Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5380-F85FB-v20.0 - Sheet - E1 - ELECTRICAL POWER PLAN
J IGJ J J M J J J J J J MJ J J J J J L L L L L L L L L L L L L J J M MMJ J J J L L J L L E6 1 J J RETAIL AREA RE:SHEET E4 FOR UNDER SLAB CONDUIT LAYOUT 2 -OUTLET BOXES ON WALL. 36" RTE, MUSIC. 34" 34" 34" 34" 1-OUTLET BOX STACKED ABOVE 36" HIGH OUTLET BOX AT 80" GFI MOUNT THESE (2) RECPTACLES IN CABINET 34" 34" TF FREESTYLE BOOST PUMP PORTABLE GENERATOR CONNECTION BOX. IG 31 30 31 30 FAN COILS FAN COILS DOOR HEAT #1 R 58" 11 FUEL TANK MONITOR10 14 16 26 4 26 18 26 13 7 12 WP GFI WP GFI 30 WP GFI WP GFI 16 16 35 9 8 D S GASOLINE EMERGENCY SHUTOFF 11 48" HAND DRYER L6-15R RPC-7 34" ASSOCIATE VESTIBULE OFFICE LIGHTS FANS DANFOSS CONTROLLER WATER HEATER MDP-31,33,35 NEMA 3R CIRCULATION PUMP 25 28 27 21 HAND DRYER HAND DRYER 31 48" 100" BAS PANEL 15 30 72" RPD-3 34" 34" UPS UPS IG FIRE ALARM PANEL RPU-12 RPC-32 84" OVER DOOR AIR CURTAIN WP GFI 16 43" RETAIL AREA SEE SHEET E4 FOR UNDER SLAB CONDUIT LAYOUT J 26 26 26 E7 1 INTENDED FOR 2ND ICE MERCHANDISER T T 84" DISPLAY LIGHTS 72" IG BELL/BUZZ RADIOCHARGERDOOR CHIMES RPU-13 SECURITY PANEL RPU-6 OVER DOOR AIR CURTAIN 30 WP 39 30 DOOR HEAT 22 24 24 37 37 37 GASOLINE EMERGENCY SHUTOFF 11 E7 1 17 INCOMING WATER BOOSTER PUMP C 30 WALK-IN DOOR/WINDOW HEAT 23 PRINTER 34" 30 DOOR HEAT #2 WP CP 5 CONDENSATION PUMP WP WP GFI 16 GFI 24" ELECTRIC WATER COOLER WP GFI 16 23 TF 4040 54"37 WP GFI GFI L15-30R PLUG FURNISHED WITH UNIT. STACK VERTICALLY@ 19" & 54" L15-30R,TW 43 CUSTOMER ACCESS TERMINALS 2)QUAD RECEPTACLES WITHIN CAB. @ 29"A.F.F. (TYP) SURFACE MOUNT 18" ABOVE OUTPUT SIDE OF BOOSTER PUMP FOR BAS CONNECTION TO PRESSURE SENSOR WITH CONDUIT TO ABOVE CEILING. 30 26 34 26 26 GFI GFI 55" 70" 48" J USB NOTE: COORDINATE RECEPTACLE WITH CABINETRY DRAWINGS. RPB -9RPB -9 26 84" CONTROL FROM SWITCH FOR SELF-SERV COOLER LIGHTS SEE SHEET E2) 55", IG, GFI IG PROVIDE CONDUIT TO ABOVE CEILING FOR JUNCTION BOX AT CO2 TANK 48". RPC-12 24" EF-2 ABOVE CEILING RPC -3 RPC -3 RPC -3 RPC -3RPC -3 RPC -3 RPC -1 RPC -1 RPC -1 RPC -1 RPC -27 RPB -23 RPA -8 RPC -10 RPB -42 LPA -5 RPC -3 RPB -7 RPC -4RPC -30 RPC -4 RPU -11 RPC -4 RPC -4 RPU -11 RPU -11 RPU -11 RPU -8 RPU -6 RPC -32 RPC -18 RPC -4 RPU -7 RPC -28 RPA -10 RPU -7 LPA -20 RPC -2 RPC -2 RPC -28 RPU -5RPU -5 RPC -28 RPH -15 RPC -2 RPC -2 RPA -3 RPC -10 RPC -10RPU -1 RPU -3 RPD -4RPC -34 RPA - 8 RPC - 16 RPC - 16 RPC - 17 RPB - 19 RPB - 21 LPA - 14 RPB - 34 RPB -25 RPB - 27 RPB - 29 RPB -28, 30 RPC - 3 RPC - 15 78" STAGING WATER SERVICE ROOM STACK SENSORS ON WALL COORDINATE WITH ARCHITECTURAL AND MECHANICAL DRAWINGS.TYP OF 2 RPC -29, 31 RPC -33, 35 RPC -8 RPC - 8 RPC - 8 RPC - 6 RPC -6 RPC - 6 RPA - 33 RPC -29, 31 RPC - 3 30"RPA - 31 33 30"RPA - 33 46 L6- 15R WP 46 RPC -21, 23 2 MOUNT BUG LIGHT 66" DIRECTLY OVER RECEPTACLE SO CORD DOES NOT SHOW. MOUNT RECEPTACLE HORIZONTALLY MOUNT BUG LIGHT 66" DIRECTLY OVER RECEPTACLE SO CORD DOES NOT SHOW. MOUNT RECEPTACLE HORIZONTALLY WHILE IN-USE SINGLE GANG WEATHERPROOF COVER & HUBBELL SWITCH MODEL #HBL1221PL FOR ABOVE CEILING VENTILATION SHUTOFF SWITCH. THE VENTILATION SWITCH SHALL BE LABELED WITH THE FOLLOWING: WARNING CO2 VENTILATION SYSTEM EMERGENCY SHUTOFF.RPB - 9 84"48" 48" A1 A1 C2C2 C15. 1 C6. 2 C11 RPC - 12 CO2 CENTRAL DISPLAY 60"RPB - 5 RPB - 1 RPB - 3 RPB -33, 35 RPB - 31 LPA - 16 RPB - 2 RPB - 8 RPB - 6 RPB - 11 RPB -10, 12 72" 37 4 82" CO2 SENSOR/ALARM DATA.CO2 SENSOR/ALARM DATA. 36 54"RPH - 17 C6. 2 FUTURE RPC -28 26 GFI RPC - 14 WP IRRIGATION CONTROLLER 48"RPA - 35 55" 55"RPC - 3 48" C2 C2 L14-30R, 208V J RPC - 10 RPD - 1RPD -426 44 C17. 3 C17. 3 45 45 RPC - 6 B29. 1 B29. 1 B30. 1 B26. 3 B26. 3 B30. 1 B49 B49 B41 B36 B36 B37. 1 B30. 1 B40 B44 B46 B9.1 MW2 B14. 2 B1. 2 B14. 2B14.2 B1.2B1. 2 B14. 2 B14. 2 C6. 2 B1. 1B14.2 B44B12. 2 B45 B32 B24 B30.2 B32 RPC - 2 RPB - 20 RPB -18 26 RPH -14, 16 RPH - 12 45 45 MOUNT THESE (5) RECPTACLES IN CABINET 24"24" 48" 48" 18" 38" 38" 24"24" 38"RPA- 26 RPH- 5 RPH- 3 RPA- 24 RPB- 15 TW 1 1 1 1 RPA-34,36 RPA-16,18 RPA-20,22 RPA-21,23 RPA-30,32 RPH-2, 4 RPU- 18 IG, 31"L6- 30R L6-30R PLUG FURNISHED WITH UNIT, INSTALLED BY E.C. INSTALL RECEPTACLE WHERE THE UNIT CAN BE PUSHED BACK AGAINST THE CABINET.PLUG FURNISHED WITH UNIT, INSTALLED BY E.C. INSTALL RECEPTACLE WHERE THE UNIT CAN BE PUSHED BACK AGAINST THE WALL. CUSTOMER ACCESS TERMINALS 2) QUAD RECEPTACLES WITHIN CAB. @ 29"A. F.F. (TYP) 30"30" 30"RPU- 16 24", IG RPU- 16 24", IG 3" TW 24"TW24" RPA-6RPA- 2 L6- 30R L6- 30R RPH- 6 RPU- 16 24" IG 2626 26 L6- 30R TW 24"RPA- 1 48" 41 RPA- 1 41 48" RPA-28 5 L15-30R RPA- 5, 7,9 29 PLUG FURNISHED WITH UNIT, INSTALLED BY E.C. INSTALL RECEPTACLE WHERE THE UNIT CAN BE PUSHED BACK AGAINST THE WALL.. TW 24" 30"L6-30R L5- 20R L5- 20R L5- 20R L5-20R RPA- 38,40,42 RPB- 37,39, 41 RPH- 8 24" GFI" RPA-1 4148"RPA- 4 24"GFI"L15- 30R L15-30P 51"L15- 50R L15-50P RPA- 25, 27, 29 LIGHTS FANS DANFOSS CONTROLLER C19. 