HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS•.f1.1�O4 IIap4Q7NrM Or ,-k_'..� .
Business & Professional Requlation
SCIS Nome Log In User Registration Hot Topics Submit Surcharge Stars & Facts Publications Contact Us 6CIS Site Map Links Search
ProdApproval 1 USEW Public
user
PrpduC[ Agproyal Menu > Protlucl or APQllCaQQn SeArCh > Aoollcatlon LISt > Application Detail
FL * FL21895-R3
Application Type RevlMon
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Sentry Building innovations
Address/Phone/Email 1209 Orange Street Wilmington
New Castle, DE 19801
(604)612-5289
mseth@sentrybuilding.com
Authorized Signature Marsha Hollandsworth
Mholiandsworth@sentrybuilding.com
Technical Representative Marsha Hollandsworth
Address/Phone/Email 1209 Orange Street Wilmington
New Castle, DE 19801
(843) 735-1773
Mhollandsworth@sentrybuilding.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity QAI Laboratories
Quality Assurance Contract Expiration Date 12/31/2023
validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL21895 R3 COI 2020 01 COI NIEMINEN.odf
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D4533 2015
ASTM D4798 2011
ASTM D4869 2016
ASTM D5035 2011
FRSA/TRI, Sixth Edition 2018
UL1897 2015
Equivalence of Product Standards
Certified By
htips:llfloridabuildi ng.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDqufjjgQzTt6YOnnxswE3x!GMgKUcbCNFDmTePl haxjkxfw%3d%3d
1/2
12117121, 12:51 PM
Florida Building Code Online
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Suprimary of Products
Method 1 Option D
11/19/2020
11/23/2020
11/29/2020
02/09/2021
FL*
Model, Number or Name
Description
21895.1
Roofnado Synthetic Roofing
Synthetic roofing underlayments
Undedayments
Limit of Use
Instllatlon Instructions
Approved for use In HVNZ: No
FL21895 R3 II 2020 it 19 FINAL SENTRY FL21895-R3.pdf
Verified By: Robert Nieminen PE-59166
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-97.5
Evaluation Reports
Other: 1.) Refer to ER Section 5 for Umits of Use. 2.) The
FL21895 R3 AE 2020 11 19 FINAL SENTRY FL21895-
&JpI f
design pressure herein pertains to one underlayment assembly
for use in the roof systems. Refer to ER Section 5.8.3.
Created by Independent Third Party: Yes
aa_1k o
Conti d Us:: 2bo1 Well, Stone Road. Tallahassee FL 32399 Phone: OSOA87-1824
The State of Florida Is an AAleeo employer. Coonmaht 2007-2013 State of Honda :: privacy, Statement :: Accessiblllty Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response th a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone w by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to section 455.275(1),
Florida Stables, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address If they have one. The emalls
provided may be used for ofMcIal communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address, which an M made available to the public. To determine If you arc a Ilansee under Chapter 455, F.S., please click JIM.
product Approval Accepts:
=10MEl E
Credi' Cam
Safe
https://floridabuilding.org/pr/pr_app_d0.aspx?parem=wGEVXQwtDqufjgQzTt6YOnnxswE3xiGMgKUcbCNFOmTePlhaxjkxfw%3d%3d 2/2
0
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATIONF'
Sentry Building Innovations Evaluation Report 1392S.02.17-1-R3
1209 Orange Street, Wilmington, FL21895"R3
New Castle, DE 19801 Date of Issuance: 02/16/2017
(843) 73S-1773 Revision 3: 11/19/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance
with the 7th Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: RoofnadoTM Synthetic Roofing Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein
and FBC 1507.1.1.
CONnNUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes
to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review
of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADvERnsEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO)etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5
Prepared by:
t
'iPfixe.as•ae � �:
Robert J.M. Nieminen, P.E.
i?�._Ta �f-�. The facsimile seal appearing was authorised by Robert
Z e�y¢+;=-;
>Nieminen, P.E. 11119/2020. This does not serve as an
Florida Registration No. 59166, Florida DCA ANE1983
_ on
"-s;,,,,,,,.• electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have norwill acquire, a financial interest in any company manufacturing or distributing products forwhich
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest In any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02018, NEMO ETC, LLC
ROOFING COMPONENT EVALUATION:
4.1
4.2
4.3
4.4
NNEMO etc.
