Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's ;001 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WATSON RESIDENCE Builder Name: Street: 1305 LONE PINE DRIVE Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL, Permit Number: Owner. MARVIN WATSON Jurisdiction: ST LUCIE COUNTY Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or ebsting New(From Plans) 10. Wall Types(2744.0 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Polystyrene Bead AggrcR=0.0 2529.30 ftz b.Frame-Wood,Adjacent R=11.0 214.67 ft . Number of units,if multiple family 1 c.N/A R= ftZ 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 11.Ceiling Types (3243.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=20.0 3243.00 ftz 6. Conditioned floor area above grade(ftz) 3243 b.N/A R= ftZ Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ 7. Windows(327.8 sqft.) Description Area 12.Ducts R ftZ a.Sup:Attic,Ret:Attic,AH:AHU 1 CLST 6 140 a. U-Factor: Sgl,U=0.65 327.83 ftZ b.Sup: Attic,Ret:Attic,AH:AHU 2 CLST 6 120 SHGC: SHGC=0.25 b. U-Factor: N/A ftZ 13.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 35.2 SEER:16.00 c. U-Factor: N/A ftZ b.Central Unit 18.8 SEER:16.00 SHGC: Area Weighted Average Overhang Depth: 7.954 ft. 14.Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a.Electric Strip Heat 17.0 COP:1.00 b.Electric Strip Heat 7.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ftZ 15.Hot water systems SHGC(AVG): N/A a.Electric Tankless Cap:1 gallons 9. Floor Types (3243.0 sqft.) Insulation Area EF:0.990 a.Slab-On-Grade Edge Insulation R=0.0 3243.00 ftZ b. Conservation features b.N/A R= ftz None c.N/A R= ftZ 16.Credits None Total Proposed Modified Loads: 88.46 lass/Floor Area: 0.101 PASS Total Baseline Loads: 88.73 I hereby certify that the plans and specifications covered by Review of the plans and 0�11JE ST ATF this calculation are in compliance with the Florida Energy specifications covered by this Code calculation indicates compliance ���i„��''' �•�+ with the Florida Energy Code. PREPARED BY: k&;2QijyQBefore construction is completed DATE: 11-22 202H this building will be inspected for compliance with Section 553.908 * Q hereby certify that this building, as des igne , is in compliance Florida Statutes. ith the Florida Energy Cod�o e. COD y� � OWNER/AGENT-- BUILDING OFFICIAL: DATE: /h 2 Z'ZOZf DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifi ss certified factory-sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 an s project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). 11/17/2021 3:21 PM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 8 i FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WATSON RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type. User Conditioned Area: 3243 Lot# Owner Name: MARVIN WATSON Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 1305 LONE PINE DRIV Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City,State,Zip: FORT PIERCE, Family Type: Detached FL, New/Ebsting: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low i BLOCKS Number Name Area Volume 1 AHU 1 2211 20562.3 2 AHU 2 1032 9597.