APPROVED 006 HVAC Energy Calcs-signed
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: DAWSON RESIDENCE Builder Name: Street: SOUTHERN STAR DRIVE Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL, Permit Number: Owner: MICHAEL AND ROSAURA DAWSON Jurisdiction: ST LUCIE COUNTY Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Types(3299.2 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 2879.20 ft2 b.Frame-Wood,Adjacent R=13.0 420.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 11.Ceiling Types (3688.0 sqft.) Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=20.0 3377.00 ft2 6. Conditioned floor area above grade(ft2) 3377 b.Knee Wall(Unvented) R=20.0 311.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 7. Windows(519.5 sqft.) Description Area 12.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 175 a. U-Factor: Sgl,U=0.65 519.50 ft2 b.Sup: Attic,Ret:Attic,AH:Attic 6 125 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 42.0 SEER:16.00 c. U-Factor: N/A ft2 b.Central Unit 17.7 SEER:16.00 SHGC: 14.Heating systems kBtu/hr Efficiency ft Area Weighted Average Overhang Depth: 10.678 . Area Weighted Average SHGC: 0.250 a.Electric Strip Heat 27.0 COP:1.00 b.Electric Strip Heat 17.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15.Hot water systems SHGC(AVG): N/A a.Electric Cap:50 gallons 9. Floor Types (3377.0 sqft.) Insulation Area EF:0.980 a.Slab-On-Grade Edge Insulation R=0.0 3377.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 16.Credits None Glass/Floor Area: 0.154 Total Proposed Modified Loads: 94.62 PASS Total Baseline Loads: 102.18 1 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this 4 Code. calculation indicates compliance G'�D with the Florida Energy Code. PREPARED BY:Q.!�g�qjjyoBefore construction is completed DATE: 10-97-9021 this building will be inspected for �T14E Sr'4T compliance with Section 553.908 Q _ E I hereby certify that this building, as designed, is in compliance Florida Statutes.' with the Florida Energy OWNER/AGENT: BUILDING OFFICIAL: DATE: 11-8-21 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 10/26/2021 2:22 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: DAWSON RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3377 Lot# Owner Name: MICHAEL AND ROSAURA D Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: SOUTHERN STAR DRI Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City,State,Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 2419 26758 2 AHU 2 958 10034 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 FOYER 77 770 No 0 1 Yes Yes Yes 2 LAUNDRY RM 176 1760 No 0 1 Yes Yes Yes 3 BEDROOM 3 272 2720 No 0 1 1 Yes Yes Yes 4 CLST 3 24 240 No 0 1 Yes Yes Yes 5 CLST 2 24 240 No 0 1 Yes Yes Yes 6 BEDROOM 2 278 2780 No 0 1 1 Yes Yes Yes 7 BATH 3 60 600 No 0 1 No Yes Yes 8 ENTRY HALL 60 600 No 0 1 Yes Yes Yes 9 PANTRY 2 30 300 No 0 1 No Yes Yes 10 HALLWAY 40 400 No 0 1 No Yes Yes 11 PANTRY 1 30 300 No 0 1 No Yes Yes 12 KITCHEN 342 3420 Yes 0 1 Yes Yes Yes 13 BATH 2 60 600 No 0 1 Yes Yes Yes 14 DINING RM 306 3978 No 0 1 Yes Yes Yes 15 LIVING RM 550 7150 No 0 1 Yes Yes Yes 16 BATH 4 90 900 No 0 1 Yes Yes Yes 17 TOILET 30 300 No 0 1 Yes Yes Yes 18 WIC 2 90 900 No 0 1 Yes Yes Yes 19 WIC 1 138 1380 No 0 1 Yes Yes Yes 20 BATH 1 246 2460 No 0 1 Yes Yes Yes 21 BEDROOM 1 454 4994 No 0 1 1 Yes Yes Yes 10/26/2021 2:22 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation FOYER 11 ft 77 ft2 ____ 1 0 0 2 Slab-On-Grade Edge Insulation LAUNDRY RM 11 ft 176 ft2 ____ 1 0 0 3 Slab-On-Grade Edge Insulation BEDROOM 3 17 ft 272 ft2 ____ 1 0 0 4 Slab-On-Grade Edge Insulation CLST 3 2 ft 24 ft2 ____ 1 0 0 5 Slab-On-Grade Edge Insulation CLST 2 2 ft 24 ft2 ____ 1 0 0 6 Slab-On-Grade Edge Insulation BEDROOM 2 24 ft 278 ft2 ____ 1 0 0 7 Slab-On-Grade Edge Insulation BATH 3 1 ft 60 ft2 ____ 1 0 0 8 Slab-On-Grade Edge Insulation ENTRY HALL 7 ft 60 ft2 ____ 1 0 0 9 Slab-On-Grade Edge Insulation PANTRY 2 1 ft 30 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation HALLWAY 1 ft 40 ft2 ____ 1 0 0 11Slab-On-Grade Edge Insulation PANTRY 1 1 ft 30 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation KITCHEN 19 ft 342 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation BATH 2 6 ft 60 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation DINING RM 17 ft 306 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulation LIVING RM 17 ft 550 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation BATH 4 7 ft 90 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulation TOILET 6 ft 30 ft2 ____ 1 0 0 18SIab-On-Grade Edge Insulation WIC 2 loft 90 ft2 ____ 1 0 0 19SIab-On-Grade Edge Insulation WIC 1 12 ft 138 ft2 ____ 1 0 0 20SIab-On-Grade Edge Insulation BATH 1 14 ft 246 ft2 ____ 1 0 0 21SIab-On-Grade Edge Insulation BEDROOM 1 31 ft 454 ft2 ____ 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 3776 ft2 0 ft2 Light N 0.1 No 0.9 No 20 26.57 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 3377 ft2 