Design Pressure Report (Charlene Ulrich Crowe) - Florida Window & Door
Property Information Owner:Charlene Ulrich Crowe Address:4545 S Indian River Dr Fort Pierce, FL 34982 Building Information Wind Zone:165 MPH. Exposure Category:D Minimum Building Dimension:30 ft. Mean Roof Height:20 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 51 80 10 42.4 -54.7 2 End 84 60 10 41.7 -53.4 3 End 85 16 10 43.9 -57.8 4 End 48 28 10 45.4 -60.8 5 End 37 37 10 45.4 -60.8 6 End 61 80 10 41.8 -53.6 7 End 37 53 10 44.5 -59.0 8 End 30 80 10 43.9 -57.8 9 End 49 52 10 43.7 -57.5 10 End 48 29 10 45.4 -60.8 11 End 48 29 10 45.4 -60.8 12 End 48 60 10 43.4 -56.7 13 End 48 15 10 45.4 -60.8 14 End 84 60 10 41.7 -53.4 15 End 85 16 10 43.9 -57.8 16 End 84 60 20 41.7 -53.4 17 End 85 16 20 43.9 -57.8 18 End 31 80 20 43.8 -57.6 19 End 53 50 10 43.6 -57.2 20 End 37 80 10 43.3 -56.6 21 End 37 38 10 45.4 -60.8 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1