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roofnado"' Synthetic Roofing Underlayments, as produced by Sentry Building
Innovations, have demonstrated compliance with the following sections of the 7' Edition (2020) Florida Building
Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to
the Installation Requirements and Limitations / Conditions of Use set forth herein.
Section
Properties
Standard
Year
1504.3.1
Wind resistance
UL1897
2015
1507.1.1, 1507.2.4, 1507.2.9.2 /
Material standard
ASTM D1970
2015
R905.1.1, R905.2.8.2
1507.1.1.1(2&3, Exception),
Tear strength
ASTM D4533
2015
1507.1.1.1(5) / R905.1.1.1(2&3,
Exception), R905.1.1.1(5)
1507.1.1.1(2&3, Exception),
Tensile strength
ASTM D5035
2011
1507.1.1.1(5) / R905.1.1.1(2&3,
Exception), R905.1.1.1(5)
1507.1.1.1(5) / R905.1.1.1(5)
Liquid water transmission
ASTM D4869
2016
2507.3.3 / R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
TAS 110
Accelerated Weathering
ASTM D4798
2011
Endtv
Examination
Reference
Date
NEMO
Evaluation Report
1m-ACT-I9-FBCER.08.19-2-R2
11/19/2020
NEMO (TST6049)
UL 1897
4L-ACT-I8-002.07.18.2
07/05/2019
NEMO (TST6049)
AC152
4S-ACr-18-001.10.18-1B
10/08/2018
NEMO (TST6049)
FRSA/TRI Manual
4S-ACr-18-001.11.18-2B
11/12/2018
QAI(TST9808)
ASTM D1970
RJ5365P-3
04/26/2017
QAI(TST9808)
ASTM D1970 (adhesion)
R15365P-4
06/29/2017
QAI (QUA7628)
Traceability/Inspections
Service Confirmation
08/12/2019
QAI (QUA7628)
Quality Assurance
Florida BCIS
Current
PRODUCT DESCRIPTION:
Product
Material Standard
PIaM(s)
Description
Roofnado"
1507.1.1.1(2&3, Exception),
India
Synthetic polymer -based scrim -reinforced underlayment,
AnchorDeck"
1507.1.1.1(5) /
consisting of woven polyolefin base with a layer of
R905.1.1.1(2&3, Exception),
nonwoven polyolefin sheet and a polymer coating on the
R905.1.1.1(5)
back side, with a nominal unit weight of 2.25 Ibs/square.
Roofnado"
1507.1.1.1(2&3, Exception),
India
Synthetic polymer -based scrim -reinforced underlayment,
StormTread"
1507.1.1.1(5) /
consisting of woven polyolefin base with a layer of
R905.1.1.1(2&3, Exception),
nonwoven polyolefin sheet and a polymer coating on the
R905.1.1.1(5)
back side, with a nominal unit weight of 3.80 Ibs/square.
Roofnadom
1507.1.1.1(2&3, Exception),
India
Synthetic polymer -based scrim -reinforced underlayment,
ShingleLockm
1507.1.1.1(5) /
consisting of woven polyolefin base with a layer of
R905.1.1.1(2&3, Exception),
nonwoven polyolefin sheet and a polymer coating on the
R905.1.1.1(5)
back side, with a nominal unit weight of 3.80 lbs/square.
Roofnadow
ASTM D1970 &
United
Self -adhering underlayment consisting of a synthetic top-
LapLock" PSU
FRSA/TR109-18
Arab
facer, polymer modified bitumen and a release liner,
Emirates
available in rolls 36-inch x 67-ft with a nominal 60-mil
thickness.
NEMO ETC, LLC Evaluation Report 13925.02.17-1-R3
Certificate ofAuthorrsotion a32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL21895-113
Roofnado- Synthetic Roofing Undedayments Revision 3:11/19/2020
Page 2 of 5
"NEMOletc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, In any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Roofnado" Synthetic Roofing Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority
Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering.