N N 10/26/2021 2:22 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) FOYER 0 Blown 77 ft2 0.1 Wood 2 Under Attic(Unvented) LAUNDRY RM 0 Blown 176 ft2 0.1 Wood 3 Under Attic(Unvented) BEDROOM 3 0 Blown 272 ft2 0.1 Wood 4 Under Attic(Unvented) CLST 3 0 Blown 24 ft2 0.1 Wood 5 Under Attic(Unvented) CLST 2 0 Blown 24 ft2 0.1 Wood 6 Under Attic(Unvented) BEDROOM 2 0 Blown 278 ft2 0.1 Wood 7 Under Attic(Unvented) BATH 3 0 Blown 60 ft2 0.1 Wood 8 Under Attic(Unvented) ENTRY HALL 0 Blown 60 ft2 0.1 Wood 9 Under Attic(Unvented) PANTRY 2 0 Blown 30 ft2 0.1 Wood 10 Under Attic(Unvented) HALLWAY 0 Blown 40 ft2 0.1 Wood 11 Under Attic(Unvented) PANTRY 1 0 Blown 30 ft2 0.1 Wood 12 Under Attic(Unvented) KITCHEN 0 Blown 342 ft2 0.1 Wood 13 Under Attic(Unvented) BATH 2 0 Blown 60 ft2 0.1 Wood 14 Under Attic(Unvented) DINING RM 0 Blown 306 ft2 0.1 Wood 15 Under Attic(Unvented) LIVING RM 0 Blown 550 ft2 0.1 Wood 16 Under Attic(Unvented) BATH 4 0 Blown 90 ft2 0.1 Wood 17 Under Attic(Unvented) TOILET 0 Blown 30 ft2 0.1 Wood 18 Under Attic(Unvented) WIC 2 0 Blown 90 ft2 0.1 Wood 19 Under Attic(Unvented) WIC 1 0 Blown 138 ft2 0.1 Wood 20 Under Attic(Unvented) BATH 1 0 Blown 246 ft2 0.1 Wood 21 Under Attic(Unvented) BEDROOM 1 0 Blown 454 ft2 0.1 Wood 22 Knee Wall(Unvented) FOYER 20 Blown 17 ft2 0.11 Wood 23 Knee Wall(Unvented) BATH 1 20 Blown 54 ft2 0.11 Wood 24 Knee Wall(Unvented) WIC 2 20 Blown 15 ft2 0.11 Wood 25 Knee Wall(Unvented) BATH 4 20 Blown 18 ft2 0.11 Wood 26 Knee Wall(Unvented) KITCHEN 20 Blown 28 ft2 0.11 Wood 27 Knee Wall(Unvented) ENTRY HALL 20 Blown 18 ft2 0.11 Wood 28 Knee Wall(Unvented) BEDROOM 1 20 Blown 29 ft2 0.11 Wood 29 Knee Wall(Unvented) LIVING RM 20 Blown 37 ft2 0.11 Wood 30 Knee Wall(Unvented) DINING RM 20 Blown 34 ft2 0.11 Wood 31 Knee Wall(Unvented) BATH 2 20 Blown 9 ft2 0.11 Wood 32 Knee Wall(Unvented) BEDROOM 2 20 Blown 24 ft2 0.11 Wood 33 Knee Wall(Unvented) LAUNDRY RM 20 Blown 28 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belowo 1 NW Exterior Concrete Block-Int Insul FOYER 4.1 11 0 10 0 110.0 ft2 0 0 0.1 0 2 SW Exterior Concrete Block-Int InsuLAUNDRY R 4.1 11 0 10 0 110.0 ft2 0 0 0.1 0 3 NW Garage Frame-Wood LAUNDRY R 13 16 0 10 0 160.0 ft2 0 0.1 0.1 0 4 NE Garage Frame-Wood LAUNDRY R 13 3 0 10 0 30.0 ft2 0 0.1 0.1 0 5 SW Exterior Concrete Block-Int InsuBEDROOM 3 4.1 17 0 10 0 170.0 ft2 0 0 0.1 0 6 SW Exterior Concrete Block-Int Insul CLST 3 4.1 2 0 10 0 20.0 ft2 0 0 0.1 0 7 SW Exterior Concrete Block-Int Insul CLST 2 4.1 2 0 10 0 20.0 ft2 0 0 0.1 0 10/26/2021 2:22 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below o 8 E Exterior Concrete Block-Int InsuBEDROOM 2 4.1 6 5 10 0 64.2 ft2 0 0 0.1 0 9 SE Exterior Concrete Block-Int InsuBEDROOM 2 4.1 11 0 10 0 110.0 ft2 0 0 0.1 0 10 SW Exterior Concrete Block-Int InsuBEDROOM 2 4.1 18 0 10 0 180.0 ft2 0 0 0.1 0 11 NE Exterior Concrete Block-Int InsuENTRY HALL 4.1 6 0 10 0 60.0 ft2 0 0 0.1 0 12 NW Exterior Concrete Block-Int InsuENTRY HALL 4.1 1 0 10 0 10.0 ft2 0 0 0.1 0 13 NW Garage Frame-Wood ENTRY HALL 13 5 0 10 0 50.0 ft2 0 0.1 0.1 0 14 NE Exterior Concrete Block-Int Insul KITCHEN 4.1 3 0 10 0 30.0 ft2 0 0 0.1 0 15 NW Exterior Concrete Block-Int Insul KITCHEN 4.1 16 0 10 0 160.0 ft2 0 0 0.1 0 16 SE Exterior Concrete Block-Int Insul BATH 2 4.1 6 0 10 0 60.0 ft2 0 0 0.1 0 17 NE Exterior Concrete Block-Int InsulDINING RM 4.1 5 0 13 0 65.0 ft2 0 0 0.1 0 18 SE Exterior Concrete Block-Int InsuIDINING RM 4.1 18 0 13 0 234.0 ft2 0 0 0.1 0 19 SE Exterior Concrete Block-Int Insul LIVING RM 4.1 25 0 13 0 325.0 ft2 0 0 0.1 0 20 NE Exterior Concrete Block-Int Insul BATH 4 4.1 1 0 10 0 10.0 ft2 0 0 0.1 0 21 SW Exterior Concrete Block-Int Insul BATH 4 4.1 3 0 10 0 30.0 ft2 0 0 0.1 0 22 NW Exterior Concrete Block-Int Insul BATH 4 4.1 9 0 10 0 90.0 ft2 0 0 0.1 0 23 NE Exterior Concrete Block-Int Insul TOILET 4.1 6 0 10 0 60.0 ft2 0 0 0.1 0 24 NW Exterior Concrete Block-Int Insul WIC 2 4.1 10 0 10 0 100.0 ft2 0 0 0.1 0 25 NE Exterior Concrete Block-Int Insul WIC 1 4.1 12 0 10 0 120.0 ft2 0 0 0.1 0 26 NE Exterior Concrete Block-Int Insul BATH 1 4.1 9 0 10 0 90.0 ft2 0 0 0.1 0 27 SE Exterior Concrete Block-Int Insul BATH 1 4.1 2 0 10 0 20.0 ft2 0 0 0.1 0 28 SW Exterior Concrete Block-Int Insul BATH 1 4.1 18 0 10 0 180.0 ft2 0 0 0.1 0 29 NW Garage Frame-Wood BATH 1 13 18 0 10 0 180.0 ft2 0 0.1 0.1 0 30 NE Exterior Concrete Block-Int InsuBEDROOM 1 4.1 22 0 11 0 242.0 ft2 0 0 0.1 0 31 SE Exterior Concrete Block-Int InsuBEDROOM 1 4.1 19 0 11 0 209.0 ft2 0 0 0.1 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated ENTRY HALL None .23 3 8 24 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW 1 Metal Low-E Single Yes 0.65 0.25 Y 48.0 ft2 8 ft 0 in 1 ft 4 in None None 2 SW 2 Metal Low-E Single Yes 0.65 0.25 Y 12.0 ft2 2 ft 0 in 1 ft 4 in None None 3 SW 5 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 4 SW 10 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 5 NW 15 Metal Low-E Single Yes 0.65 0.25 Y 24.0 ft2 8 ft 0 in 1 ft 4 in None None 6 SE 16 Metal Low-E Single Yes 0.65 0.25 Y 21.3 ft2 20 ft 0 in 1 ft 4 in None None 7 SE 18 Metal Low-E Single Yes 0.65 0.25 Y 96.0 ft2 20 ft 0 in 1 ft 4 in None None 8 SE 19 Metal Low-E Single Yes 0.65 0.25 Y 128.0 ft2 12 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 9 NW 22 Metal Low-E Single Yes 0.65 0.25 Y 24.