Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Revisions
OFFICE USE ONLY: DATE FILED: a PERMIT# REVISION FEE: ��•o d RECEIPT# PLANNING&DEVELOPMENT SERVICES BUILDING&CODE-REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE,FL 34982-5652 (772)462-1553 SECEivED APPLICATION FOR BUILDING PERMIT REVISIONS DEC 2 9 2021 PROJECT INFORMATION St.Lucie County Permitting LOCATION/SITE ADDRESS:. ACQUAVIST LOT 3 4422 N.HIGHWAY AlA DETAILED DESCRIPTION OF PROJECT REVISIONS: REVISED LOCATION OF FLOOD VENTS WITH UPDATED CALCULATIONS CONTRACTOR INFORMATION: STATE of FL RtG/CERT. #: CGc 1527445 ST. LUCIE CO CERT.#: 31143 BUSINESS NAME: ARTAR CONSTRUCTION LLC QUALIFIERS NAME: ARMANDO REYES TOLEDO ADDRESS: 13360 SW 40 STREET CITY: MIAMI STATE: FL ZIP: 33175 PHONE(DAYTIME): 786-344-3855 FAX: OWNER/BUILDER INFORMATION: NAME: VENETIAN ADMINISTRATION LLC ADDRESS:7400 W.FLAGLER STREET CITY: MIAMI. STATE: FL ZIP: 33144 PHONE(DAYTIME: 786-512-4484 FAX: ARCHITECT/ENGINEER INFORMATION. NAME: DAVID S.KNIGHT,P.E. ADDRESS: 2345 14th AVENUE,SUITE 3 CITY: VERO BEACH STATE: FL ZIP: 329620 PHONE(DAYTIME): 772-569-5505 FAX: NA SLCCC. 9123109 Revised 06130117 r ESicc IMES Evaluation Report ESR-4332 DEC 2 9 2021 Reissued March 2020 This report is subject to renewal March 2022. wwwjcc-es.org 1 (800)423-6587 1 (562) 699-85r ing A Subsidiary of the International Code Council® DIVISION:08 00 00—OPENINGS 3.2 Engineered Opening: Section:08 95 43—Vents/Foundation Flood Vents The FV complies with the design principle noted in REPORT HOLDER: Section 2.7.2.2 and Section 2.7.3 of ASCE/ SEI 24-14 (2018 and 2015 IBC and IRC).[Section 2.6.2.2 of ASCE/ SMART PRODUCT INNOVATIONS,INC. SEI 24-05 (2012, 2009, 2006 IBC and IRC)] for a maximum rate of rise. and fall of 5.0 feet per hour EVALUATION SUBJECT: (0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/ SEI 24, Freedom Flood FREEDOM FLOOD VENT-AUTOMATIC FOUNDATION Vent- FVs must be installed in accordance with Section 4.0 below. See Table 1 for vent size and maximum allowable area coverage for a single vent. 1.0 EVALUATION SCOPE 4.0 DESIGN AND INSTALLATION Compliance with the following codes: The model FFV-1608 Freedom Flood Vent'is designed to be installed into walls or overhead doors of existing or new ■ 2018, 2015, 2012, 2009 and 2006 International Building construction. Installation of the vent must be in accordance Code®(IBC) with the manufacturer's instructions, the applicable code, . ■ 2018, 2015, 2012, 2009 and '2006 Intemational and this report. In order to comply with the engineered Residential Code®(IRC) opening design principle noted in Sections 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 (2018 and 2015 IBC and IRC) Properties evaluated: [Section 2.6.2.2 of ASCE/ SEI 24-05 (2012, 2009, 2006 IBC and IRC)],the Freedom Flood Vent- must be installed ■ Physical operation as follows: ■ Water flow ■ With a"minimum of two openings on different sides of ■. Weathering each enclosed area. ■ With a minimum of one FV for every 250 square feet 2.0 USES (23.2 m2)of enclosed area. The model FFV-1608 Freedom Flood Vent'"_ is used to ■ Below the base flood elevation. equalize hydrostatic pressure on walls of enclosures ■ With the bottom of the vent located a maximum of subject to rising or falling floodwaters. With the cover 12 inches bottom f the mm) above the higher of the final removed, the model FFV-1608 also provides natural air ventilation. interior grade or floor and the finished exterior grade immediately under each opening. 