5380-F85FB-v20.0 - Sheet - P5 - PLUMBING SCHEDULE & DETAILS
BACKFLOW PREVENTER SCHEDULE SERVICE & APPLICATION MANUFACTURER SERIES MODEL #SIZE REMARKS 8 WATTS REGULATOR SERIES SD-3 MODEL SD3-MN 3/ 8" WATTS REGULATOR SERIES 7 MODEL LF7 3/ 4" WATTS REGULATOR SERIES 7 MODEL LF7 1/ 2"LEAD FREE WATTS REGULATOR SERIES 7 MODEL LF7 3/ 4"LOCATED INSIDE THE BUILDING WATTS REGULATOR SERIES N36 MODEL LFN36-M1 3/ 4" WATTS REGULATOR SERIES 9D MODEL 9D-M3 1/ 2" LEAD FREE LEAD FREE FREESTYLE, ICEE MACHINE, ICED TEA & ICE MAKER CSR" WATER SUPPLY HOT FOOD TABLE & RETHERMALIZER EXTERIOR GROUND HYDRANT VACUUM RELIEF FITTING (WH-1) SANITIZING EQUIPMENT @ MR-1 WATTS REGULATOR SERIES 909 MODEL LF909M1QT-S 11/2"WHEN A "RPZ" TYPE IS REQUIRED WATTS REGULATOR SERIES 007 MODEL LF007M2QT-S 11/2" WHEN A DOUBLE CHECK VALVE IS REQUIRED WATTS REGULATOR SERIES 909 MODEL LF909M1QT-S 1" WHEN VALVE IS LOCATED INSIDE THE BUILDING WATTS REGULATOR SERIES 800 MODEL LF800M4FR 1" WHEN VALVE IS LOCATED OUTSIDE OF THE BUILDING WATTS REGULATOR SERIES SD-3 MODEL SD3-MN 3/" 3/8" M-NPT INLET/OUTLET INDIRECTLY ROUTE VENT DISCHARGE LINE TO FLOOR SINK MAIN WATER SERVICE MAIN WATER SERVICE LAWN IRRIGATION COFFEE & CAPPUCCINO MACHINES LAWN IRRIGATION 3/8" M-NPT INLET/OUTLET INDIRECTLY ROUTE VENT DISCHARGE LINE TO HUB DRAIN PIPING MATERIAL SCHEDULE SERVICE SIZE MATERIAL SCHEDULE/TYPE INSULATION REMARKS TYPE THICKNESS COLD WATER ALL CPVC -ARMAFLEX 1"- HOT WATER ALL CPVC -ARMAFLEX - SANITARY ALL C.I. OR PVC NOTE 3 NONE -NO HUB VENT ALL C.I. OR PVC SCH. 40 NONE -SEE NOTE 1 ST BELOW GRADE ALL C.I. OR PVC SERVICE WEIGHT NONE -NO HUB ST ABOVE GRADE ALL C.I. OR PVC SERVICE WEIGHT FG 1"NO HUB NOTES: 1. WASTE AND VENT PIPING IN PLENUM SPACE SHALL BE SERVICE WEIGHT CAST IRON, NO HUB. 2. FIBERGLASS PIPE INSULATION: MINERAL OR GLASS FIBERS BONDED WITH A THERMOSETTING RESIN. SEMIRIGID BOARD MATERIAL WITH FACTORY- APPLIED ASJ COMPLYING WITH ASTM C 1393, OR WITH PROPERTIES SIMILAR TO ASTM C 612. NOMINAL DENSITY IS 2.5 LB/CU. FT. OR MORE. THERMAL CONDUCTIVITY (K VALUE) AT 100 DEG. F (55 DEG. C) IS 0.29 BTU X IN./H X SQ.FT. X DEG. F (0.042 W/M X K) OR LESS. ALL SERVICE JACKET (ASJ): WHITE, KRAFT-PAPER, FIBERGLASS-REINFORCED SCRIM WITH ALUMINUM-FOIL BACKING; COMPLYING WITH ASTM C 1136, TYPE MANUFACTURER: A. CERTAINTEED CORP., B. JOHNS MANVILLE, C. KNAUF INSULATION, D. OWENS CORNING. 3. FOR PVC ONLY SCHEDULE 40 DWV. FOAM CORE PVC NOT ALLOWED. 1" SHOCK ARRESTOR SCHEDULE P.D.I. SIZE CONNECTION SIZE A (1-11 F.U.)1/2" B (12-32 F.U.)3/4" C (33-60 F.U.)1" P.D.I. = PLUMBING AND DRAINAGE INSTITUTE STANDARD WH-201 INSTALLED ARRESTOR SHALL BE APPROVED DEVICE BY FLORIDA PLUMBING CODE. ALL SUPPLY PIPING SHALL HAVE ARRESTOR THE SAME SIZE AS CONNECTION SIZE UP TO 1" I.E. PROVIDE P.D.I. SIZE "C" FOR 1" OR LARGER WATER SUPPLY TO FIXTURES, P.D.I. SIZE "B" FOR 3/4" SUPPLY AND P.D.I. SIZE "A" FOR 1/2" SUPPLY. SYMBOLS AND ABBREVIATIONS DESCRIPTION ABBR.SYMBOL SANITARY PIPE ABOVE GRADE SAN SANITARY PIPE BELOW GRADE SAN VENT PIPE V COLD WATER PIPE