Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS•.f1.1�O4 IIap4Q7NrM Or ,-k_'..� . Business & Professional Requlation SCIS Nome Log In User Registration Hot Topics Submit Surcharge Stars & Facts Publications Contact Us 6CIS Site Map Links Search ProdApproval 1 USEW Public user PrpduC[ Agproyal Menu > Protlucl or APQllCaQQn SeArCh > Aoollcatlon LISt > Application Detail FL * FL21895-R3 Application Type RevlMon Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Sentry Building innovations Address/Phone/Email 1209 Orange Street Wilmington New Castle, DE 19801 (604)612-5289 mseth@sentrybuilding.com Authorized Signature Marsha Hollandsworth Mholiandsworth@sentrybuilding.com Technical Representative Marsha Hollandsworth Address/Phone/Email 1209 Orange Street Wilmington New Castle, DE 19801 (843) 735-1773 Mhollandsworth@sentrybuilding.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity QAI Laboratories Quality Assurance Contract Expiration Date 12/31/2023 validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL21895 R3 COI 2020 01 COI NIEMINEN.odf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D4533 2015 ASTM D4798 2011 ASTM D4869 2016 ASTM D5035 2011 FRSA/TRI, Sixth Edition 2018 UL1897 2015 Equivalence of Product Standards Certified By htips:llfloridabuildi ng.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDqufjjgQzTt6YOnnxswE3x!GMgKUcbCNFDmTePl haxjkxfw%3d%3d 1/2 12117121, 12:51 PM Florida Building Code Online Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Suprimary of Products Method 1 Option D 11/19/2020 11/23/2020 11/29/2020 02/09/2021 FL* Model, Number or Name Description 21895.1 Roofnado Synthetic Roofing Synthetic roofing underlayments Undedayments Limit of Use Instllatlon Instructions Approved for use In HVNZ: No FL21895 R3 II 2020 it 19 FINAL SENTRY FL21895-R3.pdf Verified By: Robert Nieminen PE-59166 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-97.5 Evaluation Reports Other: 1.) Refer to ER Section 5 for Umits of Use. 2.) The FL21895 R3 AE 2020 11 19 FINAL SENTRY FL21895- &JpI f design pressure herein pertains to one underlayment assembly for use in the roof systems. Refer to ER Section 5.8.3. Created by Independent Third Party: Yes aa_1k o Conti d Us:: 2bo1 Well, Stone Road. Tallahassee FL 32399 Phone: OSOA87-1824 The State of Florida Is an AAleeo employer. Coonmaht 2007-2013 State of Honda :: privacy, Statement :: Accessiblllty Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response th a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone w by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to section 455.275(1), Florida Stables, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for ofMcIal communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address, which an M made available to the public. To determine If you arc a Ilansee under Chapter 455, F.S., please click JIM. product Approval Accepts: =10MEl E Credi' Cam Safe https://floridabuilding.org/pr/pr_app_d0.aspx?parem=wGEVXQwtDqufjgQzTt6YOnnxswE3xiGMgKUcbCNFOmTePlhaxjkxfw%3d%3d 2/2 0 NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATIONF' Sentry Building Innovations Evaluation Report 1392S.02.17-1-R3 1209 Orange Street, Wilmington, FL21895"R3 New Castle, DE 19801 Date of Issuance: 02/16/2017 (843) 73S-1773 Revision 3: 11/19/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: RoofnadoTM Synthetic Roofing Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONnNUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADvERnsEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO)etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5 Prepared by: t 'iPfixe.as•ae � �: Robert J.M. Nieminen, P.E. i?�._Ta �f-�. The facsimile seal appearing was authorised by Robert Z e�y¢+;=-; >Nieminen, P.E. 11119/2020. This does not serve as an Florida Registration No. 59166, Florida DCA ANE1983 _ on "-s;,,,,,,,.• electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have norwill acquire, a financial interest in any company manufacturing or distributing products forwhich the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest In any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02018, NEMO ETC, LLC ROOFING COMPONENT EVALUATION: 4.1 4.2 4.3 4.4 NNEMO etc. Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roofnado"' Synthetic Roofing Underlayments, as produced by Sentry Building Innovations, have demonstrated compliance with the following sections of the 7' Edition (2020) Florida Building Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Properties Standard Year 1504.3.1 Wind resistance UL1897 2015 1507.1.1, 1507.2.4, 1507.2.9.2 / Material standard ASTM D1970 2015 R905.1.1, R905.2.8.2 1507.1.1.1(2&3, Exception), Tear strength ASTM D4533 2015 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(2&3, Exception), Tensile strength ASTM D5035 2011 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(5) / R905.1.1.1(5) Liquid water transmission ASTM D4869 2016 2507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018 TAS 110 Accelerated Weathering ASTM D4798 2011 Endtv Examination Reference Date NEMO Evaluation Report 1m-ACT-I9-FBCER.08.19-2-R2 11/19/2020 NEMO (TST6049) UL 1897 4L-ACT-I8-002.07.18.2 07/05/2019 NEMO (TST6049) AC152 4S-ACr-18-001.10.18-1B 10/08/2018 NEMO (TST6049) FRSA/TRI Manual 4S-ACr-18-001.11.18-2B 11/12/2018 QAI(TST9808) ASTM D1970 RJ5365P-3 04/26/2017 QAI(TST9808) ASTM D1970 (adhesion) R15365P-4 06/29/2017 QAI (QUA7628) Traceability/Inspections Service Confirmation 08/12/2019 QAI (QUA7628) Quality Assurance