Loading...
HomeMy WebLinkAboutEngineering CODES AND ST NDARDS 1.NAND LOADS AS PER: W AFLORIOA RESIDENTIAL BUILDING CODE 7TH EDITION(2020)WITH AN ULTIMATEDESIGN ne•w ww% d ...I WIND SPEED OF 150 MPH,EXPLGURE B.NOMINAL DESIGN WIND SPEED mr •smr m• �wro CO OF 117 MPH,BURRING RISKCATEGORY I. o www T .m,w,e, O 2.ROOF LIVE LOAD DESIGN 1520 PSF. I o�ww 3.THE PROJECT WAS DESIGNED IN ACCORDANCE WADI THE T,•L j m"`...�.ro. C A FLORIDA BUILDING CODE7TH EDITION(2020). o,m•.emu mmman,m, 1 www. m ~ &BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE wq.mm ae 111 (ACI31812014 EDITION) ❑CONCRETE SLAB CONNECTION HEUCALANCHOR BOW/BASE RAILSPUCE C.MANUAL OFSTANOMD PRACTICE FOR WELDING REINFORCING 6TEEL, CONNECTION CONNECTION INSERTS B CONNECTIONS IN REINFORCED CONCRETE CONSTRUCTION. AWS.D1.4/LATEST EDITION FRECTIONOF D.SPECIFICATION FOR THE STRUCTURAL STEEL OR BUILIDINGS(AMERICAN INSTIM OF STEEL CD CONSTRUCTION AISC I3TH EDITION(ASD). r 4.MATERIALS AND ASSEMBLY TEST AS FOLLOWS A EXTERIOR WINDOWS,SLIDING AND PATIO GLASS DOORS SHALL BE TESTED (VVVf, BY AN APPROVED INDEPENDENT TESTING LABORATORY,AND SHALL BE ' o Lu LABELED WITH ANAPPROVED LABEL IDENTIFYING THE MANUFACTURER, m ou.esnnm PERFORMANCE CHARACTERISTICS ANDEVALUATION ENTITY N ITYPRODUCTFLORIDA STATATION E2. AGENCY,TESTINGGLABOMBERT INDICATE COMPITYOR WITH REQUIREMENTS. TREE i O U OF OF FOLLOWING E INDICATE CAMPUMCE WITH THE REQUIREMEMS LI .-O O�OF ONE OF THE FOILOWWO SPECIFlDATIONS: -MSNAAMPNWWDA101/LS.2-WORTAS202d �L°Ln'B.EXTERIOR DOOR ASSEMBUES SHALL BE TESTED FOR STRUCTURALINTEGRITY Z L/..yyIINACCORDMCEWITHASTM E330ATALOAD OF I.5 TIMES THE REOIRED L. r Q) DESIGN PRESSURE LOAD. a nm p m� //�� F_ LU 0) N O SECTIONAL GARAGE DOORS SHALL BE TESTED FOR DETERMINATION OF a� LJ' M C METALCONNECTOR STRUCDIFFEREURAL NCE WITH ANNIFORMSTATIC TAB PLATE Z O�•C DIFFERENCE IN ACCORDANCE WRIT MSINASMA 1150R TAS 20L202MD203. m � � � �� S.STEEL FRAMES SHALL BE SPACED NO MORETHAN 80.O.C.U.N.O.ON PLAN,ALL TUBE STEEL SHAPE STRENGTHS ME 18 KSI STEELALL CUPS MEW KSI STEEL m�"m B.STEEL WELD STRENGTH SHALL BE 55 KBI TYP.ALL WELDS SHALL BE I/8'MINIMUM CLASSIC•C•FRAME BOW SECTION 2 mm FILLET WELDS. �' 1• ^' Q QL U 7.ANCHORING BUILDING: A BUILDING SHALL BEATTACHEDWITH HEUCALANCHORS PER THE HELICAL ANCHOR DETAIL n'�w.v�oe r .QI r B.WHEN EMBEDDED INTOASPHALTHEUCALANCHORS OR 30•LONG 95 REEM WITH ANUT h �Im ma�awmao'a O O WEIDEO TO THE TOP,SHALLBE INSTALLED AT 1T ON CENTER FROM EACH SIDEAND N THE BAUWLEm 58.ON CENTER ® ev oo J C DO - 1 1i C.WHEN PLACED ON A4'CONCRETE SLAB.A IX EXPANSION ANCHOR WITH 2-11r OF EMBEDMENT [ SHALL BE INSTALLED IT'FROM EACH SIDE AND THE BALANCE o SWON CENTER.CONCRETE SHALL �Q C METALCUP MGLE BE MINIMUM COMPRESSIVE STRENGTH OF 2500 PSIAT28 DAYS. fa a Naa _.•.m y�,,y S.ALL STEELM STEEL FASTENERS ME TO BE I2-14 X 114 HWU ULTRA-2 TOPS CS. B.EACH LOCATION WHERE THE FRAME IS JOINED TOGETHER WILL HAVE 2 SCREWS ON EACH SIDE OF THEJOINT. z mm U 10`PWLDEEND WALLFMMING !�Y/v-L�GZ� uma.m•wrm W 7 IIr ROOF BEAM SCHEDULE I �s a STRUCTURE TYP.SPACING .l� •^f'••U NE OU b Ty z ri 000-20'WIDE 2.25 X 2.25 X 1B GAUGE20'-24'WIDE 225X2.25X 14 GAUGE rma Q30WIDE 225X2.25X12GAUGE �3_ v, a 4� IIr4r WOE END WALL FRAMING 2 J "C FRAME SIDE ELEVATION . O U 41 FTMAX U;Un •-J - ~¢r 0a cn 0 N CONNECTOR SCHEDULE ti� � 5aNM1 a.5w•Na U U CONNECTION O LENGTH TYPE MATERIAL SPACING FROM TYP SPACING e Q W Z EA CORNER Z § as - W Q =w I QQ lea;'48a Lr2 U II.�..rosi METAL SIDING ROOF, 1/4• 3!4" SELFTAPPIND OALV.MTL SCREW 1-7R" of0'O.C. ILm"w"" I"".g o W N O METAL SIDING WALL 1N• Sir SELFTAPPING GALV.MTLSCREW 1-lir o10"O.C. L TUBE TO TUOE 1 3N' SELFTAPPING GALV.MTLSCREW (2)SCREWS 24''0 WIDE END WALL FRAMING a. It EA TUBE 'C FRAME LEFT SIDE FRAMING DETAIL FILE Copy DESIGN DATE: DATE PAGE: PAGE: SION 1: REVISION 2: DATE' SCALE: NTS