Loading...
HomeMy WebLinkAboutAPPROVED PLUMBING 5380-F85FB-v20.0 - Sheet - P1 - WASTE PIPING PLANDIMENSION REFERENCE LINE. ESTABLISHED FROM EDGE OF SLAB) I.E. = -2.00' @ EDGE OF BUILDING DIMENSION REFERENCE LINE. (ESTABLISHED FROM EDGE OF SLAB) DIMENSION REFERENCE LINE. ESTABLISHED FROM EDGE OF SLAB) I.E. = -2.38' @ EDGE OF BUILDING 4" SANITARY I.E. = -3.25 @ 5'-0" OUTSIDE BUILDING 4" SANITARY I.E. = -3.25' @ 5'-0" OUTSIDE BUILDING STAGING WOMEN'S RESTROOM WATER SERVICE ROOM ASSOCIATE OFFICE VESTIBULE B12.2 F3 F5 2" COPPER PIPING FITTINGS TO ADAPT TO UNIT AND EXTEND TO THE FLOOR DRAIN. MAKE THE FIRST 10' OF GREASE PIPING FROM FLOOR SINK AT THE B12.2 RETHERMALIZER EXTRA HEAVY CAST IRON INSTEAD OF PVC. MAKE THE FIRST 10' OF GREASE PIPING FROM FLOOR SINK AT THE B9.1 HOT FOOD TABLE EXTRA HEAVY CAST IRON INSTEAD OF PVC. FLOOR DRAIN GRATE TO BE SET FLUSH WITH TOP OF CONCRETE AND CENTERED UNDER PARTITIONS. FLOOR CLEANOUT TOP TO BE SET FLUSH WITH TOP OF FINISH FLOOR. SEE DETAIL 7/P5. 2" VENT TO BE CONNECTED WITH GREASE INTERCEPTOR AT THE INLET AND OUTLET. 1-1/2" PVC BELOW FLOOR FOR 1/2" HW LINE TO B9.1. MAKE FIRST 10' DOWNSTREAM OF PIPING FROM FLOOR SINK AT THE B42.2 (BREAD OVEN) EXTRA HEAVY CAST IRON INSTEAD OF PVC. RUN IN WALL, TERMINATE 6" ABOVE THE CEILING. EACH MULTI-COMPARTMENT SINK SHALL DISCHARGE INDEPENDENTLY TO AN INDIRECT WASTE RECEPTOR WITH AN AIR GAP. ROUTE CONDENSATE LINE THRU WALL TO HUB DRAIN. 2" PVC BELOW FLOOR FOR 3/4" CSRX LINE TO (2) EQ B37.1 & EQ B40 1-1/2" PVC BELOW FLOOR FOR 1/2" HWR, 2" PVC BELOW FLOOR FOR 3/4" CSRX, 2" PVC BELOW FLOOR FOR 3/4" HW, 2" PVC BELOW FLOOR FOR 3/4" CW, 1-1/2" PVC BELOW FLOOR FOR 1/2" CSR. 2" PVC BELOW FLOOR FOR 1/2'' HW, 2'' PVC BELOW FLOOR FOR 1/2'' CW. ROOF DRAINAGE NOTE: PROVIDE ROOF DRAIN (RD-1, TYPICAL OF 7) AND ROOF DRAIN OUTLET PIPE. ROUTE PIPE TO DOWNSPOUT AND INTO DOWNSPOUT. SEE SHEET P3 FOR ROOF PLAN DRAINS AND DETAILS ON SHEET A3.1 FOR ROOF DRAIN AND PIPING INSTALLATION. SANITARY INVERT NOTE: 3.25' I.E. AT 5'-0" OUTSIDE BUILDING IS A COMMON ELEVATION FOR REFERENCE. COORDINATE ACTUAL ELEVATIONS WITH SITE CONTRACTOR WITH REGARDS TO SITE SANITARY MAIN INVERT. 