Florida BCIS Current PRODUCT DESCRIPTION: Product Material Standard PIaM(s) Description Roofnado" 1507.1.1.1(2&3, Exception), India Synthetic polymer -based scrim -reinforced underlayment, AnchorDeck" 1507.1.1.1(5) / consisting of woven polyolefin base with a layer of R905.1.1.1(2&3, Exception), nonwoven polyolefin sheet and a polymer coating on the R905.1.1.1(5) back side, with a nominal unit weight of 2.25 Ibs/square. Roofnado" 1507.1.1.1(2&3, Exception), India Synthetic polymer -based scrim -reinforced underlayment, StormTread" 1507.1.1.1(5) / consisting of woven polyolefin base with a layer of R905.1.1.1(2&3, Exception), nonwoven polyolefin sheet and a polymer coating on the R905.1.1.1(5) back side, with a nominal unit weight of 3.80 Ibs/square. Roofnadom 1507.1.1.1(2&3, Exception), India Synthetic polymer -based scrim -reinforced underlayment, ShingleLockm 1507.1.1.1(5) / consisting of woven polyolefin base with a layer of R905.1.1.1(2&3, Exception), nonwoven polyolefin sheet and a polymer coating on the R905.1.1.1(5) back side, with a nominal unit weight of 3.80 lbs/square. Roofnadow ASTM D1970 & United Self -adhering underlayment consisting of a synthetic top- LapLock" PSU FRSA/TR109-18 Arab facer, polymer modified bitumen and a release liner, Emirates available in rolls 36-inch x 67-ft with a nominal 60-mil thickness. NEMO ETC, LLC Evaluation Report 13925.02.17-1-R3 Certificate ofAuthorrsotion a32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL21895-113 Roofnado- Synthetic Roofing Undedayments Revision 3:11/19/2020 Page 2 of 5 "NEMOletc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, In any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Roofnado" Synthetic Roofing Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable roof covers: TABLE 1: ROOF COVER OPTIONS Ric 10011141WQ: 15071 1507.3 1507.4 a 1507.5 1507.7 15079a 1507.9 Clay and Concrete Tile Metal Slate or Wood UnderNyment Asphalt Shingles Slate -Type Mechanical Adhesive- Paneh Shingles Shingles Shakes Attach Set Shingles Roafnado'" Yes No No Yes Yes yes No AnchorDeck'm (residential( (residential( Roofnado'" Yes No No Yes Yes Yes No StormTread^' Roofnado"' Yes No No Yes Yes Yes No Shinglelock" Roofnado" Yes Yes Yes Yes Yes Yes Yes Yes Bulnt grips, 1507.1.2.3 / LapLock'"PSU (Sees. i 5.6.1 Adhesive -set tile is limited to use of following underlayment /tile adhesive combinations. TABU: IA: ALLOWABLE UNDERUIYMENr /TILE ADHESIVE COMBINATIONS] Undedayment Adhesive I Florida Product Approval Roofnado'" LapLock"' PSU ICP Adhesives "Polysete AH-160" I FL6332 5.7 Allowable Substrates. TABLE 2: SUBs7RATE OPTIONS FOR ADHERED UNDERLAYMENTS Undedayment Application Substrates (designed to meet wind loads for project) Type primer Material(s) Roofnado'" lapLock" PSU self -adhering Deck / sheathing (Optional) ASTM D41 plywood or O5B Base sheet None ASTM D226, Type II felt t Refer to rile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overtuming Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 13925.02-77-1-R3 Certificate ofAuthadratlan #32455 7'" EDITION (20201 FBC NON-HVHZ EVALUATION FL21895-R3 Roofnado'" Synthetic Roofing Underlayments Revision 3:11/19/2020 Page 3 of 5 ONEMO I etc. 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not less than FBC 1S07.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but not less than Section 5.8.3 herein. 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 3.504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. N3 Maximum Design Pressure = -97.S psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Underlayment: RoofnadoTM LapLock' PSU, self -adhered and back -nailed 12-inch D.C. 5.9 Exposure Limitations: TABLE 3: EXPOSURE UmrrATKW Underlayment Prepared Roof Cover Installation Type Maximum Exposure (days) Roofnado"' AnchorDeck", Roofnado" StormTread"' or Roofnado"' ShingleLock"' Mechanically attached 30 Roofnado"' Lapl ock" PSU Adhesive -set tile 90 Mechanically attached 90 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Roofnado'" LapLock"' PSU Flat or Lugged Max. 10-tile stack 4:12 NEMO ETC, LLC Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION Roofnado- synthetic Roofing Underlayments Evaluation Report 13925.02.17-1-R3 FL21895-R3 Revision 3: 11/19/2020 Page 4 of 5 ON EMO I etc. 6.1 Rcofnado" Synthetic Roofing Underlayments shall be installed in accordance with the manufacturer's published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.3 Roofnado'• AnchorDeck"r, Roofnado"' StormTreacl r or Roofnado" Shinglelock": 6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturers installation instructions. 6.3.2 Fasteners: Minimum fasteners shall be corrosion resistant, ring -shank cap nails shall be as set forth in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3. 6.4 Roofnada- LapLock— PSU: 6.4.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D3970) in FBC 1507.1.1.1 or 1S07.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type 11 felt, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.4.2 Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for the staging limitations. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61620-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. QAI Laboratories —QUA7628; (604) 527-8378, mlansdowne@aai.ora - END OF EVALUATION REPORT . NEMO ETC, LLC Evaluation Report 13925.02.17-1-R3 Certificate of Authorization#32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION R21895-R3 Roofnado— Synthetic Roofing Underlayments Revision 3: 11/19/2020 Page 5 of 5