Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WALL - MOUNTED HEAT PUMP SYSTEM
Job Name: System Reference:Date: Indoor Unit: MSZ-HM24NA Outdoor Unit: □ MUZ-HM24NA-U1 □ MUZ-HM24NA-U2 Wireless Remote Controller GENERAL FEATURES • Four fan speed options: Low, Medium, High, Super-high • Anti-mold filter • INVERTER-driven compressors and electronic LEVs provide higher efficiency with controlled power usage • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Cooling operation range: 14° F to 115° F • Heating operation range: -4° F to 75° F • Multiple control options available: - Hand-held Remote Controller (provided with unit) - kumo cloud® smart device app for remote access - Third-party interface options - Wired or wireless controllers • 12-hour timer • ECONO COOL mode • AUTO restart • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life SUBMITTAL DATA: MSZ-HM24NA & MUZ-HM24NA 24,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Specifications are subject to change without notice.© 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. M-SERIES Cooling1 Maximum Capacity BTU/H 22,500 Rated Capacity BTU/H 22,500 Minimum Capacity BTU/H 5,800 Maximum Power Input W 2,575 Rated Power Input W 2,630 Moisture Removal Pints/h 2.3 Sensible Heat Factor 0.89 Power Factor %99 / 99 Heating at 47°F2 Maximum Capacity BTU/H 26,000 Rated Capacity BTU/H 26,000 Minimum Capacity BTU/H 5,400 Maximum Power Input W 2,445 Rated Power Input W 2,500 Power Factor %99 / 99 Heating at 17°F3 Maximum Capacity BTU/H 18,500 Rated Capacity BTU/H 18,500 Maximum Power Input W 2,245 Rated Power Input W 2,300 Heating at 5°F4 Maximum Capacity BTU/H 15,600 Maximum Power Input W 2090 Heating at -4°F5 Maximum Capacity BTU/H N/A Heating at -13°F6 Maximum Capacity BTU/H - Efficiency SEER 18.0 EER1 8.6 HSPF (IV)10.0 COP at 47°F2 3.05 COP at 17°F in Maximum Capacity3 2.42 COP at 5°F in Maximum Capacity4 2.19 Electrical Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR)kA 5 Recommended Fuse/Breaker Size (Outdoor)A 15 Recommended Wire Size (Indoor - Outdoor)AWG 14 Indoor Unit MCA A 1 MOCP A 15 Blower Motor Full Load Amperage A 0.67 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 702-530-431-353 Airflow Rate at Cooling, Wet CFM 632-477-388-318 Airflow Rate at Heating, Dry CFM 702-579-448-346 Sound Pressure Level (Cooling)dB(A)50-44-38-33 Sound Pressure Level (Heating)dB(A)50-44-38-32 Drain Pipe Size In. (mm)5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W: In. (mm)36-5/16 (923) D: In. (mm)12 (250) H: In. (mm)9-13/16 (305) SPECIFICATIONS: MSZ-HM24NA & MUZ-HM24NA Specifications are subject to change without notice.© 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Package Dimensions W: In. (mm)39 (990) D: In. (mm)13 (330) H: In. (mm)15 (380) Unit Weight Lbs. (kg)28 (13) Package Weight Lbs. (kg)33 (15) Indoor Unit Operating Temperature Range Cooling Intake Air Temp (Maximum / Minimum)*°F 90 DB, 73 WB / 67 DB, 57 WB Heating Intake Air Temp (Maximum / Minimum)°F 80 DB / 70 DB Outdoor Unit MCA A 14 MOCP A 15 Fan Motor Full Load Amperage A 0.93 Fan Motor Output W 77 Airflow Rate CFM 1,691 / 1,691 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling1 dB(A)54 Sound Pressure Level, Heating2 dB(A)55 Compressor Type DC INVERTER-driven Twin Rotary Compressor Model SNB130FQBMT Compressor Rated Load Amps A 10 Compressor Locked Rotor Amps A 12.5 Compressor Oil Type // Charge oz.FV50S // 11.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional Unit Dimensions W: In. (mm)33-1/16 (840) D: In. (mm)13 (330) H: In. (mm)34-5/8 [880] Package Dimensions W: In. (mm)38-9/16 (980) D: In. (mm)16-9/16 (420) H: In. (mm)39 (990) Unit Weight Lbs. (kg)121 (55) Package Weight Lbs. (kg)141 (64) Outdoor Unit Operating Temperature Range Cooling Air Temp (Maximum / Minimum)*°F 115 / 14 Cooling Thermal Lock-out / Re-start Temperatures**°F -1 / 3 Heating Air Temp (Maximum / Minimum)°F 75 / -4 Heating Thermal Lock-out / Re-start Temperatures**°F -9 / -4 Refrigerant Type R410A Charge Lbs, oz 3, 9 Piping Gas Pipe Size O.D. (Flared)In. (mm)5/8 (15.88) Liquid Pipe Size O.D. (Flared)In. (mm)3/8 (9.52) Maximum Piping Length Ft. (m)100 (30) Maximum Height Difference Ft. (m)50 (15) Maximum Number of Bends 10 Notes AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) 1Cooling (Indoor // Outdoor)°F 80 DB, 67 WB // 95 DB, 75 WB 2Heating at 47°F (Indoor // Outdoor)°F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor)°F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor)°F 70 DB, 60 WB // 5 DB, 4 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SPECIFICATIONS: MSZ-HM24NA & MUZ-HM24NA Specifications are subject to change without notice.