1 2 3 4 5 6 7 8 9 10 11 12 13 PLUMBING KEYNOTES EWC-1 LAV-2 MR-1 ECO 6" øSTECO6" ø STECO6"ø ST 6"ø ST ECO 6"ø ST ECO 6"ø STECO6"ø STECO 6"ø ST6" ø STECO ECO ROOF TOTAL = 192 SFROOFTOTAL = 308 SF ROOF TOTAL = 283SFROOFTOTAL = 280 SFROOF TOTAL = 330 SF ROOF TOTAL = 134 SFROOF TOTAL = 123 SF 6" ø STECO 4" GREASE I. E. = -3.25' @ 5'-0" OUTSIDE BUILDING DIMENSION REFERENCE LINE. ESTABLISHED FROM EDGE OF SLAB) I.E. = -3.10' @ EDGE OF BUILDING F5 B24 F5 B1. 1 B1. 2 B1. 2 B9.1 F5 F5 ELECTRICAL ROOM WASH ROOM FOOD SERVICE FOOD SERVICE COFFEE RETAIL AREA MEN'S RESTROOM REAR VESTIBULE RETAIL WALK-IN REFRIG. DELIVERY VESTIBULE SELF SERVICE WALK- IN REFRIG. WALK-IN FREEZER WALK- IN REFRIG.B1. 2 C17. 3 B41 B37.1 B37.1 C22C28 C22 C28 C23C21 UR-1WC- 1 LAV-2 WC-1 EWH- 16"øST3" ø S 3" ø S4"ø S4"ø S3" ø S 3" ø S 3" ø S3"ø S3"ø S3"øS3"ø S3" ø GR3"ø GR 3"ø GR 3"ø GR3"ø S4" ø GR4" ø GR3"ø GR3"ø GR4" ø GR3"ø GR 3"ø GR3"ø GR4"ø S4"ø S 4" ø S4" ø S 3"ø S1 1/ 2" ø V2 1/2" ø V FD-1WC- 1 FCO FD-1 FCO FCOLAV-1 3" ø S4"ø S4"ø S2"ø V 4" ø S3"ø SHUB-1 HUB- 1 FD-3 HUB-1 FD- 1 HUB- 1 HUB-1 HUB-1 HUB-1 HUB-1 HUB-1FCO HUB-1 C3. 4 C3.3 3"ø GRHUB-1 2 1/2" ø VTR 2"ø VTR 2 1/2"ø VTR C19. 1 HUB-1 3"ø S 2"ø V2"ø V4"ø S3" ø S3"ø S3"ø S3"ø S 3"ø S3"ø S3"ø S4" ø S3"ø S3" ø S3" ø S3" ø GR 3"ø GRFD-1 3"ø GR 3" ø GR3" ø GR 3"ø GR3" ø GR3" ø GR2 1/2" ø V1 1/2" ø V2" ø V2" ø V 2"ø V2"ø V2 1/ 2"ø V 2" ø V2 1/2" ø V2 1/2" ø V 2"ø V2"ø V2"ø V 1 1/2" ø V2" ø V 1 1/ 2"ø V 1 1/2" ø V 1 1/ 2"ø V 2" ø V2" ø V 1 1/ 2"ø V 1 1/2" ø V 2 1/ 2"ø V1 1/ 2"ø V F5 FD-1 ECO HUB- 1 FS- 1 FS- 1 HUB- 1 FS- 1 FS- 1 FS- 5 FS- 5 FS-5 AAV0'- 0"2'-5"7'- 9"9'-1"10'- 4"11'-6"12'-0"14'-6" 19'-1"26'- 3" 27'- 11" 29'- 6" 32'- 6" 34'- 4" 35'- 7" 36'-11"37'-11" 43'- 2" 45'- 2" 46'- 3" 0'- 0" 2'- 0" 7'- 7" 10'- 10" 12'- 2"15'- 10"16'-8" 16'-10"17'-7" 35'-3"35'- 9"43'- 4"46'- 3" 0'- 0" 0'-1"2'- 6"4'- 3"5'- 0"6'- 2"7'- 11"9'-6" 9'- 8"9'-11" 11'-8"12'-11"14'- 0"21'-3"22'-