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 GREAT RM 420 3906 No 0 1 Yes Yes Yes 2 LIVING RM 130 1209 No 0 1 Yes Yes Yes 3 FOYER 72 669.6 No 0 1 Yes Yes Yes 4 BEDROOM 2 156 1450.8 No 0 1 1 Yes Yes Yes 5 BEDROOM 3 144 1339.2 No 0 1 1 Yes Yes Yes 6 HALL 96 892.8 No 0 1 No Yes Yes 7 BATH 3 72 669.6 No 0 1 Yes Yes Yes 8 CLST 3 24 223.2 No 0 1 Yes Yes Yes 9 OFFICE 274 2548.2 No 0 1 Yes Yes Yes 10 CLST 2 18 167.4 No 0 1 No Yes Yes 11 OFFICE CLST 30 279 No 0 1 Yes Yes Yes 12 LAUNDRY 68 632.4 No 0 1 Yes Yes Yes 13 KITCHEN 288 2678.4 Yes 0 1 No Yes Yes 14 AHU 1 CLST 9 83.7 No 0 1 No Yes Yes 15 DINING RM 190 1767 No 0 1 Yes Yes Yes 16 NOOK 220 2046 No 0 11 Yes Yes Yes 17 BATH 2 65 604.5 No 0 1 Yes Yes Yes 18 M W IC 2 75 697.5 No 0 1 Yes Yes Yes 19 AHU 2 CLST 9 83.7 No 0 1 No Yes Yes 20 M W IC 3 84 781.2 No 0 1 No Yes Yes 21 M BATH 154 1432.2 No 0 1 Yes Yes Yes 11/17/2021 3:21 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 M W IC 1 112 1041.6 No 0 1 Yes Yes Yes 23 M TOILET 36 334.8 No 0 1 Yes Yes Yes 24 STORAGE 91 846.3 No 0 1 Yes Yes Yes 25 MASTER BEDROO 406 3775.8 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation GREAT RM 21 ft 420 ft2 ---- 1 0 0 2 Slab-On-Grade Edge Insulation LIVING RM lift 130 ft2 ___ 1 0 0 3 Slab-On-Grade Edge Insulation FOYER 8ft 72 ft2 1 0 0 4 Slab-On-Grade Edge Insulation BEDROOM 2 10 ft 156 ft2 __e 1 0 0 5 Slab-On-Grade Edge Insulation BEDROOM 3 10 ft 144 ft2 1 0 0 6 Slab-On-Grade Edge Insulation HALL 1 ft 96 ft2 1 0 0 7 Slab-On-Grade Edge Insulation BATH 3 6ft 72 ft2 __e 1 0 0 8 Slab-On-Grade Edge Insulation CLST 3 2ft 24 ft2 __e 1 0 0 9 Slab-On-Grade Edge Insulation OFFICE 17 ft 274 ft2 ___ 1 0 0 10SIab-On-Grade Edge Insulation CLST 2 1 ft 18 ft2 __e 1 0 0 11Slab-On-Grade Edge Insulation OFFICE CLST 2ft 30 ft2 ___ 1 0 0 12SIab-On-Grade Edge Insulation LAUNDRY 1 ft 68 ft2 1 0 0 13SIab-On-Grade Edge Insulation KITCHEN 1 ft 288 ft2 __e 1 0 0 14SIab-On-Grade Edge Insulation AHU 1 CLST 1 ft 9 ft2 1 0 0 15SIab-On-Grade Edge Insulation DINING RM 12 ft 190 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation NOOK 6ft 220 ft2 1 0 0 17SIab-On-Grade Edge Insulation BATH 2 8ft 65 ft2 1 0 0 18SIab-On-Grade Edge Insulation M W IC 2 12 ft 75 ft2 ___- 1 0 0 19SIab-On-Grade Edge Insulation AHU 2 CLST 1 ft 9 ft2 1 0 0 20SIab-On-Grade Edge Insulation M W IC 3 1 ft 84 ft2 -_-- 1 0 0 21SIab-On-Grade Edge Insulation M BATH 16 ft 154 ft2 1 0 0 22SIab-On-Grade Edge Insulation M W IC 1 7 ft 112 ft2 __e 1 0 0 23SIab-On-Grade Edge Insulation M TOILET 12 ft 36 ft2 ___- 1 0 0 24SIab-On-Grade Edge Insulation STORAGE 16 ft 91 ft2 ____ 1 0 0 11/17/2021 3:21 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 8 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 25SIab-On-Grade Edge Insulation MASTER BEDRO 22 ft 406 ft2 ___ 1 0 0 I ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 3513 ft2 0 ft2 