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 10 NE 23 Metal Low-E Single Yes 0.65 0.25 Y 8.2 ft2 2 ft 0 in 1 ft 4 in None None 10/26/2021 2:22 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 11 NE 26 Metal Low-E Single Yes 0.65 0.25 Y 8.0 ft2 2 ft 0 in 1 ft 4 in None None 12 SW 28 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 8 ft 0 in 1 ft 4 in None None 13 NE 30 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 14 SE 31 Metal Low-E Single Yes 0.65 0.25 Y 45.0 ft2 12 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 1672 ft2 1672 ft2 42 ft loft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000346 3066 168.21 315.8 .1021 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COP:1 17 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 42 kBtu/hr 1260 cfm 0.8 1 sys#1 2 Central Unit/ Split Single SEER: 16 17.7 kBtu/hr 531 cfm 0.8 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 18 ft2 Prop.Leak Free Attic ---cfm 72.6 cfm 0.03 0.50 1 1 2 Attic 6 125 ft2 Attic 13 ft2 Prop.Leak Free Attic ---cfm 28.7 cfm 0.03 0.50 2 2 10/26/2021 2:22 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb Mar Apr May rj Jun rj Jul rj Aug �Xj Se Oct Nov Dec Heatin HJan HFeb Mar Apr May Jun Jul Au Sep Oct Nov Dec Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftz Oft 0.3 FOYER Default(8 Ibs/sq.ft. ftz ft 0.3 LAUNDRY RM Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ftz ft 0.3 ENTRY HALL Default(8 Ibs/sq.ft. ftz ft 0.3 PANTRY 2 Default(8 Ibs/sq.ft. ftz ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ftz ft 0.3 PANTRY 1 Default(8 Ibs/sq.ft. ftz ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ftz ft 0.3 DINING RM Default(8 Ibs/sq.ft. ftz ft 0.3 LIVING RM Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 4 Default(8 Ibs/sq.ft. ftz ft 0.3 TOILET Default(8 Ibs/sq.ft. ftz ft 0.3 WIC 2 Default(81bs/sq.ft. ftz ft 0.3 WIC 1 Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 1 10/26/2021 2:22 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 7 of 7 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: DAWSON RESIDENCE Builder Name: Street: SOUTHERN STAR DRIVE Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL, Permit Number: Y U Owner: MICHAEL AND ROSAURA DAWSON Jurisdiction: ST LUCIE COUNTY w Design Location: FL,Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation,insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or ceiling Concealed When required to be sealed,concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer.Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Nates and walls or ceilin s. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 10/26/2021 2:22 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the EnergyPerformance Index, the more efficient the home. SOUTHERN STAR DRIVE, FORT PIERCE, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 2879.20 ft2 b.Frame-Wood,Adjacent R=13.0 420.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 11.Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=20.0 3377.00 ft2 6. Conditioned floor area(ft2) 3377 b.Knee Wall(Unvented) R=20.0 311.00 ft2 7. Windows- Description Area c.N/A R= ft2 a. U-Factor: Sgl,U=0.65 519.50 ft2 12.Ducts,location&insulation level R ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 175 SHGC: SHGC=0.25 b.Sup: Attic,Ret:Attic,AH:Attic 6 125 b. U-Factor: N/A ft2 SHGC: 13.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 42.0 SEER:16.00 SHGC: b.Central Unit 17.7 SEER:16.00 d. U-Factor: N/A ft2 14.Heating systems kBtu/hr Efficiency SHGC: a.Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 10.678 ft. b.Electric Strip Heat 17.0 COP:1.00 Area Weighted Average SHGC: 0.250 8. Skylights Description Area 15.Hot water systems a.Electric Cap:50 gallons a. U-Factor(AVG): N/A ft2 EF:0.98 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 3377.00 ft2 Credits(Performance method) None b.N/A R= ft2 c.N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building * ° Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed CAD WE based on installed Code compliant features. Builder Signature: Date: g O��"E STA Address of New Home: City/FL Zip: ' *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/26/2021 2:22 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 L--r wrigni pro ect SummaryJob: AHU 1 Date: Oct 26,2021 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: MICHAELAND ROSAURA DAWSON SOUTHERN STAR DRIVE, FORT PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 27067 Btuh Structure 19725 Btuh Ducts 7461 Btuh Ducts 10825 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 34528 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 