Loading...
HomeMy WebLinkAbout5380-F85FB-v20.0 - Sheet - A3 - ROOF PLANA4 1 A42 A4.1 2 3 A6.2 3 A6.1 1 A6 1 A6.2 2 A6 2 A6.1 1 A5 2 A5 1 A6.1 4 A6.2 A4.1 1 MASTER-BILT COMPRESSOR UNIT STANDING SEAM METAL ROOF ROOF LADDER PARAPET CAP 30" X 60" WALKWAY PADS SPACED 6" APART (TYP) RE: GENERAL NOTES) CRICKET (TYP) CRICKET, TYP GUTTER AND DOWNSPOUT SYSTEM OPENING IN PARAPET 28 A3.1 OVERHANG ROOF DRAINS AND D.S. SHALL BE CENTERED ON COLUMNS, TYP RE: EXT. ELEVATIONS RE: 5 & 6/A3 FOR CURB DETAIL SINGLE-PLY ROOFING OVERFLOW SCUPPERS 2" ABOVE ROOF SURFACE (TYP) ROOF SCUPPER AND DOWNSPOUT (TYP) RE: EXT. ELEV FORLOCATIONOVERFLOWSCUPPERS2" ABOVE ROOF SURFACE, (TYP.) SINGLE-PLY ROOFING OVER MIN. R-40 INSULATION -STAGGER AND OFFSET LAYERS OF INSULATION PER MFR RECOMMENDATIONS. RE: SPECIFICATIONS PARAPET CAP 3' - 4"9' - 4 1/2" 36"X48" ACCESS HATCH. RE: DOOR SCHEDULE SHEET A1. 6" / 12"6" / 12" 6" / 12" 6" / 12"PARAPET CAP OVERHANG PORCH OVERHANG STANDING SEAM ROOF HIP CAP DS STANDING SEAM METAL ROOF DS PIPE HOOD FOR MASTER- BILT UNIT ICE MACHINE CONDENSING UNITS AND MECHANICAL STAND RD-1 RD-1 RD-1 RD- 2 PROVIDE CHEMCURB AT EACH OVERHANG -MOUNTED LIGHT FIXTURE LIGHT FIXTURE RE: ELECTRICAL LIGHT FIXTURE RE: ELECTRICAL LIGHT FIXTURE RE: ELECTRICAL 1/ 4" / 12" HVAC UNIT (TYP) SEE MECHANICAL DRAWINGS. SEE 1/M3 FOR CURB DETAIL SINGLE-PLY ROOFING OVER MIN. R- 40 INSULATION -STAGGER AND OFFSET LAYERS OF INSULATION PER MFR RECOMMENDATIONS. RE: SPECIFICATIONS 17 A3. 1 REFRIGERATION LINES 5" / 12"25 A3.1 8 A3 PORCH OVERHANG SINGLE-PLY ROOFING 8' - 10“ PROVIDE WALKMAT UNDER DOWNSPOUTS PROVIDE WALKMAT UNDER DOWNSPOUTS LOTTO SATELLITE DISH LOCATION GC TO PLACE ( 3) LOOSE WALK- PADS IN TOWER FOR LOTTERY VENDOR VTR,RE: PLUMBING VTR, RE: PLUMBING HVAC UNIT ( TYP) SEE MECHANICAL DRAWINGS. SEE 1/M3 FOR CURB DETAIL EXHAUST FAN.RE: MECHANICAL CRICKET ( TYP)(+)CRICKET (TYP)CRICKET, TYP CONDENSATE LINES.RE: MECH.CLEAR3' - 6"4' - 10"4' - 10"4' - 10"2' - 0"4' - 6"4' - 6"4' - 6"4' - 6" 4' - 6"4' - 6" 4' - 6"4' - 6" 2' - 0"4' - 6"4' - 6" 4' - 6" 4' - 6" 4' - 6" TO PLYWOOD3' - 4 1/2"TO ROOF EDGE 1' - 11 1/ 2"TO ROOF EDGE2' - 5 1/ 2"TO ROOF EDGE1' - 0 3/8" SEE EXTERIOR ELEVATION SHEET A4.1 FOR ROOF DRAIN/DOWNSPOUT LOCATIONS AP5 A6 6 A6 7 RD- 1 1/4" / 12"1/4" / 12" 1/4" / 12"1/ 4" / 12" 3/ 4" / 12"RD- 1 RD- 1 1/4" / 12"1/ 4" / 12" 1/ 4" / 12" 1/4" / 12" 1/ 4" / 12" 1/ 4" / 12" 1/ 4" / 12"RD-1 