HomeMy WebLinkAboutProduct Approval + I
V/
MIAMI•DADE MIAMI-DADE COUNTY
a FRe COPY PRODUCT CONTROL SECTION k
11805 SW 26 Street,Room 20&'<�tr..'
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRAT ION T 786)315-2590 F 786)315-2599
CCEP NCE A ( vw.miamidade. ay/economy
Labrador&Fundora Corp dba V&V Windows
2355 W 4t''Avenue DE COMPL�,IANCE.C®
Hialeah,FL 33010-1454 �-�o CIE CO��
SICOPE: """' .... �C 6�j�.
is OA is being issued under the applicable rules and regulations govemin t9e t see of construct ion materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In
Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
Tliis product is approved as described herein and has been designed to comply with the Florida Building Code, including
the High Velocity Hurrican one.
DESCRIPTION Series "300" Outswin Glazed Aluminum DooryNlwo r door w/wo Transom-LMI
�dM.LL tSEi.ffi'.L'9:RiTMP88�8"
APPROVAL DOCUMENT: Drawing No. W10-08 Rev I, titled "Series Aluminum Out—Swing Entrance Door
(L 1,M.I.)", sheets 1 through 12 of 12, dated.02/24/10 and last revised on 082420, prepared by Al—Farooq Corporation,
signed and sealed by Jalal Farooq, P. E., bearing the Miami—Dade County Product Control Revision stamp with the
'Lcc�eef ncc m, i,mber xpirat„i e b 1�ia�i—Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact
1. See Design Pressure(DP)ratings in sheets 2,3,4& 5 for unit sizes Vs glass type.Lower Design Pressure from
doors, sidelites or mullion shall control when doors are mulled(w/wo Reinforcements).
2. Door w/transom is limited to max. 25-1/2"h Transom.
3. Glass lite wider than 36" shall be supported with approved setting blocks or clamps per FBC requirements.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and
follll wing statement: "Miami-Dade County Product Control Approved",noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the!applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if.there has been a revision or change in the
materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADS RTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in
its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
ThQI NOA revises& renews 17-1011.02 consists of this page 1 and evidence pages E-1,E-2 and E-3,as well as approval
document mentioned above.
The isubmitted documentation was reviewed by Ishaq I. Chanda,P.E.
NOA No. 19-0326.09
iaMN�anECOUL rr Expiration Date: September 10,2025
i Approval Date: September 10,2020
Page 1
i
I
Labrador& Fundora Cora dba V&V Windows
r �
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
.I
i
1. EVIDENCE SUBMITED UNDER PREVIOUS NOA'S
A. DRAWINGS
1. Manufacturer's die drawings and sections (Submitted under files below).
2. Drawing No. W10-08 Rev F,titled"Series Aluminum Out—Swing Entrance Door
(L.M.I.)", sheets 1 through 12 of 12, dated 02/24/10 and last revised on SEP 03, 2015,
prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad,P.E.
B. TESTS (Submitted under files#12-0113.02/#10-0406.04)
1. Test reports on 1)Air Infiltration Test,per FBC, TAS 202-94
2)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3)Water Resistance Test, per FBC, TAS 202-94 (+50.0 PSF, sill S-1 only)
4)Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6)Forced Entry Test,per FBC 2411 3.2.1, TAS 202-94
along with marked—up drawings and installation diagram of an Aluminum outswing French doors
w/wo sidelite and door w/Transom& sidelites,prepared by American Test Lab of South Florida,
Inc., Test Report No. ATLSF4403.0248, dated 01/18/10, signed and sealed by William R.
Mehner, P. E., Henry Hattem, P. E. and Edmundo J. Largaespada, P. E.
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC-2014(51h
Edition),prepared by Al Farooq Corporation, dated 02/18/15 and last revised on AUG 13,
2015, signed and sealed by Javad Ahmad,P.E.
2. Glazing complies w/ASTME-1300-02, 04 and -09
D. QUALITY ASSURANCE
1. Miami Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 14-0916.10 issued to Kuraray America,Inc. (former E.I.
Dupont) for their"Butacite®PVB Glass Interlayer", expiring on 12/11/16
F. STATEMENTS
1. Statement letter of conformance to FBC 2014(5th Edition) and letter of no financial
interest,prepared by Al Farooq Corporation, dated 02/11/15, signed and sealed by Javad
Ahmad, P.E.
2. Lab compliance and addendum letters, as part of the above referenced test reports.
3. Asset purchase agreement dated July 28, 2009, signed by Mr. David Labrador and Mr.
Candido D. Vega. (Submitted under previous NOA No. 10-0406 Ad l
Ishaq I.Chanda,P.E.