1 C19. 1 C19. 1 A4 A4 A3 A3 30 A4 A3 RPB- 13 RPB-14 WALK-IN FREEZER WALK-IN REFRIG.FOOD SERVICE FOOD SERVICE COFFEE RETAIL AREA SELF SERVICE WALK-IN REFRIG.DELIVERY VESTIBULE RETAIL WALK-IN REFRIG.FOOD SERVICE MEN'S RESTROOM WOMEN'S RESTROOM REAR VESTIBULE WP CP 5 CONDENSATION PUMP 30 30 DOOR HEAT DOOR HEAT C11 30" 30" 30"30" A2 HAND DRYER RPC - 33, 35 C28 C22C22 C28 C23FAN COILS 31A1RPB - 1 L6- 30R WP GFI 16 RPC - 1 WP GFI RPB- 7 RPH - 19 RPH -21 RPA - 37,39, 41 LPA - 6 RPH -18 RPH -20, 22FAN COILS 31RPB -1 RPC -34RPC -30RPU -2 RPU - 2 RPU - 4 RPU - 4 GFI 100"RPC - 16 GFI RPC - 21,23 RPA - 11,13 RPA -15, 17 RPB - 17 RPB -4 RPH - 10 RPH - 7, 9,11 B15 20 FUTURE C6. 2 A2 26 RPH- 23 C20 C20 48" 48"RPB- 32RPB- 32 RPU- 16 24", IG26 RPU- 18 IG,31"GENERAL NOTES:1. E.C. TO LABEL EACH RECEPTACLE AND EXHAUST FAN SWITCH WITH CIRCUIT NUMBER AND INTENDED USE.2. ALL PHONE LINES TO BE GROUNDED. PROVIDE 120V SERVICE W/ ISOLATED GROUND RECEPTACLE AND SINGLE POINT GROUNDING FOR D.E.C./ S.A.S.I. EQUIPMENT.3. ALL BELLS SHALL BE 2-TONE. TRASH DOOR BELL SHALL BE DIFFERENT FROM DELIVERY DOORS. RE: SECURITY PLAN.4. ALL OUTLETS & SWITCHES IN THE BUILDING AND CLOSET AREAS SHALL BE LABELED WITH PANEL & CIRCUIT NUMBERS. RECEPTACLES AT COFFEE STEP UP COUNTER & FOOD SERVICE COUNTER SHALL ALSO BE LABELED TO IDENTIFY EQUIPMENT SERVED. A PROFESSIONAL LABEL MAKER SHALL BE UTILIZED FOR ALL LABELS. RE: DETAIL THIS SHEET.5. BELLS, BUZZERS, DELIVERY DOOR RELEASE, & ALL ASSOCIATED PUSH BUTTONS, SWITCHES, & WIRING ARE TO BE PROVIDED BY ALARM SYSTEM CONTRACTOR. 6. ALL RECEPTACLES FED FROM PANEL "RPU" SHALL BE ORANGE IN COLOR AND ISOLATED GROUND TYPE RECEPTACLES. HUBBELL #IG5362GY OR APPROVED EQUAL. 7. ALL RECEPTACLES FED FROM PANEL "RPD" SHALL BE ORANGE IN COLOR AND ISOLATED GROUND TYPE RECEPTACLES. HUBBELL #IG5362 OR APPROVED EQUAL. 8. ALL GFI RECEPTACLES SHALL BE DUPLEX RECEPTACLES U.N.O. WITH LED INDICATOR LIGHT. LEVITON #6898-W OR APPROVED EQUAL. NO FEED THRU PROTECTION PERMITTED.9. ALL 120 VOLT, 15 OR 20 AMP RECEPTACLES IN THE FOOD SERVICE AREA SHALL BE GFI TYPE. PROVIDE WEATHERPROOF WITH "WHILE IN USE" COVERS WERE INDICATED (WP).10. DATA/TELEPHONE RECEPTACLES INDICATED ON THIS DRAWING FOR REFERENCE ONLY. REFER TO E4 & E10 FOR INSTALLATION DETAILS.11. ALL RECEPTACLES