Loading...
HomeMy WebLinkAboutCE1 - ELECTRICAL CANOPY PLANS, DETAILS, SCHEDULESA B C D FUEL DISPENSER FUEL DISPENSER LIGHTING FIXTURE LIGHTING FIXTURE LIGHTING FIXTURE WAWA STORE SIDE 1 A B 2 3 4 C D FD FD FD FD FD FUEL DISPENSER TYPICAL) COLUMN D" (TYP.) COLUMN C" (TYP.) COLUMN B" (TYP.) COLUMN A" (TYP.) COLUMN D" (TYP.) COLUMN C" (TYP.) COLUMN B" (TYP.) COLUMN A" (TYP.)RPD-9:11, SEE DETAIL 3 THIS SHEET 2#10,#10G FUEL DISPENSER TYPICAL) RPD-17:19, SEE DETAIL 3 THIS SHEET 2#10,#10G FUEL DISPENSER TYPICAL) RPD-21:23, SEE DETAIL 3 THIS SHEET 2#10,#10G RPD-13:15, SEE DETAIL 3 THIS SHEET 2#10,#10G WAWA STORE SIDE RPD-22:24, SEE DETAIL 3 THIS SHEET 2#10,#10G RPD-18:20, SEE DETAIL 3 THIS SHEET 2#10,#10G RPD-14:16, SEE DETAIL 3 THIS SHEET 2#10,#10G RPD-10:12, SEE DETAIL 3 THIS SHEET 2#10,#10G LPA-27:29, SEE DETAIL 3 THIS SHEET 2#10,#10G LPA-23:25, SEE DETAIL 3 THIS SHEET 2#10,#10G LPA-19:21, SEE DETAIL 3 THIS SHEET 2#10,#10G LPA-22:24, SEE DETAIL 3 THIS SHEET 2#10,#10G LED LIGHT BARS IN FIXTURES TO BE PERPENDICULAR TO STORE, TYP. FD FD FD FD FD FD FD FD FD FDFD FD FDFD FD FDFD FDFDTYP. 4' - 3"TYP 6' - 6"TYP 6' - 6" SEE ELECTRICAL NOTE #9 TYP.4' - 3"TYP.9' - 0"GASOLINE CANOPY CONDUIT REQUIREMENTS:1) 3/ 4" GRC TO EACH DISPENSER FOR INTERCOM/MUSIC 1) 1" GRC TO EACH CANOPY COLUMN B FOR CANOPY LIGHTING.FUEL-TANK MONITOR)1 POWER, 1 DATA)1) 3/4" GRC TO EACH DISPENSER.2) 3/4" GRC TO EACH DISPENSER.EACH COLUMN FURTHEST FROM STORE AT FIRST ROW OF DISPENSERS)1) 1" GRC TO EACH CANOPY COLUMN C FOR SPARE CANOPY D" COLUMN C" CANOPY COLUMN CANOPY B" COLUMN A" CANOPY COLUMN FUEL DISPENSER LOCATION WAWA STORE SIDE FUEL DISPENSER LOCATION 3/4" GRC. FUEL- TANK MONITOR3/4" GRC. INTERCOM & MUSIC3/4" GRC. DISPENSER (DATA) 3/4" GRC. DISPENSER ( POWER)1" GRC SPARE (POWER)3/ 4" GRC. INTERCOM & MUSIC3/ 4" GRC. FUEL-TANK MONITOR3/4" GRC. DISPENSER ( POWER)3/4" GRC. DISPENSER (DATA) 1" GRC POWER (LIGHTS) STEEL COLUMN 1 1/ 4" HOLE IN COLUMN RE: STRUCTURAL CONDUIT CONNECTOR MIN. 5 THREADS EXPOSED CONDUIT (BY PETROLEUM CONTRACTOR) WHERE OCCURS)RE: DETAIL 3/CE1 THREADED CONNECTOR. 5 THREADS MIN. EXPOSED. RE: DETAIL 4/CE1 SEE STRUCTURAL FOR SIZE AND LOCATION OF HOLES GALVANIZED RIGID CONDUIT BY CANOPY FABRICATOR) SEE STRUCTURAL SHEETS FOR HAND HOLE SIZES AND LOCATIONS HAND HOLE FOR LIGHTING CONDUIT ON COLUMN B ONLY. SEE STRUCTURAL SHEETS FOR HAND HOLE SIZE AND EXACT LOCATION PULLBOX AND SEAL OFF. COORDINATE WITH LOCATION OF HAND HOLE (BY CANOPY FABRICATOR)PULLBOX. COORDINATE WITH LOCATION OF HAND HOLE (BY CANOPY FABRICATOR)GASOLINE CONDUIT REQUIREMENTS:1) 1" GRC SPARE TO COLUMN A OR C AS DICTATED BY FUEL COURT LAYOUT. (SEE SHEET CE1)1) 1" GRC TO CANOPY COLUMN FOR LIGHTING.COLUMN FURTHEST FROM STORE) - COLUMN B.SEE SHEET CE1 FOR COUNT) 4) 3/ 4" GRC TO EACH DISPENSER.1 POWER, 1 DATA, 1 MUSIC/INTERCOM, 1 FUEL-TANK MONITOR SENSOR) 2) 1" GRC TO EACH TANK STP CONTAINMENT SUMP.F.E. PETRO POWER ( 1 POWER, 1 SPARE)1) 3/ 4" GRC TO EACH TANK STP COMPARTMENT SUMP.FUEL-TANK MONITOR MAGNOSTRICTIVE PROBE AND FUEL-TANK MONITOR SENSOR)1) 3/4" GRC TO EACH TANK MULTIPORT CONTAINMENT SUMP. FUEL- TANK MONITOR MULTI- PORT FILL SUMP)1) 3/ 4" GRC TO EACH