HomeMy WebLinkAbout5380-F85FB-v20.0 - Sheet - E8 - FIRE ALARM SPECIFICATIONS PLANFEXIT EXITEXITFFFFEXITK FP PP PPP R 135° R 135° 15 CAND.15 CAND. 110 CAND. 75 CAND. R 194° 75 CAND. 75 CAND. R 135° 15 CAND. 15 CAND. 15 CAND. 75 CAND. R 194° L-1/ D-70 15 CAND. P P 110 CAND. P 110 CAND. R 194° R 194° P P P P D-46/ L-1 P FACPNACFASA 1 2 2 2 2 3 110 CAND. P ASSOCIATE VESTIBULE OFFICE D P D D D DD 54" RTU-2 RTU-3 RTU-1 STSF PROVIDE AT SPRINKLER RISER P 2 75 CAND. P 110 CAND. 110 CAND. WOMEN'S RESTROOM STAGING 4 4 4 F 194° F 194° F 194° F 194° COFFEE RETAIL AREA FOOD SERVICE WASH ROOM WALK-IN REFRIG. WALK-IN FREEZER ELECTRICAL ROOM MEN'S RESTROOM REAR VESTIBULE RETAIL WALK-IN REFRIG. DELIVERY VESTIBULE SELF SERVICE WALK-IN REFRIG. WATER SERVICE ROOM LEGEND END OF LINE FIRE ALARM SYSTEM ANNUNCIATOR FIRE ALARM CONTROL PANEL SPRINKLER FLOW SPRINKLER TAMPER RTU MOUNTED SMOKE DETECTOR FIRE ALARM PULL STATION FIRE ALARM HORN/STROBE ANNUN. EOL HEAT DETECTOR -RATE OF RISE PHOTOELECTRIC SMOKE DETECTOR 194° FASA FACP ST SF HEAT DETECTOR -FIXED TEMP. 194° FIRE ALARM STROBE NOTIFICATION APPLIANCE CERT.NAC R F D P P 1. FIRE ALARM SYSTEM INSTALLED BY OTHERS. E.C. TO PROVIDE 3/4" CONDUIT, BOX AND PULL STRING FOR ALL PULL STATIONS & STROBES LOCATED IN BUILDING. 2. FIRE ALARM CONTROL PANEL TO BE MOUNTED 96" AFF. 3. UNLESS OTHERWISE NOTED, MOUNT ALL PULL STATIONS AT 48" AFF AND AV'S TO 84". 4. ALL FIRE ZONE DEVICES SHALL BE WIRED WITH 18 GUAGE/ 2 PAIR RED FIRE WIRE. 5. SPRINKLER TAMPER AND FLOW SWITHCES ONLY USED IF REQUIRED BY AHJ. RE: ELECTRICAL CONDUIT PLAN FOR CONDUIT TO TAMPER AND FLOW SWITCHES AT BACKFLOW PREVENTER IF REQUIRED BY AHJ. 6. ALL FIRE ALARM HORN/STROBES SHALL BE WIRED WITH 16 GUAGE/ 2 PAIR RED FIRE WIRE WHEN NOT USING SILENT KNIGHT 5495 POWER SUPPLY. 7. CONNECTION BETWEEN SECURITY CAMERA SYSTEM AND FIRE ALARM SYSTEM PANEL SHALL BE A 22 GUAGE/ 2 PAIR. 8. DRAWING IS FOR INFORMATION PURPOSES ONLY. FINAL FIRE ALARM PLAN TO BE PROVIDED BY A LICENSED CONTRACTOR. GENERAL NOTES: KEYNOTES: 1. FIRE ALARM CONTROL PANEL TO BE MOUNTED 96" AFF. PROVIDE 1" CONDUIT FROM FIRE ALARM CONTROL PANEL TO SECURITY PANEL LOCATED IN THIS ELECTRICAL ROOM. 2. FIRE ALARM PULL STATION SHALL BE NOT LESS THAN 3'-6" (1.1M) AND NOT MORE THAN 4'-6" (1.5M) AFF. PROVIDE PROTECTIVE COVER TO PREVENT ACCIDENTAL INITIATION. 3. FOR EXACT LOCATION OF ALL DEVICES IN MANAGER'S OFFICE, RE: ARCHITETURAL ELEVATIONS SHEET. 