Light N 0.1 No 0.9 No 20 22.62 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 3243 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) GREAT RM 0 Blown 420 ft2 0.1 Wood 2 Under Attic(Unvented) LIVING RM 0 Blown 130 ft2 0.1 Wood 3 Under Attic(Unvented) FOYER 0 Blown 72 ft2 0.1 Wood 4 Under Attic(Unvented) BEDROOM 2 0 Blown 156 ft2 0.1 Wood 5 Under Attic(Unvented) BEDROOM 3 0 Blown 144 ft2 0.1 Wood 6 Under Attic(Unvented) HALL 0 Blown 96 ft2 0.1 Wood 7 Under Attic(Unvented) BATH 3 0 Blown 72 ft2 0.1 Wood 8 Under Attic(Unvented) CLST 3 0 Blown 24 ft2 0.1 Wood 9 Under Attic(Unvented) OFFICE 0 Blown 274 ft2 0.1 Wood 10 Under Attic(Unvented) CLST 2 0 Blown 18 ft2 0.1 Wood 11 Under Attic(Unvented) OFFICE CLST 0 Blown 30 ft2 0.1 Wood 12 Under Attic(Unvented) LAUNDRY 0 Blown 68 ft2 0.1 Wood 13 Under Attic(Unvented) KITCHEN 0 Blown 288 ft2 0.1 Wood 14 Under Attic(Unvented) AHU 1 CLST 0 Blown 9 ft2 0.1 Wood 15 Under Attic(Unvented) DINING RM 0 Blown 190 ft2 0.1 Wood 16 Under Attic(Unvented) NOOK 0 Blown 220 ft2 0.1 Wood 17 Under Attic(Unvented) BATH 2 0 Blown 65 ft2 0.1 Wood 18 Under Attic(Unvented) M W IC 2 0 Blown 75 ft2 0.1 Wood 19 Under Attic(Unvented) AHU 2 CLST 0 Blown 9 ft2 0.1 Wood 20 Under Attic(Unvented) M WIC 3 0 Blown 84 ft2 0.1 Wood 21 Under Attic(Unvented) M BATH 0 Blown 154 ft2 0.1 Wood 22 Under Attic(Unvented) M WIC 1 0 Blown 112 ft2 0.1 Wood 23 Under Attic(Unvented) M TOILET 0 Blown 36 ft2 0.1 Wood 24 Under Attic(U nvented) STORAGE 0 Blown 91 ft2 0.1 Wood 25 Under Attic(Unvented) MASTER BEDRO 0 Blown 406 ft2 0.1 Wood I 11/17/2021 3:21 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 8 I FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS j Adjacent Space Cavity Width Height Sheathing Framing Solar Below 13-1/al,le Ft In Et In Area R-%/Aile Erqrtffinn Ahqnr Grarfp% 1 E Exterior Concrete Block-Polystyr&REAT RM 0 20 0 9 4 186.7 ftZ 0 0 0.1 0 2 S Exterior Concrete Block-PolystyrGREAT RM 0 21 0 9 4 196.0 ftZ 0 0 0.1 0 3 N Exterior Concrete Block-PolystyrddVING RM 0 10 0 9 4 93.3 ftZ 0 0 0.1 0 4 W Exterior Concrete Block-Polystyr&AVING RM 0 4 0 9 4 37.3 ftZ 0 0 0.1 0 5 N Exterior Concrete Block-Polystyren€DYER 0 8 0 9 4 74.7 ftZ 0 0 0.1 0 6 W Exterior Concrete Block-PolystyMI)ROOM 2 0 13 0 9 4 121.3 ftZ 0 0 0.1 0 7 N Garage Frame-Wood BEDROOM 2 11 12 0 9 4 112.0 ftZ 0 0.1 0.1 0 8 W Exterior Concrete Block-Polysty&EOROOM 3 0 12 0 9 4 112.0 ftZ 0 0 0.1 0 9 W Exterior Concrete Block-PolystyrenSATH 3 0 6 0 9 4 56.0 ftZ 0 0 0.1 0 10 W Exterior Concrete Block-PolystyrenCLST 3 0 2 0 9 4 18.7 ftZ 0 0 0.1 0 11 S Exterior Concrete Block-Polystyrer@FFICE 0 14 0 9 4 130.7 ftZ 0 0 0.1 0 i 12 W Exterior Concrete Block-PolystyrerOFFICE 0 19 0 9 4 177.3 ftZ 0 0 0.1 0 _13 N Garage Frame-Wood CLST 2 11 2 0 9 4 18.7 ft2 0 0.1 0.1 0 14 S Exterior Concrete Block-Polysty fflCE CLS 0 2 0 9 4 18.7 ftZ 0 0 0.1 0 15 E Exterior Concrete Block-PolystyrdiAUNDRY 0 1 0 9 4 9.3 ftZ 0 0 0.1 0 16 N Garage Frame-Wood LAUNDRY 11 7 0 9 4 65.3 ftZ 0 0.1 0.1 0 17 W