CW HOT WATER PIPE HW STORM ABOVE GRADE ST STORM BELOW GRADE ST STORM OVERFLOW STO ROOF DRAIN RD FLOOR CLEANOUT CO EXTERIOR CLEANOUT ECO WALL CLEANOUT WCO HOSE BIBB HB VENT THRU ROOF EXTEND 36" ABV FINISHED ROOF) VTR DIRECTION OF FLOW SHUT OFF VALVE CAP TEE UP TEE DOWN ELBOW UP ELBOW DOWN REVISION REFERENCE TYPICAL TYP SOME SYMBOLS SHOWN MAY NOT PERTAIN TO THIS PROJECT TEMPERED WATER PIPING TW TW CSR WATER PIPING CSR CSR HOT WATER RETURN PIPE HWR 1 CSRX WATER PIPING CSRX CSRX GREASE PIPE BELOW GRADE GR 1. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES AND GOVERNING AUTHORITIES. I.E.: FLORIDA BUILDING CODE 2017. 2. ALL SANITARY PIPING 2-1/2" OR LESS SHALL HAVE A 1/4" PER FOOT SLOPE. ALL SANITARY PIPING 3" OR LARGER SHALL HAVE A 1/8" PER FOOT SLOPE UNLESS OTHERWISE NOTED. ALL STORM WATER PIPING 2-1/2" OR LESS SHALL HAVE A 1/4" PER FOOT MINIMUM HORIZONTAL SLOPE. ALL STORM WATER PIPING 3" OR LARGER SHALL HAVE A 1/8" PER FOOT MINIMUM HORIZONTAL SLOPE UNLESS OTHERWISE INDICATED. 3. VALVES AND FITTINGS SHALL BE OF SAME SIZE OF LINE ON WHICH THEY ARE LOCATED, UNLESS OTHERWISE INDICATED ON DRAWINGS. 4. INSTALL WATER HAMMER SHOCK ARRESTORS AT EACH FIXTURE OR BATTERY OF FIXTURES WHERE REQUIRED. ARRESTORS SHALL BE FACTORY FABRICATED. INSTALL ARRESTORS AND SIZE PER PLUMBING AND DRAINAGE INSTITUTE STANDARD P.D.I. WH-201. ACCEPTABLE MANUFACTURERS: JOSAM, WATTS AND SIOUX CHIEF. AIR CHAMBERS SHALL NOT BE CONSIDERED AN EQUAL TO WATER ARRESTORS AS SPECIFIED. 5. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING FIRE RATING AND WEATHERPROOFING INTEGRITY OF ALL PIPING AND PENETRATIONS. 6. ALL WATER SUPPLY AND SANITARY LINES SHALL RUN AS CLOSE TO PLANS AS POSSIBLE WITH NO CHANGES IN SIZING. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY SUPPORTING DEVICES FOR FIXTURES. 8. CHANGES IN THE DIRECTION OF SANITARY AND STORM DRAINAGE PIPING SHALL NOT BE MADE WITH FITTINGS WHICH WILL CAUSE EXCESSIVE REDUCTION IN THE VELOCITY OF FLOW OR CREATE ANY OTHER ADVERSE EFFECT. I.E.: USE OF SANITARY TEE IN A HORIZONTAL CONNECTION, USE OF A DOUBLE SANITARY TEE IN A VERTICAL STACK, USE OF SHORT RADIUS FITTINGS FOR BRANCH TO HOUSE DRAIN OR STACK CONNECTION. 9. CONTRACTOR SHALL GIVE 24 HOURS NOTICE TO APPLICABLE UTILITY COMPANY PRIOR TO PERFORMING WORK INVOLVING UTILITIES. 10. ALL DRAINAGE PIPING SHALL BE MARKED WITH THE SEAL OF APPROVAL OF THE NATIONAL SANITATION FOUNDATION. 11. WHERE SANITARY SEWER LINES CROSS UNDERGROUND WATER SUPPLY LINES THE INSTALLATION SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2014 PLUMBING, ARTICLE 603.2.CONSTRUCTED OF DUCTILE IRON PIPE (10' EACH SIDE OF WATER MAIN) OR THE WATER LINES SHOULD BE MODIFIED TO PROVIDE 8" MINIMUM CLEARANCE. 12. ALL FLOOR DRAINS SHALL BE PROVIDED WITH A TRAP PRIMER VALVE AND FITTINGS UNLESS NOTED OTHERWISE. 13. THE PLUMBING CONTRACTOR MAY BE REQUIRED TO DROP PIPE OUTSIDE OF BUILDING TO REQUIRED DEPTH TO PROVIDE CONNECTION TO AREA DEVELOPMENT UTILITY STUB. ALL DROPS IN DEPTH SHALL BE MADE WITH THE USE OF 45° FITTINGS. 