Product Control Unit Supervisor
• NOA No 19-0326.09
Expiration Date: September 10,2025
Approval Date: September 10,2020
• ''I E-1
II
I
I
Labrador& Fundora Corn dba V &V Windows
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
F. STATEMENTS (continued)
4. Florida Department of State, Div of Corporation, active listing of Labrador & Foundora
Corporation, dated 05/07/19985.
5. Florida Department of State, active fictitious name listing of V& V Windows, dated
08/13/15.
G. OTHER
1. This NOA revises & renews# 12-0113.02, expired on 09/01/15.
2. Test proposals#07-3564 &test proposal dated 10/20/08 approved by BCCO.
2. EVIDENCE SUBMITED UNDER PREVIOUS NOA(s)
A. DRAWINGS
1. Drawing No. W10-08 Rev G,titled"Series Aluminum Out—Swing Entrance Door
(L.M.I.)", sheets 1 through 12 of 12, dated 02/24/10 and last revised on 03/29/17,prepared
by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E.
B. TESTS
1. None.
C. CALCULATIONS
1. Anchor verification calculations and structural analysis., complying with FBC 511 Edition
(2014) and FBC 6th Edition (2017), prepared by Al Farooq Corporation, dated 09/25/17,
signed and sealed by Javad Ahmad, P.E.
D. QUALITY ASSURANCE
1. Miami Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America,Inc. for their
"Trosifol®Ultraclear, Clear and Color PVB Glass Interlayers", expiring on 07/08/19.
F. STATEMENTS
1. Statement letter of conformance-to FBC 511 Edition (2014) and FBC 611 Edition(2017)
and letter of no financial interest,prepared by Al Farooq Corporation, dated 07/10/17,
signed and sealed by Javad Ahmad, P.E.
G. OTHER
1. This NOA revises # 15-0310.05, expiring on 09/01/2020.
Ishaq I.Chanda,P.E.
Product Control Unit Supervisor
NOA No 19-0326.09
Expiration Date:September 10,2025
Approval Date: September 10,2020
E-2
Labrador& Fundora Corn dba V&V Windows
i
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
i
3. NEW EVIDENCE SUBMITED
A. DRAWINGS
1. Drawing No. W10-08 Rev I,titled"Series Aluminum Out—Swing Entrance Door
(L.M.I.)", sheets 1 through 12 of 12, dated 02/24/10 and last revised on 082420,prepared
by Al—Farooq Corporation, signed and sealed by Jalal Farooq, P. E.
B. TESTS
1. Test reports on 1)Air Infiltration Test,per FBC, TAS 202-94
2)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94
3) Water Resistance Test,per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test,per FBC 2411 3.2.1, TAS 202-94
along with marked—up drawings and installation diagram of an Aluminum outswing French doors
w/sidelite(OXX),prepared by Fenestration Testing Lab, Inc., Test Report No. FTL 9329, dated
12/07/18, signed and sealed by Idalmis Ortega, P. E.
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 71h Edition
(2020), prepared by Al Farooq Corporation, dated 06/24/20, signed and sealed by Jalal
Farooq, P.E.
D. QUALITY ASSURANCE
2. Miami Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 19-0305.02 issued to Kuraray America,Inc. for their
"Trosifol®Ultraclear, Clear and Color PVB Glass Interlayers", expiring on 07/08/24.
F. STATEMENTS
1. Statement letter of conformance6orporation,
BC 7th Edition (2020) and le r of no financial
interest,prepared by Al Farooq dated 06/24/20, si d and sealed by Jalal
Farooq, P.E.
G. OTHER
I. This NOA revises & renews # 17-1011.02, updates to FBC 2020, expiring on 09/10/2025.
Ishaq I. Chanda,P.E.
Product Control Unit Supervisor
NOA No 19-0326.09
Expiration Date: September 10,2025
Approval Date: September 10,2020
E-3
\ 3/16"TEMP. GAS �� i i
m
\ --1la"AIR SPACE o
—1/8'HEAT TIP.EN'D CUSS ^Mo.." HEAT STREN'D GLASS \ 1� —3/1V HEAT STREN'D CLASS F,taj
�' nI
\ 090, Intcrlayer \ ,090" Interloy=r \ ` 090" IntoHayer ♦� cep Q[
s—Treatla PVB % Tmsifol P'V8 \ �`� �Trcallol PVB N:
` ey 'Kuromy Amerce, Inc' T By 'Kurorgy America, Inc.' `� `\By'kurocny Amer:ro, Inc.'