Garage Frame-Wood LAUNDRY 11 2 0 9 4 18.7 ftZ 0 0.1 0.1 0 18 N Exterior Concrete Block-PolystyrEHNING RM 0 11 0 9 4 102.7 ftZ 0 0 0.1 0 19 E Exterior Concrete Block-PolystyrEHNING RM 0 4 0 9 4 37.3 ftZ 0 0 0.1 0 20 S Exterior Concrete Block-Polystyren&OOK 0 6 0 9 4 56.0 ftZ 0 0 0.1 0 21 E Exterior Concrete Block-PolystyrenSATH 2 0 5 0 9 4 46.7 ftZ 0 0 0.1 0 22 W Exterior Concrete Block-PolystyrenSATH 2 0 3 0 9 4 28.0 ftZ 0 0 0.1 0 23 E Exterior Concrete Block-PolystyrerM WIC 2 0 12 0 9 4 112.0 ftZ 0 0 0.1 0 24 N Exterior Concrete Block-PolystyrerM BATH 0 11 0 9 4 102.7 ftZ 0 0 0.1 0 25 E Exterior Concrete Block-Polystyrerfd BATH 0 11 0 9 4 102.7 ftZ 0 0 0.1 0 26 W Exterior Concrete Block-PolystyreM BATH 0 4 0 9 4 37.3 ftZ 0 0 0.1 0 27 S Exterior Concrete Block-PolystyrerM W IC 1 0 7 0 9 4 65.3 ftZ 0 0 0.1 0 28 N Exterior Concrete Block-PolystyrdabTOILET 0 6 0 9 4 56.0 ftZ 0 0 0.1 0 29 W Exterior Concrete Block-Polystyrefold-TOILET 0 6 0 9 4 56.0 ftZ 0 0 0.1 0 _ Z 0 0 0.1 0 30 E Exterior Concrete Block-Polystyr�'�ORAGE 0 7 0 9 4 65.3 ft 31 S Exterior Concrete Block-PolystyrEKORAGE 0 13 0 9 4 121.3 ftZ 0 0 0.1 0 32 W Exterior Concrete Block-PolystyrE&'EORAGE 0 7 0 9 4 65.3 ftZ 0 0 0.1 0 33 N Exterior Concrete Block-Polys~TER BE 0 2 0 9 4 18.7 ftZ 0 0 0.1 0 34 E Exterior Concrete Block-PolystyrUASTER BE 0 18 0 9 4 168.0 ftZ 0 0 0.1 0 35 S Exterior Concrete Block-PolystyTER BE 0 6 0 9 4 56.0 ftZ 0 0 0.1 0 I DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated FOYER None .14 3 8 24 ftZ 2 W Insulated STORAGE None .14 2 8 8 21.3 ftZ I 11/17/2021 3:21 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Single Yes 0.65 0.25 Y 48.0 ft2 22 ft 0 in 1 ft 4 in Drapes/blinds None 2 S 2 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 3 S 2 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 4 N 3 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 10 ft 0 in 1 ft 4 in None None 5 N 5 Metal Low-E Single Yes 0.65 0.25 Y 16.0 ft2 14 ft 0 in 1 ft 4 in None None 6 W 6 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 7 W 8 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None 8 W 9 Metal Low-E Single Yes 0.65 0.25 Y 9.0 ft2 2 ft 0 in 1 ft 4 in None None 9 W 12 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 10 N 18 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 10 ft 0 in 1 ft 4 in None None 11 S 20 Metal Low-E Single Yes 0.65 0.25 Y 16.0 ft2 22 ft 0 in 1 ft 4 in None None 12 E 25 Metal Low-E Single Yes 0.65 0.25 Y 12.0 ft2 2 ft 0 in 1 ft 4 in None None 13 E 34 Metal Low-E Single Yes 0.65 0.25 Y 11.8 ft2 2 ft 0 in 1 ft 4 in None None 14 E 34 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 504 ft2 504 ft2 23 ft 9 ft 11 I INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 i 11 Wholehouse ProposedACH(50) .000295 2513.3 137.89 258.87 .0958 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Black Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COP:1 17 kBtu/hr 2 sys#2 I COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER:16 