Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETCccct . P L 0 L,�, I C ST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, B, D 1,2,3,4,5,6,7 Wood Shingles and Shakes Other A, B, D IA4,5,6,7 As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval S. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCIE Section A (General Information) Master Permit No. Process No. Contractors Name: Sunrise City CHDO Inc' License# CCC1327208 Job Address 7507 BANYAN ST Fort Pierce, FL 34951 ROOF CATEGORY Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance FV(1 Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) 200 Total (SF) 200 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Em r �yaT:' 1 i ■■■■■■■■■■■■■ ST LUCIE Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Polyglass Product Approval No.: FL1654 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': -37.8 Zone 1: -37.8 Zone 2: -63.5 Zone 3: -95.2 Max. Design Pressure, from the specific product approval system: Deck: Type: Plywood Gauge Thickness: 5/8 Slope: •5/12 Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: N/A Base Insultation Size and Thickness: N/A Base Insulation Fastener/Bonding Material: Top Insulation Layer: N/A Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: N/A Base Sheet(s) & No. of Ply(s): SBS-SA Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: SBS-SA Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':—" oc @ Lap, # Rows @ "oc Zone 1:—" oc @ Lap, # Rows @ "ac Zone 2:—" oc @ Lap, # Rows @ "ac Zone 3:—" oc @ Lap, # Rows @ n ac Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. ST. LUCIE WORKS ion D (Steep Slope Roof System) Roof tern Manufacturer: Notice cceptance Number: Minimum Des n Wind Pressures, If Applicable (From RAS 127 or Calculations): e 1: Zone 2e: Zone 2n: Zone 2r: Zone 3e: Zone 3r: Deck Type: Type Underlayment: Roof 5iope: 12 Insulation: Ridge Ventilation? Mean Roof Height: Fire Barrier: Fastener Type & Spa ' g: Adhesive pe Cap Sheet: Poof Covering: "ce & Size Drip LUCIE WORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf values e greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment methoeptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: x _ _J - Mg• = Mrj Product Approval Mi (Zone 2e: x ? = ) - Mg: = M,a Product Approval Mf (Zone 2n: x _ _) - Mg: = Mom, Product (Zone 2r: x _ ) - Mg: = M Product A one 3e: x _ - M9 = Mrs /rova Product ne 3r: _ ----� - M9 = Mrar Product AMethod 2 "Simplified Tile Calculations Per Table Be Required Moment of esistance (Mr) From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof lope 15, 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 .4 28.0 29 4 30.5 32.4 7:12 24. 25.9 A.1 28.2 30.0 *Must be used in conjunction with a list o mon • For Uplift based tile systems use Method 3. Cc equal to the Fr values, for each area of the rocq Method 3 " (Zone 1: x L =x W:= ) -W:_ (Zone 2e: x L =x W:= ) -W:_ (Zone 2n: x L =x W:= ) -W:_ (Zone 2r: x L =x W:= ) -W:_ (Zone 3e: x L =x W:= ) -W:_ (Zone 3r: x L =x W:= ) -W:1 ent based tile sy ems npare the valu s for F' with the values for Fr If the F' values are greater than or then the tile ttachment method is acceptable. lift Base Tile Calculations Per RAS 12T cos =Fr1 Product Approval F' s r =Free Product Approval F' c r =Fr2n Product Approval F' cos =Fr2r Product Approval F' cos r =Fr3e Product Approval F' cos r =Fr3r Product Approval F' Where to Obtain Infor ation Description Symbol Where to find Design Pressure Zo es 1, 2e, 2n, 2r, 3e, 3r From apple ble table in RAS 127 or by an engineering analysis prepared by based on ASCE 7 Mean Roof Height H Job Site Roof Slope 6 Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravi Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resista a Mg Calculated Minimum Attachment sistance F' Product Approval Required Uplift Resis nce Fr Calculated Average Tile Weig W Product Approval Tile Dimensions L = length W = width Product Approval All calculatio94ust be submitted to the building official at the time of permit application.