3.0 DESCRIPTION 5.0 CONDITIONS OF USE 3.1 General: The Freedom Flood Vent- described in this report n complies with, or is a suitable alternative to what is The model mechanically Freedom i Flood Vent t V) - specified in,those codes listed in Section 1.0 of this report, engineered mechanically operated in-wall flood vent (FV) that automatically allows floodwater to enter an enclosed subject to the following conditions: area and exit. The FV is comprised of a polycarbonate 5.1 The model FF0608 Freedom Flood Vent' unit must frame with mounting flange and a polycarbonate be installed in accordance with this report, the horizontally pivoting door. When subjected to rising water, applicable code and the manufacturer's published the model FFV-1608 Freedom Flood Vent- door is installation instructions. In the event of a conflict, the activated and pivots to allow water and debris to flow in instructions in this report shall govern. either direction to equalize hydrostatic pressure from one• 5.2 The model FFV-1608.Freedom Flood Vent'"unit must side of the enclosure to the other. The FV features a removable polycarbonate cover. The FV door will activate not be used in place of"breakaway walls" in coastalhi h hazard areas, but are and pivot when subjected to rising water with or without the g permitted for use in polycarbonate cover installed. conjunction with breakaway walls in other areas. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.Yhere is no warranty by ICC Evaluation Service,LLC,express or implied as ,= r to any finding or other matter in this report,or as to any product covered by the report'. Copyright©2020 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 4 ESR-4332 I Most ode/y Accepted and Trusted Page 2 of 4 5.3 Use of the Freedom Flood Vent as under-floor space 7.2 The report holder's contact information is the ventilation is outside the scope of this report. following: 6.0 EVIDENCE.SUBMITTED SMART PRODUCT INNOVATIONS, INC. Data in accordance with the ICC-ES Acceptance Criteria 430 ANDBRO DRIVE,UNIT 1PITMAN,NEW JERSEY 08071 for Mechanically Operated Flood Vents (AC364), dated (800)507-1527 August 2015(editorially revised October 2017). www.freedomfloodvent.com 7.0 IDENTIFICATION infoCa_freedomfIoodvent.com 7.1 The Freedom Flood Vent' model recognized in this report must be identified by a label bearing the manufacturer's name (Smart Product Innovations, Inc.)and the evaluation report number(ESR4332.). TABLE 1—FREEDOM FLOOD VENTT" MODEL NAME MODEL NUMBER MODEL SIZE COVERAGE(sq.ft.) Freedom Flood VentTm FFV-1608 153/4°X 81/16' 250 For SI• 'I inch=25 4-RI of FIGURE 1—MODEL FFV-1608 FREEDOM FLOOD VENTTm:SHOWN WITH COVER REMOVED FIGURE 2—MODEL FFV-1608 FREEDOM FLOOD VENT :SHOWN WITH FLOOD DOOR PIVOTED OPEN ESICC ICC-ES Evaluation Report •ESR-4332 CBC and CRC Supplement Reissued March 2020 This report is subject to renewal March 2022. www.icc-es.org 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:08 00 00—OPENINGS Section:08 95 43--Vents I Foundation Flood Vents REPORT HOLDER: SMART PRODUCT INNOVATIONS,INC. EVALUATION SUBJECT: FREEDOM FLOOD VENTTm AUTOMATIC FOUNDATION FLOOD VENT:MODEL FFV-1608 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that the Freedom Flood Vent-Automatic Foundation Flood Vent: Model FFV-1608; recognized