Loading...
HomeMy WebLinkAbout5380-F85FB-v20.0 - Sheet - E3 - ROOF LIGHTING AND POWER PLANMDP-13:15:17 GFI WP 2 1 3 1 3 1 3 RTU-2 RTU-1 RTU-3 MASTER-BILT UNIT MDP-1:3:5 MDP-2:4:6 MDP-7:9:11 4 5 5 5ST5 ROOF EXHAUST FAN RPC-25 8 J 8 6 ST 5 SEE SHEET E2 FOR LIGHTS UNDER TOWER SOFFIT RPB-36:38:40 RPB-22:24:26 GFI WP GFI WP GFI WP RF RF LPA - 18 LPA - 18 EL2 EL2 EL2 EL2 EL2 EL2 EL3 EL3 EL3 EL3 EL3 LPA - 12 LPA - 12 LPA - 12 LPA - 12 LPA - 12 LPA - 12 LPA - 12 LPA - 12 LPA - 12 LPA - 12 LPA - 12 EL3 EL3 EL3 EL3 EL3 EL3 EL3 EL3 EL3 LPA - 12 LPA - 12 LPA - 12 LPA - 12 LPA - 12 LPA - 12 LPA - 12 LPA - 12 LPA - 12 RPC -5 RPC -5 RPC -5 RPC -5 RPC -5 J 7 7 GFI WP 44 LPA - 18 RF 5 ROOF EXHAUST FAN RPC-25 GENERAL NOTES: KEYNOTES: 1. MAIN DISCONNECT PROVIDED WITH UNIT. POWERED CONVENIENCE OUTLET PROVIDED WITH UNIT. 2. E.C. SHALL PROVIDE COMPLETE CONDUIT/CONDUCTOR SYSTEM FROM MDP TO UNIT VIA DISCONNECT. 3. E.C. SHALL PROVIDE COMPLETE CONDUIT/CONDUCTOR SYSTEM FROM MDP TO SINGLE POINT CONNECTION AT UNIT. 4. PROVIDE SUPPORT RACK ATTACHED TO UNIT AS REQUIRED TO MOUNT ELECTRICAL EQUIPMENT. 5. E.C. SHALL PROVIDE (4) LIGHTING FIXTURES (BASIS OF DESIGN -VAPOLET VFN42CUW-LP-PG). PROVIDE WEATHERPROOF SWITCH WITH TIMER NEAR ACCESS LADDER AND DOOR. FIXTURES AND SWITCHES TO BE SURFACE MOUNTED 6" BELOW TOP OF WALL OR 48" ABOVE FLOOR IN TOWER. PROVIDE COMPLETE CONDUIT/CONDUCTOR SYSTEM FOR FIXTURES AND SWITCHES BACK TO POWER PANEL IN ELECTRICAL ROOM. 6. ELECTRICAL POWER TO MASTER-BILT UNIT TO RUN THROUGH PROVIDED GOOSENECK NEXT TO UNIT. DO NOT CREATE SEPARATE ROOF PENETRATION. 7. ELECTRICAL CONTRACTOR SHALL REFER TO DETAIL 2/E3 FOR INSTALLATION OF ANTENNAS ON TOWER WALL. 8. WALL MOUNTED WEATHERPROOF JUNCTION BOX TO SERVE "EL3" LIGHTS ON TOP OF CANOPY. MOUNT BOTTOM OF J-BOX AT 3" ABOVE TOP OF CANOPY. X 1. E.C. TO LABEL EACH RECEPTACLE AND EXHAUST FAN SWITCH WITH CIRCUIT NUMBER AND INTENDED USE. 2. ALL GFI RECEPTACLES SHALL BE DUPLEX RECEPTACLES U.N.O. WITH LED INDICATOR LIGHT. LEVITON #6898-W OR APPROVED EQUAL. NO FEED THRU PROTECTION PERMITTED. SEE DETAIL 2/E1. 3. WHERE WEATHERPROOF COVERS ARE DENOTED, PROVIDE 'WHILE-IN-USE' COVERS. 4. ALL RECEPTACLES SHALL BE MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. 5. E.C. TO COORDINATE INSTALLATION OF ALL ROOF LIGHTING FIXTURES WITH ROOFING CONTRACTOR TO PROVIDE A STRUCTURALLY SOUND AND WEATHERPROOF "LEAK FREE" INSTALLATION. RUN CONDUITS IN PARAPET WALL, NO EXPOSED CONDUITS OR EXTRA ROOF PENETRATIONS. 1/2" LIQUID TIGHT CONDUIT CONNECTOR 1/2" LIQUID TIGHT CONDUIT 1/2" LIQUID TIGHT CONDUIT CONNECTOR WEATHER PROOF SINGLE GANG BOX WEATHER PROOF COVER WIFI ANTENNA 1/2" LIQUID TIGHT CONDUIT STRAP SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDDRAWNDATEPROJECT NO.COPYRIGHT © -All reports, plans, specifications, computer files, field data, notesand other documents are instruments of