Loading...
HomeMy WebLinkAboutOwens Corning 2020Business& Professional Regulation BCIS Home I Log In I User Registration ! not Topics Submit $urcharge Scats & Facts Puhlicaticns Contact Us BCIS Site Map Links Seism' Product Approval -: USER: Public User Pmduet Anpmval Menu > Prod-t or Application Search > ApplicaYOC Lisr > Application Detail + • FL # FL10674-R15 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greo.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel.sa ncrant@owe nscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Complfance Method Evaluation Report From a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity PRf Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 01/01/2099 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL10674 R15 COI 2019 01 COI NIEMINEN.odf Standard ASTM D1970 ASTM D3161 ASTM D3462 ASTM D7158 Year 2015 2016 2010 2011 Product Approval Method Method 1 option D Date Submitted 08/15/2019 Date Validated 08/15/2019 Date Pending FBC Approval 08121/2019 Date Approved 10/15/2019 Summary of Products r" FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab, 4-tabr 5-tab, laminated, starter and hip & ridge Shingles and Starters shingles Limits of Use Instaliation Instructions Approved for use in HVH2: No FL10C)74 R15 11 2019 08 FINAL ER a ASPHALT Approved for use outside HVH2: Yes SHINGLES Ft10674-R15.pdf Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE - 59166 Design Pressure; N/A Created by Independent Third Party: Yes Other. Refer to ER, Section 5. Evaluation Reports FL10674 R15 AE 2019 08 FINAL FR OC ASPHALT_ SHINGLES FL10674-R15.pdf Created by Independent Third Party: Yes ONL Contact ifs :: 2601 Olair Stone Road, Tallahassee rL 32399 Phone: 850-487-1824 The State of Florida is an AA/FEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455,275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.5- must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. Nowever email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine tf you are a licensee under Chapter 455, F.S., please click here . p product Approval Accepts: '"" F-1 94 Z- Credit Card Safe ENGINEER EVALUATE TEST NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 CONSULT CERTIFY Owens Corning Evaluation Report 037940.02.12-R10 One Owens Corning Parkway FL10674-R15 Toledo, OH 43659 Date of Issuance: 02/06/2012 (740) 404-7829 Revision 10: 08/15/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P,E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6Hh Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen, P.E. r _ _ The facsimile seal appearing was authorized by Robert �,p fin.`{_ _ �'•,fii`u! Nieminen, P.E. on 08/1512019. This does not serve as an Florida Registration No. 59166, Florida DCAANE1983 electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOletc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO Ietc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued_ 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in anyway, the designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02018, NEW ETC, LLC ONEMOJetc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 61' Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1S07.2.4, R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, 11905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-112453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 478612GS32 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various PRI (QUA9110) Quality Control Service Confirmation 04/05/2020 4.1 ACCESSORY STARTERS: 4.1.1 Starter Strip Shingle, Starter Strip Plus and SR5 TopShield Starter are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 Starter Shingle Roll is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 7.2-inch wide x 33-ft 4-inch long roll, for use with asphalt shingles. Meets ASTM D1970. 