Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5380-F85FB-v20.0 - Sheet - A8-1 - INTERIOR ELEVATIONS
EXITA8.1 5 2 3 4 A8.1 8 9 6 7 A8.2 7 69 8 4' - 2 1/2"3' - 2"4' - 8" 4' - 7"3' - 6 1/2"2' - 8" 1' - 6"4' - 6 1/2"4' - 6"1' - 6" 1' - 3"5' - 7" 1' - 6"5' - 4 1/2"2' - 7"1' - 4 1/2" CLR FLR SPACE 30" X 48" CLR FLR SPACE 60" X 56" 6 14 2 1 16 9 BELOW CLR FLR SPACE 30" X 48"8 10 4 7A 3 13 15 1 4 3 7BELOW 5 12 5 5 17 10 13 2 CLR FLR SPACE 60" X 56" CLR FLR SPACE 30" X 48" CLR FLR SPACE 30" X 48" 8CLRFLR SPACE 30" X 48" 4 7A 3 1 4 3 7BELOW 1 15 10 12 6 14 2 16 BELOW 5 5 13 16BELOW 3' - 0" 4' - 4"2121 A8. 2 12 10 1113 WOMEN' S RESTROOM 23 MEN' S RESTROOM 24 REAR VESTIBULE 34 BARRIER FREE NOTES TOILET ROOM TO COMPLY WITH ALL BARRIER FREE DESIGN REQUIREMENTS INCLUDING BUT NOT LIMITED TO:A. GRAB BARS : TOP OF GRIPPING SURFACES ON GRAB BARS WILL BE 33"-36" ABOVE FLOOR AS SPECIFIED ON SHEET AC1 B. MIRROR : (1) 24 X 36", BOTTOM AT 40" A.F.F. MAX. AT EACH LAVATORY.C. LAVATORY : RIM HT. 34" MAX. A.F.F; BOTTOM OF APRON 27" MIN. A.F.F. LEVER HANDLES ON FAUCETS, IF APPLICABLE. INSULATE HOT WATER SUPPLY AND DRAIN PIPES. ALL PIPES BELOW LAVATORIES WILL BE INSULATED OR CONFIGURED TO PROTECT AGAINST CONTACT IN ACCORDANCE TO SECTION 606. 5 FBCA D. DOOR : 36" WIDE WITH PUSH/PULL HARDWARE AND SIGNAGE.E. URINAL : MAXIMUM CLEARANCE TO RIM OF URINAL IS 17" AS SPECIFIED ON SHEET AC1.F. WATER CLOSET : RIM TOP AT 17"-19" A.F.F. AUTOMATIC FLUSH CONTROL G. TOILET PAPER DISPENSER : CENTERLINE OF TOILET PAPER DISPENSER WILL BE 7"-9" FROM THE FRONT OF WATER CLOSET H. PAPER TOWEL & OTHER DISPENSERS : 48" MAX HT A.F.F. TO LINE OF OPERATION.I. N/A J. BARRIER-FREE:PROIVE 32" MIN. CLEAR OPENING AND SELF-CLOSING DOORS FOR ACCESSIBLE STALLS.RE: SHEET AC1 FOR ACCESSIBILITY REQUIREMENTS GENERAL NOTES 1. ALL DIMENSIONS SHALL BE TO FACE OF FINISH U. N.O.2. INSTALL A BEAD OF CLEAR SILICONE AROUND ALL TOILET SENSORS AND ESCUTCHEON RINGS. 2" 4 7A 14 36 9 13 8 2 14 6 2 8 13 TILE TYP FOR ALL WALLS. RE: TILE PATTERN SCHEDULE, DETAIL 26/ A8. 1 4 3 16 1 7 2" A8. 1 29 3" 3"4 S-2 PL- 1 15 3 GT1 PROVIDE FIELD TILE (CT3) BEHIND MIRROR. ENSURE THAT MIRROR COMPLETELY CONCEALS FIELD TILE 7 82 P6 FRAME2" 12 ACRC DOOR FA HORN/ STROBE 7' - 0"13 2" TILE TYPICAL FOR ALL WALLS SEE TILE PATTERN SCHEDULE DETAIL 26/ A8. 1 14 6 2 13 12 FA HORN / STROBE P6 FRAME ACRC DOOR 15 1 54 8 14 6 2 13 3 7A 2"15 1/4" 4 3 16 1 S- 2 PL- 1 7 3"3" A8.1 29 4 3 8 S- 2 PL-1 7 PROVIDE FIELD TILE (CT3) BEHIND MIRROR. ENSURE THAT MIRROR COMPLETELY CONCEALS FIELD TILE RB3 F3 F1.5 METRO WIRE SHELVING SYSTEM DASHED LINE INDICATES 1/2" DUROCK AT BASE OF WALL TO 48"HEIGHT AND 1/ 2" PLYWOOD ABOVEDUROCK BEHIND WALL MTD SHELVES. 