`t1 r•1/8"HEAT STREN'D GLASS ' r3/16" HFAi STREN'D GLASS \ \l`� '-3/16-HEAT S.TREN-D GLASS N ice'
,•'•\ t. SIUCONE \ `' ,1 SNE
�DOWS!L 995 - IUCO\ •,. ` DO'r✓;IL 995 ! \ •t °IUCANE ( t
itu i• , i' PECORA 995 Z i� PECORA 895 z I l\�•':\i rDOWSiL 899 t 0Hj
.r .F
@ � `20� �• f' �. � �20f ', !M1 �. (26� \ I :1 :.� \ i p i r C)4 F_tt
_.. J ,y.,.�_
_UURASEAL SPACER /
BY 'QUANEX, SETTING BLOCKS c
NOTCH GLAZING BEAD L
m(U-1 F .01 LEAF TO CLEAR BLOCKS -- m
GLASS TYPE 'H' S G1ti$ �_ �' CY �I
5/1.6.'OVERALL_LAM. GIASS 7/16"OVERALL LAM.GLASS 7/8 OVERALL.INSUL..LAM.CLASS �t
z
PRODUCT REVISED a
Z 9 .o.
s !tl z iC, as compbing with the Florida ' V
m Building CCodda cs E!m
f 0 ,AT 1/4 POINTS Ott LiTES Z�� - rioa rio. 19 0326.09 -
20 }.. WIDER THAN 3e ONLY — I i.�! z. e c¢u
rn \ Expiration Date:09/10/2025 I 1 z
AI UNUNTI;Ki�i1'I"�OFt3tiG EIN A\ 'F I3�0� 1 ----- I r i r z o �> m
Miami-Dada Product Control L d
SINGLE (X) AND DOUBLE ()X) LEAF DOORS W/O TRANSOM SEE SHEET 2, >3 r 3
SINGLE.(O/X) AND DOUBLE (O/XX) LEAF DOORS WITH TRANSOMS SEE SHEET 3. 7 I m ° I n o
SINGLE (0) SIDELJT'E SEE SHEET .4, I / o n° s-,a
SINGLE AND DOUBLE LEAF DOORS NVITH. SIDEL.ITES SEE SHEET S, \' ,C1) f/ \ v /
LOWER VALUES FROM DOOR CAPACITY CAHRT, SIDELITE CAPACITY CHART OR 21s ir '
SIDELTE MULLION CAPACITY CHART WILL APPLY TO ENTIRE SYSTEM. \
EI -1
DOORS APPROVED FOR INSTALLATIONS WHERE WATER INFILTRATION ._til�T'It'fiE/TrL,-�y;;.yh� Stn.Flp •; °s
RESISTANCE IS REQUIRED. GLASS TY S 'A' & 'B' ONI, G 49S T F 'C'
o P
THIS PRODUCT HAS BEEN DESIGNED AND TESTED T0.COMPLY WITH THE I a
REQUIREMENTS OF THE 2017(BIN EDITION)/2020 (7TH EDMON) FLORIDA GLAZING OPTIONS c"
SUiLDiNG CODE INCLUDING HIGH VELOCITY HURRICANE ZONE(NVHZ). !`n ,
TBY OR 2BY WOOD BUCKS& BUCK FASTENERS BY OTHERS, MUST 9E
DESIGNED AND INSTALLED ADEOLATELY TO 7RANSTR APPLIED PRODUCT LOADS i I
D
TO THE:9UILDING STRUCTURE,. s �
ANCHORS SHALL:BE CORROSION RESISTANT', SPACED AS SHOWN ON DETAILS
AND INSTALLED PER MANUP'S ItJSTRUCT(ONS, SPECIFIED EMBEDMENT TO BASE THESE DOORS kRE RATED FOR LARGE& SM+tU_ MISSILE IfdPn`CT, l�io u
SHUTTERS ARE NOT REQUIRED. >, mo
MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO.
A LOA T I 15 USED 1N 0)S1('N nF ANryGI 0 ONLY• ��isnittrl�
AIL SHIMS TO BE HIGH IMPACT, NON-METAI.IC AND NON COMPRESSIBLE.
COMFiN70 ON
WI ALL MEET THE
REOUIREMENTS OF TH 20 7/2020 F,LOR1 ADOPTED STANDARDS. F2O 83223 o ��
THIS PRODUCT APPP. Jc A1J0 DOES NOT PROVIDE 1N'DRMAITON
FOR A SITE SPECIFlC PROJrCT r.e LlFE SAFELY OF'I IS PRODUCT,ADEQUACY
OF STPUCTURE RECEIVING TI115 PP,ODUCT MtD SEALING AROUND OPENING FOR
WATER INFILTRATION RES! TARCc.ETCH drCt<Ing no. i
CONDITIONS NOT SHOWN IN THIS.DRAWING ARE TO BE ANALYZED SEPARATELY, t� J
AND TO BE REVIEWED BY.BUILDING OFFICIAL, E Q`a•, .^ 'rf�j" W�Q^d$
�i°,� 1
DESIGN LOADS SHOV/N ARE BASED ON 'ALtOPlA9CE STRESS DESIGN (ASD)'. Sealed:8/24/20 �\rir 'ie-:s.
