Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CA1 - ARCHITECTURAL CANOPY PLAN, ELEVATIONS, AND DETAILS
CA1 17 CA227 1 A B 2 3 4 CA1 25 CA1 23 C D WAWASIDEMPDISLANDEXTENTSOFCANOPY ABOVE (TYP.) EXTENT OF CONCRETE SLAB (TYP.) 3/4" COLD WATER LINE. RUN UNDERGROUND TO WATER SERVICE ROOM AT BUILDING. USE BLACK POLY PEX PIPE. SEE SHEET P2 FOR CONTINUATION. WALL HYDRANT. (WCH) SEE HYDRANT DETAIL, THIS SHEET, AND P5 FOR SPECIFICATION. RUN PIPING IN COLUMN SURROUND. PER CIVIL (EXTENTS OF CONCRETE SLAB) PER CIVIL (EXTENTS OF CONCRETE SLAB)14' - 0"34' - 0"34' - 0"34' - 0" 14' - 0"( TYP.) 2' - 0"( TYP.) 2' - 0"6' - 8"12' - 0" 18' - 0"12' - 0"6' - 4" FEC FECFEC FEC FEC FEC FEC FEC RECYCLE UNIT (TYP.) TRASH UNIT ( TYP.)TRASH UNIT (TYP.)RECYCLE UNIT ( TYP.)SPILL KIT VALET SPILL KIT VALET MPD ISLANDMPD ISLANDMPD ISLANDMPD ISLANDMPD ISLANDMPD ISLANDMPD ISLANDSTREET SIDE BOLLARDS ( TYP.)BOLLARDS ( TYP.) 55' - 0" (EXTENTS OF CANOPY TRIM)130' - 0" ( EXTENTS OF CANOPY TRIM)DOWNSPOUT IN COLUMN (BY CANOPY MFR., TYP. EACH COLUMN @ LOW SIDE OF ROOF)1 A B MPD ISLANDGAS MPDBOLLARD (TYP.)C D RIVERSIDE STEEL INC." STAINLESS STL. "ISLAND" STYLE FORM. 13" CURB, 6" OR LESS ABOVE CONCRETE SURFACE TO COMPLY WITH ACCESSIBILITY REQUIREMENTS.GAS MPDBOLLARD (TYP.)DOWNSPOUT IN COLUMN (BY CANOPY MANUFACTURER TYP. EACH COLUMN @ LOW SIDE OF ROOF) SEMI- RECESSED FIRE EXTINGUISHER CABINET F. E.C.).SEMI-RECESSED FIRE EXTINGUISHER CABINET F.E. C.). RIVERSIDE STEEL INC." STAINLESS STL. " ISLAND" STYLE FORM. 13" CURB, 6" OR LESS ABOVE CONCRETE SURFACE TO COMPLY WITH ACCESSIBILITY REQUIREMENTS.SPILL KIT VALET, LOCATIONS AS INDICATED ON CANOPY FLOOR PLAN MPD ISLAND(TYPICAL) 3' - 0"12' - 0"18' - 0" 12' - 0"RECYCLE UNIT (TYP.)TRASH UNIT (TYP.) 12 CA1 EQ EQ EQ EQMIN. CLR. 40" MIN. CLR. 40" 5 CA2 CONNECT DOWNSPOUT TO SITE STORM DRAINAGE SYSTEM. SEE CIVIL.3' - 8"3' - 6"5' - 0"3' - 6"4' - 10"EQEQ4' - 10"3' - 6"5' - 0" 3' - 6"3' - 8"GRADE 0' - 0"1 2 3 4 B.O. TRUSS 14' - 0"MPD ISLAND MPD ISLANDMPD ISLAND 18 CA2 MPD ISLAND T. O. CANOPY 25' - 2"B.O. CANOPY 14' -9 3/4"GRADE 0' -0" 1234 B.O. TRUSS 14' -0" PRE-ENGINEERED METAL PANEL DECKING COLOR: TO MATCH BUILDING METAL ROOF STEEL FRAMING COLOR: FACTORY PAINTED WHITE MPD ISLANDMPD ISLANDMPD ISLAND 18 CA2 MPD ISLAND SIGN BY WAWA, SURFACE MOUNTED SIGN BY WAWA, SURFACE MOUNTED EMBOSSED TRIM COLOR: TO MATCH BUILDING METAL ROOF T. O. CANOPY 25' -2" B.O. CANOPY 14' -9 3/ 4"NOTE: SIGNAGE IS SHOWN FOR REFERENCE ONLY SEPARATE PERMIT REQUIRED COLUMN COLOR: FACTORY PAINTED WHITE GALVANIZED METAL COLUMN SURROUND BY CANOPY MFR.SCRATCH COAT STEEL COLUMN ADHERED MANUFACTURED STONE VENEER TO MATCH BUILDING INSTALLED PER MFR.' S RECOMMENDATIONS MORTAR BED SIGNAGE DECALS ADHERED TO ALUM. PLATE B.O. SIGNAGE 80" A. F.F. (MIN.)SECURE