Loading...
HomeMy WebLinkAbout5380-F85FB-v20.0 - Sheet - P2 - WATER PIPING PLANWATER SOFTENER MFR: KINETICO MODEL #: CP216sOD 2"ø CW STAGING WATER SERVICE ROOM VESTIBULE B12.2 F3 WATER SUB-METER: MANUFACTURER MASTER METER MODEL: M22-A00-A04-0412A-1, 1-1/2" MAIN WATER SUB-METER. DOMESTIC WATER PIPING: USE FLOWGUARD GOLD CTS CPVC PIPING AND FITTINGS. F5 2" CW BY-PASS NORMALLY CLOSED LOCATE SHUTOFF VALVES 24" BELOW CEILING IN WATER SERVICE ROOM. 3/4" COLD WATER LINE RUN DOWN IN WALL AND THEN UNDERGROUND. CONTINUE COLD WATER LINE UNDERGROUND TO WALL HYDRANT LOCATED IN TRASH COMPOUND WALL. USE POLY PEX PIPE. REFER TO TRASH COMPOUND SHEET A10. RUN 3/4" CSRX WATER LINE DOWN IN WALL, BELOW SLAB, THEN UP INTO CABINETRY TO CONNECT TO (2) B37.1 & B40. INSTALL WATER FILTER FURNISHED WITH EQUIPMENT TO B40. 1/2" CSR LINE FOR COLD BREW. SEE DETAIL 1 OF SHEET P5. FREESTYLE BOOSTER PUMP MOUNTED ON BIB RACK AT APPROX. 6'-6". 3/4" CSRX WATER INSIDE CABINETRY. 1/2" CSRX TO (2) B26.2, 1/2" CSRX WATER TO B29.1. RUN PIPING AS CLOSE TO BACK OF CABINETRY AS POSSIBLE. RUN 1/2" HW LINE UNDER SLAB AND THEN COME UP TO CONNECT TO B9.1. PEX PIPING TO BE USED. RUN PEX UNDERGROUND INSIDE 1-1/2" CONDUIT. 1/2" CSRX AND 1/2" CW FEMALE FLEXIBLE HOSE OUTLET CONNECTIONS TO B42.2 BREAD OVEN. CSRX TO GENERATOR AND TAP WATER TO CLEAN THE OVEN. RUN 1/2" HW LINE AND CONNECT TO B12.2. 1/2" CSR WATER LINE TO C21. 1/2" CSR WATER TO C23. 1/2" FILTERED WATER TO C22, 1/2" CSRX WATER TO C28. MANIFOLD OF VALVES FOR RESTROOMS TO BE LOCATED 12 INCHES ABOVE DROP CEILING. FREESTYLE FILTER MOUNTED TO WALL. 2" DOMESTIC WATER MANIFOLD, 1" CW TO CSR SYSTEM, 2" CW TO TOILET ROOMS, 1 1/2" CW TO STORE, 3/4" CW TO ROOFTOP WALL HYDRANT, 3/4" CW TO CANOPY WALL HYDRANT, 3/4" CW TO EXTERIOR WALL HYDRANT, 1/2" UNSOFTENED CW TO FREESTYLE FILTER. LOCATE SHUT-OFF VALVES 24" BELOW CEILING IN WATER ROOM. 1/2" CW BEFORE WATER SOFTENER SYSTEM FOR FREESTYLE. INCOMING PRESSURE TO BUILDING SHALL BE A MINIMUM OF 55 PSI STATIC AT STREET AND A MINIMUM OF 50 PSI STATIC SHALL BE MAINTAINED AT BUILDING AFTER METER AND BACKFLOW. INSTALL A 1-1/2" WATER SUB-METER WITH ONE PULSE PER 10 GALLON DRY CONTACT FOR INTERLINK TO BAS SYSTEM. WATER SERVICE SHALL COME DIRECTLY INTO BUILDING WITH NO FITTING PER SITE ENGINEERING PLAN SE-1. (DEEP LONG SWEEP IS REQUIRED TO GET INTO BUILDING.) 2" DOMESTIC WATER SERVICE. METER LOCATED IN EXTERIOR PIT. SEE CIVIL PLAN FOR CONTINUATION. WATER PRESSURE GAUGE WATTS LFDPG1-3 (0-100 PSI). NOT USED. ACI PRESSURE TRANSDUCER, PART # A/GP-100-20. BOOSTER PUMP CONTROLLER (WITH BYPASS SEE WATER RISER.) CSR SURGE TANK MOUNTED ON PLATFORM. (MOUNT @ 7'-10" A.F.F.). 1/2" HWR, 3/4" CSRX, 3/4" HW, 3/4" CW, 1/2" CSR PIPING RUN DOWN IN WALL, BELOW SLAB, THEN UP INTO CABINETRY. RUN ALL PIPING AS CLOSE TO BACK OF CABINETRY AS POSSIBLE. 