Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5380-F85FB-v20.0 - Sheet - A2 - REFLECTED CEILING PLAN
OS OS M OS M OS M M M M M M OS M OS M M OS 1 2 3 7 7.8 8 F 3 A6.2 3 A6.1 1 A6 1 A6.2 2 A6 2 A6.1 1 A5 2 A5 E 1 A6.1 4 A6.2 LIGHTING @ TOWER SOFFIT ABOVE D A.F.F. 2' X 2' ACT2 10' - 0" A.F.F. INSULATED PANEL 9' - 0" A.F.F. 2' X 2' ACT2 10' - 0" A.F.F. INSULATED PANEL 9' - 0" A.F.F. INSULATED PANEL 9' - 0" 2' - 0" 2' - 6"2' - 4 1/ 2"A. F. F. INSULATED PANEL 9' - 0"DS DS DS STUCCO FINISH WALL LIGHTS RE: ELECTRICALLINE OF SOFFIT ABOVE RE: 2/A21' - 11" A.F. F.5/8" MR GWB 10' - 0" A.F. F.5/8" MR GWB 8' - 6"SEE NOTE 5 A.F. F.5/8" MR GWB 10' - 0"SEE NOTE 5 A.F. F.5/8" MR GWB 10' - 0" SEE NOTE 5 10' - 0 5/ 8" 5' - 6" 5' - 6"DS DS DS TROUGH ABOVE.RE: ELECTRICAL DWGS PENDANT LIGHT, ALIGN W/ CABINET BELOW AS SHOWN. BOT, @ 8'-0" A. F. F. EXTERIOR EMERGENCY LIGHT CENTERED ABOVE DOORWAY EXTERIOR EMERGENCY LIGHT CENTERED ABOVE DOORWAY CREATE 2' X 3' ACCESS FOR WALK-INS 6" ABOVE THE CEILING IN THIS AREA. FROM BLDG CENTERLINE TO CENTERLINE OF SOFFIT 20' - 2"BUILDING CENTERLINES.RE: SHEET A1 M CENTER FIXTURE OVER LAVATORY (TYP) RECESSED DOWNLIGHT, TYP RE: ELECTRICAL CENTERLINE OF FOOD SERVICE COUNTER BELOW 2 A9.1 3' - 4" EQEQEX EX EX COMPLETELY SEAL PERIMETER OF CEILING CREATE 2' X 3' ACCESS FOR WALK- INS 6" ABOVE THE CEILING INTHIS AREA EF SECURITY CAMERA, TYP RE: ELECTRICALSECURITY CAMERA, TYP RE: ELECTRICAL DS DS 6' - 0"2' - 4" 9' - 6"10' - 0" 10' - 0" 10' - 0" 24" X30" ACCESS PANEL RE: DOOR SCHEDULE AP4 EVAPORATORS, TYP SECURITY CAMERAS RE: ELECTRICAL VESTIBULE 1 OFFICE 5 ASSOCIATE 19 WATER SERVICE ROOM 20 WOMEN'S RESTROOM 23 STAGING 16 9 3/4" 4' - 10" 10' - 1"9' - 9"ALL MUSIC SPEAKERS AND OCCUPANCY SENSORS CENTERED IN CEILING TILE U. N. O. ( TYP.)1' - 6"0"1' - 10"PROVIDE ARMSTRONG 7808 ANGLE MOLDING AT STONE. DS RE: NOTE 5)9 A9 6' - 4" DUPLEX OUTLET DUPLEX OUTLET 2' - 11"MR GWB ON 8" 16-GA. METAL STUDS AT 24" O.C. TYP AT MEN'S WOMEN' S RESTOOMS AIR CURTAIN 1' - 6"16 A7 PROVIDE 3/4" PLYWOOD DECK OVER RESTROOM CEILING JOISTS. AT MEN' S & WOMEN'S RESTOOMS DOWNLIGHT, CENTERED IN PANEL. 4 A5 10' - 0" 10' - 0" 3' - 5"2' - 6"6' - 1" 2' - 2" UN- VENTED SOFFIT THIS AREA A. F.F. 5/ 8" MR GWB 13' - 6" SEE NOTE 5 C B A 3.5 4 5 6 P1 P1 P1 P1 1' - 6" ACOUSTICAL CEILING CONTINUES ABOVE SOFFIT A2 4 LED STRIP LL2 10 A2 SEE 4/A2 AND 3/A2 FOR PLAN LAYOUT OF SOFFIT ABOVE 1 A9.1 1' - 0" 1' - 7" 1' - 9" 1' - 9"1' - 0"9"P6 1' - 0" EQ EQ EQ EQRETAIL WALK-IN REFRIG.37 SELF SERVICE WALK- IN REFRIG. 