A?1tLit;ise� sheet 1 ofT2t
MAX ... ., .. \
. 76"MAX
__._r._�..-'_._ ..�.... E
FRAME WIDTi-4� : FRAME WIDTH
12 i 12 0
5"MAX _ I ,•-r. MAX.. �5'MAX. ..MAX.. .
HEAD SILL (.� �' HE4Q/SILL \A. 1 HEAD
pORNERS 1, ,SILL - SILL
.CORNERS
T I w I } SILL AN
A do t STILE
it
..A STILE ENDS I1 B.Gi
I'. JJ ' f i 'I JJ I ; I wsH i (4)AT 3"G.G.BOLT
IP
I -r
C L. - �� \ I i F \ HINGE OPTIONS.
I - / if 4_/ i I .. �n I / €i LE�' -• \ EE SHEET .10 €OIr
4'�
If I €EIC
F J—
it
_ ---tt-�_ LOCK OPTIONS\
--- I1.z
i I s I. N1'.OR #2 '
/_
• r" o -° #. u: I i. .. s : Ci .2 0 J yj i �. '(OPTION 11 SHO , ' m' I €
SEES iD N4
PRODUCT REVISED
Q, i ,e=._e r __❑ F I I LL- m', I i C _-,efL- !f / ! as complying with the Florida
Building Code rv.
LOCI,(OPTION .� �ff
\ it } n € i / Non-N -0326.09 r
E N #1 OR$2 o. 19 ,
(OPTION 1 S OWN) \\ Expiration Date:09/1012025 i
\.1 L SEE SHEET 10 By;—.isi..zi.';r/,�,�.:
g.
Miami--Dade Product Control
FLUSH
€€ d ACTNE INACTIVE
•p�p o
ACTNE.. --. .. -
7 I ? - j ate., a T H.i
12
SURFACE APPLIED SURFACE APPLIEQ' / ( _. _
FALSE MU NS i0R , e o FALSE>MUNTIWS'OR'_„/ ,� �,4 a iL
OECORATI GRILL I ZB 3/4 MAX fl "`O � DECORATBlE CRILL 26 3/A"MAX ' i- 26 3/4 MAX a tOi' moo.
MAY BE.USED -----•- -----i MAY BE USED' t,._ .. __...,,•j y F„I.-___- _
D.L.OPC 3 O.L. OPG , Q.L S.'BL EA3F/4W IDMTHX J�t.3
ti
' D �-LEAF VATH
"F;
..73_ MAX..._.._............_w_.....�_
DOOR.OPNG.W. QOOR OPNG.WIDTH
(X) xx)'
DOORS GOAD CAPACITY PSF 'DOORS LOAD CAPACITY PSF
a
SINGLE DOORS TTITtiOU C TRANSOM',(X) DOUBLE. DOORS WITTTOUT TRANSOM (XX) �
CLASS TYPE GtA.SS TYPI; .GGAS9:TYPE - •GLASSTYPE GLAS3 TYPE GLASS.TYPE.. Z.I.�
N
a
d W
DOOR DIMS. _ 'A' '• 'B' 'C° DOOR D€MS, 'p`. •g• 'G• - t'a m rc .
FRAME LEAF FRAME LEAF _ FRAME- "LEAF FRAME' LEAF,
•MOTH. ..WIDTH HEIGHT HEIGHT[ �.(+), �Ui'f.(-) EXT.(+) ..TNT(;) �EXi.(+} INf.(-)' WIDTH ,VflDTW.t HEIGHT HEIGHT tn•(+) INT.H: -EXT-(+) INT.( ) EXr.(+) INT.(-:)
37--5/8" 34-3/4" : 70.0 .80A 70.0 600 80.0' 80:0 72" 34-3/4 ' 70.0: $0.0 70:0.
'86" 93-3/8" .. .... - .96" 93-3/8".. _. m
39-5/8: 36-3/.4" 66.3 76.8 66:3- 75.6 80,0: 80.0 : 78` - 36-3/4" '66.3 75.8'„ 66.3 78.8 •? o C O O O
.`Y�itlUlUl//T
DrL.O. HEIGHT =FRAME HEIGHT- 12" %� c
D.L.O.:,WIDTH (X DOORS) FRAME. WIDTH - 12.875" j 00'81223 o
NOTE: D.L.Q. WIDTH (XX 'DOORS). _ (FRAME WIDTH - 22.50")/2
GLASS CAPACITIES ON THIS SHEET AkE
BASED ON ASTM:E1300•=09 (3 SEC.=:GUSTS) +�' B tit l ,drawing iio.