14. ROUTE ALL PIPING CONCEALED ABOVE CEILINGS, WITHIN WALLS, OR IN CHASES. EXPOSED PIPING SHALL BE SLOPED AND PAINTED TO MATCH ARCHITECTURAL FINISHES. PIPING IN MECHANICAL ROOMS MAY BE EXPOSED. 15. SLEEVE AND FIRE STOP ALL PENETRATIONS (IF ANY) OF RATED WALLS, FLOORS, CEILINGS, ETC., IN ACCORDANCE WITH APPLICABLE UL STANDARDS AND LOCAL CODES TO MAINTAIN RATINGS. REFER TO SPECIFICATIONS AND ARCHITECTURAL DRAWINGS FOR RATED WALLS, CEILINGS AND FLOOR INFORMATION. 16. ALL WATER PIPING INSTALLED IN EXTERIOR WALLS SHALL BE PLACED ON THE INTERIOR SIDE OF THE WALL.THE WALL INSULATION SHALL BE PLACED ON THE EXTERIOR SIDE OF THE PIPE. 17. SEE RISER DIAGRAMS FOR BRANCH PIPING DETAILS AND SIZES NOT SHOWN ON PLANS. 18. COLD AND HOT WATER PIPING SHALL BE FLOWGUARD GOLD CTS CPVC TYPE AND SHALL MEET ASTM D 2846 AND ASTM D 1784. DISINFECT WATER PIPING AFTER PRESSURE TEST WITH CHLORINE SOLUTION 50 MG-L) FOR 24 HOURS. FLUSH LINES CLEAN AFTER COMPLETION. 19. SOIL, WASTE AND VENT PIPING SHALL BE PVC: ASTM D2665 SCHEDULE 40. FITTINGS: PVC DWV JOINTS: ASTM WELD. PROVIDE CAST IRON PIPE AND FITTINGS FOR SOIL, WASTE AND VENT PIPING LOCATED IN CEILING PLENUMS. 20. PROVIDE CLEANOUTS AT BASE OF EACH VERTICAL STACK AT EACH CHANGE OF DIRECTION OF HORIZONTAL RUNS AND AT 100 FOOT INTERVALS OF HORIZONTAL RUNS FOR SANITARY AND STORM PIPING. 21. PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASES OR ABOVE NON-ACCESSIBLE CEILINGS. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. 22. METERING AND SITE UTILITY CONNECTIONS SHALL BE PROVIDED ON SITE UTILITY DRAWINGS. ALL SERVICES SHOWN ON THIS SET OF PLANS TERMINATE 5'-0" FROM BUILDING, UNLESS SHOWN OTHERWISE ON DRAWINGS. PLUMBING CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO SITE UTILITIES. 23. FURNISH AND INSTALL HOSE BIBBS AND/OR WALL HYDRANTS 24" ABOVE FINISHED GRADE/FLOOR AND PROVIDE VACUUM BREAKERS. 24. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF ROOF DRAINS, PLUMBING FIXTURE MOUNTING HEIGHTS AND DIMENSIONS. 25. CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF EXISTING SEWERS IN WHICH NEW SEWER LINES ARE TO BE CONNECTED PRIOR TO START OF CONSTRUCTION. 26. CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS AT CONNECTIONS OF DISSIMILAR METALS. 27. CONTRACTOR SHALL ROUGH-IN ALL WASTE AND SUPPLIES TO SPECIAL EQUIPMENT ACCORDING TO MANUFACTURER'S SHOP DRAWINGS AND MAKE FINAL CONNECTIONS. ALL SUPPLIES SHALL BE VALVED. INSTALL VACUUM BREAKERS WHERE REQUIRED BY CODE. 28. PROVIDE REDUCED PRESSURE BACKFLOW PREVENTERS FOR DOMESTIC WATER SUPPLY CONNECTIONS AS REQUIRED BY CODE. 29. ALL BELOW GRADE/SLAB PEX PIPING SHALL BE PLACED WITHIN POLYETHYLENE PLASTIC SLEEVING. EXTEND SLEEVING ABOVE GRADE/SLAB. 30. CONTRACTOR SHALL REFER TO PLUMBING DRAWINGS FOR EXACT LOCATIONS OF FLOOR DRAINS (IF ANY) LOCATED WITHIN TOILET ROOMS. 31. PRESSURE REDUCING VALVES SHALL BE INSTALLED ON BRANCH LINES SERVING FIXTURES AND/OR EQUIPMENT WHEN THE PRESSURE IN THE LINE EXCEEDS 80 P.S.I. 32. COORDINATE EXACT LOCATION OF FLOOR DRAINS FOR HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR. CONDENSATE PIPING SHALL NOT DISCHARGE INTO SANITARY SYSTEM. 