4. FACTORY INSTALLED SMOKE DETECTOR IN MAIN SUPPLY AND RETURN OF EACH ROOF TOP UNIT. X A. ALL FIRE PROTECTION SYSTEM CONTROL VALVES SHALL BE PROVIDED WITH TAMPER SWITCHES AND INTERFACE WITH THE FACP ON THE SUPERVISORY CIRCUIT, ALL FLOW SWITCHES SHALL INTERFACE WITH THE FACP ON THE ALARM CIRCUIT. B. FIRE ALARM CONTROL PANEL TO BE MOUNTED 96" AFF. PROVIDE 1" CONDUIT FROM FIRE ALARM CONTROL PANEL TO SECURITY PANEL LOCATED IN THIS ELECTRICAL ROOM. FIRE ALARM PULL STATION SHALL BE NOT LESS THAN 3'-6" 1.1M) AND NOT MORE THAN 4'-6" (1.5M) AFF. PROVIDE PROTECTIVE COVER TO PREVENT ACCIDENTAL INITIATION. FOR EXACT LOCATION OF ALL DEVICES IN MANAGER'S OFFICE, SEE ARCHITECTURAL ELEVATIONS SHEET. FACTORY INSTALLED SMOKE DETECTOR IN MAIN SUPPLY AND RETURN OF EACH ROOF TOP UNIT. C. THE FIRE ALARM SYSTEM SCOPE OF WORK SHALL INCLUDE THE PREPARATION AND DESIGN OF THE FIRE ALARM SYSTEM LAYOUT DOCUMENTS (WORKING PLANS). PROVIDE ALL EQUIPMENT, MATERIALS, COMPONENTS, ASSEMBLIES AND SUPPORT SYSTEMS REQUIRED, AS DESCRIBED, IN NFPA 72. THE FIRE ALARM CONTRACTOR SHALL ADD BACKUP BATTERY CALCULATIONS FOR THE DESIGN OF THE FIRE ALARM SYSTEM. D. THE FIRE ALARM DESIGN, CALCULATIONS, INSTALLATION AND THE ACCEPTANCE TESTING OF THE FIRE ALARM SYSTEM SHALL BE IN ACCORDANCE WITH NFPA 72, THE FLORIDA BUILDING CODE (2017) AND THE FLORIDA FIRE PREVENTION CODE 2017) AND ALL LOCAL CODES REQUIRED BY THE AUTHORITY HAVING JURISDICTION. E. THE FIRE ALARM CONTRACTOR SHALL PREPARE AND PROVIDE SIGNED AND SEALED FIRE ALARM SYSTEM LAYOUT DOCUMENTS WITH BACKUP BATTERY CALCULATIONS AND SHALL BE THE ENGINEER OF RECORD. SIGNED AND SEALED FIRE ALARM SYSTEM LAYOUT DOCUMENTS WITH BACKUP BATTERY CALCULATIONS SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER AND THE LOCAL AHJ FOR ACCEPTANCE PRIOR TO PERMITTING. FLORIDA ADMINISTRATIVE CODE CHAPTER 61G15-32 NOTES TELLULAR TG-7 CELL PHONE LINE #1 PHONE LINE #2 FACP FCPS DACT 120VAC 2#12 AWG THHN CONDUCTOR PANEL E BREAKER CIRCUIT #8 OVERCURRENT 20 AMP 120 VOLT MAXIMUM. 1#12 AWG THHN CONDUCTOR CIRCUITS TO INITIATION AND NOTIFICATION DEVICES SEE FIRE ALARM DRAWINGS TO REMOTE SUPERVISING STATION) CIRCUITS TO INITIATION AND NOTIFICATION DEVICES SEE FIRE ALARM DRAWINGS SHEET TITLECLIENT NAMEPROJECTNAMECHECKEDDRAWNDATEPROJECTNO.COPYRIGHT © -Allreports, plans, specifications, computer files, field