29023 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4880 Btuh Ducts 2975 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft2) 2419 2419 Equipment latent load 7855 Btuh Volume (ft3) 26758 26758 Air changes/hour 0.25 0.13 Equipment Total Load (Sen+Lat) 36878 Btuh Equiv.AVF (cfm) 111 59 Req. total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond CA16NA04200GOBO AHRI ref Coil FX4DNF049L AHRI ref 202024777 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 9.2 kW Sensible cooling 29400 Btuh Heating output 31393 Btuh Latent cooling 12600 Btuh Temperature rise 20 °F Total cooling 42000 Btuh Actual air flow 1400 cfm Actual air flow 1400 cfm Air flow factor 0.041 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -1)Oft—ord- W riig1 2021-Oct-26 13:35:42 _ Right-SuiteO Universal 2021 21.0.02 RSU08101 Page 1 ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW L--r wrigni Project Summary Job: AHU 2 Date: Oct 26,2021 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: MICHAELAND ROSAURA DAWSON SOUTHERN STAR DRIVE, FORT PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 12714 Btuh Structure 10155 Btuh Ducts 2272 Btuh Ducts 3199 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 14986 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 12686 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2263 Btuh Ducts 836 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 958 958 Equipment latent load 3098 Btuh Volume (ft3) 10034 10034 Air changes/hour 0.36 0.20 Equipment Total Load (Sen+Lat) 15784 Btuh Equiv.AVF (cfm) 61 33 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond CA16NW01800GOA0 AHRI ref Coil FX4DNF019L AHRI ref 9200856 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input 3.9 kW Sensible cooling 12390 Btuh Heating output 13470 Btuh Latent cooling 5310 Btuh Temperature rise 21 °F Total cooling 17700 Btuh Actual air flow 590 cfm Actual air flow 590 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -1)Oft—ord- W riig1 2021-Oct-26 13:35:42 _ Right-SuiteO Universal 2021 21.0.02 RSU08101 Page 2 ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW IL : W I Nyl l Right-J®Worksheet Job: AHU 1 Date: Oct 26,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name AHU 1 FOYER 2 Exposed wall 171.3 ft 11.0 ft 3 Room height 11.1 ft 10.0 ft heat/cool 4 Room dimensions 11.0 x 7.0 ft 5 Room area 2419.0 ft2 77.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 ne 4.00 2.19 165 165 661 361 0 0 0 0 !;ICGII 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 13A-4ocs 0.143 e 4.00 2.19 64 64 256 140 0 0 0 0 13A-40cs 0.143 se 4.00 2.19 729 484 1937 1058 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 21 7 388 497 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 96 30 1747 2238 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 17.96 128 40 2330 2298 0 0 0 0 V�✓ 13A-40cs 0.143 sw 4.00 2.19 530 458 1834 1002 0 0 0 0 I�GCI 2 glazing,clr low-e 0.650 sw 18.20 19.57 12 7 218 235 0 0 0 0 2 glazing,clr low-e 0,650 sw 18,20 21,07 60 30 1092 1264 0 0 0 0 VI✓ 13A-40cs 0.143 nw 4.00 2.19 370 274 1097 599 110 62 248 136 l;; CCGII 2 glazing,clr low-e 0.650 nw 18.20 26.88 24 0 437 645 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 17.04 24 0 437 409 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 26.88 48 0 874 1290 48 0 874 1290 C 16X19-0md 0.408 1.59 1.37 2419 2419 3835 3310 77 77 122 105 F 22A-tph 1.358 38.02 0.00 2419 171 6515 0 77 11 418 0 6 c)AED excursion 0 147 Envelope loss/gain 23657 15347 1662 1678 12 a) Infiltration 3410 979 202 58 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 3400 0 Subtotal(lines 6 to 13) 27067 19725 1864 1736 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 -1864 -1736 14 Subtotal 27067 19725 0 0 15 Duct loads 28% 55% 7461 10825 28% 55% 0 0 Total room load 34528 30550 0 0 Air required(cfm) 1400 1400 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Oct-2613:35:42 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 1 ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW IL : W I Nyl l Right-J®Worksheet Job: AHU 1 Date: Oct 26,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name LAUNDRYRM BEDROOM 3 2 Exposed wall 11.0 ft 17.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 16.0 x 11.0 ft 16.0 x 17.0 ft 5 Room area 176.0 ft2 272.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 !;ICGII 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 13A-40cs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 17.96 0 0 0 0 0 0 0 0 V�✓ 13A-40cs 0.143 sw 4.00 2.19 110 98 392 214 170 140 561 306 I�GCI 2 glazing,clr low-e 0.650 sw 18.20 19.57 12 7 218 235 0 0 0 0 2 glazing,clr low-e 0,650 sw 18,20 21,07 0 0 0 0 30 15 546 632 VI✓ 13A-40cs 0.143 nw 4. 2. 