAUNDRY 96 768 No 0 1 Yes Yes Yes
7 FOYER 204 1897.2 No 0 1 Yes Yes Yes
8 GREAT RM 286 2659.8 No 0 1 Yes Yes Yes
9 BEDROOM 4 151 1208 No 0 1 1 Yes Yes Yes
10 CLST 4 18 144 No 0 1 Yes Yes Yes
11 BEROOM 3 164 1312 No 0 1 1 Yes Yes Yes
12 CLST 3 18 144 No 0 1 Yes Yes Yes
13 BATH 2 54 432 No 0 1 Yes Yes Yes
14 CLST 2 18 144 No 0 1 Yes Yes Yes
15 BEDROOM 2 156 1248 No 0 1 1 Yes Yes Yes
16 HALL 32 256 No 0 1 No Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulation MASTER BEDRO 31 ft 0 227 ft2 ___- 1 0 0
2 Slab-On-Grade Edge Insulation M BATH 13 ft 0 117 ft2 ___- 1 0 0
9/21/2021 4:08 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
3 Slab-On-Grade Edge Insulation M W IC 1 1 ft 0 36 ft2 ____ 1 0 0
4 Slab-On-Grade Edge Insulation M W IC 2 1 ft 0 42 ft2 ____ 1 0 0
5 Slab-On-Grade Edge Insulation KITCHEN 13 ft 0 247 ft2 ___- 1 0 0
6 Slab-On-Grade Edge Insulation LAUNDRY 2 ft 0 96 ft2 ___- 1 0 0
7 Slab-On-Grade Edge Insulation FOYER 17 ft 0 204 ft2 ___- 1 0 0
8 Slab-On-Grade Edge Insulation GREAT RM 18 ft 0 286 ft2 ____ 1 0 0
9 Slab-On-Grade Edge Insulation BEDROOM 4 33 ft 0 151 ft2 ____ 1 0 0
10SIab-On-Grade Edge Insulation CLST 4 2 ft 0 18 ft2 ____ 1 0 0
11SIab-On-Grade Edge Insulation BEROOM 3 12 ft 0 164 ft2 ____ 1 0 0
12SIab-On-Grade Edge Insulation CLST 3 2 ft 0 18 ft2 ____ 1 0 0
13SIab-On-Grade Edge Insulation BATH 2 6 ft 0 54 ft2 ____ 1 0 0
14SIab-On-Grade Edge Insulation CLST 2 2 ft 0 18 ft2 ____ 1 0 0
15SIab-On-Grade Edge Insulation BEDROOM 2 29 ft 0 156 ft2 ____ 1 0 0
16SIab-On-Grade Edge Insulation HALL 1 ft 0 32 ft2 ____ 1 0 0
ROOF
Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2086 ft2 0 ft2 Medium N 0.3 No 0.9 No 0 26.57
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1866 ft2 N N
9/21/2021 4:08 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) MASTER BEDRO 30 Blown 227 ft2 0.1 Wood
2 Under Attic(Vented) M BATH 30 Blown 117 ft2 0.1 Wood
3 Under Attic(Vented) M W IC 1 30 Blown 36 ft2 0.1 Wood
4 Under Attic(Vented) M W IC 2 30 Blown 42 ft2 0.1 Wood
5 Under Attic(Vented) KITCHEN 30 Blown 247 ft2 0.1 Wood
6 Under Attic(Vented) LAUNDRY 30 Blown 96 ft2 0.1 Wood
7 Under Attic(Vented) FOYER 30 Blown 204 ft2 0.1 Wood
8 Under Attic(Vented) GREAT RM 30 Blown 286 ft2 0.1 Wood
9 Under Attic(Vented) BEDROOM 4 30 Blown 151 ft2 0.1 Wood
10 Under Attic(Vented) CLST 4 30 Blown 18 ft2 0.1 Wood
11 Under Attic(Vented) BEROOM 3 30 Blown 164 ft2 0.1 Wood
12 Under Attic(Vented) CLST 3 30 Blown 18 ft2 0.1 Wood
13 Under Attic(Vented) BATH 2 30 Blown 54 ft2 0.1 Wood
14 Under Attic(Vented) CLST 2 30 Blown 18 ft2 0.1 Wood
15 Under Attic(Vented) BEDROOM 2 30 Blown 156 ft2 0.1 Wood
16 Under Attic(Vented) HALL 30 Blown 32 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Belowo
1 E Exterior Concrete Block-Int InsuMASTER BE 4.1 17 0 9 4 158.7 ft2 0 0 0.3 0
2 S Exterior Concrete Block-Int InsuMASTER BE 4.1 14 0 9 4 130.7 ft2 0 0 0.3 0
3 E Exterior Concrete Block-Int Insul M BATH 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0
4 N Garage Frame-Wood M BATH 13 9 0 8 0 72.0 ft2 0 0.1 0.3 0
5 N Garage Frame-Wood M W IC 2 13 6 0 8 0 48.0 ft2 0 0.1 0.3 0
6 W Garage Frame-Wood M W IC 2 13 1 0 8 0 8.0 ft2 0 0.1 0.3 0
7 S Exterior Concrete Block-Int Insul KITCHEN 4.1 13 0 9 4 121.3 ft2 0 0 0.3 0
8 N Exterior Concrete Block-Int Insul LAUNDRY 4.1 2 0 8 0 16.0 ft2 0 0 0.3 0
9 N Garage Frame-Wood LAUNDRY 13 6 0 8 0 48.0 ft2 0 0.1 0.3 0
10 N Exterior Concrete Block-Int Insul FOYER 4.1 17 0 9 4 158.7 ft2 0 0 0.3 0