2x12 BLOCKING BETWEEN STUDSDUROCK4' - 0" PLYWOOD4' - 0" 5' - 3" 1' - 2"FRPC HORN STROBE RB1 FRPC RB3 FRPC AIR CURTAIN RE: MECH OCCUPANCY SENSOR P6 DR & FRM ALARM PULL STATION D2 FRPC RB3 SURGE TANK ON FRP- WRAPPED SHELF RE: DETAIL 8/A9 CSR UNIT RE: PLUMBING D2D1D1 DUPLEX RECPT.DATA RECPT.2' - 0" 3"4' - 0" 6"GT1 EF- 1 27 A8.1 P6 CT3CT3DUROCK4' - 0" MR GYP BOARD4' - 6"PROVIDE DUROCK UP TO 4'-0" ALL WALLS OF RESTROOMS EPOXY FLOORING W/ INTEGRAL COVE BASE 1/ 4" DUROCK CEMENT BOARD SCHLUTER JOLLY LIGHT BEIGE FOR 3/8" TILE TILE FINISH SCHLUTER JOLLY LIGHT BEIGE FOR 3/ 8" TILE 1/2" M.R. GWB 1" TO 1-1/2" PARTITION LEG ACCENT TILE PER ELEVATIONSFLUSH3" 1/2" DUROCK CEMENT BOARD FIELD TILE PER ELEVATIONS PLAN @ TILE SECTION @ EPOXY BASE 1/2" DUROCK CEMENT BRD EPOXY FLOORING W/ INTEGRAL COVE BASE 1/4" DUROCK CEMENT BRD SCHLUTER JOLLY LIGHT BEIGE FOR 3/8" TILE 1/ 2" THICK CORIAN PANEL TO MATCH VANITY GLUED TO DUROCK RECESSED HAND DRYER WALL TILE, CT3 SEALANT SCHLUTER JOLLY, COLOR: LIGHT BEIGE FOR 3/ 8" TILE 1" 6" OPEN D2 D2 RB1 FRPCFRPC FRPC RB1 D2 D11 D2 TYP. F3 F5 B19 B21 RB3RB3 FRPC OPEN TO FOOD SERVICE D2 D2 D2 D2 RB1 TRASH BAG HOLDERS CO2 ALARM AND WARNING SIGN BY CO2 SYSTEM VENDOR AIR CURTAIN RE: MECH. DUPLEX RECPT. CO2 SENSOR BY CO2 SYSTEM VENDOR. G. C. TO PROVIDE PROTECTIVE CAGE GUARD BY SAFETY TECHNOLOGY INTERNATIONAL #STI- 9621 WATER HEATER DISCONNECT FRPC ALARM STROBE MOP RACK MOP SINK 2' - 0"2' - 0"WATER HEATER ON 30"x30" x4" H PRE- FAB CONCRETE PAD WIDTH - 8" HEIGHT - 6"1. SIGNAGE SHALL COMPLY WITH NFPA-55 CHAPTER 13 REQUIREMENTS. 2. SIGNAGE TO BE FURNISHED AND INSTALLED BY CO2 SYSTEM VENDOR. NOTES:OPEN TO FOOD SERVICE G2 D2 FRPC RB1 SOAP AND PAPER TOWELDISPENSERS TO BE FINISHED BLACK RE: A9/A9 FOR MOUNTING HEIGHTS SPECIAL PURPOSE RECPT F5 B21 B19 F5 B19 B21 RB1 FRPC 2' - 3"9" 6" MIN. ELEVATION SECTION 8" MIN. 1' - 8" COUNTERTOP TO BE ONE PIECE2' - 6"PROVIDE CORIAN FINISHED END AND BACKSPLASH AT WALLS 2' - 9 1/ 2" COUNTERTOP AND CABINET BY CABINETRY MFR. REMOVEABLE PANELS OFFSET TAILPIECE RE:PLUMBING AIR CURTAIN RE: MECH FA PULL STATION FRPC RB1 P6 DR & FRM RB1 MOUNT BUG LIGHT DIRECTLY OVER RECPT. SO POWER CORD IS CONCEALED RE: ELECTRICAL FRPC DUPLEX RECPT. 5' - 6"OPEN DUPLEX RECPT.OCC. SENSOR FRPC FIRE EXSTINGUISHER SURGE TANK ON FRP- WRAPPED SHELF RE: DETAIL 8/ A9 BNB SHELF RB3 P6 FRAME ACRC DOOR D1 FRPC RB1 P6 DR & FRMWATER HEATER ON 30" x30"x4"H PRE-FAB CONCRETE PAD CO2 ALARM AND WARNING SIGN BY CO2 SYSEMVENDORRB1 FRPC ACRS DOOR P5 FRAME RB1 FRPC D2 D11D2RB1 FRPC FRPC D2D2D2 D11 FRPC RB1 WALK-IN REFRIGERATORFINISH: WHITE SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDDRAWNDATEPROJECT NO. COPYRIGHT © - All reports, plans, specifications, computer files, field data, notes and other documents are instrumentsofservice prepared by: Cuhaci & Peterson, (C & P) as instruments ofserviceremain the property of C & P. C & P shall retainallcommon law, statutory and other reserved rights, including the copyrightthereto. Any use or reproduction of this document without written permissionfromC & P is a violation of Federal copyrightlaws.4/ 16/2020 12: 08:42 PMA8.1218071904-17-2020S. G.A.D. M.INTERIOR ELEVATIONSORANGE AVE. & KINGS HWY, FT. PIERCE, FLWAWA260 WEST BALTIMORE PIKEWAWA, PENNSYLVANIA 19063WAWAF85FB2020. 