0 0 0 0 0 0 0 0 l;; CCGII 2 glazing,clr low-e 0.650 nw 18.2020 26.8888 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 17.04 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 176 176 279 241 272 272 431 372 F 22A-tph 1.358 38.02 0.00 176 11 418 0 272 17 646 0 6 c)AED excursion -93 78 Envelope loss/gain 1308 597 2184 1388 12 a) Infiltration 202 58 312 90 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 700 0 Subtotal(lines 6 to 13) 1510 1355 2496 1478 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 280 85 346 114 14 Subtotal 1790 1440 2843 1592 15 Duct loads 28% 55% 493 790 28% 55% 784 874 Total room load 2283 2230 3626 2465 Air required(cfm) 931 102 147 113 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Oct-2613:35:42 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 2 ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW IL : W I Nyl l Right-J®Worksheet Job: AHU 1 Date: Oct 26,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name CLST 3 CLST 2 2 Exposed wall 2.0 ft 2.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 12.0 x 2.0 ft 12.0 x 2.0 ft 5 Room area 24.0 ft2 24.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 !;ICGII 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 13A-40cs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 17.96 0 0 0 0 0 0 0 0 V�✓ 13A-40cs 0.143 sw 4.00 2.19 20 20 80 44 20 20 80 44 I�GCI 2 glazing,clr low-e 0.650 sw 18.20 19.57 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0,650 sw 18,20 21,07 0 0 0 0 0 0 0 0 VI✓ 13A-40cs 0.143 nw 4. 2. 0 0 0 0 0 0 0 0 l;; CCGII 2 glazing,clr low-e 0.650 nw 18.2020 26.8888 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 17.04 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 24 24 38 33 24 24 38 33 F 22A-tph 1.358 38.02 0.00 24 2 76 0 24 2 76 0 6 c)AED excursion -13 -13 Envelope loss/gain 194 64 194 64 12 a) Infiltration 37 11 37 11 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 231 75 231 75 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -231 -75 -231 -75 14 Subtotal 0 0 0 0 15 Duct loads 28% 55% 0 0 28% 55% 0 0 Total room load 0 0 0 0 Air required(cfm) 01 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Oct-2613:35:42 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 3 ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW IL : W I Nyl l Right-J®Worksheet Job: AHU 1 Date: Oct 26,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 BATH 3 2 Exposed wall 35.3 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 278.0 ft 6.0 x 10.0 ft 5 Room area 278.0 ft2 60.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 !;ICGII 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 13A-4ocs 0.143 e 4.00 2.19 64 64 256 140 0 0 0 0 13A-40cs 0.143 se 4.00 2.19 110 110 440 241 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 17.96 0 0 0 0 0 0 0 0 V�✓ 13A-40cs 0.143 sw 4.00 2.19 180 150 601 328 0 0 0 0 I�GCI 2 glazing,clr low-e 0.650 sw 18.20 19.57 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0,650 sw 18,20 21,07 30 15 546 632 0 0 0 0 VI✓ 13A-40cs 0.143 nw 4. 2. 0 0 0 0 0 0 0 0 l;; CCGII 2 glazing,clr low-e 0.650 nw 18.2020 26.8888 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 17.04 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 278 278 441 380 60 60 95 82 F 22A-tph 1.358 38.02 0.00 278 35 1344 0 60 0 0 0 6 c)AED excursion 5 -55 Envelope loss/gain 3628 1726 95 27 12 a) Infiltration 650 186 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 300 Subtotal(lines 6 to 13) 4277 1912 95 327 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 241 82 210 64 14 Subtotal 4519 1995 305 391 15 Duct loads 28% 55% 1246 1095 28% 55% 84 214 Total room load 5765 3089 389 605 Air required(cfm) 234 142 16 28 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Oct-2613:35:42 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 4 ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW IL : W I Nyl l Right-J®Worksheet Job: AHU 1 Date: Oct 26,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name ENTRY HALL PANTRY 2 2 Exposed wall 7.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 60.0 ft 6.0 x 5.0 ft 5 Room area 60.0 ft2 30.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 ne 4.00 2.19 60 60 240 131 0 0 0 0 !;ICGII 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 13A-40cs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 17.96 0 0 0 0 0 0 0 0 V�✓ 13A-40cs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 I�GCI 2 glazing,clr low-e 0.650 sw 18.20 19.57 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0,650 sw 18,20 21,07 0 0 0 0 0 0 0 0 VI✓ 13A-40cs 0.143 nw 4. 2. 10 10 40 22 0 0 0 0 l;; CCGII 2 glazing,clr low-e 0.650 nw 18.2020 26.8888 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 17.04 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 60 60 95 82 30 30 48 41 F 22A-tph 1.358 38.02 0.00 60 7 266 0 30 0 0 0 6 c)AED excursion -39 -6 Envelope loss/gain 642 196 48 35 12 a) Infiltration 128 37 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 770 233 48 35 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -770 -233 16 12 14 Subtotal 0 0 63 47 15 Duct loads 28% 55% 0 0 28% 55% 17 26 Total room load 0 0 81 73 Air required(cfm) 01 01 3 3 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Oct-2613:35:42 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 5 ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW IL : W I Nyl l Right-J®Worksheet Job: AHU 1 Date: Oct 26,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name HALLWAY PANTRY 1 2 Exposed wall 0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 10.0 x 4.0 ft 6.0 x 5.0 ft 5 Room area 40.0 ft2 30.