Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5380-F85FB-v20.0 - Sheet - A6-1 - WALL SECTIONS AND DETAILS
T.O. FLOOR SLAB 0' -0" JST. BRG. FRONT 17' -10" T.O. PARAPET 22' -4" B.O. OVERHANG 9' -0" T.O. CLERESTORY 13' -6" 8" METAL STUD RE: STRUCTURAL R30 BATT INSULATION (TYP) STEEL BEAM. RE: STRUCTURAL CEMENT BOARD LAP SIDING OVER ONE LAYER HIGH DENSITY POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER MEMBRANE BARRIER OVER 5/8”EXTERIOR GRADE PLYWOOD SHEATHING A6.1 8 A3.1 17 T.O. MULLION & SILL 3' -0" STOREFRONT SYSTEM TERRAZZO FLOOR FINISH TRIM BOARD TYP RE: EXTERIOR ELEVATIONS A7 19 A7 13 INSULATE VOIDS AT BEAMS 4" DOWNSPOUT BEYOND TRIM AT DOWNSPOUT A SINGLE PLY ROOFING SYSTEM OVER RIGID INSULATION (TYP.) RE: ROOF PLAN, SHEET A3 STEEL JOIST (BEYOND) RE: STRUCTURAL STEEL BEAM RE: STRUCTURAL CONCRETE SLAB RE: STRUCTURAL 1/2" GWB TO UNDERSIDE OF DECK A3.1 26 B.O. CLERESTORY 11' -0" SUSPENDED ACOUSTICAL TILE CEILING T.O. FLOOR SLAB 0' -0" T.O. PARAPET 22' -4" B.O. OVERHANG 9' -0" T.O. CLERESTORY 13' -6" HANGER ROD ANCHOR 15' -2" A3.1 28 INSULATE VOIDS AT BEAMS STEEL BEAM. RE: STRUCTURAL CEMENT BOARD LAP SIDING OVER ONE LAYER HIGH DENSITY POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER MEMBRANE BARRIER OVER 5/8”EXTERIOR GRADE PLYWOOD SHEATHING 8" METAL STUD, TYP RE: STRUCTURAL R30 BATT INSULATION CONCRETE SLAB. RE: STRUCTURAL TERRAZZO FLOOR FINISH STOREFRONT SYSTEM 1/2" EXPANSION JOINT W / SEALANT (TYP) SOFFIT STOREFRONT SYSTEM TUBE STEEL BEAM. RE: STRUCTURAL FASCIA PANEL DOWNSPOUT BEYOND A6.1 5 A3.1 17 T.O. MULLION & SILL 3' -0" TRIM BOARD, TYP RE: EXTERIOR ELEVATIONS TRIM AT DOWNSPOUT B SINGLE PLY ROOFING SYSTEM OVER RIGID INSULATION (TYP.) RE: ROOF PLAN, SHEET A3 STEEL JOIST (BEYOND) RE: STRUCTURAL STEEL BEAM RE: STRUCTURAL 1/2" GWB TO UNDERSIDE OF DECK A6.1 10 B.O. CLERESTORY 11' -0" SUSPENDED ACOUSTICAL TILE CEILING 0' - 0" FINISHFLOORT.O. FLOOR SLAB 0' -0" JST. BRG. FRONT 17' -10" T.O. PARAPET 22' -4" INSULATE VOIDS AT BEAMS STEEL BEAM. RE: STRUCTURAL CEMENT BOARD LAP SIDING OVER ONE LAYER HIGH DENSITY POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER MEMBRANE BARRIER OVER 5/8”EXTERIOR GRADE PLYWOOD SHEATHING 8" METAL STUD RE: STRUCTURAL R30 BATT INSULATION LIGHT. RE: ELECTRICAL A7 18 SIM. A3.1 17 T.O. MULLION & SILL 3' -0" CONCRETE SLAB. RE: STRUCTURAL A6.2 5 A6.1 5 ONE LAYER HIGH DENSITY POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER MEMBRANE BARRIER OVER 