SHALL BE MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED.12. LIGHTING AND POWER BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM #12 AWG UNLESS NOTED OTHERWISE IN PANEL SCHEDULES OR ON PLANS.13. THESE ELECTRICAL PLANS HAVE BEEN DESIGNED AND THIS PROJECT IS TO BE CONSTRUCTED IN ACCORDANCE WITH THE 2014 VERSION OF THE NATIONAL ELCTRICAL CODE.14. RE: DETAIL 3 THIS SHEET FOR ELECTRICAL WORK REQUIRED AT REMOTE TRASH COMPOUND. RE: CIVIL DRAWINGS FOR COMPOUND LOCATION.15. ALL FINAL CONNECTIONS TO THE REFRIGERATION DOOR HEATERS AND REFRIGERATION LIGHTS ARE THE RESPONSABILITY OF THE GC.16. RECEPTACLES OF 15 AND 20 AMPS, 120 AND 208 VOLTS INSTALLED IN WET LOCATION SHALL HAVE AN "IN USE" ENCLOSURE THAT IS WEATHERPROOF WHETHER OR NOT A CORD/ PLUG IS INSERTED. OUTLET BOX HOOD INSTALLED FOR THIS PURPOSE SHALL BE LISTED AND IDENTIFIED AS "EXTRA DUTY".KEYNOTES:1. SELF-TEST/RESET BLANK FACE GFI OUTLET TO BE INSTALLED ABOVE COUNTER TO ALLOW EASY RESET OF GFCI OUTLET.2. ELECTRICAL CONTRACTOR SHALL INSTALL (1) 2"X4" BACKBOX AT 48" WITH CONDUIT AND PULL STRING TO ABOVE CEILING FOR TELEPHONE LANDLINE. PROVIDE CLEAR, PERMANENT LABEL AT THIS PHONE STATING 911 EMERGENCY USE ONLY".3. NOT USED.4. NO RECEPTACLES SHALL BE INSTALLED IN ELECTRIC SAFE AREA. ALL WIRING IN CHECKOUT AREA TO BE MC CABLE AND INSTALLED WITHIN PANDUIT, SUPPLIED BY OTHERS.5. THIS RECEPTACLE SHALL BE WEATHERPROOF(WP). PROVIDE "WHILE IN USED" COVER.6. NOT USED 7. FOR EXACT LOCATION OF ALL DEVICES IN MANAGER'S OFFICE, RE: ARCHITECTURAL INTERIOR ELEVATIONS SHEET.8. FOR EXACT LOCATION OF ALL DEVICES IN ELECTRICAL ROOM, RE: ARCHITECTURAL DRAWINGS AND E6.9. E.C. SHALL INSTALL (1) 2"X4" BACK BOX FOR DATA OUTLET AT 42" AFF FOR THE TIME CLOCK. INSTALL CONDUIT AND PULL STRING TO ABOVE CEILING FROM DATA J-BOX. 10. FUEL TANKS MONITOR PANEL PROVIDED BY PETROLEUM CONTRACTOR.11. E.C. SHALL FURNISH AND INSTALL ALL NECESSARY EMERGENCY STOP AND E- STOP RE-SET BUTTONS. AN E-STOP SHALL BE LOCATED IN THE CHECKOUT AND ONE ON THE BUILDING EXTERIOR. CONFIRM EXACT REQUIREMENTS WITH LOCAL A.H.J.12. E.C. SHALL PROVIDE 120V FEED TO FLUSH VALVE TRANSFORMERS MOUNTED TO WALL ABOVE CEILING. PROVIDE TERMINATIONS FOR ALL FLUSH VALVE WIRING ROUTED TO TRANSFORMERS. E.C. TO PROVIDE ANY REQUIRED BACK BOXES AND CONDUIT. WIRING FROM TRANSFORMERS TO VALVES BY PLUMBING CONTRACTOR.13. PROVIDE PRINTER RECEPTACLE AND DATA OUTLET IN A COMMON 