AND FLORIM BUILDING COMMISSION n���tir W1 b•-d$
Sealed:
DECLARATORY STATEMENT DCA05-DEC 219'
..
. .. .. -.. TYPICAL ANCHORS .. ... EDGE DIST.. IBY
SEE ELEVATIONS: k .. WOOD BUC
METAL STRUCTURE
9/16`MIN EDC.F�DIST ,/ FOR SPACING e v I ' d
THROW BOLT F» :� (SEE ^^>PEC BELOW)
e, f Z Kyl/O6NQ.a' �.
PENETRATION
. - 3 KSI CONQ 1 . . 1 �o� O' tpp� a
- EDGE' EDGE DIST.
H.
.' •' I i � _`N. �' .... to � N _ in � V
lYCt
+ 1 I1 J \: �`-'•' TYPICAL ANCHORS TYPICAL ANCHORS TYPICAL ANCHORS
n M
{ } .?0 I, --SEE ELEVATIONS "-SEE,ELEVATIONS SEE ELEVATIONS g pG
j I FOR SPACING FOR SPACING :FOR SPACING
s .` y .
I 55'
vv �i I
WOOD BUCKS AND METAL STRUCTURE NOT BY V & V•WINDOWS:. FE tt
MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM
I :AND TRANSFER THEM TO THE BUILDING STRUCTURE.
. PRODUCT REVISED
as compyymgg with the Florida o ,
{ - Building Codo Q�
} YPICAI A)`ICI30U; SEE'ELEV:FOR SPACING NOA-No. 79-0326.09 W '
1 L4" D)A.ULTRACON+ 8Y :DEWALT' '(Fom16d KSI,Fy-4d KS Expiration Date:09N012025 z
1: I t INTO.2BY''WOOD BUCKS OR WOOD STRUCTURES. By
{{ I 1-.1./2 MIN.. PENETRATION INTO WOOD (HEAD/JAMBS) � J1, Miamt-Dodo Product Control
IXaoa
Is � ,, ; - I 1=I/4" MIN. EMBED INTO CONCRETE,(HEAO/JAMBS} �__ I 1 •� .,I..
� . f o: x Y
W r 1.-t%4" MIN. EMBED IN BLOCKS{JAMBS} T.
X DIRECTLY INTO,'CONCRETE OR BLOCKS
W i E 1 14 MIN EMBED IN70 CONCRETE.(HEAD'/SILL'/JAMBS}—T r`T Q f�` mew
`ew s
(. 1 1/4 MIN EMBED INTO BLOCKS (JAMBS)
i I , F. #fi4 SMS OR SEJ,F DRILLING:SCREWS:(GRADE 2 CPS)
INTO MIAMI-DADE COUNTY:APPROVED.MULLIONS
IIOR-
�+
INTO METAL STRUCTURES (HEAD/JAMBS) ` 2t
(3) THREADS MIN PENETRATION BEYOND SUBSTRATE
tt
ALUMINUM: 1/ 8 THK, MIN (6063-T5'MIN. g�- 2 8
STEEL: 1/8" THK. MIN. (Fy. ._ 36 KS[ MIN.) 0
(STEEL IN CONTACT WITH'ALUMINUM.TDB BE PLATED.,OR PAINTED) w 5,
v
.TYPICAL EDGE DISTANCE b T
MIN � SONRY ='2=•1 2' MIN;
I 4 TNROW HOLTZ / " WN-211
PENErrunDN t � , 1 �✓ INTo WOOD STRUCTURE '= t��'�wood AT HEAD OR JAMBS.sc = 0.66 MIN. DOfl.R DETAILS.:AZGI CONCRETE Ai HEAD. SILL'OR JAMBS fc .3G00 P§I MIN.C-90 HOLLOW/FLLED BLOCK AT JAMBS fm. 2000 PSI MIN.
-SEALANTS_: �������yydERt:��r ��� r •a
�! FRAME AND LEAF CO0NERS INStkl_I TION SCREWS AT SILL AND ALL "
-- - -r- :r METAL PARTS:'CONNECTIONS SEALED.`WITH PTI SILICONE. IN&M223 g
`Coble T�k = $ $
WEEPS� � ( 3 KSI. n ;$`
! TYPICAL ANCHORS 3/16" X 3/4" WEEP SLOTS`AT 3" FROM EACH END :: drewlrig no
EDGE Dist. � .>SEE ELEVATIONS
FOR SPACING OPERABLE UNIT Sealed:8/24/20 ,\\'���t �' �`:'
•i
_.. ��rrrrnuatri�� _, shaet'.g of12;1i;
MAX. 19Y.WOOD BUCK
SHIM SHIM (SEE'NOTE SHEET1,)
0
TYPICALANCHORS TYPICAL ANCHORS Ip
SEE ELEV .. SEE ELEV. �+
FOR SPACING} FOR SPACING
2O t - - mot ;E.... ;a
z5
w PRODUCT REVISED
as complying ydth the Florida O
Building o o 1,Q I NOA-No. 19-0326.09 g
1 I EL2TOR Expiration— Eiti Date.0 911 0/2 0 2 5
I �{N
�MEfaL I 1 ! 11 17A\ 6� D.L.O. q LJ I By:
STRUCTURE Miami-Dade Product Control
a I 36 3/4'MAX.: .. 4 � ..