in ICC-ES master evaluation report ESR-4332, has also been evaluated for compliance with codes noted below. Applicable code edition(s): K 2016 California Building Code(CBC) ■ 2016 California Residential Code(CRC) 2.0 CONCLUSIONS 2.1 CBC: The Freedom Flood Vent'Automatic Foundation Flood Vent: Model FFV-1608,described in Sections 2.0 through 7.0 of the master evaluation report ESR-4332,complies with CBC Chapters 12, 16 and 16A; provided the design and installation are in accordance with the 2015 International Building Code®(2015 IBC) provisions noted in the master report and the additional requirements of 12, 16,and 16A,as applicable. The product recognized in this supplement has not been evaluated under CBC Chapter 7A for use in the exterior design and construction of-new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any Wildland-Urban Interface Fire Area. 2.2 CRC: The Freedom Flood Vent'Automatic Foundation Flood Vent: Model FFV-1608,described in Sections 2.0 through 7.0 of the master evaluation report ESR-4332, complies with the 2016 CRC, provided the design and installation are in accordance with the 2015 Intemational Residential Code®(2015 IRC)provisions noted in the master report. The product recognized in this supplement has not been evaluated under 2016 CRC Chapter R337,for use in the exterior design and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any Wildland-Urban Interface Fire Area. The product recognized in this supplement has not been evaluated for compliance with the International Wildland-Urban Interface Code®. This supplement expires concurrently with the evaluation report,reissued March 2020. ICC-ESEvaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use There is no wan-anty by ICC Evaluation Service,LLC,express or implied,as = h to any finding or other matter in this report,or as to any product covered by the report. �N. -.. Copyright©2020 ICC Evaluation Service,LLC. All rights reserved. Page 3 of 4 -M. ESWC ICC-ES Evaluation Report ESR4332 FBC Supplement Reissued March 2020 This report is subject to renewal March 2022. www.icc-es.org 1 (800)423-6587 1 (562)699-0543 A Subsidiary of the International Code Council® DIVISION:08 00 OOiOPENINGS Section:08 95 43—Vents i Foundation Flood Vents REPORT HOLDER: SMART PRODUCT INNOVATIONS,INC. EVALUATION SUBJECT: FREEDOM FLOOD VENTTm AUTOMATIC FOUNDATION FLOOD VENT: MODEL FFV-1608 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Freedom Flood Vent' Automatic Foundation Flood Vent: Model FFV-1608, recognized in ICC-ES master evaluation report ESR-4332, has also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2017 Florida Building Code---Building ■ 2017 Florida Building Code—Residential 2.0 CONCLUSIONS The Freedom Flood VentT°"Automatic Foundation Flood Vent: Model FFV-1608,described in Sections 2.0 through 7.0 of the master evaluation report ESR-4332, complies with the Florida Building Code—Building and the Florida Building Code-= Residential, provided the design and installation are in accordance with the Intemational Building Code® (IBC) provisions noted in the master report. Use of the Freedom Flood Vent' Automatic Foundation Flood Vent: Model FFV-1608 has also been found to be in compliance with the High-Velocity Hurricane Zone provisions of the Florida Building Code—Building and the Florida Building Code—Residential For products falling under Florida Rule 9N-3,verification that the report holder's quality assurance program is audited by a. quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity(or the code official,when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the evaluation report,reissued March 2020. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement ofthe subject of the report or a recommendation for its use There is no warranty by ICC Evaluation Service,LLC,express or implied,as i u to any finding or other matter in this report,or as to any produce covered by the report. N. Copyright©2020 ICC Evaluation Service,LLC. All rights reserved. Page of 4 I FLOOD VENT x2 :A•:. _. :,a:>'=r :.•::- (STACKED) RECEIVED FLOOD VENT x4 `°: `*: DEC 2 9 2021 (under wndoe) St.Ludo County }.. �rT• i�s: Permi in 9 1.J; FLOOD VENT CALCULATION B"xl6" ENGINEERED FLOOD VENTS THAT .1.. PROVIDE 250 SF OF FLOOD COVERAGE GARAGE 1522 SF/250 = 6.1 = 7 VENTS _I 9 VENTS PROVIDED . :.. :r�:•:, 4 ,+,:;+`.;," AREAS ,...h..v..5.:t, ' FLOOD VENT x2 LOBBY/STORAGE AMIDE 1321 SF/250 = 5.3 = 6 VENTS ;;,,'s:�.,% -�;c;'.':�t•.'i,.;?j`�,'ri1 :e.q;, ;•t:;:;.1,;5 VENTS PROVIDED + 1 PASS—THRU `• .. BELOW POOL DECK AREA 999 SF/250 5.0 = 5 VENTS c);o4 :�f� ;r�"•!i:h1i>;„:: w�.r '.A:;;;3>` ADD (+1)VENTS FOR PASS—THRU= 6 VENTS S�'''-;I'`:?`. .,...., ,"';;A:';;'•�+ .;'�� '+? 7 VENTS PROVIDED THE DESIGN OF THE FLOOD VENT OPENINGS WILL FLOOD VENT x3 •�'',' "s> •=<;;I,:.;•�+«�•.;�ti�:�J�✓a:is _c z:-:..': PROVIDE FOR EQUALIZATION OF HYDROSTATIC FLOOD =:,+: �.+1.. AUTOMATIC ENTRY AND EXIT OF FLOODWATERS AS SPECIFIED IN SECTION 2.7.2.2 OF ASCE 24. PER FBC '::'.4+.':�; •?+.•„•. ��'� �'•''�"1 � E R322.2.2 FOOT NOTE 2.1 THE BOTTOM OF EACH OPENING SHALL BE NOT MORE B I .`�::`;�+ ::}.`:`•'.')-j= ,y:.':i: THAN 1 FOOT A13OVE-THE HIGHER OF THE FINAL INTERIOR :�.` n! .>.`i:'t,::;::�v°�•: i :�ri ac y+'av....� S : ,. I i FLOOR AND THE FINISHED EXTERIOR GRADE IMMEDIATELY ,i,:y';,}z, EV BELOW THE OPENIN :;.j:� o-r._.,�... FLOOD+VENTr x2:'=1Z. I (INTERNAL) qqEV EWER FOR S' ^� } •},f+, 1)c.la.:1a• +iAyj++�•s'���J� i•£:.1..n•.4.:'i.i..:.,.•.�.';.!,...�\., CODE COMPLIANCE _ ''l�e•t� ;''i: (^'.i:':N: ,.�.i..';I�v^,.e; •ti•'.'::aft.ik.:'i.f::t..i;::1:5. . N !:<,'•a i�. �.'}.•�,'.... +• ; -..,L+:' 'i?:);:.fin;.+y''.'t,;;fi'i.:;i�.t icy+;...• I . �tiY;.L'{'�<:'r.: >".'•"c��+ -�� .}s:.::;.�-.::':.,', ��.�,.,,'r FLOOD VENTBOCC xl k (pass through) .:C::j /A) `nJ'a;''. w.�,lr'! •.`.J rr tiC�'�.tli^J:n.'�.,l.AL.,-.'t5„ti'` ' '^ i�,.. . . •��";� ' FLOOD VENT x2 g ';` r, 5`' ", t'si€;' ?'i'1=5�• FLOOD VENT x3 "j FLOOD VENT x2sr;•' u ':r�:t:i 'i:lY..!y.il �rl::: .:.;�v.:,_. •'+• ik:'� ,r,(`r.,r.:?Z���r�S l4dt�d'j•+ j�Y��; j�,k4�'•I::f•>' o ,•n�:'. :':i: r'�: ';h+1iti'a�'.r,Y�{'�:�i^�(>�.:i"�;�.�,.?..7,:+ ..f z _ FLOOD VENT x2 FLOOD VENT xl � � 3 Zl 1Z 29� DESIGN BY DSK THE DRAWINGS ARE THE PROPERTY OF THE KMA Engineering&Surveying,LLC ENGINEER.WHETHER THE PROJECT FOR WHICH DRAWN BY PMP Structural Concerns • THEY ARE MADE IS EXECUTED OR NOT.COPY OR Consp)tipQQ Enptneers&Surveyors 7� AcquaVista LOT 37-p USE FOR OTHER PROJECTS IS PERMITTED ONLY s0 R%al Palm Pornte Salto 401 Vero Bew"'FL 32960 SCALE AS NOTED EXh1.Ult - FLOOD VENT REPAI.L�S UNAUTHORZED SEE WIL WRITTEN CONTRACT LTBE PROSECUTEDTH THE Phone:(772)5695505 Fex:t772)569.1455 E-Mall:clYll@kmeR.com KMA DATE 12-29-2U27 PURSUANT To THE COPYRIGHT LAWS. Certificate of Authorization Number:337o5 �,:�waeea.rwo