Loading...
HomeMy WebLinkAboutSinglePDF0819-01Interior do Jble 2x4 studs G an* &head match existing trim D/W finished wood spacer '~ / alum door frame \ ni__ t_ VOX Taorl A t2-13 fiberglass fnsulatlon alum. French cedar faced door CDX plywood sfding 1x2 iZ5 cedar trim// Exterior 1/4" x 3" bugle head Tapcon r'ropoeeei voor5 01 o It 11' 1 p 11 e i n Fr rY1I ri Cev tIo Exterior door Jamb NT5 Poor head oinlar original door opening w/ new Siding & doors exfstfng roof structure — Porch cellfng / to remain 1x2 cedar trim GD cefling ;xlsting wood frame reader & walls to rcmaln 1/2" cedar faced plywood slding w/ 1 x 2 cedar battens 0 12" o/c aluminum door frame double 2x4 stud 0 each door Jamb solid 2x4 blockfng 1/4" x 3" bugle -head Tapcon concrete screws 9D 12" o/c (per NOA) Foroh 2x4 etude a 12" o/c 114" x 41/2" hex -head Tapcon ecrewe 0 12" o/c PT 2x4 plate w/ 1/4" x 41/2" hex -head Tapcon concrete screws 6D a" o/c exfstfng floor slab & foundatlon to remain 1/4" x 3" bugle -head Tapcon concrete screws ae shown q I q I1 (thrcehold to elab) NOTE: Wall Siding Shall be 1/2" cedar faced CDX plywood w/ Type 310 stainless Steel 10ci ring -shank nails CD 6" o/c along all framing members Exterior sealant - Bccl siding & 1x2 trim in 51KA "1-A" one -part polyurethane sealant priming of plywood sidire and trim shall be two full coats of KiLZ latex primer. Coat the bottom 8" of trim & plywood siding on edges & rear P1210K to (nstallatior. Additionally, prime face of Siding prior to installation of x2 trim. After trim is instaEled, paint new siding & trim w/ two full coats of exterior latex paint. 1x2 cedar battens &trim Secure 1x2 K5 cedar trim w/ Type 310 stainless steel 8d rirg-shank malls C@ 12 o/c. new 1/2" cedar faced CDX Plywood 5(dfng insulated, (mpact rated aluminum french doors match bottom edge of exfstfng 5idfng exterior patio slab �evtJoh 1/2" = 1' O" �(��✓ ee�e�e F50 Edition 7 - 2020 A5CE 7-16, Kfok Gategory 2 9 Exroeurc 15" - 160 meh drywall cooing to remain exfstfng wood frame door header to remain 2x4 top plate 1/4" x 6" hex -head Tapcon screws 0 a` o/c 2x4 studs 0 12" o/c f2-13 f(berglaes Batt fnsulatlon w/ resin coated Kraft paper moisture res(etant barrfcr 1/2" gypsum drywall solid 2x4 bfocking Ifit erior 30# roofing felt on exterior of studs under the siding PT 2x4 plate w/ 1/4" x 41/2" hex -head Tapcon concrete screws 6D a" o/c wood base to match exfstfng cxfsting concrctc slab & foundatfon to rcmafn NOTE: Door & infill are located in a porch min. 10' away from eaves of roof, L43 File Copy i i N u o u u REVIEWED FOR 43 � n r+ CODE COMPLIANCE. LS %_ L ST. %IE COUNTY OSOCC(zf��z� 43 ,43 � Q S S43 Us L N os� u N � u �0 0L> N �L,LtNN p U 3 U 43 L L Q.u10L 4 �0 PCL,?c [ L L G 61 0'N SL p U !. i uuuus As� S1.gs43uoU I- -1Q U < � o o O ` u � � O IL i °Jc i 4 Q N i I All connectors are products of Simpson -Strong -Tie Mf°g Co., p0 NOT 5UI55TITUTE TYrE OF, NUMS Et2 Index Allow # Ac-tual # Faotcmcr5 IF, emarko� Mark Type Uplift L1 L2 U lift L1 L2 5M/rL TrusSll3eam -min, embed 5" (nto slab - secure w/ 5fmpson "5ET" epoxy X-1 HTT-4 4235 3WO 5/a` Type all -thread rod x 5" * (18) 16ci ring -shank X-2 5P-1 5&5 225 (4) 1Oci (0) 1Od Stud to baseplatc X-3 5P-2 1005 225 (Ei) loci (6) 1Od stud to top plate & header X -4 M 5TA 24 1640 1900 (a) l od (9) loci EPE£.ODDUJOIT IRIEWOERW Product Manuf. Model # AEE?T1]DD.E7= 00DEE OMI11= �T��1�IJbDII Q FL # impact Method of Attachment rulereadeu Product ure Preemure Alum French Doosr v & v windows 5crice 300 Alum. NOA 19-0326,09 Yes #10 x 3" steel screws per door Elevatfon above 26.4 (-) 2al + - 80 "I have reviewed the above components resistance to the wind loads & forces & cladding & have approved their use in the structure. These products provide adcq,uatc specified by current code provisions." John M. Foster -Architect - F(or(da License #8511 l � o � � u W O %J J O loll