33. ROUTE WATER LINES TIGHT TO STRUCTURE. COORDINATE ROUTING TO AVOID CONFLICTS WITH OTHER DISCIPLINES. 34. IF THE INTENT OF THE DRAWINGS AND/OR SPECIFICATIONS IS UNCLEAR OR HAS MORE THAN ONE INTERPRETATION, IT SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING BEFORE THE SUBMISSION OF BIDS. THE ARCHITECT/ENGINEER SHALL MAKE CORRECTIONS AND/OR PROVIDE EXPLANATION IN WRITING. 35. PLANS AND SPECIFICATIONS ARE INTENDED AS A GENERAL DESCRIPTION OF THE WORK TO BE PERFORMED. ALL ITEMS NOT SPECIFICALLY MENTIONED OR SHOWN, BUT NECESSARY FOR THE COMPLETION OF THE INSTALLATION, SHALL BE FURNISHED AND INSTALLED BY THIS CONTRACTOR. THE CONTRACTOR SHALL ACQUAINT HIMSELF WITH THE MECHANICAL, ARCHITECTURAL, STRUCTURAL AND ELECTRICAL PLANS PRIOR TO SUBMITTING HIS FINAL BID. NO ADDITIONAL COMPENSATION WILL BE ALLOWED DUE TO CONTRACTORS FAILURE TO FAMILIARIZE HIMSELF WITH THE PLANS. 36. THE CONTRACTOR SHALL BASE HIS PROPOSAL UPON THE EQUIPMENT AS SCHEDULED OR SPECIFIED, USING THE MANUFACTURERS AND EQUIPMENT SPECIFIED ON THE DRAWINGS. IF MORE THAN ONE MANUFACTURER IS SPECIFIED FOR ONE ITEM, ANY ONE OF THE MANUFACTURERS LISTED MAY BE USED IN THIS CONTRACTOR'S PROPOSAL. IF THIS CONTRACTOR WISHES TO USE EQUIPMENT NOT SPECIFIED, HE MUST AT THE TIME OF BIDDING SUBMIT SEPARATELY ON LETTERHEAD STATIONARY OF THE BIDDER, THE EQUIPMENT HE WOULD SUBSTITUTE AND THE COST TO BE ADDED OR TO BE DEDUCTED FROM HIS PROPOSAL. 37. THE CONTRACTOR IS EXPECTED TO ORDER ALL MATERIALS IN SUFFICIENT TIME TO AVOID DELAYING THE COMPLETION OF THE PROJECT. DELAY IN DELIVERY WILL NOT BE CONSIDERED A JUSTIFIABLE REASON FOR SUBMISSION OF SUBSTITUTE MATERIALS. 38. DO NOT PENETRATE WALL FOOTINGS WITH PIPING. COORDINATE WITH GENERAL CONTRACTOR TO DROP FOOTINGS AS REQUIRED TO CLEAR PLUMBING SERVICES WHERE ABSOLUTELY NECESSARY. ALL PIPING PENETRATING A BEARING WALL OR FOOTING MUST BE SLEEVED AND LOCATION APPROVED BY STRUCTURAL ENGINEER. 39. REFER TO PLANS FOR VENT THRU ROOF (VTR) PIPE SIZES AND LOCATIONS. LOCATE VTR A MIN. 10' HORIZONTAL FROM ANY BUILDING OPENING OR FRESH AIR INTAKE. EXTEND VTR 3' ABOVE ROOF SURFACE. IF 10' DISTANCE CANNOT BE ACHIEVED LOCATE VTR 3' ABOVE ADJACENT TOP OF FRESH AIR INTAKE OR BUILDING OPENINGS. PROVIDE 1" FIBERGLASS INSULATION WITH ALL-SERVICE JACKET ON VENT PIPE INSIDE BUILDING WITHIN 6' OF VTR LOCATION. VERIFY FLASHING AND COUNTERFLASHING AND COORDINATE INSTALLATION WITH ROOFING CONTRACTOR. 40. HEAT-TRACED PIPING SHALL MEET INSULATION THICKNESS REQUIREMENTS PER FLORIDA BUILDING CODE 2017 -ENERGY CONSERVATION. PLUMBING GENERAL NOTES FIXTURE SPECIFICATIONS TAG FIXTURE MANUFACTURER MODEL # PIPE SIZE DESCRIPTION CW HW SAN VENT SUPPLIED BY: NOTES: 1. REFER TO ARCHITECTURAL DRAWINGS FOR ALL FINAL LOCATIONS AND MOUNTING DIMENSIONS OF ALL PLUMBING FIXTURES. PROVIDE ADA CONFORMING FACTORY INSULATION KIT ON HOT, COLD AND P-TRAP WASTE PIPING AT HANDICAP DESIGNATED LAVATORIES. 