HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTSFlorida Building Code Online Page 1 of 2
Professionalusiness 1
Iel ,
BaS Nome Lpg In User Registration
Hot Toples Submit Surcharge Stats h Farts
Publications Fat State $CIS Site Map
Links Search
dbOr
PrvduCt Approval
USEll- Putlic User
ao
Product Aonrwal Menu > Product or Aoollcatlnn
saaLLt > Aocl raiton L ., a Appllcatiun Detail
FL
FL18686-R3
e US }QA-
A All
Application Type
Revision
Code Version
2017
Application Status
Approved
*Approved by DBPR.
Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product ManUfactUrer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Small
Category
Subcategory
Compliance Method
Evaluation Entity
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
0
GAF
1 Campus Drive
Parisppany, N] 07054
(800) 766-3411
mstieh@gaf,com
Michael Stieh
mstiehOgaf.com
Michael Stieh
1 Campus Drive
Parsippany, N] 07054
(973) 628-3000
mstlehCMgaf.com
Richard Weiman
1 Campus Drive
Parsippany, N3 07054
(973) U72-4421
RWeiman@gaf.com
Roofing
Underlayments
Evaluation Report from a Product Evaluation Entity
Miami -Dade BCCO - EVIL
Mlami-Dade BCCO - CER
02/22/2023
Miaml-Dade BCCO - VAL
Standard
ASTM D226
Year
2009
http://www.floridabuildine.orglprlpr_app_dtl.aspx?param=wGEVXQwtDquIGtg5bCXRsc... 3/26/2018
Florida Building Code Online
Page 2 of 2
Product Approval Method Method 1 Option C
Data Submitted 02/26/2018
Data Validated 03/16/2018
Date Pending FBC Approval
Date Approved 03/26/2018
Summary of Products
I
FL X
Model, Number or Name
Description
18686.1
FeftBuster
High -Traction Synthetic Rooting Felt
Limits of use
Installation Instructions
Approved for use in HVHZ: Yes
FL18686 R3 11 18-0119.15.odf
Approved for use outside HVHZ: Yes
Verified By: Miami -Dade BCCO - EVIL
Impact Resistant: No
Created by Independent Third Party:
Design Pressure: N/A
Evaluation Reports
Other:
FL18686 R3 AE 18-0119.15.odf
Contra Ut :: 3601 Blair Slone 0.oaa. TalAbassee FL 33399 Phone, 850-UP-1924
The State of nond. is an WEED employer R ivaa Rrtemwrt : riclMl sea[em nt :'. ReNne statement
Under notl0e bw, email addresses are public records. If you do sup want your ewmall address released M response to a pudic -records rmiced, do not send
ekRrenic mad to this eMV. Instead, toms& the office by phone or by traditional mall. If you have any donations, please contact 850.481.1395. •Pursuant to
Section 455375(l), nonce Statutes, effective October 1, 2012, licences licensed under Chapter 455, F.S. must provide the Department With an email address IF
they have one. The !Tails pMMdM May be used for official communication With ale kin see. However email addresses are public record. If you do not Wish to
supply a personal address, please provide the Department with an email address which tan be made avallebk to the public. To determine If you are a licence under
Chapter 455, F.S., please dick b=.
Feaduet AJppraval Asilln a
�CV a Caeu
Credit Card
safe
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?pazam=wGEVXQwtDquIGtg5bCXRsc... 3/26/2018
MIAMMn�I�AM
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DMSION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) ww .miamidade.cov/economv
GAF
1 Campus Drive
Parsipanny, NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Leak Barriers and Roof Deck Protection
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NUA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA 16-1213.04 and consists of pages I through 10.
The submitted documentation was reviewed by Hamley Pacheco, P.E.
�1
NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 1 of 10
ROOFING COMPONENT APPROVAL
Cateeorv: Roofing
Sub -Category. Underlayment
Material: SBS/Polypropylene/Asphalt
PRODUCTS DESCRIPTION:
Test
Product
Product
Rimensions
Specification
Description
WeatherWatch' Mineral
36" x 50' rolls
ASTM D 1970
Granular surfaced modified, fiberglass reinforced,
Surfaced Leak Barrier
36" x 66.7' rolls
bituminous sheet material for use as a leak barrier
Manufacturing
underlayment in sloped roof assemblies.