TANK.FUEL-TANK MONITOR BRINE INTERSTITIAL RESERVOIR)1) 1" GRC TO OVERFILL ALARM. ON VENT STACK)1) 1" GRC TO VENT STACK (SPARE)1) 1" GRC TO E-STOP AT STREET SIDE OF GAS CANOPY ( SEE NOTE 15 ON SHEET E4)SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDDRAWNDATEPROJECT NO.COPYRIGHT © - All reports, plans, specifications, computer files, field data, notes and other documents are instrumentsof service prepared by: Cuhaci & Peterson, (C & P) as instruments of service remain the property of C & P. C & P shall retain all common law, statutory and other reserved rights, including the copyright thereto. Any use or reproduction of this document without written permission from C & P is a violation of Federal copyright laws.4/16/2020 11:23:06 AMCE1218071904-17-2020MLBJPMELECTRICAL CANOPY PLANS, DETAILS, SCHEDULESORANGE AVE. & KINGS HWY, FT. PIERCE, FLWAWA260 WEST BALTIMORE PIKEWAWA, PENNSYLVANIA 19063WAWA STACKED 8 GAS CANOPY 2019.01 STORE #5380- ORN04/17/2020 1/4" = 1'-0"CE1 2 CANOPY SIDE ELEVATION Lighting Fixture Schedule TYPE MANUF CATALOG NO. QUANT. WATTS / LAMP LAMPS /FIXTURE MGT.FD LED - DECK MOUNT - SLOPED ADAPTER 24 114 W 1 SURFACE 1/4" = 1'-0"CE1 1 CANOPY ELECTRICAL REFLECTED CEILING PLAN ALL LIGHT FIXTURES AND LAMPS SUPPLIED BY WAWA, G.C. TO COORDINATE INSTALLATION WITH E.C. AND CANOPY VENDOR.ELECTRICAL NOTES 1 1/ 2" = 1'-0"CE1 3 CANOPY CONDUIT LOCATIONS 1. ALL FIXTURES AND COMPONENTS SHALL BE GROUNDED BY A SEPARATE 10 GROUND WIRE. 2. PETROLEUM CONTRACTOR TO PULL WIRING FOR INTERCOM AT CANOPY SUPPLIED BY OTHERS).3. THE CONDUIT FOR THE "FD" FIXTURES TO RUN ALONG THE GUTTER PAN AND RUN TO THE FIXTURES IN THE FLUTES OF THE DECKING. NO CONDUIT SHOULD BE VISIBLE FROM BELOW THE CANOPY.4. FOR DISPENSER DATA, FUEL-TANK MONITOR, AND INTERCOM/MUSIC PROVIDE CONDUCTORS AND CONNECTIONS AS REQUIRED. COORDINATE WITH WAWA CONSTRUCTION MANAGER.5. NOT USED 6. ELECTRICAL CONTRACTOR TO COORDINATE WITH PETROLEUM CONTRACTOR AND GENERAL CONTRACTOR TO MAKE SURE THAT SEAL OFF FITTINGS AS REQUIRED ARE PROVIDED FOR CONDUITS ENTERING THE FUEL DISPENSERS AND THAT THE ELECTRICAL INSTALLATION AT THE GAS CANOPY AND FUEL TANKS IS IN ACCORDANCE WITH NEC ARTICLE 514.7. FOR BRANCH CIRCUITS OUT TO CANOPY AREA, IF CIRCUIT LENGTH EXCEEDS 100 FEET WIRE/CONDUIT MUST BE SIZED PER FBC- 13-413.1.ABC.1.2 (FLORIDA ONLY).8. LIGHT FIXTURES PROVIDED BY WAWA,G.C TO COORDINATE INSTALLATION OF CONDUIT, WIRING AND FINAL CONNECTION WITH E.C. AND CANOPY VENDOR 9. WAWA GOOSE SIGN, E. C.TO VERIFY EXACT LOCATION WITH G.C AND ARCHITECTURAL DRAWINGS,E. C TO RUN WIRING, CONDUIT AND CONNECT TO LOCAL CIRCUTRY.COORDINATE FIXTURE COUNT, LOCATIONS AND LAMP OUTPUT WITH SITE LIGHTING ENGINEERING DRAWINGS TANKS AND CANOPY CONDUITS AND CONDUCTORS NOTE: THE GENERAL CONTRACTOR SHALL FURNISH AND INSTALL ALL GRC CONDUIT, ASSOCIATED FITTINGS AND WIRE NECESSARY TO PROVIDE A COMPLETE ELECTRICAL SYSTEM FOR THE GAS CANOPY, FUEL TANKS, MUSIC AND INTERCOM SYSTEM. HOWEVER, THE FOLLOWING CONDUIT SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR INDICATED BELOW. FUEL TANKS PETROLEUM CONTRACTOR SHALL FURNISH AND INSTALLTHE CONDUIT FROM THE EDGE OF THE FUELTANK CONCRETE PAD AND