2. SEE EQUIPMENT SCHEDULE ON SHEET EQ1 FOR EQUIPMENT NOT LISTED. 3. URINALS AND WATER CLOSETS SHALL COMPLY WITH ASME A112.19.2 4. FLOOR SINK AND FLOOR DRAIN RIMS SHALL BE FLUSH WITH THE FINISHED FLOOR, UNLESS SPECIFICALLY REQUIRED BY THE LOCAL AUTHORITY TO BE RAISED. FLOOR DRAINS IN RESTROOMS SHALL BE SET FLUSH WITH TOP OF CONCRETE SLAB ON GRADE. WATER CLOSET FLUSH VALVE ADA) AMERICAN STANDARD URINAL AMERICAN STANDARD 6561.017 LAVATORY UNDERMOUNT SINK ELKAY ELUH1811 W/ LKUCLIP WC-1 UR-1 LAV-1 LAVATORY WALL HUNG AMERICAN STANDARD 0355.012LAV-2 MOP RECEPTOR FIAT MSB-3624MR-1 ELECTRIC WATER HEATER BRADFORD WHITE M-II-50-15-3SFEWH-1 SINK COUNTERTOP -- MW5.4/ MW9.1 3 COMPARTMENT SINK -- HAND SINK KROWNE HS-30L SINK COUNTERTOPMW4 WALL CLEANOUT ZURNZ1446WCO FLOOR CLEANOUT ZURN CO-2450-PVFCO FLOOR DRAIN JAY R. SMITH 2005-AFD-1 FLOOR DRAIN JAY R. SMITH 2005-F37FD-3 FLOOR SINK PLASTIC ODDITIES RBH-300HFS-1 HUB DRAIN --HUB-1 HUB DRAIN --HUB-2 EXTERIOR CLEANOUT JAY R. SMITHECO SHOCK ARRESTOR WILKINS1250SA BOOSTER PUMP GRUNDFOS CMBE 3-51BP-1 AIR ADMITTANCE VALVE OATEY39016AAV ELECTRIC WATER COOLER ELKAY HI-LO EZSTL8LCEWC-1 ROOF DRAIN JAY R. SMITH1340TRD-1 PRIMARY ROOF DRAIN ZURN ZC-100RD-2 CALIBRATED BALANCE VALVE BELL & GOSSETT CB3/4LFBV-1 RECIRCULATING PUMP BELL & GOSSETT NBF-9F/LWRP-1 MIXING VALVE LAVATORIES) WATTS REGULATOR LFMMV-US-M1MX-1 WATTS REGULATOR LFMMV-US-M1MX-2 MIXING VALVE HAND WASHING) 1"-4"2" FLOOR MOUNTED ADA COMPLIANT, VITREOUS CHINA, 1.6 GPF, TOP SPUD, ELONGATED FLUSH VALVE WATER CLOSET. PROVIDE WITH MANUFACTURERS RECOMMENDED ANGLE SUPPLY STOPS, SLOAN "ROYAL OPTIMA" FLUSH VALVE MODEL 111 ES-S TOP SPUD WITH ACCESSORIES EL-154 & EL-226. PROVIDE WITH OLSONITE MODEL #95SSCT SEAT. 3/4"-2"1-1/2" TRIMBROOK 1.0 GPF SIPHON JET URINAL, ADA COMPLIANT FLUSHING RIM, VITREOUS CHINA URINAL. LOW CONSUMPTION AND SIPHON JET FLUSH ACTION. SLOAN "ROYAL OPTIMA" FLUSH VALVE MODEL 186-1 ES-S TOP SPUD WITH ACCESSORY EL-154 & EL-226. PROVIDE WITH RECOMMENDED K2 HANGERS. 1/2"1/2"2"1-1/2" ADA COMPLIANT UNDER MOUNT STAINLESS STEEL LAVATORY. INSTALL AS REQUIRED TO MEET ADA GUIDELINES. PROVIDE WITH MCGUIRE MODEL #H158LK, #155A, & #8902. PROVIDE ZURN FAUCET MODEL #Z6915-GEN WITH THESE OPTIONS 0.5 GPM VANDAL RESISTANT LAMINAR FLOW & LOW LEAD COMPLIANT. PROVIDE WITH MIXING VALVE WATTS MODEL #LFMMV-US-M1. INSTALL USING MANUFACTURERS RECOMMENDATIONS. USE OFFSET TAILPIECE TO AVOID CONFLICT WITH CABINET DOOR. 1/2"1/2"2"1-1/2" ADA COMPLIANT WALL HUNG VITREOUS LAVATORY. INSTALL AS REQUIRED TO MEET ADA GUIDELINES. PROVIDE WITH MCGUIRE MODEL #H158LK, #155A, & #8902. PROVIDE ZURN FAUCET MODEL #Z6915-GEN WITH THESE OPTIONS 0.5 GPM VANDAL RESISTANT LAMINAR FLOW & LOW LEAD COMPLIANT. PROVIDE LAV SHIELD TRUEBRO MODEL #2018-AS-L. PROVIDE WITH MIXING VALVE WATTS MODEL #LFMMV-US-M1. INSTALL USING MANUFACTURERS RECOMMENDATIONS. 