CONDENSATE PIPE SUPPORT, TYP 4'-0" MAX. O. C.RE: DETAIL 9/ M3 CONDENSATE PIPE SUPPORT, TYP 4'-0" MAX. O. C.RE: DETAIL 9/ M3 GUTTER AND DOWNSPOUT SYSTEM A3 2 A3 10 PARAPET CAP PROVIDE CHEMCURB AT EACH TIE ROD KNIFE PLATE A3 5 1/ 2" / 12"1 /2 " / 1 2 " 1/2" / 1 2"1/2 1 2 ROOF SCUPPER AND DOWNSPOUT (TYP)RE: EXT. ELEV FOR LOCATION 1/2" 12"CRICKET (TYP)CRICKET (TYP) 21' - 5"19' - 11 1/2"VTR,RE: PLUMBING 3/4" / 12"CRICKET CRICKET EXHAUST FAN.RE: MECHANICAL 4' - 10" 1 / 2 " / 1 2 "HVAC UNIT (TYP) SEE MECHANICAL DRAWINGS. SEE 1/ M3 FOR CURB DETAIL 6 A3 11' - 6"NOTE:1. ALL PRESSURE TREATED LUMBER. 2.SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION AND ATTACHMENT PER PROJECT WIND SPEED REQUIREMENTS4' - 9 3/4"3/ 4" EXT. P.T. PLYWOOD CONT. 2X12 P.T. STUDS 2X4 P. T. STUDS @ 12" O. C.CONT. 2X8 P.T. STUDS NOTES: 1. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION.MIN. 18-GA. GALVANIZED METAL CAP OVER ENTIREPLATFORM. WATER- TIGHT SOLDERED JOINTS AS NEEDED ACCEPTABLE GASKETED FASTENER, 12" O.C. ROOFING MEMBRANE RIGID INSULATION METAL DECK 3/4" EXT. P. T. PLYWOOD DECK-LEVELPLATFORM REFRIG. UNIT 8" MIN. WRAP PLYWOOD IN 40 MIL. ICE & WATER SHIELD. (ALL SIDES AND TOP) 2) CONT. 2X8 P.T. 2) CONT. 2X12 P. T. 2) CONT. 2X8 P.T.SHIM PLATFORM LEVEL 2X4 @ 12" O.C.EPDM WASHER 1' - 0"20 GA. GALVANIZED SHEET METAL HOODREFRIGERATION LINES RUN STRAIGHT - NO BENDS TOP OF ROOF DECK PRE-FABRICATED CURB UNISTRUT ANCHORED TO CURB. CLAMP DISCHARGE AND DRAIN LINES WITH HYDRO-ZORB OR CUSHA CLAMP8" MIN.FILL OPENING W/ FOAM INSULATION AIR TIGHT AFTER LINES ARE INSTALLED MASTERBILT UNIT 1' - 7" 4"1' - 0"6" 1' - 6" ROOF EL. - 7" FROM ROOF DECK 4' - 0“1' - 9"A3 8A SIM.ALUM. A/ C STAND ( MFR: MIAMI TECH). REFER TO FLORIDA PRODUCT APPROVAL OR MIAMI- DADENOAFORINSTALLATIONINSTRUCTIONSROOFTOPEQUIPMENTTIE- DOWN ANGLE AND FASTENER. PROVIDE QUANTITY AND TYPE PER FLORIDA PRODUCT APPROVAL OR MIAMI-DADE NOA ISOLATORPADS. MIN. 4 PER UNIT RE: STRUCTURAL FOR MOUNTING DETAILS STEEL CHANNEL. RE: STRUCTURAL PROVIDE ROOF MFR'S PRE-FABRICATED PIPE FLASHING AT ALL ROOF PENETRATIONS TOP OF ROOF FINISH METAL DECK.RE: STRUCTURAL AP5LIGHT FIXTURE RE: ELECTRICAL 36" X48" ACCESS HATCH. RE: DOOR SCHEDULE, SHEET A1 STEEL BEAMS. RE: STRUCTURAL TOWER WALL DOWNSPOUT LINE OF TOWER EAVE ABOVE PARAPET WALL5/8" PLYWOOD OVER MIN. R- 40 INSULATION - STAGGER AND OFFSET LAYERS OF INSULATION PER MFR RECOMMENDATIONS. RE: SPECIFICATIONS 20" (MIN.) - 30"(MAX.) 2' - 0" ( MIN.)6"6"2' - 10"3' - 0" 2' - 10"ICE MACHINE CONDENSING UNITS CONDENSER UNIT MOUNTING FLANGE, EA. SIDE OF UNIT SEE STRUCTURAL FOR MOUNTING DETAILS TOSTRUCTURE 9' - 8"JOISTRE: STRUCT.JOISTRE: STRUCT.JOISTRE: STRUCT. 