00 STORE #5380-ORN04/ 17/2020 3/8" = 1'- 0"A8.1 1 PUBLIC RESTROOM ACCESSORIES DIAGRAM1/4" = 1'-0"A8. 1 2 WOMEN'SRESTROOMELEV. 1/4" = 1'- 0"A8.1 3WOMEN'S RESTROOM ELEV.1/ 4" = 1'-0" A8.1 4 WOMEN'S RESTROOM ELEV.1/4" = 1'-0"A8.1 5 WOMEN'S RESTROOM ELEV.1/4" = 1'-0"A8.1 7 MEN'S RESTROOM ELEV.1/4" = 1'-0"A8.1 6 MEN'S RESTROOM ELEV.1/4" = 1'-0"A8.1 8 MEN'S RESTROOM ELEV.1/4" = 1'-0" A8.1 9 MEN'S RESTROOM ELEV.1/4" = 1'-0"A8.1 10 WASHROOM ELEV.1/ 4" = 1'-0"A8.1 24 DELIVERY VESTIBULE 1/4" = 1'-0"A8. 1 23 DELIVERY VESTIBULE 3/8" = 1'-0"A8.1 26 RESTROOM TILE PATTERN LAYOUT 3" = 1'-0" A8.1 27 RESTROOM COVE BASE 3" = 1'-0"A8.1 31 CORIAN PANEL DETAIL 1/ 4" = 1'-0"A8.1 13 BACKROOM ELEV.1/4" = 1'-0"A8.1 15 BACKROOM ELEV.1/4" = 1'-0" A8. 1 17 STAGING ELEV.RESTROOM ACCESSORIES SCHEDULE ITEM MANUFACTURER MODEL # REMARKS SUPPLIED BY 1 ELECTRONIC HAND DRYER EXCEL DRYER INC. XLERATOR XL-C CHROME ELECTRONIC HAND DRYER WITH RECESSED KIT HJC 2 T.P. HOLDER - - 7" MIN - 9" MAX IN FRONT OF WC. OUTLET 19" A.F.F.HJC 3 SOAP DISPENSER TORK 571608 BLACK TOUCHLESS ELECTRONIC SOAP DISPENSER - BATTERY OPERATED HJC 4 MIRROR BRADLEY 780-2436 24" X 36" MIRROR WITH S.S. FRAME IN SATIN FINISH.HJC 5 COAT HOOK BOBRICK B-233 STAINLESS STEEL WITH SATIN FINISH MOUNT HJC 6 42" GRAB BAR BRADLEY 8120-00142 STAINLESS STEEL WITH SATIN FINISH, BOTH RAILS 42" IN LENGTH HJC 7 LAV CABINET CABINET - CABINET BELOW LAVATORY SUPPLIED AND INSTALLED BY CABINET VENDOR. COORDINATED BY GC.CABINET 7A LAV SHIELD TRUEBRO 2018-AS-L FOR AMERICAN STANDARD "LUCERNE" LAVATORY HJC 8 TOILET PARTITION SCRANTON BRADMAR - M244 CANYON GRANITE SOLID PLASTIC PARTITIONS ( NO SITE LINES) W/ S.S. PRIVACY SLATS, AND SELF-CLOSING DOORS. PROVIDE PULLS ON BOTH SIDES OF ADA STALL DOOR.HJC 9 NAPKIN DISPOSAL UNITBRADLEY4722- 15 STAINLESS STEEL WITH SATIN FINISH. WOMEN'S ROOM ONLY. HJC 10 WALL BRACKET BRADLEY - MOUNT ON TOP RAIL WHERE PARTITIONS MEET WALL HJC 12 ECONOMIZER DISPENSER MICROBURST 9000 4013752UNITS PER RESTROOM, 1 NEAR DOOR AND 1OPPOSITE. TOP 2" MIN FROM CEILING WAWA 13 TOILET SEATCOVERDISP. - - ONE PER STALL HJC 14 18" GRABBARBRADLEY 8120-00118 STAINLESS STEEL FINISH. MOUNT RAILVERTICALLY.HJC 15 WASTE RECEPT. BOBRICK B-3644 RECESSEDINTOWALL - 4" WALL RECESS REQUIRED, 4" PROTRUDING BINHJC16 SOLID SURFACE PANEL DUPONT CORIAN COLOR: COTTAGELANE1/ 2" THICK, 14- 3/4" WIDE X20" HIGH PANEL MOUNTED 6" A.F.F., LOCATEDBELOWHAND DRYER. SEE DETAIL