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 !;ICGII 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 13A-40cs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 17.96 0 0 0 0 0 0 0 0 V�✓ 13A-40cs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 I�GCI 2 glazing,clr low-e 0.650 sw 18.20 19.57 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0,650 sw 18,20 21,07 0 0 0 0 0 0 0 0 VI✓ 13A-40cs 0.143 nw 4. 2. 0 0 0 0 0 0 0 0 l;; CCGII 2 glazing,clr low-e 0.650 nw 18.2020 26.8888 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 17.04 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 40 40 63 55 30 30 48 41 F 22A-tph 1.358 38.02 0.00 40 0 0 0 30 0 0 0 6 c)AED excursion -8 -6 Envelope loss/gain 63 47 48 35 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 63 47 48 35 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -63 -47 16 12 14 Subtotal 0 0 63 47 15 Duct loads 28% 55% 0 0 28% 55% 17 26 Total room load 0 0 81 73 Air required(cfm) 01 01 3 3 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Oct-2613:35:42 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 6 ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW IL : W I Nyl l Right-J®Worksheet Job: AHU 1 Date: Oct 26,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name KITCHEN BATH 2 2 Exposed wall 19.0 ft 6.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 342.0 ft 6.0 x 10.0 ft 5 Room area 342.0 ft2 60.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 ne 4.00 2.19 30 30 120 66 0 0 0 0 !;ICGII 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 13A-40cs 0.143 se 4.00 2.19 0 0 0 0 60 39 155 85 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 21 7 388 497 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 17.96 0 0 0 0 0 0 0 0 V�✓ 13A-40cs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 I�GCI 2 glazing,clr low-e 0.650 sw 18.20 19.57 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0,650 sw 18,20 21,07 0 0 0 0 0 0 0 0 VI✓ 13A-40cs 0.143 nw 4.00 2.19 160 136 545 298 0 0 0 0 l;; CCGII 2 glazing,clr low-e 0.650 nw 18.20 26.88 24 0 437 645 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 17.04 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 342 342 542 468 60 60 95 82 F 22A-tph 1.358 38.02 0.00 342 19 722 0 60 6 228 0 6 c)AED excursion -381 31 Envelope loss/gain 2366 1095 866 695 12 a) Infiltration 349 100 110 32 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2400 0 Subtotal(lines 6 to 13) 2715 3595 976 726 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 849 680 0 0 14 Subtotal 3564 4275 976 726 15 Duct loads 28% 55% 982 2346 28% 55% 269 399 Total room load 4546 6621 1246 1125 Air required(cfm) 1841 303 51 52 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Oct-2613:35:42 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 7 ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW IL : W I Nyl l Right-J®Worksheet Job: AHU 1 Date: Oct 26,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name DINING RM LIVING RM 2 Exposed wall 23.0 ft 25.0 ft 3 Room height 13.0 ft heat/cool 13.0 ft heat/cool 4 Room dimensions 18.0 x 17.0 ft 25.0 x 22.0 ft 5 Room area 306.0 ft2 550.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 ne 4.00 2.19 65 65 260 142 0 0 0 0 !;ICGII 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 13A-40cs 0.143 se 4.00 2.19 234 138 553 302 325 197 789 431 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 96 30 1747 2238 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 17.96 0 0 0 0 128 40 2330 2298 V�✓ 13A-40cs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 I�GCI 2 glazing,clr low-e 0.650 sw 18.20 19.57 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0,650 sw 18,20 21,07 0 0 0 0 0 0 0 0 VI✓ 13A-40cs 0.143 nw 4. 2. 0 0 0 0 0 0 0 0 l;; CCGII 2 glazing,clr low-e 0.650 nw 18.2020 26.8888 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 17.04 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 306 306 485 419 550 550 872 752 F 22A-tph 1.358 38.02 0.00 306 23 875 0 550 25 951 0 6 c)AED excursion 119 153 Envelope loss/gain 3920 3220 4941 3635 12 a) Infiltration 549 157 596 171 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 4468 3378 5537 3806 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 8 6 671 625 14 Subtotal 4476 3383 6209 4431 15 Duct loads 28% 55% 1234 1857 28% 55% 1711 2432 Total room load 5710 5240 7920 6863 Air required(cfm) 2321 240 321 314 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Oct-2613:35:42 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 8 ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW IL : W I Nyl l Right-J®Worksheet Job: AHU 1 Date: Oct 26,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BATH 4 2 Exposed wall 13.0 ft 3 Room height 10.0 ft heat/cool 4 Room dimensions 9.0 x 10.0 ft 5 Room area 90.