4.2 ASPHALT SHINGLES: 4.2.1 Classic' and Supreme' are fiberglass reinforced, 3-tab asphalt roof shingles. Meets ASTM D3462. 4.2.2 Berkshire' are fiberglass reinforced, 4-tab asphalt roof shingles. Meets ASTM D3462. 4.2.3 Duration', TruDefinition' Duration', Duration° Premium Cool, TruDefinition' Duration" Designer Color Collection, TruDefinition' Oakridge®, Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. Meets ASTM D3462. 4.3 Hip & RIDGE SHINGLES: 4.3.1 Berkshire' Hip & Ridge Shingles with Sealant, DuraRidgeO Hip & Ridge Shingles with Sealant, ProEdgeO Nip & Ridge Shingles and WeatherGuard' HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. Meets ASTM D3462. NEMO ETC, LLC Evaluation Report 037440.02.12-R10 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R1S Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 2 of 10 OMEMO j etc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVH2 jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating acceptable use in all wind zones UP to Vasa = 150 mph (V It = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.2 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating acceptable use in all wind zones up to Vasd = 150 mph (Valt = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5- Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORY STARTERS: 6.21 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions, using minimum five (5) nails per strip. Felt undedayment ----Oast Saltadhe d _ " WeatherLxk` . '� � wldasiagmant Qnp— llnp edge edge _ `Nit, l—tad Z"-3" Irom eava Instaifirst Sa3f-seaknp adhesive Sta,tw Strip _ _ . j psiti—d along we shingle with V rampved Smnar Strip shingle overhangs eaves and rakes'.-."-;:" Fdl aW&b raun D SW orb— orp.gaa kaand r-s•tnm.we Wth6e,—.dr5'bp Sfane+9bip Pkre everhanesnrn Wrak. lr;" V{' Figure 1: Minimum Nailing, Starter Strip Figure 2: Minimum Nailing, Starter Strip Plus NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization #32455 61H EDITION Q017i FBC NON-HVHZ EVALUATION FL10674-R1$ Owens Corning Asphalt Roof Shingles Revision 10: 09/15/2019 Page 3 of 10 ONEMOjetc. 6.2.2 installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. Drip edge Deck Self-sealing adhesive positioned along eaves Figure I Starter Shingle Roll Underlayment edge Starter Shingle Roll adhered directly to underlayment and primed drip edge 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire' shingles require minimum five (5) nails per shingle. ➢ WeatherGuarde HP shingles require minimum six (6) nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Classic® & Supreme: Normal Mansard or Area pare Wind Areas High Wind desvanes y Area para visntos normafes Areas vientos ruertes t• tt^ (A) it• ' J 5"Exposure EAposicion r' 2" o. Figure 4. Minimum Nailing, Classic & Supreme (Standard Size) Normal Mansard or Area pare Wind Areas High Wind des"nes it Area pare vientos normefes Areas viarrtos fuartes 5 518" Exposure Exposicidn Figure 5: Minimum Nailing, Classic & Supreme (Metric Size) NEMO ETC, LLC Evaluation Report 097940.02.12-R10 Certificate of Authorization#32455 eH EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1115 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 4of10 6.3.1.2 Berkshire®: Figure 6: 5-Nail Pattern, Berkshire ONEMOjetc. Figure 7: 6-Nail Pattern, Berkshire Figure 8: Mansard or Steep Slope Pattern, Berkshire MEMO ETC, LLC Evaluation Report 037940.02.12-R1O Certificate of Authorization #32455 6"' EDITION (2017) FSC NON-HVHZ EVALUATION FL10674-RIS Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 5 of 10 ONEMOjetc. 