2-GANG BOX WITH DIVIDER. PROVIDE A SUITABLE 2- GANG COVER PLATE FOR DEVICES.14. FOOD SERVICE/COFFEE BACKWALL RECEPTACLES LOCATED ABOVE COUNTER, DUPLEX GFI OR SIMPLEX, SHALL BE PROVIDED WITH STAINLESS STEEL COVER PLATES AND SHALL BE MOUNTED IN HORIZONTAL POSITION.15. WIF CONDENSATE HEAT TRACE WILL BE 220V FED OFF FAN COIL CIRCUIT BY REFRIGERATION CONTRACTOR. 16. E.C. TO PROVIDE DUPLEX GFI RECEPTACLES WITH RED DOT CODE KEEPER FLUSH MOUNTED ZINC WEATHERPROOF COVER. NO FEED THRU PROTECTION PERMITTED.17. MOUNT THE GASOLINE EMERGENCY SHUT-OFF PUSH BUTTON 2" BACK FROM FACE OF CABINET. MOUNT UNDER COUNTER TOP.18. E.C. SHALL INSTALL AN ISOLATED GROUND (IG) DUPLEX RECEPTACLE IN SINGLE-GANG BOX. CENTER RECEPTACLES FOR ATM BEHIND MACHINE 19. NOT USED.20. DATA OUTLET BOX AND 20A SIMPLEX RECEPTACLE DEDICATED TO PRICE SIGN CONTROLLER E.C. TO COORDINATE INSTALLATION WITH SIGN CONTRACTOR.21. PROVIDE (2) L5-30R RECEPTACLES FOR COMPUTER RACK PDU, MOUNTED AT 18" AFF.22. NOT USED.23. RECEPTACLE TO BE LOCATED BEHIND MONITOR OR SIGNAGE. SEE SHEET G1 FOR EQUIPMENT LOCATION AND MOUNTING HEIGHT. CONCEAL POWER AND DATA CORDS BEHIND EQUIPMENT.24. EC TO PROVIDE BACK BOX, CONDUIT AND PULL STRING FOR FIRE SECURITY SYSTEM. RE: SHEETS E8 AND E9 FOR MORE INFORMATION..25. INSTALL #8 AWG GREEN INSULATED COPPER GROUND WIRE. CONNECT TO MAIN SERVICE ENTRANCE GROUND. LEAVE 8' LOOP.26. OUTLET TO BE MOUNTED UNDER COUNTER IN MILLWORK.27. PROVIDE JUNCTION BOX FOR UPS UNIT MOUNTED AT 24" AFF.28. PROVIDE JUNCTION BOX FOR UPS UNIT MOUNTED AT 30" AFF.29. ALL RECEPTACLES IN THE FOOD SERVICE AREA SHALL BE MOUNTED HORIZONTALLY. COORDINATE ALL RECEPTACLE LOCATIONS WITH THE FOOD SERVICE EQUIPMENT BEING INSTALLED.30. COORDINATE EXACT LOCATION OF JUNCTION BOXES WITH REFRIGERATION CONTRACTOR. GENERAL CONTRACTOR RESPONSIBLE FOR FINAL CONNECTION TO DOOR LIGHTS AND HEAT.31. 18-5 TSTAT CABLE TO ROOFTOP REFRIGERATION UNIT BY REFRIGERATION CONTRACTOR. 32. NOT USED 33. PROVIDE PLUG, RECEPTACLE AND SUITABLE COVER FOR CONNECTION OF OVEN CABLE. REVIEW OVEN INSTALLATION DETAILS AND COORDINATE EXACT REQUIREMENTS FOR FINAL CONNECTION.34. E.C. TO INSTALL (2) 2"X4" BACK-BOXES STACKED WITH CONDUIT AND PULL STRINGS TO CEILING FOR HVAC SENSORS. COORDINATE DEVICE LOCATION ON MECHANICAL SHEET M1.35. E.C. TO INSTALL 2"X4" BACK-BOX AT 54" AFF (UNO) WITH CONDUIT AND PULLSTRING TO ABOVE CEILING FOR HVAC SENSOR. COORDINATE WITH DEVICE