Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT EVALUATION REPORT SWINGING EXTERIOR DOOR (2)
R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Registry License No. 9813 Product Category Sub Category Manufacturer Product Name Therma Tru Corporation Fiber -Classic and Smooth -Star Exterior Swinging Exterior Door 118 Industrial Drive Composite Edge Glazed Fiberglass Double Door Doors Assemblies Edgerton, erton OH 43517 w/ or w/out Sidelites Phone 419.298.1740 Inswing/Outswing "Impact' Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. for Therma Tru Corporation based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 7th Edition (2020) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-20468.9 require further engineering analysis by a licensed engineer or registered architect. 6. Fiber -Classic & Smooth -Star Door and Sidelite panels require the use of "J" part numbers and must be stained or painted within six months of installation 7. See drawing FL-20468.9 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 06-0718-1 ASTM E330-02, E1886-02, E1996-02 Testing Evaluation Lab.,lnc. V.K. Wright TEL 01460274 ASTM E1886-05, E1996-05 Testing Evaluation Lab.,lnc. V.K. Wright ASTM E330-02, E331-00 TEL 01460130 ASTM E1886-02, E1996-02 Testing Evaluation Lab.,lnc. V.K. Wright ASTM E330-02, E331-00 TEL 01461612 ASTM E1886-05, E1996-09 Testing Evaluation Lab.,lnc. V.K. Wright ASTM E330-02, E331-00 2. Miami Dade NOA Materials Testing 19-0305.02 Butacite° PVB Interlayer (Kuraray) 17-0712.05 Saflex® PVB Interlayer (Eastman Chemical Company) 3. Drawing No. Prepared by No. FL-20468.9 RW Building Consultants, Inc. (#9813) 4. Calculations Prepared by Anchoring RW Building Consultants, Inc. (#9813) 5. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute, certifying that Therma Tru Corporation is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. Sheet 1 of 1 0 ,%0111 %1 oo Signed & Sealed by %% �• SC��,Qr� ®©G Lyndon F. Schmidt, P.E. C' `s®�` igned & Sealed by • •^ NO 43409 `o..,,tyndon F. Schmidt, P.E. a K STATE OF a pt 0 Lyndon F. Schmidt, P.E. T �,� ^`;•,� fJ , 15�,. C', FL PE No. 43409 `'s� • • °"'r.� .�®`' 7/14/2020