38 REAR VESTIBULE 34 P1 EFWALK-IN FREEZER 28 WALK-IN REFRIG. 29 3' - 4"2' - 0"2' - 0" 5/8" MR GWB, 3-5/ 8" MTL. FRAMING 9'- 0" A. F. F. RECESSED DOWN LIGHTING IN GWB SOFFIT. (TYP.)3' - 0"3' - 0"2' - 11 1/2" 2' - 11 1/ 2" EQ EQ EQ EQ EF EF EQ EQCOFFEE COUNTER BELOW2' - 2"A2 3 4' - 0"4' - 0" 2' - 11"1' - 7" 1' - 10" 2' - 10" 4' - 0" 4' - 0" RETAIL AREA 35 DELIVERY VESTIBULE 36 MEN'S RESTROOM 24 ELECTRICAL ROOM 39 FOOD SERVICE 32 COFFEE 33 A.F.F. 2' X 2' ACT1 13' - 6" WASH ROOM 31 3' - 7"3' - 6 1/2" 6' - 5"5' - 0 1/2" A.F.F. 2' X 2' ACT1 10' - 0" A.F.F. 2' X 2' ACT2 10' - 0" A.F.F. 2' X 2' ACT2 11' - 0" EXTERIOR EMERGENCY LIGHT CENTERED ABOVE DOORWAY EX 5 A2 WALL MTD SIGN RE: SHEET G1 6 A2 8 A2 3 A9. 1 10 A2 A. F.F. 2' X 2' ACT1 10' - 6"7 A2 7 A2 2' - 0" 2' - 0"A.F.F.2' X 2' ACT1 10' - 6"A. F.F. 2' X 2' ACT1 10' - 6" A. F. F.2' X 2' ACT1 10' - 6" A.F. F.2' X 2' ACT1 10' - 6" A.F. F.2' X 2' ACT1 10' - 6" 4' - 0" 4' - 0"4' - 0"4' - 0" 4' - 0"4' - 0"3' - 8 1/2"10"A9. 2 1 6' - 4" 3' - 0"3' - 0"4' - 0"1' - 1 1/ 2"1' - 7 1/2"3' - 4"1' - 0 1/2"3' - 9"3' - 0"3' - 5"1' - 3" 2' - 2"7 1/ 2"EX 1' - 2"1' - 2"4' - 0" 4' - 0"EVAPORATORS, TYP EVAPORATORS, TYP 3' - 8 1/2"EVAPORATOR EXA.F. F.2' X 2' ACT1 9' - 0" A.F. F. 2' X 2' ACT1 9' - 0" A. F.F. 2' X 2' ACT1 13' - 6" B.O. SOFFIT @8'- 0"B. O. SOFFIT @ 9'- 0"EQEQ3' - 2"3' - 2" 2' - 4" 2' - 4"EQEQ1' - 0"1' - 6"3' - 1 1/2"3' - 1 1/ 2"A. F. F. 5/8" MR GWB 8' - 6"SEE NOTE 5 CENTER FIXTURES OVER LAVATORIES (TYP)P6 6' - 3"1' - 6"1' - 0"2' - 5" 3' - 5" 3' - 5"1' - 4 1/2"1' - 0"G 2' - 0"TO UNDERSIDE OF DECK ABOVE 1/2" M.R. GWB, FLUSH W/ FACE OF WALK-IN BOX CONTRUCTION ADHESIVE FRP EDGE MOLDING DELIVERYWALK- IN BOX FRP, RUN PAST JOINT @ TOP OF WALK-IN SEALANT 3-5/8" MTL STUDS AND CONTINUOUS BOTTOM TRACK CONT. LED LIGHTING @ TOWER SOFFIT. RE: ELECTRICAL INSIDE OF TOWERO.H.2' - 0"GUTTER, TYP DOWNSPOUT, TYP O.H. 2' - 0"PANEL SOFFIT (TYP.)OPEN STRUCTURE 1/2" M.R. GWB,BOTH SIDES 3-5/8" MTL STUDS AND CONTINUOUS BOTTOM TRACK FRP ACOUSTICAL CEILING TILE AS SCHEDULED ACOUSTICAL CEILING TILE AS SCHEDULED SCHLUTER QUADEC TILE AS SCHEDULED 6" BOTT. OF FINISH 9' -0" A.F.F.UNDER SOFFIT P1 4-WAY DIFFUSER 3-WAY DIFFUSER 2- WAY DIFFUSER 2-WAY DIFFUSER 1-WAY DIFFUSER VERIFY DIFFUSER TYPE WITH HVAC PLAN SHEET M1.REFER TO MECHANICAL SHEETS FOR MORE INFORMATION.RETURN LINEAR DIFFUSER EF EXHAUST INTERIOR FINISH TAG RE: SHEET A8 FOR FINISH SCHEDULE P1 2 X 4 LED FIXTURE 2 X 2 LED FIXTURE 2 X 2 EMERGENCY LED FIXTURE 2 X 4 EMERGENCY LED FIXTURE B.O. CHASE CLG HT.RE: RCP T. O. CHASE 4- SIDED 3/ 4" PLYWD CHASE FOR SODA LINES. 