5.6 Allowable roof covers:
TABLE 1: ROOF COVER OPTIONS
Ric 10011141WQ:
15071
1507.3
1507.4 a 1507.5
1507.7
15079a 1507.9
Clay and Concrete Tile
Metal
Slate or
Wood
UnderNyment
Asphalt
Shingles
Slate -Type
Mechanical
Adhesive-
Paneh
Shingles
Shingles
Shakes
Attach
Set
Shingles
Roafnado'"
Yes
No
No
Yes
Yes
yes
No
AnchorDeck'm
(residential(
(residential(
Roofnado'"
Yes
No
No
Yes
Yes
Yes
No
StormTread^'
Roofnado"'
Yes
No
No
Yes
Yes
Yes
No
Shinglelock"
Roofnado"
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Bulnt grips, 1507.1.2.3 /
LapLock'"PSU
(Sees.
i
5.6.1 Adhesive -set tile is limited to use of following underlayment /tile adhesive combinations.
TABU: IA: ALLOWABLE UNDERUIYMENr /TILE ADHESIVE COMBINATIONS]
Undedayment
Adhesive
I Florida Product Approval
Roofnado'" LapLock"' PSU
ICP Adhesives "Polysete AH-160"
I FL6332
5.7 Allowable Substrates.
TABLE 2: SUBs7RATE OPTIONS FOR ADHERED UNDERLAYMENTS
Undedayment
Application
Substrates (designed to meet wind loads for project)
Type
primer
Material(s)
Roofnado'" lapLock" PSU
self -adhering
Deck / sheathing
(Optional) ASTM D41
plywood or O5B
Base sheet
None
ASTM D226, Type II felt
t Refer to rile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overtuming Moment Resistance Performance.
NEMO ETC, LLC Evaluation Report 13925.02-77-1-R3
Certificate ofAuthadratlan #32455 7'" EDITION (20201 FBC NON-HVHZ EVALUATION FL21895-R3
Roofnado'" Synthetic Roofing Underlayments Revision 3:11/19/2020
Page 3 of 5
ONEMO I etc.
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not
less than FBC 1S07.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but not less than Section 5.8.3 herein.
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 3.504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
N3 Maximum Design Pressure = -97.S psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41
Underlayment: RoofnadoTM LapLock' PSU, self -adhered and back -nailed 12-inch D.C.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE UmrrATKW
Underlayment
Prepared Roof Cover Installation Type
Maximum Exposure (days)
Roofnado"' AnchorDeck", Roofnado"
StormTread"' or Roofnado"' ShingleLock"'
Mechanically attached
30
Roofnado"' Lapl ock" PSU
Adhesive -set tile
90
Mechanically attached
90
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Roofnado'" LapLock"' PSU
Flat or Lugged
Max. 10-tile stack
4:12
NEMO ETC, LLC
Certificate of Authorization #32455
7- EDITION (2020) FBC NON-HVHZ EVALUATION
Roofnado- synthetic Roofing Underlayments
Evaluation Report 13925.02.17-1-R3
FL21895-R3
Revision 3: 11/19/2020
Page 4 of 5
ON EMO I etc.
6.1 Rcofnado" Synthetic Roofing Underlayments shall be installed in accordance with the manufacturer's
published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted
below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application.
6.3 Roofnado'• AnchorDeck"r, Roofnado"' StormTreacl r or Roofnado" Shinglelock":
6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception),
1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception)
or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation
instructions. FBC requirements take precedence over the manufacturers installation instructions.
6.3.2 Fasteners:
Minimum fasteners shall be corrosion resistant, ring -shank cap nails shall be as set forth in FBC 1507.1.1.1 or
1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3.
6.4 Roofnada- LapLock— PSU:
6.4.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D3970)
in FBC 1507.1.1.1 or 1S07.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof
covering to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type 11 felt, the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.4.2 Tile Applications:
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for the staging limitations.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61620-3 QA requirements.
Refer to Section 4 herein for products and production locations having met codified material standards.
QAI Laboratories —QUA7628; (604) 527-8378, mlansdowne@aai.ora
- END OF EVALUATION REPORT .
NEMO ETC, LLC Evaluation Report 13925.02.17-1-R3
Certificate of Authorization#32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION R21895-R3
Roofnado— Synthetic Roofing Underlayments Revision 3: 11/19/2020