HomeMy WebLinkAbout5380-F85FB-v20.0 - Sheet - P2 - WATER PIPING PLANWATER SOFTENER
MFR: KINETICO
MODEL #: CP216sOD
2"ø CW
STAGING
WATER SERVICE
ROOM
VESTIBULE
B12.2
F3
WATER SUB-METER:
MANUFACTURER MASTER METER
MODEL: M22-A00-A04-0412A-1, 1-1/2" MAIN WATER SUB-METER.
DOMESTIC WATER PIPING:
USE FLOWGUARD GOLD CTS CPVC PIPING AND FITTINGS.
F5
2" CW BY-PASS
NORMALLY CLOSED
LOCATE SHUTOFF VALVES 24" BELOW CEILING IN WATER SERVICE ROOM.
3/4" COLD WATER LINE RUN DOWN IN WALL AND THEN UNDERGROUND. CONTINUE COLD WATER
LINE UNDERGROUND TO WALL HYDRANT LOCATED IN TRASH COMPOUND WALL. USE POLY PEX
PIPE. REFER TO TRASH COMPOUND SHEET A10.
RUN 3/4" CSRX WATER LINE DOWN IN WALL, BELOW SLAB, THEN UP INTO CABINETRY TO
CONNECT TO (2) B37.1 & B40. INSTALL WATER FILTER FURNISHED WITH EQUIPMENT TO B40.
1/2" CSR LINE FOR COLD BREW. SEE DETAIL 1 OF SHEET P5.
FREESTYLE BOOSTER PUMP MOUNTED ON BIB RACK AT APPROX. 6'-6".
3/4" CSRX WATER INSIDE CABINETRY. 1/2" CSRX TO (2) B26.2, 1/2" CSRX WATER TO B29.1. RUN
PIPING AS CLOSE TO BACK OF CABINETRY AS POSSIBLE.
RUN 1/2" HW LINE UNDER SLAB AND THEN COME UP TO CONNECT TO B9.1. PEX PIPING TO BE
USED. RUN PEX UNDERGROUND INSIDE 1-1/2" CONDUIT.
1/2" CSRX AND 1/2" CW FEMALE FLEXIBLE HOSE OUTLET CONNECTIONS TO B42.2 BREAD OVEN.
CSRX TO GENERATOR AND TAP WATER TO CLEAN THE OVEN.
RUN 1/2" HW LINE AND CONNECT TO B12.2.
1/2" CSR WATER LINE TO C21.
1/2" CSR WATER TO C23.
1/2" FILTERED WATER TO C22, 1/2" CSRX WATER TO C28.
MANIFOLD OF VALVES FOR RESTROOMS TO BE LOCATED 12 INCHES ABOVE DROP CEILING.
FREESTYLE FILTER MOUNTED TO WALL.
2" DOMESTIC WATER MANIFOLD, 1" CW TO CSR SYSTEM, 2" CW TO TOILET ROOMS, 1 1/2" CW TO
STORE, 3/4" CW TO ROOFTOP WALL HYDRANT, 3/4" CW TO CANOPY WALL HYDRANT, 3/4" CW TO
EXTERIOR WALL HYDRANT, 1/2" UNSOFTENED CW TO FREESTYLE FILTER. LOCATE SHUT-OFF
VALVES 24" BELOW CEILING IN WATER ROOM.
1/2" CW BEFORE WATER SOFTENER SYSTEM FOR FREESTYLE.
INCOMING PRESSURE TO BUILDING SHALL BE A MINIMUM OF 55 PSI STATIC AT STREET AND A
MINIMUM OF 50 PSI STATIC SHALL BE MAINTAINED AT BUILDING AFTER METER AND BACKFLOW.
INSTALL A 1-1/2" WATER SUB-METER WITH ONE PULSE PER 10 GALLON DRY CONTACT FOR
INTERLINK TO BAS SYSTEM.
WATER SERVICE SHALL COME DIRECTLY INTO BUILDING WITH NO FITTING PER SITE
ENGINEERING PLAN SE-1. (DEEP LONG SWEEP IS REQUIRED TO GET INTO BUILDING.)
2" DOMESTIC WATER SERVICE. METER LOCATED IN EXTERIOR PIT. SEE CIVIL PLAN FOR
CONTINUATION.
WATER PRESSURE GAUGE WATTS LFDPG1-3 (0-100 PSI).
NOT USED.
ACI PRESSURE TRANSDUCER, PART # A/GP-100-20.
BOOSTER PUMP CONTROLLER (WITH BYPASS SEE WATER RISER.)
CSR SURGE TANK MOUNTED ON PLATFORM. (MOUNT @ 7'-10" A.F.F.).
1/2" HWR, 3/4" CSRX, 3/4" HW, 3/4" CW, 1/2" CSR PIPING RUN DOWN IN WALL, BELOW SLAB, THEN
UP INTO CABINETRY. RUN ALL PIPING AS CLOSE TO BACK OF CABINETRY AS POSSIBLE.
1/2'' HW, 1/2'' CW PIPING RUN DOWN IN WALL, BELOW SLAB, THEN UP IN CABINET IN RETAIL AREA.