Fes-- LEAF WIDTH - •--- LOCK-OPTIONS
\_1 DR 2'
I OPTION 7 SHOWN
36 5 B MAJt, -
�Q
SEE SHEET' 10 FOR)DESCRIPTION � ••
DOOR OPNG WIDTH �� o
Iry 39 5/8 MAX.
1/4 1 1
• 'MAX,
FRAME.WIDTH
T/¢ MAX. SHIM
n'
a
SHIM- E- rr
i CONCEALED FLUSH BOLTS _ 'a
COW
WfTHENR !
ONAL{:OCK
.TYPICAL ANCHORS :1 `LEVERS AT INSIDE FACE Of.SALE n :.
LL D(AD 20L7�
SEE ELEV ., WOOD tiC1<
FOR.SPACING t. ____. ..... -.... ... .._......................,..,.:.:.._ i�'`` _.. \OR'.. o N
ACTIVE LEAF INACTIVE LEAF FOOD UCTURE vv°ion
cca
0�; -^•� ;. .'_'`. '� S.f? tom•n
• oFL
- .
Pat
i .a ` � ! ...•.:. ?' t` ' r.. tea. ..
b.L.o. EXTEPCIO.R TYPICAL ANCHORS I `
1 �8, C_SEE ELEV.
L""r I FOR SPACING s
;....:.I. �' LEAF WIDTH. jc
- LOCK.OPAON #2 R
72-MAX
�... .. ....... .... _....,......._ .. 76"MAX: .......
FRAME WIDTH
PDINT LDCK ASSEMBLY CONCEALED.FLUSH BOLTS
3 %
`\ r^LEVERS AT INSIDE FACE 'SALE c m
t f' 4o%.�Y €�
a�Bsa
ACTIVE LEAF ,' INACTIVE. LEAF;.
LTT1ILt off
� ,W� z •
p�.•
�_ drawI ng no. .
EXTERIOR �� `� < ' W10-0$'
Lock OPTION #1 DOGR' DETAILS Sealed:8124/20
�,% lTtN NQL% sheet.::?.of 12
ITEM
f PART H BEQD DESCRIPTION�- ... .IdATERIAL Li{ANF/SUPPLTER/REMARKS I1. -
Us
1 V50/ 3/'DOOR FRAME HEAD/JAMB 6053-TO V&V SELECTED EXTRUDER. Eo
2. V502 ,. 1, FRAME.SILL. : 6063-T6 V&V SL1..EOTED.EXTRUDER.
3 V503 1 SILL COVER &V SELECTED EXTRUDER
4 V504 AS REQD. SIDELITE STILE 6063 T6 V&V SELECTED EXTRUDER
- _._._ _ __ _._.. I x
I
5 V505 2/LEAF TDP.AN BOTTOM RAIL so63-is., u&....... ED ExfxtIDER
6: Y506 t/LEAF HINGE STILE: 8683 T6...V&Y SELECTED EXTRUDER `
7 - N507 1/.LEAF LOCK AND ASTRAGAL STILE 6063 T6 V&V SELECTED EXTRUDER'.
8 V513 AS RE.DD. INACTIVE ASTRAGAL STILE __6O63-f6 V &V SELECTED EXTRUDER.., ,. q
9 V508 2/LEAF SWEEP ADAPTER 6063 16� V&V`S_EL_EC_TED DOLIDER
ff G
10 'V509 AS.REQD•'SIDELRE ADAPTER ., ' 6D63-T6; V&V;SELECTED EXTRUDER I d
11 V511 AS REQD. GLAZING BEAD 5/16:CLASS___.. 6063 T6 .V&V SELECTED EXTRUDER„.
11A - V517 AS RFAD.'GLAZING:BEAD_- 7/16"'CLASS :. 6053 T6:' V&V SELECTED EXTRUDER
11 B V521 . AS REQD. GLAZING BEAD='INSUL LAM.GLASS. i6063-T6- V&V:5 T -1_ EtEC F.D.FxTRDER i
12 V512 AS.REOD. REINFORCING'STIFFENER �80.153 T6 V&V SELECTED EXTRUDER
13. .2/ LEAF 3/8'THREADED-.ROD .. STEEL. ...