5/8”EXTERIOR GRADE PLYWOOD SHEATHING A PRE-CAST ADHERED MANUFACTURED STONE WATERTABLE/SILL ADHERED MANUFACTURED STONE VENEER SINGLE PLY ROOFING SYSTEM OVER RIGID INSULATION (TYP.) RE: ROOF PLAN, SHEET A3 STEEL JOIST (BEYOND) RE: STRUCTURAL STEEL BEAM RE: STRUCTURAL 1/2" GWB TO UNDERSIDE OF DECK SUSPENDED ACOUSTICAL TILE CEILING TERRAZZO FINISH FLOOR 10' - 0" CLG HEIGHT FRPC PRESSURE TREATED PLYWOOD4' - 0"1/2" TERRAZZO 1/2" EXPANDABLE FILLER RECESSED & CAULKED CONCRETE SIDEWALK.RE: CIVIL CONC. SLAB ON VAPOR RETARDER THICKENED SLAB AT STOREFRONT 1" INSULATED TEMPERED GLAZING 1/ 2" ALUMINUM GLAZING FRAME SEALANT & BACKER ROD 1/2" TERRAZZO CONC. SLAB ON VAPOR RETARDER THICKENED SLAB AT STOREFRONT 1" INSULATED TEMPERED GLAZING ALUMINUM STOREFRONT FRAME WRAP BRAKE METAL MIN. 6" DOWN SLAB EDGE (BRAKE METAL TO MATCH STOREFRONT)LANDSCAPING MATERIAL T.O. FLOOR SLAB 0' -0" 1 T. O. PARAPET 22' -4" JST. BRG. MID FRONT 17' -6 3/4" T.O. MULLION & SILL 3' -0"7/ 8" STUCCO FINISH OVER 3.4# SELF- FURRING GALVANIZED METAL LATH OVER ONE LAYER HIGH DENSITY POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER MEMBRANE BARRIER OVER 5/8" EXTERIOR GRADE PLYWOOD SHEATHING TERRAZZO FLOOR FINISH CONCRETE SLAB. RE: STRUCTURAL CEMENT BOARD BELOW GWB ABOVE A6.1 5 ONE LAYER HIGH DENSITY POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER MEMBRANE BARRIER OVER 5/ 8” EXTERIOR GRADE PLYWOOD SHEATHING 11' - 0" PRESSURE TREATED PLYWOOD4' - 0"ADHERED MANUFACTURED STONE VENEER PRE-CAST ADHERED MANUFACTURED STONE WATERTABLE/SILL 8" METAL STUD (TYP.)RE: STRUCTURAL STEEL BEAM RE: STRUCTURAL INSULATE VOIDS AT BEAMS R30 BATT INSULATION ( TYP.)LIGHT FIXTURE RE: ELECTRICAL SINGLE PLY ROOFING SYSTEM OVER RIGID INSULATION ( TYP.)RE: ROOF PLAN, SHEET A3 STEEL BEAM RE: STRUCTURAL 1/2" GWB TO UNDERSIDE OF DECK 2" 5/8" EXTERIOR GRADE FIRE RESISTANT PLYWOOD SHEATHING AT ENTIRE WALL SURFACE BEHIND SIGN.A3.1 17 FILLER 1/ 2" TERRAZZO CONC. SLAB ON VAPOR BARRIER SIDEWALK CAULK WITH SIKAFLEX SL ADHERED MANUFACTURED STONE VENEER LAP HIGH DENSITY POLYETHENE BARRIER OVER FLASHING 30# ELASTOMERIC SELF- ADHERING MEMBRANE. WRAP 12" UP SHEATHING AND 6" DOWN FOUNDATION FOUNDATION. RE: STRUCTURAL 8" METAL STUDS 1' - 0" PVC WEEP SCREED, COLOR: WHITE CONT. MTL FLASHING W/ HEMMED EDGES (HOLD FROM FRONT OF STONE 1/4" MIN.) SET IN A BED OF SEALANT 3. 