Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET LL ST. LUCIE WORKS U L ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code-Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A, B,C 1,2,3,4,5,6,7 Prescriptive BL R-RAS 150 A, B,C 2,4,5,6,7 Asphaltic Shi%les A, B,D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D,E 1,2,3,4,5,6,7 Metal Roofs A, B,D 1,2,3,4,5,6,7 Wood Shingles and A, B, D 1,2,4,5,6,7 Shakes Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1, Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128 4. Other Component of Product Approval 5, Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RoofinfoFeb21 Rev Feb 18,2021 ST. LUCIE WORKS Section A(General Information) Master Permit No. Process No. Contractors Name: SEAN CARTER License# CCC1329896 Job Address 8405 FORT WP,LTON AVE FT. PIERCE, FL ROOF CATEGORY ❑Low Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles M Asphaltic Shingles ❑Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance EX Reroofing ❑Recovering .ROOF SYSTEM INFORMATION Low Slope Roof Area(SF)_ Steep Sloped Roof Area(SF) 1008 Total(SF) 1008 Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sectior s and levels,clearly identify dimensions of elevated pressure zones and location of parapets. q d ll 1— cam,[ i c. R' �a !a 4� ( ! � 1 I _ r i � ! � i ST. LUCIE W RKS Section C (Low Slope Roof) Surfacing: Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment: manufacturer Zone 1':—"oc @ Lap,#Rows_® "o (If a component is not used,identify as"NA") Zone 1:_" oc @ Lap,#Rows 0 "o System Manufacturer:_ Zone 2:_"oc @ Lap,#Rows ® "oC Product Approval No.: Zone 3:—" oc @ Lap,#Rows_® "oo Number of Fasteners Per Insulation Board: Design Wind Pressures,From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3: Zone 1':_Zone 1: Zone 2:_ Zone 3: Illustrate Components Noted and Details as Applicable: Max. Design Pressure, frorn the specific product approval Woodblocking, Gutter, Edge Termination, Stripping, system: Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing,Coping, Etc.. Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base Type: Flashing,Component Material,Material'Thickness, Fastener Gauge Thickness:_ Type,Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Slope: Anchor/Base Sheet&No.clf Ply(s): Anchor/Base Sheet Fastener/Bonding Material: FT. Insulation Base Layer: Base Insultation Size and Thickness: Parapet Base Insulation Fastener/bonding Material: Height Top Insulation Layer: Top Insulation Size and Thi Ckness: FT. Top Insulation Fastener/Banding Material: Mean Base Sheet(s)&No.of Ply(i): Roof Base Sheet Fastener/Bond ng Material: Height Ply Sheet(s)'&No.of Ply(s : Ply Sheet Fastener/Bondin;Material: Top Ply: Top Ply Fastener/Bonding Material: ST. LUCIE Section D (Steep Slope R)of System) Roof System Manufacturer: C'/,F Notice of Acceptance Number; FL10124-R29 Minimum Design Wind Presst res, If Applicable(From RAS 127 or Calculations): .Zone 1: X ;:one 2e: Zone 2n: Zone 2r: Zone 3e: .Zone 3r: Deck Type: PLYWOOD J Type Underiayment: PEEL & STICK Roof Slope: 5 12 -- Insulation: N/A Fire Barrier: N/A Ridge Ventilation? Fastener Type&Spacing: N/A RIDGE �EN Adhesive Type: ( N/A Type Cap Sheet: F N/A Mean Roof Height: 1 STORY Roof Covering: SHINGLE Type&Size Drip 26GA 2,5 Edge: ST. LUCIE WORKS Section E(Tile Calculations) For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mf.If the Mf values are greater than or equal to the Mr values,for each area of the roof,then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: x = _�_Mg: =Mo Product Approval Mi (Zone 2e: x _ _�-Mg: =Mae Product Approval Mf (Zone 2n: x)L _ _�-Mg: =M,�, Product Approval Mf (Zone 2r: x _ _a-Mg: =M,& Product Approval Mf (Zone 3e: x _ Mg: =M„o Product Approval Mf (Zone 3r: x _ Mg: =Mrer Product Approval Mf Method 2"Simplified Tile Calculations Per Table Below" Required Moment of Resistance(Mr)From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32..8 34.9 6:12 26.4 28.0 1 29.4 30.5 32.4 7:12 24.4 25.9 1 27.1 28.2 30.0 *Must be used in conjunct ion with a list of moment based tile systems • For Uplift based tile syste ms use Method 3.Compare the values for F'with the values for Fr If the F'values are greater than or equal to the Fr values,for each area of the roof,then the tile attachment method is acceptable. Method 3"Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L =x W:= )-W: cos r =Fri Product Approval F' (Zone 2e: x L =x W:= )-W: cos r =Fr2e Product Approval F' (Zone 2n: x L =x W:= )-W: cos r =Fr2n Product Approval F' (Zone 2r: x L -x W:= )-W: cos r =Fr2r Product Approval F' (Zone 3e: x L =x W:=__)-W: cos r =Frse Product Approval F' (Zone 3r: x L --x W:=__)-W: cos r =Frsr Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure Zones 1,2e,2n,2r,3e,3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 6 Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravi•y M, Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance M, Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L=length W=width Product Approval All calculations must be submitted to the building official at the time of permit application.