`15. 'V514 2/ LEAF FLUSH BOLT SUPPORT ANGLE '6663-T5 5 1/2-X 7 1/2 X.3/16 Q
17 - "3/LEAF BALL SEARING HINGE ASSEMBLY "' " '' " "' "' '
• - - '-
17A - 3/LEAF 3-:PIECE HINGE.ASSEMBLY -
' 18 AS'REQD SEITINC BLOCKS EPDMi DUROMETER 80±5 SHORE A
Y
p
19. - AS.,REQO FIN SEW.PILE:WEATHERSTRIPPING _ � 1
20 V516 AS READ. 9ULB.VIEATHERSTRIPPING. ., SANTCjPRENE,OVROMETER�80t5
21 :x 1/2 AS READ GLAZING'ADAPTER SCREWS ^'"ST STEEL PH TFXS,AT V FROM.ENDS&S"O C MAX.
22 #10 X.2 AS REOD FRAME ASSEMBLY SCREWS.. -ST STEEL.r PH SMS_
'i 23 AS.REOD; SIDE LATE AOAPTER.SCREWS .5T STEEL
24,, 00-32 X,1/2 2f:ANGLE SUPPORT ANC;LE:SCREWS'.' :"'sT STEEL'ETL MS ..... .... . ..". .:
25 .. ..AS,REQD.,BUMPER SPACER.... ..........SILICONE
36 V522 AS
REQD:'GIdDNG WEDOE - � EPDM. -.:DUROMMR,70t5,SHORE A......,... "
[<OCK9;
OP,II)N,./I7: OPTION N?;. U.3aM.
ACTIVE LEAF: ACRE LEAF r >
EALANS; 4
3 POINT LOCK ASSEMBLY BY'SULLIVAN AND ASSOC! CONVENTIONAL DOOR LOCKSEr WITH HANDLE ByAIYME5
7/1e°x 3-'THROW BOLTS At TOP.AND BOTTOM. !SULLIVAN AND ASSOC.? LOCATED Al 39'FROM ACL JOLNT5.AND FRAME CONREGTfONS SEALED WITH
ENGAGING FRAME AT AFRO AND SILL BOTTOM OPTLON #11 .PTI SILICONE.
THROW.SOUS ATTACHED TO""LOCK BY CONNECTING-RODS M.`OPERATED:ON EXTERIOR:AND THUMB TURN ON
LOCK LOCATED'AT 52-3/4' FROM BOTTOM. INTERIOR THROW.BOLT LOCK BY'SULUVAN AND ASSOC.' 4-3/4"BALL BEARING HINGES -
LACK.F.MOLP AT 49:-1/2-FROM`BOTTOM ;LOCATED AT 46'FROM BOTTOM 3 PER LEAF FOR LAMINATED CLASS
4 PER LEAF FOR INSUL.._LAM. CLASS I
BOTTOM HINGE AT'•.8-3 8 FROM BOTTOM RAIL
INACTIVE LEAF. "INACTIVE LF�LF /" �L^
CONCEALED FLUSH BOLTS BY'SULLNAN&:ASSOC.' CONCEALED FLUSH BOLTS BY'SULLIVAN &AS50C:.' TOP HINGE AT 11"FROM TOP RAILINTERMEDIATE.HINGES:ECUAL:LY SPACED
1/2'X 2`THROW BOLTS'ENGAGING FRAME AT 1IV X 2 THROW BOLLS,ENGAGING FRAMEAk HINGES FASTENED WITH#12>24'X T/V FN M$ I S ti
HEAD AND SILL :HEAD AND SILL f" R y
MANUALLY OPERATED:LEVERS MOUNTED,DN 'MANUALLY OPERATED LEVERS MOUNTED ON
INSIDE FACE OF LEAF'"STILE LOCATED AT 'INSIDE FACE OF LEAF STILE LOCATED ATE PRODUCT REVISED Lca:E;
7 13 16'THREE PIECE HINGES o '
10-3/4" FROM:TOP.AND BOTTOM 10-3/4" FROM TOP AND BOTTOM as complyingg with the Florida �
LOCK FASTENED TO STILE WITH (2) 38-32 X'1/V FH MS 'LOCK FASTENED-TO STILE WITH.,(2)38-32 X 1/2' FH MS ..3 PER�.LEAF FOR LAMINATED::GLASS Building Codo
-:4 PER LEAF FOR INSUL-LAM:GLASS NoA-No. 19-0326.09
.'✓ BOTTOM HINGE AT B-3/8"FROM BOTTOM'RAIL;
-- -- --- -- TOP HINGE AT 11'FROM TOP RAIL Expiration Date:09/10/2025
i \ �® /' \ :INTERMEDIATE HINGES EQUALLY SPACED By: Iaw I h;;, to a ,; B
Ml o�
I \` I HINGES FASTENED WrTH #10�24 X 1/2`FH MS m v H
aml-Dade Product Control •� o o o a a
0 s
•\ �� 1 I U;`
U-ki
'No.8122
V drawing no.