4# SELF-FURRING GALV. METAL LATH AND LATICRETE PREMIUM MORTAR BED. EXTEND TO FOUNDATION 4" REQUIRED @ GRADE CONDITION LATICRETE MASONRY VENEER MORTAR LATICRETE AIR & WATER BARRIER 2"LAYER OF HIGH-DENSITY POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER MEMBRANE OVER 5/ 8" EXTERIOR GRADE PLYWOOD SHEATHING 1/2" TERRAZZO CONC. SLAB ON VAPOR BARRIER ADHERED MANUFACTURED STONE VENEER OVER ONE LAYER HIGH DENSITY POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER MEMBRANE BARRIER OVER 5/8” EXTERIOR GRADE PLYWOOD SHEATHING LAP HIGH DENSITY POLYETHENE BARRIER OVER FLASHING STEEL COLUMN RE: STRUCTURAL SELF- FURRING GALV. LATH & SCRATCH COAT. EXTEND TO FOUNDATION 30# ELASTOMERIC SELF ADHERING MEMBRANE WRAP 12" UP SHEATHING AND 6" DOWN FOUNDATION PVC WEEP SCREED, COLOR: WHITE CONT. MTL FLASHING W/ HEMMED EDGES (HOLD FROM FRONT OF STONE 1/4" MIN.) SET IN A BED OF SEALANT TYP.2" SIDEWALK CAULK WITH SIKAFLEX SL 4" REQUIRED @ GRADE CONDITION PRE- CAST ADHERED MANUFACTURED STONE WATERTABLE/SILL ALUMINUM STOREFRONT W/ SPANDREL GLASS PANEL SEALANT QUARTZ "COARSE CARRERRA" SILL BY CABINET VENDOR CASEWORK OUTLINE. RE: SHEET EQ.HSS 8x4x3/ 16.RE: STRUCTURAL 8" METAL FRAMING 1/ 2" GWB R-30 BATT INSULATION CAULK & BACKER ROD. MATCH STOREFRONT CAULK COLOR SIMPSON A-21 OR MIN. 22 GA. CONT. MTL SUPPORT BRACKET W/ HOLDING CAPACITY 5 LBS/LF. SIMPSON A-21 BRACKETS SHALL BE SPACED AT 16" O.C. OR (2) BRACKETS PER SILL PIECE. BRACKETS SHALL BE ATTACHED USING GALVANIZED SCREWS, PENETRATING STUD MIN 1" BRAKE METAL TO MATCH STOREFRONT ONE LAYER HIGH-DENSITY POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER MEMBRANE ON 5/8" EXT. PLWD SHEATHING LATH / SCRATCH COAT ADHERED MFD STONE VENEER T.O. SILL 3' -0"A. F. F.3/4" 1/2"ACROVYN EDGING WHERE GLAZING FRAME IS FLUSH WITH SHEATHING ACROVYN BREAKSHARP EDGES W/ R1/ 8" ROUND-OVER CAULK & BACKER ROD. ( MATCH STOREFRONT CAULK COLOR) SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDDRAWNDATEPROJECTNO.COPYRIGHT © - All reports, plans, specifications, computer files, field data, notes and other documents are instruments of service prepared by: Cuhaci & Peterson, (C & P) as instruments of service remain the property of C & P. C & P shall retain all common law, statutory and other reserved rights, including the copyright thereto. Any use or reproduction of this document without written permission from C & P is aviolationof Federal copyright laws.4/ 16/2020 12:07:14PMA6.1218071904- 17-2020S.G.A.D. M.WALL SECTIONS AND DETAILSORANGEAVE. & KINGS HWY, FT. PIERCE, FLWAWA260 WEST BALTIMORE