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vh13A-4ocs 0.143 ne 4.00 2.19 10 10 40 22 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 2 glazing,clr low-e 0.650 ne 0.00 0.00 0 0 0 0 11 W 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 23.31 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 17.96 0 0 0 0 V�✓ 13A-4ocs 0.143 sw 4.00 2.19 30 30 120 66 I�CCI, 2 glazing,clr low-e 0.650 sw 18.20 19.57 0 0 0 0 2 glazing,clr low-e 0.650 sw 18.20 21.07 0 0 0 0 V)/ 13A-4ocs 0. nw 4. 2. 90 66 264 144 2 glazing,clr low-e 0.650650 nw 18.2020 26.8888 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 17.04 24 0 437 409 2 glazing,clr low-e 0.650 nw 18.20 26.88 0 0 0 0 Cr 16X19-0md 0.408 1.59 1.37 90 90 143 123 F 22A-tph 1.358 38.02 0.00 90 13 494 0 6 c)AED excursion 81 Envelope loss/gain 1498 845 12 a) Infiltration 239 68 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 1737 913 Less external load 0 0 Less transfer 0 0 Redistribution 522 486 14 Subtotal 2259 1399 15 Duct loads 28% 55% 623 768 Total room load 2881 2167 Air required(cfm) 1 1 1171 99 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Oct-2613:35:42 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 9 ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW IL : W I Nyl l Right-J®Worksheet Job: AHU 2 Date: Oct 26,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name AHU 2 TOILET 2 Exposed wall 98.0 ft 6.0 ft 3 Room height 10.5 ft 10.0 ft heat/cool 4 Room dimensions 5.0 x 6.0 ft 5 Room area 958.0 ft2 30.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 ne 4.00 2.19 512 466 1865 1019 60 52 208 113 !;ICGII 2 glazing,clr low-e 0.650 ne 18.20 26.88 8 0 146 215 0 0 0 0 2 glazing,clr low-e 0.650 ne 18.20 26.88 8 0 149 219 8 0 149 219 2 glazing,clr low-e 0.650 ne 18.20 26.88 30 0 546 806 0 0 0 0 11 W 13A-4ocs 0.143 e 0.00 0.00 0 0 0 0 0 0 0 0 13A-40cs 0.143 se 4.00 2.19 229 184 737 403 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 21.07 45 22 819 948 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 V�✓ 13A-40cs 0.143 sw 4.00 2.19 180 165 661 361 0 0 0 0 I�GCI 2 glazing,clr low-e 0.650 sw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0,650 sw 18,20 21.07 15 7 273 316 0 0 0 0 VI✓ 13A-40cs 0.143 nw 4.00 2.19 100 100 400 219 0 0 0 0 l;; CCGII 2 glazing,clr low-e 0.650 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 958 958 1519 1311 30 30 48 41 F 22A-tph 1.358 38.02 0.00 958 98 3726 0 30 6 228 0 6 c)AED excursion 0 -21 Envelope loss/gain 10841 5817 632 353 12 a) Infiltration 1874 538 110 32 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 3800 500 Subtotal(lines 6 to 13) 12714 10155 742 885 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 12714 10155 742 885 15 Duct loads 18% 31% 2272 3199 18% 31% 133 279 Total room load 14986 13354 875 1163 Air required(cfm) 590 590 34 51 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Oct-2613:35:42 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 10 ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW IL : W I Nyl l Right-J®Worksheet Job: AHU 2 Date: Oct 26,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name WIC 2 WIC 1 2 Exposed wall 10.0 ft 12.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 10.0 x 9.0 ft 1.0 x 138.0 ft 5 Room area 90.0 ft2 138.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 120 120 480 263 !;ICGII 2 glazing,clr low-e 0.650 ne 18.20 26.88 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 18.20 26.88 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 18.20 26.88 0 0 0 0 0 0 0 0 11 W 13A-4ocs 0.143 e 0.00 0.00 0 0 0 0 0 0 0 0 13A-40cs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 18.20 21.07 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 V�✓ 13A-40cs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 I�GCI 2 glazing,clr low-e 0.650 sw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0,650 sw 18,20 21.07 0 0 0 0 0 0 0 0 VI✓ 13A-40cs 0.143 nw 4.00 2.19 100 100 400 219 0 0 0 0 l;; CCGII 2 glazing,clr low-e 0.650 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 90 90 143 123 138 138 219 189 F 22A-tph 1.358 38.02 0.00 90 10 380 0 138 12 456 0 6 c)AED excursion -21 -23 Envelope loss/gain 923 321 1156 428 12 a) Infiltration 184 53 220 63 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 500 Subtotal(lines 6 to 13) 1107 874 1376 991 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1107 874 1376 991 15 Duct loads 18% 31% 198 275 18% 31% 246 312 Total room load 1305 1149 1622 1304 Air required(cfm) 51 51 64 58 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Oct-2613:35:42 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 11 ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW IL : W I Nyl l Right-J®Worksheet Job: AHU 2 Date: Oct 26,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BATH 1 BEDROOM 1 2 Exposed wall 29.0 ft 41.0 ft 3 Room height 10.0 ft heat/cool 11.0 ft heat/cool 4 Room dimensions 1.0 x 246.0 ft 1.0 x 454.0 ft 5 Room area 246.0 ft2 454.