LOCATION ON MECHANICAL SHEET M1.36. E.C. TO INSTALL (1) 2"X4" BACK-BOXES AT HEIGHT GIVEN ON PLAN WITH CONDUITS AND PULL STRING TO ABOVE CEILING FOR BAS CONNECTION TO OVEN(S)..37. E.C. TO INSTALL (1) 2"X4" BACK-BOXES AT HEIGHT GIVEN ON PLAN WITH CONDUITS AND PULL STRING TO CEILING FOR TELEPHONES.38. REMOTE TRASH COMPOUND. RE: CIVIL DRAWINGS FOR LOCATION OF TRASH COMPOUND. 39. PORTABLE GENERATOR CONNECTION BOX. RE: DETAIL ON SHEET E6. ALSO, RE: SINGLE LINE DIAGRAM SHEET E7 FOR MORE INFORMATION.40. SURFACE MOUNT RECEPTACLE AND DATA TO MOUNTING BRACKET BEHIND DIGITAL MONITORS. RUN FLEX METAL CONDUIT FROM ABOVE CEILING DOWN TO RECEPTACLE. RUN DATA AND POWER CABLES AND FLEX CONDUIT DOWN FROM CEILING IN SUPPORT PIPE. PROVIDE 10' OF SLACK IN CABLES AND FLEX CONDUIT ABOVE CEILING. PLUG (2) GOOSE SIGNS AT EACH END OF MONITORS TO JUNCTION BOX AT EACH END RECEPTACLE. REFERENCE ARCHITECTURAL DETAIL.41. GFCI RECEPTACLE FOR ROLLING RACK TIMER, 48" AFF, EQUIPMENT #B44.42. NOT USED.43. PROVIDE DISCONNECT WITH ACCESSABLE COVER TO PREVENT ACCIDENTAL SHUT-OFF.44. BRING POWER/DATA UP FROM STUB-UP IN WALL INTO CABINETRY. RE: SHEET E4 45. PROVIDE L14-50R AND MATCHING 90 DEGREE L14-50P FOR COFFEE BREWERS.46. E.C. TO PROVIDE FLUSH MOUNTED RED DOT CODE KEEPER FLUSH MOUNTED ZINC WHILE-IN-USE WEATHERPROOF COVER FOR POWER WASH. X T LEGEND J WP IG GFI CP D S M S EQUIPMENT NUMBER. RE: EQUIP. SCHEDULE.DUPLEX RECEPT. (FLOOR MOUNTED)DUPLEX RECEPTACLE CONDENSATION PUMP VERIFY LOCATION IF REQUIRED WITH WAWA CONSTRUCTION MANAGER GROUND FAULT INTERRUPT (RE: GEN. NOTE 8)BANK OF TELEPHONE OUTLETS (34"AFF):1, #2-( 2)TWO LINE PHONE JACK 3-RJ41S JACK (COMPUTER) 4-R.O.I. (COMPUTER)GASOLINE EMERGENCY SHUT-OFF PUSH BUTTON PROVIDED BY ELECTRICAL CONTRACTOR QUADRUPLEX RECEPTACLE ON DEDICATED CIRCUIT GASOLINE EMERGENCY SHUT-OFF RESET PUSH BUTTON INSTALLED IN MANAGERS OFFICE BELOW FUEL TANK MONITOR AND ON CONTACTOR PANEL FOR RPD.TRANSFORMER - FLUSH VALVES (RE: KEYNOTE 12)TELEPHONE\DATA OUTLET (RE: GEN. NOTE # 10) DISCONNECT SWITCH ISOLATED GROUND WEATHERPROOF JUNCTION BOX TF TRANSFORMER BELL/ BUZZER (RE: GEN. NOTE 5)TWIST LOCK/ STRAIGHT BLADE DEDICATED RECEPTACLERSINGLE RECEPTACLE DUPLEX RECEPTACLE MOTOR RATED SWITCH W/ SEPARATE DISCONNECT C CONNECTION POINT. ELECTRICAL CONNECTIONS TO BE MADE AT EQUIPMENT AS REQUIRED.DUPLEX RECEPT. ( CEILING MOUNTED)USB RECEPTACLE USB TW SPECIAL PURPOSE RECEPTACLE, SEE PLAN FOR