HomeMy WebLinkAboutHorizontal Roller 375 20-0610.12NOA No. 20-0610.12
Expiration Date: June 10, 2024
Approval Date: November 19, 2020
Page 1
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
WinDoor, Inc.
104 Triple Diamond Blvd.
Orlando, FL 34275
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: Series “HR 375" Aluminum Horizontal Rolling Window – L.M.I.
APPROVAL DOCUMENT: Drawing No. 375 LMNOA-1 Rev A (former 18-96D) titled “Series-375
Alum. Horiz. Rolling Wdw. (L.M.I)”, sheets 1 through 18 of 18, dated 06/03/20, prepared by manufacturer,
signed and sealed by Lynn Miller, P.E., bearing the Miami-Dade County Product Control Revision stamp
with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control
Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises # 18-1001.11 (18-1001.07 PVT) consists of this page 1 and evidence pages E-1, E-2 and
E-3 and, as well as approval document mentioned above.
The submitted documentation was reviewed by Ishaq I. Chanda, P.E.
Ishaq I. Chanda, P.E.
Product Control Unit Supervisor
NOA No. 20-0610.12
Expiration Date: June 10, 2024
Approval Date: November 19, 2020
E - 1
WinDoor, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1.EVIDENCE SUBMITTED UNDER PREVIOUS NOA(s)
A.DRAWINGS
1.Manufacturer's die drawings and sections (See NOA #18-1001.07)
2.Drawing No 18-96D, titled “Series-375 Alum. Horiz. Rolling Wdw. (L.M.I./S.M.I.)”,
sheets 1 through 6, 6.1, 7, 8, 8.1, 9 and 10 through 16 of 16, dated 02/27/09, prepared
by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E.
B.TESTS (See NOA #18-1001.07)
C.CALCULATIONS (See NOA #18-1001.07)
D.QUALITY ASSURANCE
1.Miami-Dade Department of Regulatory and Economic Resources (RER).
E.MATERIAL CERTIFICATIONS (See NOA #18-1001.07)
F.STATEMENTS (See NOA #18-1001.07)
G.OTHERS
1. Private labeling agreement between WinDoor, Inc. and CGI Windows and Doors, Inc.
document in conformance of RER guideline dated 09/12/2018.
2.NEW EVIDENCE SUBMITTED
A.DRAWINGS
1.Drawing No. 375 LMNOA-1 Rev A (former 18-96D) titled “Series-375 Alum. Horiz. Rolling
Wdw. (L.M.I)”, sheets 1 through 18 of 18, dated 06/03/20, prepared by manufacturer, signed
and sealed by Lynn Miller, P.E.
B. TESTS
1.Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of all PGT Industries, Inc., CGI
Windows and Doors, Inc. and WinDoor, Inc. representative units listed below and tested to
qualify Dowsil 791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by
Fenestration Testing Laboratory, Inc., Test Reports No.:
Ishaq I. Chanda, P.E.
Product Control Unit Supervisor
NOA No. 20-0610.12
Expiration Date: June 10, 2024
Approval Date: November 19, 2020
E - 2
WinDoor, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS (continue):
WinDoor, Inc. test specimens:
FTL-20-2078.1, WinDoor PW3000 Aluminum Fixed Lite (unit 11 in proposal)
FTL-20-2078.2, WinDoor HR9470 Thermally Broken Alum. Horiz. Roller (unit 12)
FTL-20-2078.3, WinDoor SGD8100 Alum. Sliding Glass Door (unit 13 in proposal)
FTL-20-2078.4, WinDoor HR9470 Thermally Broken Alum. Horiz. Roller (unit 14)
FTL-20-2078.5, WinDoor PW9020 Alum. Fixed Lite (unit 15 in proposal) and
FTL-20-2078.6, WinDoor PW9020 Alum. Fixed Lite (unit 16 in proposal)
all dated 09/24/20 and signed and sealed by Idalmis Ortega, P.E.
PGT Industries, Inc. test specimens:
FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14
FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-
2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-
2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4,
PGT PW7620A Aluminum Fixed Window (unit 10 in proposal)
all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E.
CGI Windows and Doors Inc. test specimens:
FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit 1 in proposal) FTL-20-
2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-
2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal) FTL-20-2108.4,
CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and FTL-20-2108.5, CGI SH360
Aluminum Single Hung Window (unit 5 in proposal)
all dated 08/24/20 and signed and sealed by Idalmis Ortega, P.E.
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 7th
Edition (2020), dated 03/26/20 and revised on 06/03/20, prepared by manufacturer,
signed and sealed by Anthony Lynn Miller, P.E.
2. Glazing complies with ASTM E1300-04, -09, -12 and -16.
D. QUALITY ASSURANCE
1. Miami Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1.Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their
“SentryGlas® (Clear and White) Glass Interlayers”, expiring on 07/04/23.
2. Notice of Acceptance No. 18–0301.06 issued to Eastman Chemical Company (MA)
(Former Solutia, Inc.) for the “Saflex CP - Saflex and Saflex HP Composite Glass
Interlayers w/ PET Core”, expiring on 12/11/23.
Ishaq I. Chanda, P.E.
Product Control Unit Supervisor
NOA No. 20-0610.12
Expiration Date: June 10, 2024
Approval Date: November 19, 2020
E - 3
WinDoor, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
F. STATEMENTS
1.Statement letters of conformance to FBC 2020(7th Edition), dated 03/26/20, prepared,
signed & sealed by Lynn Miller, P. E.
2.Notification of Successor Engineer per the Florida Administrative Code Section 61G15-
27.001, notifying original engineer that the successor engineer is assuming full
professional and legal responsibility for all engineering documents pertaining to this
NOA, dated 06/03/20, signed and sealed by A. Lynn Miller, P.E.
3.Private Label Agreement dated 07/17/20 between Windoors, Inc. and CGI Windows and
Doors, signed by Dean M. Ruark, P.E., V.P. Eng., on behalf of respective companies.
G. OTHER
1. This NOA revises NOA No. # 18-1001.11 (18-1001.07 PVT), updates to FBC 2020, expiring
10/06/24.
2. Additional associated reference file #20-1006.07(LMI).
3. RER Test proposals #19-1155 dated 01/10/20 approved by Ishaq I. Chanda, P.E.