8" X8" MIN. CLEAR INSIDE DIMENSION. FASTEN TO WALL 8"FRP FINISH ALL EXPOSED SURFACES ACOUSTICAL CEILING TILE 1' - 0" 6" P1 PROFILE AT WALK- IN REFRIGERATOR UNDER SOFFIT INTERIOR FASCIA FRAMING. RE: STRUCTURAL ACT CLG 13' -6"A.F. F.B.O. SOFFIT 7' - 1"A.F.F. GWB CLG 9' - 0"A.F. F. ACOUSTICAL CLG TILE 1' - 0"GLASS TILE OVER M. R. GWB ON 3-5/ 8" MTL STUDS @ 16" O.C.1' - 4"5/ 8" GWB ON 3- 5/8" MTL STUDS @ 12" O.C.PAINTED GWB.RE: ELEVATIONS 1X4 WOOD CEILINGTRIM. 6"LED STRIP LIGHT MOUNTED ON TILTABLE STAND. ADJUST ANGLE IN FIELD TO DIRECT LIGHT ONTO WALL.RE: ELECTRICAL 2"2X6 BLOCKING AT MOUNTING ANGLE LETTER LOGO SIGN IN SUPPORT TUBES BY SIGN VENDOR CO. A9 10 RECESSED DOWNLIGHTING IN GWB SOFFIT.10 1/ 2"4' - 0" 4' - 0" 4' - 0"8" 4' - 0" 4' - 0"8"10' - 5" 14' - 3"8" 10 A2 DL3 4- IN. DOWNLIGHT, TO BE LOCATED IN THE GWB SOFFIT, TYP. RE: ELECTRICAL LL2 LED STRIP LIGHT, TYP., TO BE MOUNTED ON TOP OFSOFFIT, ON TILTABLE STAND. DIRECT TOWARD WALL. RE: ELECTRICAL 6"6" DL3 4-IN. DOWNLIGHT, TO BE LOCATED IN THE GWB SOFFIT, TYP. RE: ELECTRICAL LL2 LED STRIP LIGHT, TYP., TO BE MOUNTED ON TOPOF SOFFIT, ON TILTABLE STAND. DIRECT TOWARD WALL. RE: ELECTRICAL NOTE:REF SHEET E2 FOR LIGHTING INFORMATION. 1 A9.11' - 9"1' - 9"4' - 0"4' - 0"2' - 7 1/2"3' - 6" 10"CEILING HEIGHT B.O. SOFFIT 1" CORNER GUARD 1/2" LEVEL 5 GWB, BOTH SIDES 3-5/8" MTL STUDS AND CONTINUOUS BOTTOM TRACK SOFFIT AT EXPRESS CASE 7' - 4"9' - 0"WOOD VENEER BY WAWA B.O. SOFFIT WALK-IN REFRIGERATOR INTERIOR FASCIA FRAMING. RE: STRUCTURAL HOLD 1/2" GAP BETWEEN STUDS AND WALK-IN UNIT UNDER SOFFIT P1 1/2" GWB ON 3-5/8" MTL STUDS 1/2"7' - 1"SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDDRAWNDATEPROJECT NO.COPYRIGHT © - All reports, plans, specifications, computer files, field data, notes and other documents are instruments of service prepared by: Cuhaci & Peterson, ( C & P) as instruments of service remainthe property of C & P. C & P shall retainall common law, statutory and other reserved rights, including the copyright thereto. Anyuse or reproduction of this document without written permission fromC & P is a violation of Federal copyright laws.4/16/ 2020 12:05:56PMA2218071904- 17-2020S.G.A.D.M. REFLECTED CEILING PLANORANGE AVE. & KINGS HWY, FT. PIERCE, FLWAWA260 WEST BALTIMORE PIKEWAWA, PENNSYLVANIA 19063WAWA F85FB 2020.00 STORE #5380-