Loading...
HomeMy WebLinkAboutLightingCOMcheck Software Version 4.1.2.1 Interior Lighting Compliance Certificate Project Title: 2017 Florida Building Code, Energy Conservation Project Type:New Construction Construction Site: Orange Ave. & Kings Hwy. Ft. Pierce, FL 34945 Owner/Agent: Cuhaci & Peterson Architects Engineers and Planners 1925 Prospect Ave. Orlando, FL 32814 407-661-9100 Designer/Contractor: Cuhaci & Peterson Architects Engineers and Planners 1925 Prospect Ave. Orlando, FL 32814 407-661-9100 Project Information Energy Code: Wawa - ORN - F85FB - 2180719 Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Allowed Interior Lighting Power A Area Category B Floor Area ft2) C Allowed Watts / ft2 D Allowed Watts B X C) 1-Retail 5831 1.13 6612 6612TotalAllowedWatts = Proposed Interior Lighting Power E C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C of Fixtures 1-Retail DL1/DL1E: DL1/DL1E: Recessed 6" LED Downlight: LED Other Fixture Unit 28W:1 15 30 450 DL3/DL3E: DL3/DL3E: Recessed 4" LED Downlight: LED Other Fixture Unit 28W:1 23 30 690 GL1/GL1E: GL1/GL1E: Recessed 2x2 LED: LED Other Fixture Unit 36W:1 55 37 2035 GL3/GL3E: GL3/GL3E: Recessed 2x4 LED: LED Other Fixture Unit 40W:1 14 35 490 GL5/GL5E: GL5/GL5E: Recessed 2x6 LED: LED Other Fixture Unit 46W:1 1 44 44 HL: HL: Vapor Tight LED Sfc. Mnt.: LED Other Fixture Unit 28W:1 2 27 54 LL1: LL1: 4' Rec. linear LED wallwasher: LED Other Fixture Unit 36W:1 1 38 38 LL2: LL2: Linear LED per foot: LED A Lamp 2.5W:1 26 2 57 PL1: PL1: Pendant LED Lamp: LED Other Fixture Unit 16W:1 9 18 162 SH/SHE: SH/SHE: 4' Vaportight linear LED: LED Linear 33W:1 7 38 266 SL1: SL1: 4' LED Wall Grazer: LED Other Fixture Unit 6.5W:4 3 28 84 4370TotalProposedWatts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.1.2.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Interior Lighting PASSES: Design 34% better than code Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Reportdate: 101ofPage Jaison P. Moras, P.E. Name - Title Signature Date Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Reportdate: 102ofPage 04/17/2020 COMcheck Software Version 4.1.2.1 Exterior Lighting Compliance Certificate Project Title: 2017 Florida Building Code, Energy Conservation Project Type:New Construction Construction Site: Orange Ave. & Kings Hwy. Ft. Pierce, FL 34945 Owner/Agent: Cuhaci & Peterson Architects Engineers and Planners 1925 Prospect Ave. Orlando, FL 32814 407-661-9100 Designer/Contractor: Cuhaci & Peterson Architects Engineers and Planners 1925 Prospect Ave. Orlando, FL 32814 407-661-9100 Project Information Energy Code: Wawa - ORN - F85FB - 2180719 4 (High activity metropolitan commercial district)Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts B X C) Overhangs at entry doors and seating area (Entry canopy)1136 ft2 0.4 Yes 454 Exterior wall lighting (Illuminated area of facade wall or surface)2463 ft2 0.2 No 493 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 454 947 1300 a)Wattage tradeoffs are only allowed between tradable areas/surfaces. b)A supplemental allowance equal to 1300 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C of Fixtures Overhangs at entry doors and seating area ( Entry canopy 1136 ft2): Tradable Wattage DL2/DL2E: DL2/DL2E: Recessed 4.5" LED Downlight: LED PAR 20W:1 6 16 96 DL7/DL7E: DL7/DL7E: Wet Loc. Rec. 6" LED Downlight: LED Other Fixture Unit 28W:1 22 30 660 Exterior wall lighting ( Illuminated area of facade wall or surface 2463 ft2): Non-tradable Wattage EL2: EL2: Wet Loc. LED Strip: LED Other Fixture Unit 6.5W:1 6 8 45 EL3: EL3: Wet Loc. LED Strip: LED Other Fixture Unit 6.5W:1 14 8 105 RF: RF: Wet Loc.LED Area Light: LED Other Fixture Unit 6.5W:1 4 27 108 REM2: REM2: Twin Remote Head Emer. Light: LED PAR 12W:2 3 18 54 WC1: WC1: Decorative LED Wall Sconce: LED Other Fixture Unit 13W:1 4 23 92 Z1: Z1: Wall Mtd. Ext. Area LED: Other:1 6 50 300 756TotalTradableProposedWatts = Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.1.2.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Exterior Lighting PASSES: Design 51% better than code Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Reportdate: 103ofPage Jaison P. Moras, P.E. Name - Title Signature Date Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Reportdate: 104ofPage 04/17/2020 Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.2.1 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2017 Florida Building Code, Energy Conservation Section Req.ID Plan Review Complies?Comments/Assumptions C405.6 PR17]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Provisions are made for metering individual tenant units. Feeder connectors (for feeder and branch circuits) sized in accordance with approved plans with maximum drop of 5% voltage drop total. Complies Does Not Not Observable Not Applicable C103.2 PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable C103.2 PR8]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable C406 PR9]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Reportdate: 105ofPage Section Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions C402.2.6 FO12]3 Radiant heating systems panels insulated to >=R-3.5 on face opposite space being heated. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Reportdate: 106ofPage Section Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.1 EL15]1 Lighting controls installed to uniformly reduce the lighting load by at least 50%. Complies Does Not Not Observable Not Applicable C405.2.1 EL18]1 Occupancy sensors installed in required spaces. Complies Does Not Not Observable Not Applicable C405.2.1, C405.2.2. 3 EL23]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable C405.2.2. 1 EL22]2 Automatic controls to shut off all building lighting installed in all buildings. Complies Does Not Not Observable Not Applicable C405.2.3 EL16]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. Complies Does Not Not Observable Not Applicable C405.2.3, C405.2.3. 1, C405.2.3. 2 EL20]1 Primary sidelighted areas are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable C405.2.3, C405.2.3. 1, C405.2.3. 3 EL21]1 Enclosed spaces with daylight area under skylights and rooftop monitors are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable C405.2.4 EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable C405.2.4 EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable C405.2.5 EL25]null Automatic lighting controls for exterior lighting installed. Controls will be daylight controlled, set based on business operation time-of-day, or reduce connected lighting > 30%. Complies Does Not Not Observable Not Applicable C405.3 EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Reportdate: 107ofPage 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Reportdate: 108ofPage Section Req.ID Final Inspection Complies?Comments/Assumptions C303.3, C408.2.5. 2 FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable C405.4.1 FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C405.5.1 FI19]1 Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Exterior Lighting fixture schedule for values. C408.2.5. 1 FI16]3 Furnished as-built drawings for electric power systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable C408.3 FI33]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Reportdate: 109ofPage Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Reportdate: 1010ofPage