SPACER AND SCREW TO MTL. COLUMN SURROUND (TYP.) 2.5# SELF-FURRING GALVANIZED METAL LATH GALVANIZED MTL. COLUMN SURROUND BY CANOPY MFR.SCRATCH COAT STEEL COLUMN ADHERED MANUFACTURED STONE VENEER TO MATCH BUILDING INSTALLED PER MFR.'S RECOMMENDATIONS MORTAR BED CONTINUOUS SEALANT WALL HYDRANT (NO COVER ON BOX WITH KEYED OPERATION AND HOSE HOOK).2.5# SELF- FURRING GALVANIZED METAL LATH GRADE 0' -0"5 1/2" X 4" MTL. TRIM, PREFINISHED WHITE BY CANOPY MFR. 16" X 16" GALVANIZED MTL. COLUMN SURROUND BY CANOPY MAUFACTURER 1/4" BACKER ROD AND CONTINUOUS BEAD OF PETROLEUM RESISTANT CAULK. ACCESS PANEL 2. 5# SELF- FURRING GALVANIZED METAL LATH SCRATCH COAT MORTAR BED 12x12 COL PER STRUCTURAL ADHERED MANUFACTURED STONE VENEER TO MATCH BUILDING INSTALLED PER MFR.'S RECOMMENDATIONS PVC DOWNSPOUT (AT LOW SIDE OF ROOF ONLY), BY CANOPY MFR.CA1 28 CA1 30 FIRE EXTINGUSHER FIRE EXTINGUSHER CABINET CA1 24 FIRE EXTINGUISHER SIGN NEOPRENE WASHER, TYP.ADHERED MANUFACTURED STONE VENEER TO MATCH BUILDING. INSTALLED PER MFR.'S RECOMMENDATIONS. STL COLUMN FIRE EXTINGUISHER CABINET GALVANIZED METAL COLUMN SURROUND BY CANOPY MFR. FIELD CUT AT CABINET)2"X2" STEEL ANGLE 2"X2" STEEL ANGLE NEOPRENE WASHER, TYP. 12 TEK SCREWS (TYP.)12 TEK SCREWS (TYP.)1/ 4" BACKER ROD AND CONTINUOUS BEAD OF PETROLEUM RESISTANT CAULK. (TYP.)48" A.F. F.T.O. CABINET 2' - 6 3/8" GRADE 0' -0" ADHERED MANUFACTURED STONE VENEER LATICRETE AIR & WATER BARRIER 1/ 2" MIN. LATICRETE MASONRY VENEER MORTAR PVC WEEP SCREED, COLOR: GREY CONT. MTL FLASHING W/ HEMMED EDGES (HOLD FROM FRONT OF STONE 1/4" MIN.) BACKER ROD AND PETROLEUM RESISTANT SEALANT 3.4# SELF- FURRING GALVANIZED METAL LATH AND LATICRETE PREMIUM MORTAR BED GALVANIZED METAL COLUMN SURROUND 1/4" BACKERROD AND CONTINUOUS BEAD OF PETROLEUM RESISTANT CAULK. GALVANIZEDMETAL COLUMN SURROUND BY CANOPY MFR.2"X2" STEELANGLE CONT. @ PERIMETER STEEL COLUMN 10" X 10" STAINLESS STEELFLUSH ACCESS PANEL BY GC MFR: J. L. INDUSTRIES MODEL : TM- 1010 TMS HAND HOLE IN STEEL COLUMN AND GALVANIZEDMETAL COLUMN SURROUND. SIZE AND LOCATION PER STRUCTURAL 12 TEKSCREWS W/ NEOPRENE WASHER ( TYP.)10"10"SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDDRAWNDATEPROJECT NO.COPYRIGHT © - All reports, plans, specifications, computer files, field data, notes and otherdocuments are instruments of service prepared by: Cuhaci & Peterson, (C & P) as instruments of service remain the property of C & P. C & P shall retain all common law, statutory and other reserved rights, including the copyright thereto. Any use or reproduction of this document without written permission from C & P is a violation of Federal copyright laws.4/17/2020 2:36:34 PMCA1218071904-17-2020S.G.A. D.M.ARCHITECTURAL CANOPY PLAN, ELEVATIONS, AND DETAILSORANGE AVE. & KINGS