1/2'' HW, 1/2'' CW PIPING RUN DOWN IN WALL, BELOW SLAB, THEN UP IN CABINET IN RETAIL AREA. DOMESTIC WATER PIPING NOTE: 1. ALL HOT AND COLD WATER PIPING LOCATED IN EXTERIOR WALLS SHALL BE INSULATED. ALL HOT WATER RETURN NEEDS TO BE INSULATED. 2. USE PEX PIPING FOR ALL WATER LINES UNDER SLAB. PLUMBING VALVE NOTE: PLUMBING CONTRACTOR TO LABEL ALL VALVES WITH A PERMANENT TAG. IRRIGATION PIPING NOTE: INSTALL 1 1/2" LAWN IRRIGATION SUPPLY, 1" RPZ BACKFLOW PREVENTER, 1" WATER SUB-METER WITH 1 PULSE PER 1 GALLON DRY CONTACT FOR INTERLINK TO BAS SYSTEM. WATER SUB- METER, MANUFACTURER MASTER METER, MODEL B16-A31-A04-0312A-1 DO NOT INTERLINK IRRIGATION TO BAS IF RECLAIM WATER IS AVAILABLE.) VERIFY REQUIREMENTS WITH WAWA PROJECT MANAGER. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 PLUMBING KEYNOTES ROUTE 3/4" CW UP TO WCH AT ROOF LEVEL PROVIDE WATER TANKER HOOK UP INSIDE WATER SERVICE ROOM, TIE IN BEFORE SOFTENER WCH 3/4"ø CW EWH-1 BP-1 EWC-1 WCH LAV-2 MR-1 PROVIDE 4" PVC SLEEVE PIPE FOR WATER HOOK UP. CAP BOTH ENDS. REFER TO ARCH EXTERIOR ELEVATIONS FOR EXACT LOCATION. SELF SERVICE WALK-IN REFRIG. DELIVERY VESTIBULE RETAIL AREA FOOD SERVICE WASH ROOM ELECTRICAL ROOM MEN'SRESTROOMWOMEN'S RESTROOM REAR VESTIBULE WALK-IN FREEZER WALK-IN REFRIG. COFFEE ASSOCIATE OFFICE RETAIL WALK-IN REFRIG. UR-1 WC-1 LAV-2 WC-1 F5 F5 F5 F5 F5B9.1 B40 B37.1 B37.1 C22 C28 C22 C28 C23C21 2" CW TO RESTROOMS 1" CW TO CSR UNIT 1 1/2" CW TO STORE 3/4" CW TO ROOF WCH 3/4" CW TO WALL WCH 1/2" UNSOFTENED CW TO FREESTYLE FILTER WC-1 B29.1 SRX 1/2"ø CW3/4"ø CW1"ø CW3/4"ø CW2" ø CW 1 1/ 2"ø CW 1/2"ø CW2" ø CW1/2"ø TW 1/2"ø TW 1"ø CW1" ø CW3/4"ø CW 1/2"ø TW 1/ 2"ø TW 1 1/4"ø HW1"ø CW1 1/ 2"ø CW 1 1/2" ø CW 1 1/ 2"ø CW1"ø CW3/4" ø CW 1/2"ø CW1/ 2"ø HW1/2" ø CW1/2"ø HW1/2"ø CW1/ 2"ø HW3/4"ø HW1/ 2"ø HWR1"ø HW1"ø HW 1" ø HW3/4"ø HW 1/2"ø HWR MX-2 MX- 2 MX-2 MX- 2 MX-2 MX- 2 MX-2 MX- 2 BELOW SINK MX- 2BELOW SINK MX-2 BELOW SINK SWINGING CHECK VALVES ON HOT WATER TO ALL SINKS ( TYP.) 1/ 2" ø HW1/ 2" ø HW1/2" ø CW1/ 2" øHWR3/4" ø CSR 3/4" ø CSRX 1/2"ø FW 1/ 2"ø FW1/ 2"ø CSRX1/2"ø CSR1/ 2"ø CSR 3/ 4" ø CSRX 1/2"ø CSR1/ 2" ø CSRX 3/4"ø CSRX 3/4"ø CW B26.3 B26.3 3/4"ø CW3/ 4" ø HW1/ 2" ø HWR3/ 4"ø CSRX3/ 4"ø CSRXSA SASASA 3/ 4" ø CW3/ 4" ø CW1 1/2"ø HW1 1/ 4" ø HW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 171819 202223 24 25 25 RP- 1MX-1 MX-1 MX- 1 MX- 1 1/2" ø CSRX MW4 MW9. 1 MW4 LAV- 1 1/2"ø CW 1/ 2"ø HW 26 26 MX- 2 BELOW SINK FLOOR NOTES:1. COORDINATE ALL EQUIPMENT WITH FREESTYLE, ARCHITECT AND WAWA. 2. COORDINATE ACCESS TO HUB DRAIN WITH ARCHITECTURAL. CSRX CSR ICE MACHINE C28 CSR SYSTEM RACK " BIB"D1 ICE MACHINEC28 FREESTYLE MACHINE C22 FREESTYLE MACHINE C22REFER TO CSR DETAIL FOR