NEMA CONFIGURATION, TWIST LOCK L ELECTRICAL CABLE, 15' COILED, FOR REFRIGERATION EQUIPMENT.NOTE:ALL PHONES LINES TO BE GROUNDED. PROVIDE 120V SERVICE W/ ISOLATED GROUND RECEPTACLE AND SINGLE POINT GROUNDING FOR D.E. C./ S.A.S.I. EQUIPMENT SELF-TEST/ RESET BLANK FACE GFI OUTLET HORIZONTALLY MOUNTED RECEPTACLE WITH STAINLESS STEEL COVER. RE: KEYNOTE # 14 & 29. EQUIPMENT RPC-6 PROFESSIONAL LABEL, INDICATING PANEL, CIRCUIT NUMBER AND EQUIPMENT SERVED. RE: GEN. NOTE #4.REFER TO EQUIPMENT SCHEDULE SHEET EQ1.GROUND FAULT INTERRUPT RECEPTACLE WITH CIRCUIT TRIP LED INDICATOR LIGHT. RE: GEN NOTE #8. AC,A/C AIR CONDITIONING AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION AMP,A AMPERE ATS AUTOMATIC TRANSFER SWITCH AV AUDIO/ VISUAL AWG AMERICAN WIRE GAUGE BAS BUILDING AUTOMATION SYSTEM BLDG BUILDING BRKR CIRCUIT BREAKER C CONDUIT CAND CANDELA COMPT COMPUTER CT CURRENT TRANSFORMER CUST CUSTOMER E. C. ELECTRICAL CONTRACTOR ELEC ELECTRICAL EMT ELECTRICAL METALLIC TUBING EOL END OF LINE EWH,WH ELECTRIC WATER HEATER FACP FIRE ALARM CONTROL PANEL G, GND GROUND GFCI, GFI GROUNG FAULT CIRCUIT INTERRUPTER GRC GALVANIZED RIDGID CONDUIT IMC INTERMEDIATE METAL CONDUIT INFO INFORMATION KAIC KILO (THOUSAND) AMPERE INTERRUPT CAPACITY KVA KILO (THOUSAND) VOLT*AMPERES KVM KERNEL-BASED VIRTUAL MACHINE CONTROL VIDEO MONITORS)KW KILO ( THOUSAND) WATTS LGT, LGTS LIGHTS MC METAL- CLAD MDP MAIN DISTRIBUTION PANEL N NEUTRAL NC NORMALLY CLOSED NAC NOTIFICATION APPLIANCE CIRCUIT NEC NATIONAL ELECTRICAL CODE P POLE,PHASE PH PHASE PVC POLYVINYL CHLORIDE RECPT RECEPTACLE RM ROOM RR RESTROOM SERV SERVER TELE TELEPHONE TERM TERMINAL THHN THERMOPLASTIC HIGH HEAT NYLON UC UNDER COUNTER UNO UNLESS NOTED OTHERWISE UPS UNINTERRUPTED POWER SYSTEM V VOLTS VEST VESTIBULE W WIRE W-I WALK-IN WP WEATHER PROOF ELECTRICAL ABBREVIATIONS: RECYCLING DUMPSTER MPT TRASH COMPACTOR EC SHALL PROVIDE (2) LIGHTING FIXTURES (BASIS OF DESIGN: RAB VXBRLED26NDG). POWER FED FROM LPA- 11 VIA CONTACTOR LC- 3.96"45 "NEMA 3R RPC- 9, 11, 13 TRASH COMPACTOR DISCONNECT WP GFI DUPLEX RECEPTACLE FOR SONOZAIRE 84"96"38 2- 1/2"C POWER TO RPC) ELEC. RM.SEE NOTE 2 ONSHEETE4) Z1 RPC-21, 23WP, 48" L6- 15R 46 LPA-11 16 SHEET TITLECLIENT NAMEPROJECTNAMECHECKEDDRAWNDATEPROJECT NO.COPYRIGHT © -All reports, plans, specifications, computer files, field data, notes and other documents areinstruments of service preparedby: Cuhaci & Peterson, (