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 ne 4.00 2.19 90 82 328 179 242 212 849 464 !;ICGII 2 glazing,clr low-e 0.650 ne 18.20 26.88 8 0 146 215 0 0 0 0 2 glazing,clr low-e 0.650 ne 18.20 26.88 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 ne 18.20 26.88 0 0 0 0 30 0 546 806 11 W 13A-4ocs 0.143 e 0.00 0.00 0 0 0 0 0 0 0 0 13A-40cs 0.143 se 4.00 2.19 20 20 80 44 209 164 657 359 2 glazing,clr low-e 0.650 se 18.20 21.07 0 0 0 0 45 22 819 948 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 V�✓ 13A-40cs 0.143 sw 4.00 2.19 180 165 661 361 0 0 0 0 I�GCI 2 glazing,clr low-e 0.650 sw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0,650 sw 18,20 21.07 15 7 273 316 0 0 0 0 VI✓ 13A-40cs 0.143 nw 4.00 2. 0 0 0 0 0 0 0 0 l;; CCGII 2 glazing,clr low-e 0.650 nw 0.00 0.0000 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 nw 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 246 246 390 337 454 454 720 621 F 22A-tph 1.358 38.02 0.00 246 29 1103 0 454 41 1559 0 6 c)AED excursion 93 -29 Envelope loss/gain 2980 1545 5149 3169 12 a) Infiltration 532 153 828 238 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 1800 Subtotal(lines 6 to 13) 3513 2198 5977 5207 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3513 2198 5977 5207 15 Duct loads 18% 31% 628 692 18% 31% 1068 1640 Total room load T4140 2890 7045 6847 Air required(cfm) 1 631 128 277 303 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Oct-2613:35:42 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 12 ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW L-7 wrignI Duct System Summary Job: Date: Oct 26,2021 AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: MICHAEL AND ROSAURADAWSON SOUTHERN STAR DRIVE, FORT PIERCE, FL Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply/ return available pressure 0.500/ 0.500 in H2O 0.500/0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 1400 cfm 1400 cfm Total effective length (TEL) 171 ft Supply Branch DetailTable Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln (ft) Trunk BATH 2 c 1125 51 52 1.000 6.0 Ox 0 VIFx 34.4 135.0 st5 BATH 3 c 605 16 28 1.000 5.0 Ox 0 VIFx 15.9 115.0 st 1 BATH 4 h 2881 117 99 1.000 7.0 Ox 0 VIFx 41.5 115.0 st2 BEDROOM 2 h 5765 234 142 1.000 8.0 Ox0 VIFx 35.4 135.0 st5 BEDROOM 3 h 3626 147 113 1.000 7.0 Ox0 VIFx 17.5 115.0 st1 DINING RM c 5240 232 240 1.000 8.0 Ox0 VIFx 35.9 135.0 st5 KITCHEN c 3311 92 152 1.000 8.0 Ox0 VIFx 24.7 115.0 st1 KITCHEN-A c 3311 92 152 1.000 8.0 Ox0 VIFx 23.5 115.0 st1 LAUNDRY RM c 2230 93 102 1.000 7.0 Ox0 VIFx 3.0 95.0 LIVING RM h 3960 161 157 1.000 8.0 Ox0 VIFx 42.4 115.0 st2 LIVING RM-A h 3960 161 157 1.000 8.0 Ox0 VIFx 46.8 115.0 st2 PANTRY c 73 3 3 1.000 4.0 Ox0 VIFx 31.0 135.0 st5 PANTRY c 73 3 3 1.000 4.0 Ox0 VIFx 16.0 115.0 st1 • • Trunk Detail Table Trunk Htg CIg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 Peak AVF 438 414 1.000 558 12.0 0 x 0 VinlFlx st5 Peak AVF 519 437 1.000 661 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 869 884 1.000 827 14.0 0 x 0 VinlFlx - --eft- 1•F wrigl 2021-Oct-26 13:35:49 Right-SuiteO Universal 2021 21.0.02 RSU08101 Page 1 �L u ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb3 Ox0 1400 1400 0 0 0 0 Ox 0 VIFx — --311ft°S-'1•F wrigl 2021-Oct-26 13:35:49 Right-SuiteO Universal 2021 21.0.02 RSU08101 Page 2 �L u ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW L-7 wrignI Duct System Summary Job: Date: Oct 26,2021 AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: MICHAEL AND ROSAURADAWSON SOUTHERN STAR DRIVE, FORT PIERCE, FL Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply/ return available pressure 0.500/ 0.500 in H2O 0.500/0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 590 cfm 590 cfm Total effective length (TEL) 138 ft Supply Branch DetailTable Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln (ft) Trunk BATH h 4140 163 128 1.000 7.0 Ox0 VIFx 20.2 115.0 st4 BEDROOM 1 c 3424 139 151 1.000 8.0 Ox0 VIFx 21.6 115.0 st3 BEDROOM 1-A c 3424 139 151 1.000 8.0 Ox0 VIFx 22.6 115.0 st3 TOILET c 1163 34 51 1.000 6.0 Ox0 VIFx 21.2 115.0 st4 WIC 1 h 1622 64 58 1.000 6.0 Ox 0 VIFx 20.2 115.0 st4 WIC 2 h 1305 51 51 1.000 6.0 Ox 0 VIFx 3.2 95.0 SupplyDetail Table Trunk Htg CIg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 277 303 1.000 685 9.0 0 x 0 VinlFlx st4 Peak AVF 261 237 1.000 591 9.0 0 x 0 VinlFlx TableReturn Branch Detail Grille Htg CIg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox0 590 590 0 0 0 0 Ox 0 VIFx — --eft— 1•F wrigl 2021-Oct-26 13:35:49 Right-SuiteO Universal 2021 21.0.02 RSU08101 Page 3 �L u ...oft HVAC\DAWSON RESIDENCE-SOUTHERN STAR DR.rup Calc=MJ8 Front Door faces: NW This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.