Location #1, 9
Designed as an ice & rain shield.
StormGuard' Film
36" x 66.7' rolls
ASTM D 1970
Modified, fiberglass reinforced, bituminous sheet
Surfaced Leak Barrier
material for use as a high temperature leak barrier
Manufacturing
underlayment in sloped roof assemblies.
Location #1, 9
Designed as an ice & rain shield.
Libertyr"r SBS Self -
Adhering Base/Ply Sheet
Manufacturing
Location #1, 9
Deck -Armor" Premium
Breathable Roof Deck
Protection
Manufacturing
Location #2
Tiger Pawl Roof Deck
Protection
Manufacturing
Location #3, 5, 6
39?/#" x 66' rolls
ASTM D 1970
Self -adhering SBS roof membrane.
ASTM D4601
Type II
54" x 222' rolls
ASTM D 226
A UV -stabilized polypropylene breathable
48" x 100' rolls
Type II
underlayment. To be used for roof deck
protection as an underlayment in sloped roof
assemblies.
48" x 250' rolls
ASTM D 226
A UV -stabilized polypropylene non -breathable
48" x 100' rolls
Type II
underlayment. To be used for roof deck protection
as an underlayment in sloped roof assemblies.
OFeltBuster' High -Traction 49" x 250' rolls ASTM D 226 A UV -stabilized polypropylene non -breathable
Synthetic Roofing Felt Type I underlayment. To be used for roof deck protection
Manufacturing as an underlayment in sloped roof assemblies.
Location #7, 8
Shingle -Mate' Roof Deck 36" x 144' rolls ASTM D 226 Fibergass-reinforced asphalt felt underlayment. To
Protection Type I be used for roof deck protection as an
Manufacturing underlayment in sloped roof assemblies.
Location #4
NOA No.: 18-0119.15
MIAML0110E COUNTY Expiration Date: 02/22/23
• Approval Date: 02/22/18
Page 2 of 10
PRODUCTS DESCRIPTION:
Test
Product Dimensions Specification
Libertyrm SA Glass Cap 39-'/s" x 34' rolls ASTM D 1970
Sheet ASTM D 6163
Manufacturing ASTM D 7530
Location # 9
GAFGLAS® Ply 4
3937"
ASTM D2178
Manufacturing
(1 meter) Wide
Type IV
Location # 9, 10
GAFGLAS® FleaP1yFm 6
39.37"
ASTM D2178
Manufacturing
(1 meter) Wide
Type VI
Location # 9, 10
MANUFACTURING LOCATION:
1.Mt. Vernon, IN
2.North Bay, Ontario
3.Mission, British Columbia
4.Pryor, OK
5.Qingdao, China
6.Charleston, SC
7.Spartanburg, SC
8.Dadra, India
9.Savannah, GA
IO.Mobile, AL
Product
Description
Granular surfaced modified, fiberglass reinforced,
self -adhering SBS roof membrane.
Aspahalt impregnated glass felt with aspahlt
coating.
Aspahalt impregnated glass felt with aspahlt
coating.
NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date- 02/22/18
Page 3 of 10
EVIDENCE SUBMITTED:
Test Agency
Intertek Testing Services NA Ltd.
PRI Construction Materials
Technologies, LLC.