6.3.1.3 Duration", TruEDefinition® Duration, Duration" Premium Cool & TruDefinition" Duration" Designer Color Collection: 4-Nail Fastening Pattern SursRaiR fastening area width Nail, Typical 6.118" s.5ra" eMpozue Figure 9: Standard 4-Nail Pattern, Duration 6-Nall Fastening Pattern SureNaft tastening mw width Nail, Typical &4J8" 5-5i8" Figure 10: 6-Nail Pattern, Duration Figure 11. Mansard or Steep Slope Pattern, Duration NEMO ETC, 11C Fvaluation Report 037940.42.12-R10 CertifieoteafAuthorization#32455 6r" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10: 09/15/2019 Page 6 of 10 6.3.1.4 Tru Defin ition* OakridgeO, Oakridge®: 4 Nail Petarn i:sguma con 4 claws 55/8' Exposure 06 E'xposicdondo5518pulg. Claws #ONEMOjetc. 5 5/g" Exposure f j Ex0i? de posic6 5/8 ping. Figure 12: Standard 4-Nail Pattern, Oakridge 6 Nail Pattorn Fsquaw con 6 clavas €E_ t2` i2" l � l 55f8"Ex Exposure Nails 55f6"Ex P� Claws P°sure Fxposdd6n de 5 5/8 pudg. Fxposia6n da 5 5/8pudg. Figure 13: 6-Nail Pattern, Oakridge Fastening for Slopes Greater Than 21:12 Sur.N.HO raMo.ing area width NO Typical 1^ 12^ R cnn*rt.�.i.yZ'—...-� mi�iw�=wri •rMe.a�wrenG fu�4z- • B•'l16" 9.518" 72" Four 1" Spols or Asphalt Runfing Cement Figure 14: Mansard or Steep -Slope Pattern, Oakridge NEMO ETC, LLC Evaluation Report 037940.DZ.12-R10 Certificate ofAuthorkation #32455 fir" EDITION (2017) F8C NON-HVHZ EVALUATION F1.10674-1115 Owens Corning Asphalt Roof Shingles Revision 10. 08/15/2019 Page 7 of 10 6.3.1.5 WeatherGuard® HP: i �3�„5�C rrj �^yV A� �i s 78 puiL} aa�l 5 5N �.. Figure 15: 6-Nail Pattern, WeatherGuard HP 8 Nan Pattern EsIwL €m Cop 5 clavos Nail 6 TT from tramm M stlrigle £lave a 6 1 8 ping. de a 5 7 $' E[pmae 5 Fasteners We inleriflt Cie Is Ila fxpe-%cim de 5 5"s pig. 6 si�ataeores Four l ` Spots df Asphat %of Cerner.: Cualro punin de ceo nfo de tedv de asfdto dr f pviyoda Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP ONEMOjetc- 6.4 HIP & RIDGE SHINGLES: 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. ➢ Berkshire Hip and Ridge Shingles with Sealant and DuraRidge® Hip & Ridge Shingles with Sealant require minimum two (2) nails per shingle. ➢ WeatherGuard° HP Hip and Ridge Shingles and ProEdge® Hip & Ridge Shingles require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. NEMO ETC, LLC Evaluation Report 031940.02.12-1110 Certificate ofAuthorizotion #32455 E�" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10.08/15/2019 Page 8 of 10 ONEMOjetc. 6.4.1.1 BerkshireO Hip & Ridge with Sealant and DuraRidge* Hip & Ridge Shingles with Sealant: Fig. A Prevailing Wind Direction -4— Direcci6n del viento prodominante 4 Nails p Clavos q 1 I k I I R I I R I I I I I I I I I I �Fxpowre� h�aPla 4 Figure 17: Isometric View, Berkshire and DuraRidge 6.4.1.2 WeatherGuard" HP Hip & Ridge Shingles: Fig. A � 4 PM-Alingwincl �——Dlreclion AA� Nal1s � 4 4 A I I P A I A i j I Exposure Figure 19: Isometric View, WeatherGuard HP Hip & Ridge Fig. B Top View Vista superior It j. Nail 2W' Clavo 0vxns Coming StreNaB' • I wig 4) Ulf 1 12" Figure 18. Plan View, Berkshire and DuraRidge Fig. C Hip & Ridge Shingle Fastening TpPvkw w�n--- -- Hafts N81L t�� t„ � ErpomlM 17 Figure 20: Plan View, WeatherGuard HP Hip & Ridge MEMO ETC, LLC Evaluation Report 037940.02.12-R10 Certificate of Authorizotion#32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof shingles Revision 10. 08/15/2019 Page 9 of 10 6.4.1.3 ProEdge® Hip & Ridge Shingles: Prevailing Wind Diir•etien suhnt strip F#sten 71h' efter sta:tsor RWOW ewith Roof CenwwA Figure 21. Isometric View, ProEdge ONEMOjetc. Standard Fastening Pattrrn t2` � _ SEiisM .......... Y 3 Figure 22: Plan View, ProEdge 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. REQUIREMENTS*8. BUILDING PERMIT As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. 10. QUALriy ASSuRANcE ENTITY: PRI Construction Materials Technologies, LLC—QUA9110; 813' 621-5777; bwilson@pricmt.com - END OF EVALUATION REPORT - NEMO ETC, LLC CertifxateofAathcrizatian #32455 6"' EDITION (2017) FBC NON-HVN2 EVALUATION Owens Corning Asphalt Roof Shingles Evaluation Report 037940.02.12-RID FL20674-R15 Revision 10: 08/15/2019 Page 10 of 10