3/4"3/4"3"1-1/2" FLOOR MOUNTED MOLDED PLASTIC BASIN WITH HOSE BRACKET 832-AA, WALL MOUNTED FAUCET 830-AA, MOP HANGER 889-CC AND CORNER GUARD ON THE FRONT LIP. 1-1/4"--- 50 GALLON "VITRAGLAS" LINED STEEL TANK, MAGNESIUM ANODE ROD AND NON-CFC FOAM INSULATION BETWEEN OUTER STEEL JACKET. SURFACE MOUNTED THERMOSTAT AND SCREW IN STYLE INCOLOY SHEATHED HEATING ELEMENTS, 15 KW, 208V, 3PH., SET OUTLET TEMPERATURE AT 140 °F. WATER HEATER ON 4" CONCRETE CURB WITH QP-26 DRAIN PAN. PROVIDE THERMAL EXPANSION TANK MAINLINE MLT5. 1/2"1/2"2"1-1/2"FURNISHED BY WAWA, INSTALLED BY PLUMBING CONTRACTOR. REFERENCE DETAIL 14 THIS SHEET FOR MW5.4 & MW9.1. 3/4"3/4"--FURNISHED BY WAWA, INSTALLED BY PLUMBING CONTRACTOR. 1/2"1/2"2"1-1/2" WALL MOUNTED, S/S HAND SINK WITH FAUCET & STRAINER, CHROME PLATED BRASS ANGLE STOPS WITH CHROME PLATED RISERS AND CHROME PLATED ESCUTCHEONS; CHROME PLATED BRASS TAILPIECE & TRAP(PVC NOT PERMITTED). FAUCET HANDLES SHALL BE ALIGNED TO BE PERPENDICULAR TO THE FLOOR WHEN IN THE CLOSED POSITION. PROVIDE MIXING VALVE WATTS MODEL #LFMMV-US-M1. MIXING VALVE SHALL BE LOCATED ABOVE THE "LAY-IN" CEILING TILE WHERE APPLICABLE. TEMPERATURE GAUGE SHALL BE EASILY READABLE FROM THE FLOOR OR A LADDER. TEMPERED WATER SHALL BE SET AT 120°F. 1/2"1/2"2"1-1/2"FURNISHED BY WAWA, INSTALLED BY PLUMBING CONTRACTOR. WALL CLEANOUT WITH STAINLESS STEEL ROUND ACCESS COVER. SEE PLANS FOR PIPE SIZE CONNECTION. FLOOR CLEANOUT WITH ACCESS COVER. SEE PLANS FOR PIPE SIZE CONNECTION. 3"1-1/2" CAST IRON BODY WITH BOTTOM OUTLET, NICKEL BRONZE ROUND STRAINER. PROVIDE DEEP SEAL TRAP (2005L-A05-NB) AND PROVENT SYSTEMS TRAP GUARD MODEL TG3H. IN RESTROOMS TOP OF FD-1 STRAINER HEAD SHALL BE SET FLUSH WITH TOP OF CONCRETE SLAB ON GRADE. 3"1-1/2" CAST IRON BODY WITH BOTTOM OUTLET, NICKEL BRONZE ROUND STRAINER WITH FUNNEL. PROVIDE DEEP SEAL (2005L-F37-NB) TRAP AND PROVENT SYSTEMS TRAP GUARD MODEL TG3H. IN WATER SERVICE ROOM OR EXTERNAL CLOSET TOP OF FD-3 FUNNEL/EXTENDED RIM TO BE FLUSH WITH FINISHED FLOOR (TERRAZO). SEE PLANS - 12"Ø x 5.5" DEEP, PLASTIC BODY WITH ACID RESISTING INTERIOR AND HALF PLASTIC GRATE TOP. 3"-3" X 6" INCREASER FITTING. TOP OF FITTING SET @ 1" A.F.F. PROVIDE WITH 3" SNAP-IN STRAINER. SEE HUB DRAIN DETAIL THIS SHEET. 3"-TOP OF FITTING SET @ 1" A.F.F. PROVIDE WITH 3" SNAP-IN STRAINER. HEAVY TRAFFIC AREA EXTERIOR CLEANOUT WITH ACCESS COVER AND TWO-WAY FITTING. SEE PLANS FOR PIPE SIZE CONNECTION. SHOCK ARRESTOR SHALL MEET ASSE 1010. THE DEVICE SHALL CONSIST OF A COPPER BODY WITH AN ACETAL PISTON, BUNA NITRILE O-RINGS AND LEAD FREE SOLDER. THE DEVICE SHALL BE PRE-CHARGED AND SEALED AT THE FACTORY. PROVIDE WITH WALL MOUNTED CONTROLLER, DIAPHRAGM TANK, PRESSURE SENSORS AND ANY OTHER MANUFACTURER REQUIREMENTS. 1 HP, 115V 20 DFU, SURE-VENT AIR ADMITTANCE VALVE WITH 1-½" X 2" PVC SCHEDULE 40 ADAPTER. INSTALL PER MANUFACTURERS REQUIREMENTS. 