Trinity-ERD
Test Identifier
Test Name/Renort
Date
3077464-01
ASTM D 1970
08/23/06
3090131
Wind Uplift and Self Sealability
08/23/06
100258583COQ-OIOA
ASTM D 226 Type II
01/08/11
100673818COQ-003
ASTM D 226 Type II
06/13/13
10157289000Q-005
ASTM D 226 Type II
04/17/14
F8549.02-106-18
ASTM D 226 Type I
11/08/16
RGM-023-02-01
ASTM D 4798
05/16/07
GAF-112-02-01
ASTM D 226 Type II
03/15/06
GAF-238-02-01
ASTM D 1970
03/03/10
GAF-323-02-01
ASTM D 1970
11/30/11
GAF-324-02-01
ASTM D 1970
12/01/11
GAF-325-02-01
ASTM D 1970
12/01/11
GAF-326-02-01
ASTM D 1970
11/30/11
GAF-275-02-01
ASTM D 1970
i t/11/10
GAF-344-02-01
ASTM D 1970
04/23/12
GAF-339-02-01
ASTM D 226 Type I
03/14/12
ELK-311-02-01
ASTM D 1970
09/11/07
GAF-518-02-01
ASTM D 226 Type I
06/04/14
GAF-818-02-01
ASTM D 4533
12/06/17
GAF-829-02-01
ASTM D 226 Type II
01/15/18
GAF-314-02-01
ASTM D 2178
07/21/11
GAF-315-02-01
ASTM D 2178
07/21/11
GAF-SC13285.03.17-1
ASTM D 1970
03/08/17
GAF-SC13285.03.17-3
ASTM D 1970
03/01/17
GAF-SC13285.03.17-4
ASTM D 1970
03/01/17
GAF-SC13285.02.17-2
ASTM D 4601 Type II
02/08/17
GAF-SC9700.08-IS-RI
ASTM D 2178
09/09/15
GAF-SC12915.12.17-RI
ASTM D 1970
12/11/17
GAF-SC12915.12.17-RI
ASTM D 6163
12/11/17
GAF-SC12915.12.17-RI
ASTM D 7530
12/11/17
NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 4 of 10
APPROVED ASSEMBLIES:
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E (1): Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle -Mateo Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck-Armorr` Premium Breathable Roof Deck Protection, FeltBuster®
High -Traction Synthetic Roofing Felt, or Tiger PawTM' Roof Deck Protection with a minimum 4"
side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6"
o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of WeatherWatch' Mineral Surfaced Leak Barrier, StormGuarda Film
Surfaced Leak Barrier, LibertyTM SA Glass Cap Sheet, or Libertyrm SBS Self -Adhering
Base/Ply Sheet membrane with a minimum 3" side lap and 6" end lap. Place the first course of
membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the
release membrane as the membrane is applied. Vertical strapping of the roof with
WeatherWatch"® Mineral Surfaced Leak Barrier, or StormGuard® Film Surfaced Leak Barrier is
acceptable.
Surfacing: Approved Roofing Assembly.
NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 5 of 10
Deck Type 1: Wood, non -insulated
Deck Description: "/32" or greater plywood or wood plank
System E(2): Membrane mechanically fastened to deck.
Separator Sheet: One or more plies of GAFGLAS® Ply 4, GAFGLAS® FlexPlyTM 6, Shingle -Mate® Roof Deck
Protection, Deck -Armor' Premium Breathable Roof Deck Protection, FeltBusterx High -
Traction Synthetic Roofing Felt, or Tiger Paw' ' Roof Deck Protection loose laid.
Membrane: One or more plies of WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard't' Film
Surfaced Leak Barrier, LibertyT"' SA Glass Cap Sheet, or LibertyT"' SBS Self -Adhering
Base/Ply Sheet membrane mechanically fastened with a minimum 3" side lap and a 6" end lap to
deck through the separator sheet with approved nails and tin caps 6" o.c. at the laps and two
staggered rows 12" o.c. in the field of the roll.
Surfacing: Approved Roofing Assembly.
NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 6 of 10
Deck Type 1: Wood, non -insulated
Deck Description: "/32" or greater plywood or wood plank
System E (3): Anchor sheet mechanically fastened to deck, membrane adhered.
Secondary Water Install a minimum 4" wide WeatherWatch"" Mineral Surfaced Leak Barrier,, LibertyTm SBS
Barrier: Self -Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, or StormGuard'' Film Surfaced
(Optional) Leak Barrier membrane over the joints of the plywood roof deck prior to installation of the base
sheet. Do not overlap end or side joints. All side and end laps should be butted firmly side by
side, flush with each other but not overlapped. Do not leave the WeatherWatch' Mineral
Surfaced Leak Barrier, or StormGuard' Film Surfaced Leak Barrier membrane exposed for more
than 30 days without a roof deck protection underlayment protecting the secondary water barrier.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle -Mate® Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck -Armor'' Premium Breathable Roof Deck Protection,
FeltBuster® High -Traction Synthetic Roofing Felt, or Tiger Paw' Roof Deck Protection with a
minimum 4" side lap and a 6" end lap mechanically fastened to the deck with approved nails and
tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fasteners.