11 E Exterior Concrete Block-Int InsuIGREAT RM 4.1 5 0 9 4 46.7 ft2 0 0 0.3 0
12 S Exterior Concrete Block-Int InsuIGREAT RM 4.1 13 0 9 4 121.3 ft2 0 0 0.3 0
13 E Exterior Concrete Block-Int InsuBEDROOM 4 4.1 9 0 8 0 72.0 ft2 0 0 0.3 0
14 S Exterior Concrete Block-Int InsuBEDROOM 4 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0
15 W Exterior Concrete Block-Int InsuBEDROOM 4 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0
16 W Exterior Concrete Block-Int Insul CLST 4 4.1 2 0 8 0 16.0 ft2 0 0 0.3 0
17 W Exterior Concrete Block-Int InsulBEROOM 3 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0
18 W Exterior Concrete Block-Int Insul CLST 3 4.1 2 0 8 0 16.0 ft2 0 0 0.3 0
19 W Exterior Concrete Block-Int Insul BATH 2 4.1 6 0 8 0 48.0 ft2 0 0 0.3 0
20 W Exterior Concrete Block-Int Insul CLST 2 4.1 2 0 8 0 16.0 ft2 0 0 0.3 0
21 N Exterior Concrete Block-Int InsuBEDROOM 2 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0
22 E Exterior Concrete Block-Int InsuBEDROOM 2 4.1 4 0 8 0 32.0 ft2 0 0 0.3 0
23 W Exterior Concrete Block-Int InsuBEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0
9/21/2021 4:08 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N Insulated FOYER None .23 3 8 24 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 S 2 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 1 ft 6 in 1 ft 4 in None None
2 E 3 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 6 in 1 ft 4 in None None
3 S 7 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 6 in 1 ft 4 in None None
4 N 10 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 1 ft 6 in 1 ft 4 in None None
5 S 12 Metal Low-E Single Yes 0.65 0.25 N 53.6 ft2 1 ft 6 in 1 ft 4 in None None
6 S 14 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 6 in 1 ft 4 in None None
7 W 17 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 6 in 1 ft 4 in None None
8 W 19 Metal Low-E Single Yes 0.65 0.25 N 9.0 ft2 1 ft 6 in 1 ft 4 in None None
9 N 21 Metal Low-E Single Yes 0.65 0.25 N 25.0 ft2 1 ft 6 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 441 ft2 441 ft2 22 ft 8 ft 13
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000275 1348.4 73.98 138.89 .0932 5
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Single SEER: 16 35.6 kBtu/hr 1068 cfm 0.8 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.98 50 gal 60.9 gal 120 deg None
9/21/2021 4:08 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1 Attic 6 150 ftz Attic 15 ftz Default Leakage LAUNDRY (Default)c(Default)c 1 1
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
CoolingJan Feb Mar Apr May rj Jun rj Jul rj Aug �Xj Se Oct Nov Dec
Heatin HJan HFeb Mar Apr May Jun Jul Au Sep Oct Nov Dec
Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct X Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(W D) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
Heating(W D) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ftz Oft 0.3 MASTER BEDROO
Default(8 Ibs/sq.ft. ftz ft 0.3 M BATH
Default(8 Ibs/sq.ft. ftz ft 0.3 M W IC 1
Default(8 Ibs/sq.ft. ftz ft 0.3 M W IC 2
Default(8 Ibs/sq.ft. ftz ft 0.3 KITCHEN
Default(8 Ibs/sq.ft. ftz ft 0.3 LAUNDRY
Default(8 Ibs/sq.ft. ftz ft 0.3 FOYER
Default(8 Ibs/sq.ft. ftz ft 0.3 GREAT RM
Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 4
Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 4
Default(8 Ibs/sq.ft. ftz ft 0.3 BEROOM 3
Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 3
Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 2
Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 2
Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 2
Default(8 Ibs/sq.ft. ftz ft 0.3 HALL
9/21/2021 4:08 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 6 of 6
2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
a
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: BIRCH DRIVE PROJECT Builder Name: SOUTHEN CITY DEVELOPMENT
Street: 5109 BIRCH DRIVE Permit Office: ST LUCIE COUNTY
City,State,Zip: FORT PIERCE,FL,34982 Permit Number: Y
U
Owner: Jurisdiction: ST LUCIE COUNTY w
Design Location: FL,Fort Pierce U
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit
Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a
Knee walls shall be sealed. material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows,skylights The space between window/door jambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to
(including maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation shall
and cantilevered floors) be permitted to be in contact with the top side of
sheathing,or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation,insulation
Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls.
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building
be sealed to the finished surface. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be
on exterior wall tubs shall separate them from the showers and tubs. insulated.
Electrical/phone box on The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub-floor,wall covering or ceiling
Concealed When required to be sealed,concealed fire sprinklers shall only be sealed
sprinklers in a manner that is recommended by the manufacturer.Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover Nates and walls or ceilin s.
a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400.
9/21/2021 4:09 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 89
The lower the EnergyPerformance Index, the more efficient the home.
5109 BIRCH DRIVE, FORT PIERCE, FL, 34982
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1545.30 ft2
b.Frame-Wood,Adjacent R=13.0 176.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
11.Ceiling Type and insulation level Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1866.00 ft2
6. Conditioned floor area(ft2) 1866 b.N/A R= ft2
7. Windows- Description Area c.N/A R= ft2
a. U-Factor: Sgl,U=0.65 201.60 ft2 12.Ducts,location&insulation level R ft2
a.Sup:Attic,Ret:Attic,AH:LAUNDRY 6 150
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
SHGC: 13.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 35.6 SEER:16.00
SHGC:
d. U-Factor: N/A ft2 14.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Strip Heat 27.0 COP:1.00
Area Weighted Average Overhang Depth: 1.500 ft.
Area Weighted Average SHGC: 0.250
8. Skylights Description Area 15.Hot water systems
a.Electric Cap:50 gallons
a. U-Factor(AVG): N/A ft2 EF:0.98
SHGC(AVG): N/A
b. Conservation features
9. Floor Types Insulation Area None
a.Slab-On-Grade Edge Insulation R=0.0 1866.00 ft2 Credits(Performance method) None
b.N/A R= ft2
c.N/A R= ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building * °
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed CAD WE
based on installed Code compliant features.
Builder Signature: Date:
g O�-v"E STA
Address of New Home: City/FL Zip: '
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/21/2021 4:08 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1