1/2"-2"1-1/2" BARRIER FREE ADA COMPLIANT ELECTRIC WATER COOLER. COORDINATE POWER OUTLET LOCATION WITH ELECTRICAL CONTRACTOR FOR ELECTRICAL CORD WITH 3-PRONG PLUG. INSTALL PER MANUFACTURERS RECOMMENDATIONS. REFER TO ARCHITECTURAL ELEVATION VIEWS FOR MOUNTING HEIGHTS. DUCO CAST IRON BODY WITH COMBINED FLASHING CLAMP & GRAVEL STOP WITH POLYETHYLENE DOME AND EXTENSION SLEEVE AS REQUIRED. PIPE SIZE 2". MAIN ROOF DRAIN, COATED CAST IRON BODY WITH CAST IRON DOME STRAINER. PIPE SIZE = 6" FURNISH AND INSTALL AS SHOWN ON PLANS AND WITH MANUFACTURERS RECOMMENDATIONS MODEL CB CALIBRATED BALANCE VALVES. PROVIDE WITH MODEL AQS-3/4 AQUASTAT. PROVIDE ELECTRICAL DISCONNECT SWITCH. ELECTRICAL REQUIREMENTS ARE 115v/1/60hz. CAPACITY FOR PUMP IS 5 GPM AT 5 FT HEAD. 1/2"1/2"--ASSE 1070 MIXING VALVE SET AT 110ºF (UNLESS NOTED). 1/2"1/2"--ASSE 1070 MIXING VALVE SET AT 120ºF (UNLESS NOTED). FLOOR SINK PLASTIC ODDITIES RBH-300TFS-5 -- SEE PLANS - 12"Ø x 5.5" DEEP, PLASTIC BODY WITH ACID RESISTING INTERIOR AND THREE-QUARTER PLASTIC GRATE TOP. PC HJC PC HJC HJC HJC WAWA HJC HJC HJC HJC HJC HJC PC PC CABINET CABINET CABINET HJC HJC HJC HJC HJC HJC HJC HJC HJC HJC HJC JAY R. SMITHWALLHYDRANT 5509QT-SAP-RBWCH 3/4"--- PROVIDE WALL HYDRANTS AS LOCATED ON THE PLUMBING DRAWINGS. WALL HYDRANTS SHALL BE AUTOMATIC DRAINING WITH 3/4 INCH VACUUM BREAKER HOSE CONNECTION. COLD WATER SUPPLY SHALL BE PROVIDED WITH A BACKFLOW PREVENTER AS INDICATED ON THE PLUMBING DRAWINGS. HJC 4313 3461.001 F5 F3 CABINET FRONT H&CW SUPPLIES SINK LOCATE ALL WATER PIPING IN THIS CABINET ONLY NOTES: 1. REFER TO WATER SERVICE RISER DIAGRAM AND CSR SYSTEM ELEVATION FOR ADDITIONAL INFORMATION. 2. INSTALL T&S BRASS B-2585-WAWA SINGLE HOLE TEMPERATURE DECK MOUNT FAUCET FOR COLD BREW. QUARTER TURN 2.2 GPM AERATOR LEVER HANDLE AND 1/2" NPSM MALE INLET. SUPPLIED BY WAWA INSTALLED BY PLUMBING CONTRACTOR.) 1) CSR FOR COLD BREW SUPPLIES SET PIPING TIGHT PARALLEL TO SIDE PANEL 2' - 0"TRAP GUARD DRAIN INSERT PROTECTION MANUFACTURER = PROVENT SYSTEMS PART NO. TG3H 3" INSERT FITS INSIDE 3" GASKETED PVC, ABS OR CAST IRON PIPE IMPORTANT INSTALLATION NOTES:1. REMOVE THE STRAINER OFF THE TOP OF THE FLOOR DRAIN TAILPIECE 2. MAKE SURE THE INSIDE OF THE TAILPIECE IS CLEAN BEFORE INSERTING THE TG3H TRAP GUARD 3. IT MAY BE NECESSARY TO USE A LUBRICANT ON THE OUTSIDE OF THE BUSHING FOR AN EASIER INSERTION 4. THE TAPPER ON THE TOP OF THE TG3H BUSHING FLANGE SHOULD FIT FLUSH WITH THE TAPPER IN THE TOP OF THE TAILPIECE SO THE TRAP GUARD INSERT IS NOT INSTALLED ABOVE THE TAPPER IN THE DRAIN OPENING. FLOOR SINK 2" AIR GAP FROM END OF PIPE TO FLOOR SINK THREE- COMPARTMENT SINK CUT PIPE AT 45° EWH- 1 HW SUPPLY CW SUPPLY H WR SUPPLY RECIRCULATION PUMP (RP- 1)HOT WATER RECIRCULATION COPPER PIPE GATE VALVE ( TYP)ASME TEMP. & PRESSURE RELIEF VALVE TANK DRAIN VALVE 1-1/ 2" HIGH GALVANIZED STEEL DRAIN PAN WATER HEATER ON 4" CONCRETE CURB PIPE TO FD-1 ACCESS DOOR THERMOMETER VACUUM RELIEF VALVE CHECK VALVE UNION (TYP) THERMAL EXPANSION TANK 4" DRAIN FROM FIXTURE 3" WASTE PIPE MINIMUM)FLOOR SINK LC 1'-4"2'-2" 2'-10 1/2"3'-0" 10 1/2"1'- 8"2 3/ 4"4 3/ 4"2'-3 1/2"NOTE: ALL ADJUSTMENTS MUST BE MADE PRIOR TO SLAB POUR. ADJUST FCO FLUSH WITH FINISHED FLOOR ELEVATION. GRINDING OR OTHERWISE ALTERING TOP OF FCO IS NOT PERMITTED CONC. SLAB ON GRADE TERRAZZO ( T1) OR URETHANE CEMENT FLOOR ( EF-1)FINISHED FLOOR)PVC BODY ADJUSTABLE FLOOR CLEAN OUT ABS PLUG 3/8" Ø ALL THREAD ROD ADJUSTABLE SWIVEL PIPE HANGER RING BAR JOIST C-CLAMP PIPE HANGER FOR TOP ANGLE HUB DRAIN FLOOR 2'-4" NOTE: PROVIDE UNIONS IN INDIRECT WASTE PIPING TO ALLOW FOR REFRIGERATION EQUIPMENT REMOVAL. PIPE IW SEPARATELY FOR EACH UNIT.LOCATE PIPE TIGHT TO REAR CABINET PANEL 2" AIR GAP FLOOR ADJACENT WALL OR CABINET NOTE: REFER TO WATER SERVICE WATER RISER DIAGRAM FOR ADDITIONAL INFORMATION.29" CABINET BOTTOM 3/ 4" CSRX WATER SUPPLY TO (2)EQ B26.3, B29.1, & FUTURE B26. 3 LOCATE OUTLETS AND PIPING TIGHT TO THE UNDERSIDE OF THE COUNTER TOP SANITIZING SYSTEM CONTROL PANEL AND HOSE, PROVIDED BY OTHERS.3/4" THREADED HOSE CONNECTION 2" GAP BETWEEN DRAINBOARD AND WALL 1/2" COPPER TUBING PROPERLY SECURED TO WALL 1/ 2" BFP WATTS SERIES #009QT MX-2 (1/ 2") MIXING VALVE WATTS SERIES MMV-1/2" SET @ 90° F 3/4" H&CW FROM WALL BALL VALVES (TYP)3/4" H&CW SUPPLIES TO FAUCET NOTES:1. LABEL ALL VALVES WITH A PERMANENT TAG. 2. ALL VALVES MUST BE EASILY ACCESSIBLE HOT OR COLD WATER MAIN RUN @ UNDERSIDE OF TRUSS BRANCH LINE TAKE-OFF,LOCATE VALVE ACCESSIBLE IN VERTICAL DROP, 12" ABOVE CEILING.BRANCH LINE TO FIXTURE SHALL BE RUN 12"(+/-) ABOVE TOILET ROOM CLG.NOTES:1. THE INTENT OF THIS ELEVATION IS TO SHOW THE CSR" WATER EQUIPMENT, OUTLET LOCATIONS, PIPING CONFIGURATION, AND GENERAL CSR WATER ARRANGEMENT. FOR ADDITIONAL INFORMATION, PIPE SIZES, BACKFLOW PREVENTER TYPES, NOTES, ETC., REFER TO THE WATER RISER DIAGRAM AND EQUIPMENT SCHEDULES.2. ALL CSR VALVES SHOULD HAVE IDENTIFICATION TAGS.7'-10" T CHK BFPSR- X9'-0" MIN.12" 29"EQ. B42.29'- 0"TO B. O. CSR UNIT202 PRE- FILTER DUAL SYSTEM MC FILTER CART. MC FILTER CART. MC FILTER CART. MC FILTER CART. E20 PRE- FILTEREQ. C23EQ. C28EQ. C21EQ. C28( ROUTE IN WALL)( ROUTE IN WALL)( ROUTE IN WALL) EQ. B37. 1ACTIVATION DRAIN VALVE EQ. B29.1EQ. B26.3EQ. B26. 3EQ. B37.1EQ. B40BALL VALVE ( TYPICAL)BACKFLOW PREVENTER ( TYP) PRESSURE SENSOR & PRESSURE GAUGE. BAS INTERFACE 1" CW SUPPLY EXPRESS LINE BACK FLOW PREVENTER 1" FLEX-TUBING TO SURGE TANK, W/ QUICK-DISCONNECT CHECK VALVE 3-WAY BALL VALVE SURGE TANK EQ. C22EQ. C22SEE FREESTYLEDETAIL P2 SHEET.(ROUTE IN WALL) COLD BREWEQ. B26. 3 (FUTURE)FLOOR COFFEE ANDSMOOTHIE SINKS INDIRECT CONNECTION BY AIR BREAK. 45DEGREE ANGLE CUT. ENSURE ALL EFFORTS AREMADE TO ELIMINATE SPLASHING FLOOR SINK LOCATE ALL WATERPIPING IN THIS CABINET ONLY STAINLESS STEELWALL STAINLESS STEEL WALL 1- 1/2" DIAMETER FLOOR SINK SPEC: PLASTIC ODDITIES RBH300T ( FS-5)SET FLUSH.3/4 COVER GRATE 1" BELOW TOP1 1/2"ø COPPER PIPE 3"X6" INCREASER WITH 3" SNAP- IN STRAINER. INSTALL TOP OF HUB 1" ABOVE FINISH FLOOR (FORRECEIVING CONDENSATE ONLY).FINISHED FLOOR PROVIDE DEEP SEAL P-TRAP ONLY IF CONNECTED TO SANITARY SEWER SHEET TITLECLIENTNAMEPROJECT NAMECHECKEDDRAWNDATEPROJECT NO.COPYRIGHT © -All reports, plans, specifications, computer files, field data, notes and other documents areinstruments of service preparedby: Cuhaci &