Surfacing: Approved Roofing Assembly.
NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 7 of 10
Deck Type 1: Wood, non -insulated
Deck Description: 19/32 " or greater plywood or wood plank
System E (4): Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle -Mate® Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck -Armor' Premium Breathable Roof Deck Protection,
FeltBuster® High -Traction Synthetic Roofing Felt, or Tiger PawTM Roof Deck Protection with a
minimum 4" side lap and a 6" end lap mechanically fastened to the deck with approved nails and
tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of StormGuard" Film Surfaced Leak Barrier membrane with a minimum 4"
side lap and 6' end lap. Place the first course of membrane parallel to the eave, rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied.
Surfacing: Approved for Metal roofing, Slate, and Asphalt Shingle assemblies.
NOA No.: 18-0119.15
IMCOUNTY Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 8 of 10
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. WeatherWatch' Mineral Surfaced Leak Barrier, StormGuard O Film Surfaced Leak Barrier, LibertyT SBS Self -
Adhering Base/Ply Sheet, LibertyT"t SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck-AnnorT'
Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger Paw'
Roof Deck Protection shall not be used as roof tile underlayment.
3. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. WeatherWatch° Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak
Barrier, LibertyT SBS Self -Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle -Mate® Roof Deck
Protection, Deck -Armor' Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic
Roofing Felt, and Tiger Paw' Roof Deck Protection shall be installed in strict compliance with applicable
Building Code.
4. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorT'
Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger Paw'
Roof Deck Protection membranes shall be applied to a smooth, clean and dry surface with deck free of
irregularities.
5. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle -Mate' Roof Deck Protection, Deck -Armor"
Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger Paw'
Roof Deck Protection membranes shall not be applied over an existing roof membrane.
6. WeatherWatch' Mineral Surfaced Leak Barrier, StormGuar& Film Surfaced Leak Barrier, LibertyT SBS Self -
Adhering Base/Ply Sheet, LibertyTM SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck -Armor'
Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger Paw'
Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application.
7. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -
Adhering Base/Ply Sheet, LibertyT SA Glass Cap Sheet, Shingle -Mate' Roof Deck Protection, Deck-ArmorTM
Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger Paw,
Roof Deck Protection may be used with any approved roof covering Notice of Acceptance listing WeatherWatch'
Mineral Surfaced Leak Barrier, StormGuard' Film Surfaced Leak Barrier, LibertyT SBS Self -Adhering Base/Ply
Sheet, LibertyT SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck -Armor' Premium Breathable
Roof Deck Protection, FeltBuster' High -Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection
as a component part of an assembly in the Notice of Acceptance. If WeatherWatch'* Mineral Surfaced Leak
Barrier, StormGuard' Film Surfaced Leak Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, LibertyTM SA
Glass Cap Sheet, Shingle -Mateo Roof Deck Protection, Deck -Armor" Premium Breathable Roof Deck Protection,
FeltBuster® High -Traction Synthetic Roofing Felt and Tiger Paw' Roof Deck Protection are not listed; a request
may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department
for approval provided that appropriate documentation is provided to detail compatibility of the products, wind
uplift resistance, and fire testing results.
8. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application. install when temperatures are 45' F and
rising.
9. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions.
NOA No.: 18-0119.15
Expiration Date: 02/22/23
Approval Date: 02/22/18
Page 9 of 10
LIMITATIONS:
10. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
13. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control
Approved" or the Miami -Dade County Product Control Seal as shown below.
END OF THIS ACCEPTANCE
NOA No.: 18-0119.15
E COtMTM Expiration Date: 02/22/23
Approval Date: 02/22/18