HWY, FT. PIERCE, FLWAWA260 WEST BALTIMORE PIKEWAWA, PENNSYLVANIA 19063WAWA STACKED 8 GAS CANOPY 2019.01 STORE #5380-ORN04/17/2020 1/8" = 1'-0"CA1 11 CANOPY FLOOR PLAN 1/4" = 1'- 0" CA1 25 GAS ISLAND DETAIL 1/8" = 1'-0"CA1 17 CANOPY FRONT ELEVATION ( WAWA SIDE)1/8" = 1'-0"CA1 23 CANOPY REAR ELEVATION (STREET SIDE)3" = 1'-0"CA1 29 FIRE EXTINGUISHER SIGN MOUNTING DETAIL 3" = 1'- 0"CA1 27 WALL HYDRANT DETAIL 1 1/2" = 1'-0"CA1 12 COLUMN DETAIL 3" = 1'-0"CA1 24 FIRE EXTINGUISHER CABINET DETAIL 3" = 1'-0"CA1 30 COLUMN BASE DETAIL 3" = 1'-0"CA1 28 ACCESS PANEL DETAIL GENERAL NOTES:1. ALL WORK SHALL COMPLY WITH THE FLORIDA BUILDING CODE 6TH EDITION (2017), THE FLORIDA FIRE PROTECTION CODE 6TH EDITION (2017), 2012 NFPA 30A FOR MOTOR FUEL DISPENSING FACILITIES AND REPAIR GARAGES, AND 2013 NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS. SEE COVER SHEET FOR DETAILED CODE INFORMATION.2. FUEL DISPENSING SYSTEMS (NFPA 30A:6.7 EMERGENCY ELECTRICAL DISCONNECTS) SHALL BE PROVIDED WITH ONE OR MORE CLEARLY IDENTIFIED EMERGENCY SHUT OFF DEVICES OR ELECTRICAL DISCONNECTS. SUCH DEVICES OR DISCONNECTS SHALL BE INSTALLED IN APPROVED LOCATIONS BUT NOT LESS THAN 20 FEET OR MORE THAN 100 FEET FROM THE FUEL DISPENSING DEVICES THAT THEY SERVE.3. FIRE EXTINGUISHER CABINETS (F.E.C.) SHALL BE STAINLESS STEEL SURFACE MOUNTED AS MANUFACTURED BY J.L. INDUSTRIES, COSMOPOLITAN SERIES, MODEL #2033, WITH FULL CLEAR ACRYLIC GLAZING ON DOOR. FIRE EXTINGUISHER CABINETS ARE SUPPLIED BY WAWA AND INSTALLED BY GENERAL CONTRACTOR. ONE PER MPD ISLAND. SEE DETAILS THIS SHEET FOR REQUIRED MOUNTING HEGHTS.4. FIRE EXTINGUISHERS SHALL HAVE A MINIMUM UL RATING OF 4A:60-B:C (HIGH FLOW). FIRE EXTINGUISHERS TO COMPLY WITH 2012 NFPA 30A AND MEET OR EXCEED 2013 NFPA 10 CLASS B SPECIAL HAZARD FIRE PROTECTION RECOMMENDATIONS. FIRE EXTINGUISHERS ARE SUPPLIED BY WAWA AND INSTALLED BY PETROLEUM CONTRACTOR. ONE PER MPD ISLAND.5. FIRE EXTINGUISHER SIGNS PROVIDED AND INSTALLED BY WAWA. SEE DETAIL THIS SHEET FOR REQUIRED MOUNTING HEIGHT.6. WARNING SIGNS SHALL BE PROVIDED BY WAWA AND INSTALLED BY THE PETROLEUM CONTRACTOR AT EACH MPD ISLAND. WARNING SIGNS (2017 FFPC 1:42.7.5.3 AND 2012 NFPA 30A 9. 2.5.4) SHALL INCLUDE BUT NOT BE LIMITED TO:a. NO SMOKING.b. STOP ENGINE.c. UNLAWFUL TO DISPENSE GASOLINE INTO UNAPPROVED CONTAINERS.7. EMERGENCY INSTRUCTIONS (2017 FFPC 1: 42.7.5.3 AND 2012 NFPA 30A:9.5.3) SHALL BE PROVIDED BY WAWA AND INSTALLED BY THE PETROLEUM CONTRACTOR, BE CONSPICUOUSLY POSTED IN THE DISPENSER AREA, AND SHALL INCORPORATE THE FOLLOWING OR EQUIVALENT WORDING: a. EMERGENCY INSTRUCTIONS - IN CASE OF FIRE OR SPILL:b. USE EMERGENCY STOP BUTTON c. REPORT ACCIDENT BY CALLING (SPECIFY LOCAL FIRE NUMBER). REPORT LOCATION. 8. LOCATION OF TRASH UNITS AND RECYCLE