© 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Anti-allergy Enzyme Filter □ MAC-408FT-E Remote Controller Holder □ U01A01083 kumo touch™ RedLINK™ Wireless Controller □ MHK2 Deluxe MA Remote Controller1 □ PAR-40MAAU Simple MA Controller1 □ PAC-YT53CRAU-J Touch MA Controller1 □ PAR-CT01MAU-SB Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1 System Control Interface2 □ MAC-334IF-E Wireless Interface 2 □ PAC-USWHS002-WF-2 Thermostat Interface □ PAC-US444CN-1 kumo station®□ PAC-WHS01HC-E USNAP Interface □ PAC-WHS01UP-E IT Extender □ PAC-WHS01IE-E BACnet® and MODBUS® Interface □ PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers □ RCMKP1CB Blue Diamond Sensor Extension Cable —15 Ft.□ C13-103 Blue Diamond Alarm Extension Cable —6.5 Ft.□ C13-192 Blue Diamond MultiTank —collection tank for use with multiple pumps □ C21-014 Blue Diamond Rubber Foot Pads □ F10-010 Mini Condensate Pump —230 volt application □ SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/H[recommended]□ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]□ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H □ X85-003 Fascia Kit for MicroBlue Pump – mounts the MicroBlue and sensor directly beneath the indoor unit □ T18-016 Drain Pan Level Sensor □ SS610E (30A/600V/UL) [fits 2" X 4" utility box] - Black □ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White □ TAZ-MS303W 1 Requires MAC-334IF-E 2 Allows indoor units to connect to an MA Controller ACCESSORIES: MSZ-HM24NA Specifications are subject to change without notice.© 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide □ MAC-886SG-E Drain Socket □ MAC-860DS Optional Defrost Heater □ MAC-642BH-U1 Hail Guard □ HG-A7 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic □ DSD-400P Condensing Unit Mounting Pad 16" x 36" x 3"□ ULTRILITE1 Outdoor Unit Stand —12" High □ QSMS1201M Outdoor Unit Stand —18" High □ QSMS1801M Outdoor Unit Stand —24" High □ QSMS2401M Heavy Duty Wall Mounting Bracket— Coated Steel □ QSWB2000M-1 Heavy Duty Wall Mounting Bracket —316 Series Stainless Steel □ QSWBSS 10' x 3/8" x 10' x 5/8" Lineset (Twin-Tube Insulation)□ MPLS385812T-10 15' x 3/8" x 15' x 5/8" Lineset (Twin-Tube Insulation)□ MPLS385812T-15 30' x 3/8" x 30' x 5/8" Lineset (Twin-Tube Insulation)□ MPLS385812T-30 50' x 3/8" x 50' x 5/8" Lineset (Twin-Tube Insulation)□ MPLS385812T-50 65' x 3/8" x 65' x 5/8" Lineset (Twin-Tube Insulation)□ MPLS385812T-65 100' x 3/8" x 100' x 5/8" Lineset (Twin-Tube Insulation)□ MPLS385812T-100 ACCESSORIES: MUZ-HM24NA Specifications are subject to change without notice.© 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. PipingInsulation Capacity in 24 KBTU/H Ø2 O.D Liquid line Ø5/16 15-3/8 (Flared connection Ø3/8) Gas line Ø15/32 13-3/8 (Flared connection Ø5/8) Drain hose Insulation Ø1-1/8 Connected part Ø5/8 O.DPipingInsulation Capacity in 18 KBTU/H Ø2 O.D Liquid line Ø5/16 15-3/8 (Flared connection Ø1/4) Gas line Ø15/32 13-3/8 (Flared connection Ø1/2) Drain hose Insulation Ø1-1/8 Connected part Ø5/8 O.D 11/16 5-1/22-1/42-1/42-1/2 9-13/16 3/16 35-13/16 36-5/16 1/4 27-15/16 6-5/162-1/1612 2-9/16 2-13/162-1/22-9/16 3-11/16 2-1/169-7/1610-5/161/88-7/8 8-7/83-11/16 8-3/410-3/82-5/16 15-7/8 8-11/16 3-11/16 7/81×7/16 Oblong hole 7/16×13/16 Oblong holeInstallation plate Indoor unit Wall hole Ø3Air in Installation plate 8-1/16 15-3/161-5/88-11/163 1-11/162-9/16 2-9/164-1/2 5-3/41/4Air out Piping Drain hose3-15/16Unit: inch DIMENSIONS: MSZ-HM24NA Specifications are subject to change without notice.© 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch 16-7/16 1-9/16 1-5/8Drain hole 6-7/8 19-11/16132Air in Air in Air out 2-holes 13/32 13/1614-3/1633-1/16 4-5/16 3-3/16 34-5/817-25/32Service panel 3-29/326-1/27-11/16 3544Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 5/8 *1 20 in. or more when front and sides of the unit are clear 14 i n . o r m o r e 4 in . o r m o r e REQUIRED SPACE Clear *14 in. o r m or e 20 in. or m or e * 2 *2 When any 2 sides of left, right and rear of the unit are clear15-3/8FORM# MSZ-HM24NA / MUZ-HM24NA - 202105 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: MUZ-HM24NA Specifications are subject to change without notice.© 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.