1' - 0"1' - 0" ALUM. STAND SUPPORTPOST, TYP 9 A3 1 A9.1 20GA. GALVANIZED SHEET METAL HOOD REFRIGERATION LINES RUN STRAIGHT -NOBENDS UNISTRUT ANCHORED TO CURB. CLAMP DISCHARGE AND DRAIN LINES WITHHYDRO- ZORB OR CUSHA CLAMP FILL OPENING W/ FOAMINSULATION AIR TIGHT AFTER LINES ARE INSTALLED 20 GA GALV. SHEETMETAL HOOD 2" X 6" -P. T. WOOD BLOCKING MECH. ANCHOR PER MANUFACTURER RECOMMENDATION SLOPE RIGID INSULATION RE: SHEET A3.0 SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDDRAWNDATEPROJECT NO. COPYRIGHT © - All reports, plans, specifications, computer files, field data, notes and other documents are instruments of service prepared by: Cuhaci & Peterson, (C & P) as instruments of service remain the property of C & P. C & P shall retain all common law, statutory and other reserved rights, including the copyright thereto. Any use or reproduction of this document without written permission from C & P is a violation of Federal copyright laws.4/16/2020 12:06:02 PMA3218071904- 17-2020S.G.A.D.M. ROOF PLANORANGE AVE. & KINGS HWY, FT. PIERCE, FLWAWA260 WEST BALTIMORE PIKEWAWA, PENNSYLVANIA 19063WAWA F85FB 2020.00 STORE #5380-ORN04/17/2020 1/4" = 1'-0"A3 1 ROOF PLAN 1/4" = 1'-0"A3 5 COMPRESSOR PLATFORM PLAN 3" = 1'-0"A3 6 COMPRESSOR PLATFORM SECTION 1" = 1'- 0"A3 8 PIPE HOOD DETAIL 1 1/2" = 1'-0"A3 9 CONDENSING UNIT ROOFING SUPPORT DETAIL 3/16" = 1'-0"A3 2 TOWER ATTIC PLAN 1/2" = 1'- 0" A3 10 ICE MACHINE CONDENSER DETAIL 1 1/2" = 1'-0"A3 8A PIPE HOOD/CURB DETAIL 1.RIGID INSULATION SHALL BE TWO LAYERS WITH JOINTS STAGGERED OFFSET) AND TOTAL THICKNESS AS REQUIRED TO MEET THE MINIMUM R-VALUE AS SHOWN ON THE ROOF PLAN.2. GUTTERS SHALL BE CONTINUOUS (NO SEAMS). 3.COORDINATE ALL PLUMBING PENETRATIONS WITH THE PLUMBING DRAWINGS.4. COUNTER SINK ALL SCREWS AT TOP OF PARAPET PLATE LOCATIONS TO PREVENT ROOF MEMBRANE DAMAGE AND TEAR.5.(+) NOTATIONS ON ROOF PLAN INDICATE ADDITIONAL THICKNESS OF TAPERED INSULTATION ADDED TO THE BASE INSULATION THICKNESS. DIRECT WATER TO SCUPPERS AND/OR ROOF DRAINS.6.CONTRACTOR TO UTILIZE TAPERED INSULATION AT ALL CRICKETS. SQUARE EDGES WILL NOT BE ACCEPTABLE.7.CONTRACTOR