NOTE LOCKS MUST BE ENGAGED RING I
Sealed:8/24/20
PERIODS OF HURRICANE WARNING. ... ....-.. `?[(CtlFliifi.�����✓, .' sheet-10o/12•
� • a
�iYP.
1.500 f 626 .° o
r ° °
�-
2125 1.750 .T �. 'I I ° $ i''i ` I W. C `a1,
.9_ •—�.�_i ... r o76 TYR /z' I 4-3/4' 0 S I 4,000•—y-i �.¢ YYY777�a
F�.�-2.018-•.� I I �ar C C,
i° II ._.J_._�V a r�i N
(� FRAME 'HEAD/JAMB ; HINGE 'STILE 2�-I :o l- -. I U a.
�i° let
�_-, #12-24 X 1/0 FH Ms 1
' CRS.`TYPE 23
..--- --•--- .078. I' .10-24% 1/2"FH MS
J TYP, r CRS TYPE 23:
Z
. ;t ._ ,.626 i7A t7
I �2
i:966 1.750 3 PIECE..HINGE . BALL.BEARING.HINGE, . �)
4.000
4.668
TYP. i i {-M--4.000.
o•i m
g
m
P._....— �"8 INACTIVE ASTRAGAL STILE
f 5 TOP & BOTTOM:RAIL
. .626,
t,7sa in
f 500" .078: 1 984�.
7YP. j PRODUCT REVISEDf o
(�'�� .. } 1'.2f0 as Bufld7npCondowith the Flarida
—t .094• 9 M. ',a,y 3.r
Ms NGA-No. 19-0326.09 1, m
I 5.3i3-•- - Expiration Date:09110/2025 o n J
1.fiOB'. 122. � JVNxI-".
LOCK ASTRAGAL STILE TMP'
- . _ ._,.... I Mlamt-Dade Product Control ,
SWEEP ADAPTER 3532 3.782 r
2.200—
1.134
LL ...............
,T�T I._.._..Y. 2.257 I -. a �
.062.S .485 135 5 aw.
1YP." _ 11.0to -T _ 2� 4.176 E 2t STIFFENER - - :Z
..—__.� !
-^�1.164�.tb•- .078 I ..�_.58o: II .498
TYR
SILL.COVER
.045 C.
$ r
r^—2.163.
GLAZING..
11 Pi dl 640 I
.0 � 4 1 th . :rsi WEDGEGE
12
SCALE III STILE'
. NG.501 GAiBEAD7/16" GLASS. F ttrtcttElk
88 1.680 ietFrJ r��
p�`• aK
c
e
.. ... �°-498. i
563: . , .��. �. � I,� �_•�.I: 3_ �}.'t. '8f2267� 3-
•� I - - O50 $. .. .
.062 J09
.- eta .. .-.050 .fist .88 •�••
c`
Fes-• ----4.000- 1.313
;iIA �'6�v;
�, ` W10�-•08
{z* FRAME SILL 10 SIDELlTE ADAPTER GLAZING BEAD 5/16,".GLASS GLAZING, BEAD.- INSUL. LAM'..GLASS ` Sealed:8/24/20 ,�`r1 1 t�F sheet t1 of 12'1 .
I
I
;y L
cu
rn
D
ch
\\ ci \..
-'
..—.. :ham ?j �•--- ........ ...� l~3 .
\,
t.
CD
N
f
0
.N \
N
t
co 38+ �tzmm9
CD 0-3 0
( m ��. � a omvca
O ,a O
go
,.
ha
? a data a2-2s: 10 revisrons ALUtAlNUM OUf=$WING>NTRl+NCE DQOR (LM 1.) AL-FAFtogo coRpoRAinoN
o no.a e h' descRotion
"' {. ecae.a g•o t. e:0731+9 ea.PER gem m-virs L66mdor,Bc Fdndoro Corp. EN41NtEERS&Pg40UOTDEkE16PMENT f
F 0103+5 ":.NO CHMUEnas 54EEr dbo-V'&V Windows 936o5UNSE!DRIVESURE=o
N 'a MLAM4 Ft oRIRA 33173 (c.:9.N 9538). !+
P.e3aa.n UPQArt).ra 2orrFeC 2355 West ath Ava. 4
N ar 01.wt No CtMGE nss snet� Fiialeoh,;Fl. 33010: :�' 0020z6a7s ,
1t .(306)4848100 FAX.B,.
N{ °t'k'.,t`Y'. �:cazs o fier REa.REn cCuuENrS. - ,TE{.(305)MS 4151 FAX..(305)HH8=1042 ANL W10 O8W�' f
r