DOMESTIC WATER PIPING NOTE:
1. ALL HOT AND COLD WATER PIPING LOCATED IN EXTERIOR WALLS SHALL BE INSULATED. ALL
HOT WATER RETURN NEEDS TO BE INSULATED.
2. USE PEX PIPING FOR ALL WATER LINES UNDER SLAB.
PLUMBING VALVE NOTE:
PLUMBING CONTRACTOR TO LABEL ALL VALVES WITH A PERMANENT TAG.
IRRIGATION PIPING NOTE:
INSTALL 1 1/2" LAWN IRRIGATION SUPPLY, 1" RPZ BACKFLOW PREVENTER, 1" WATER SUB-METER
WITH 1 PULSE PER 1 GALLON DRY CONTACT FOR INTERLINK TO BAS SYSTEM. WATER SUB-
METER, MANUFACTURER MASTER METER, MODEL B16-A31-A04-0312A-1
DO NOT INTERLINK IRRIGATION TO BAS IF RECLAIM WATER IS AVAILABLE.) VERIFY
REQUIREMENTS WITH WAWA PROJECT MANAGER.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
PLUMBING KEYNOTES
ROUTE 3/4" CW UP TO
WCH AT ROOF LEVEL
PROVIDE WATER TANKER
HOOK UP INSIDE WATER
SERVICE ROOM, TIE IN
BEFORE SOFTENER
WCH
3/4"ø CW
EWH-1
BP-1
EWC-1
WCH
LAV-2
MR-1
PROVIDE 4" PVC SLEEVE
PIPE FOR WATER HOOK
UP. CAP BOTH ENDS.
REFER TO ARCH
EXTERIOR ELEVATIONS
FOR EXACT LOCATION.
SELF SERVICE
WALK-IN REFRIG.
DELIVERY VESTIBULE
RETAIL AREA
FOOD SERVICE
WASH ROOM
ELECTRICAL ROOM
MEN'SRESTROOMWOMEN'S RESTROOM
REAR VESTIBULE
WALK-IN FREEZER
WALK-IN REFRIG.
COFFEE
ASSOCIATE
OFFICE
RETAIL WALK-IN
REFRIG.
UR-1
WC-1 LAV-2 WC-1
F5
F5
F5
F5
F5B9.1
B40
B37.1
B37.1
C22
C28
C22
C28 C23C21
2" CW TO RESTROOMS
1" CW TO CSR UNIT
1 1/2" CW TO STORE
3/4" CW TO ROOF WCH
3/4" CW TO WALL WCH
1/2" UNSOFTENED CW TO FREESTYLE FILTER
WC-1
B29.1
SRX
1/2"ø
CW3/4"ø CW1"ø
CW3/4"ø CW2"
ø CW 1 1/
2"ø CW
1/2"ø CW2"
ø CW1/2"ø
TW 1/2"ø
TW 1"ø CW1"
ø CW3/4"ø CW 1/2"ø TW 1/
2"ø TW 1
1/4"ø
HW1"ø CW1 1/
2"ø CW 1
1/2"
ø CW
1 1/
2"ø
CW1"ø CW3/4"
ø CW
1/2"ø CW1/
2"ø HW1/2"
ø CW1/2"ø
HW1/2"ø CW1/
2"ø HW3/4"ø HW1/
2"ø HWR1"ø
HW1"ø HW 1"
ø HW3/4"ø
HW 1/2"ø
HWR MX-2 MX-
2 MX-2 MX-
2 MX-2 MX-
2 MX-2 MX-
2 BELOW
SINK MX-
2BELOW
SINK MX-2 BELOW SINK
SWINGING
CHECK
VALVES
ON
HOT
WATER
TO
ALL
SINKS (
TYP.)
1/
2"
ø
HW1/
2"
ø
HW1/2"
ø
CW1/
2"
øHWR3/4"
ø CSR
3/4"
ø CSRX
1/2"ø FW
1/
2"ø
FW1/
2"ø
CSRX1/2"ø CSR1/
2"ø CSR 3/
4"
ø
CSRX 1/2"ø
CSR1/
2"
ø CSRX 3/4"ø CSRX 3/4"ø
CW B26.3 B26.3 3/4"ø
CW3/
4"
ø HW1/
2"
ø
HWR3/
4"ø
CSRX3/
4"ø
CSRXSA
SASASA
3/
4"
ø
CW3/
4"
ø CW1 1/2"ø HW1 1/
4"
ø
HW 1
2
3 4
5 6
7 8
9
10 11
12
13 14 15 16 171819
202223 24 25 25 RP-
1MX-1 MX-1 MX-
1 MX-
1
1/2"
ø CSRX
MW4 MW9.
1 MW4 LAV-
1 1/2"ø CW
1/
2"ø HW 26
26 MX-
2 BELOW
SINK FLOOR
NOTES:1.
COORDINATE ALL
EQUIPMENT WITH
FREESTYLE,
ARCHITECT AND WAWA.
2. COORDINATE
ACCESS TO
HUB DRAIN
WITH ARCHITECTURAL.
CSRX CSR
ICE
MACHINE
C28
CSR SYSTEM RACK "
BIB"D1 ICE MACHINEC28
FREESTYLE MACHINE C22 FREESTYLE
MACHINE C22REFER
TO CSR DETAIL FOR