35.2 kBtu/hr 1056 cfm 0.8 1 sys#1 2 Central Unit/ Split Single SEER:16 18.8 kBtu/hr 564 cfm 0.8 2 sys#2 I HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Exterior 0.99 1 gal 55.1 gal 120 deg None I 11/17/2021 3:21 PM Ener Gau e® - gy g USA 7.0.00 FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 6 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 I DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 140 ft2 Attic 14 ftz Default Leakage AHU 1 CLS (Default)c(Default)c 1 1 2 Attic 6 120 ft' Attic 12 ft2 Default Leakage AHU 2 CLS (Default)c(Default)c 2 2 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ]Jan Feb Mar Apr [ ]May Jun Jul [X]Auge [ ]Oct [ ]Nov Dec Heatin [X]Jan Feb Mar f Apr [ ]May 4 Jun Jul [ ]Au4 SeP [ ]Oct [X]Nov Dec Vent in [ ]Jan Feb Mar [X]Apr [ ]May [ Jun Jul [ ]Aug [ Se [X]Oct [X]Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 GREAT RM Default(8lbs/sq.ft. ft2 ft 0.3 LIVING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 OFFICE Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 OFFICE CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8lbs/sq.ft. ft2 ft 0.3 AHU 1 CLST Default(81bs/sq.ft. ft2 ft 0.3 DINING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 NOOK Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU 2 CLST 11/17/2021 3:21 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 7 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 STORAGE Default(8 Ibs/s .ft. ft2 ft 0.3 MASTER BEDROO 11/17/2021 3:21 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 8 of 8 I I ' ' 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WATSON RESIDENCE Builder Name: Street: 1305 LONE PINE DRIVE Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL, Permit Number: Y U Owner: MARVIN WATSON Jurisdiction: ST LUCIE COUNTY W 2 Design Location: FL,Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation,insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and Wring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or ceiling Concealed When required to be sealed,concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer.Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilin s. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 11/17/2021 3:21 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD i ESTIMATED ENERGY PERFORMANCE INDEX` = 100 The lower the EnergyPerformance Index, the more efficient the home. 1305 LONE PINE DRIVE, FORT PIERCE, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Polystyrene Bead AggrER=0.0 2529.30 ft2 I b.Frame-Wood,Adjacent R=11.0 214.67 ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 1 11.Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=20.0 3243.00 ft2 6. Conditioned floor area(ft2) 3243 b.N/A R= ft2 2 7. W ftindows- Description Area c.N/A R= 2 a. U-Factor: S I,U=0.65 327.83 ft2 12.Ducts,location&insulation level R ft g a.Sup:Attic,Ret:Attic,AH:AHU 1 CLST 6 140 SHGC: SHGC=0.25 b.Sup: Attic,Ret:Attic,AH:AHU 2 CLST 6 120 b. U-Factor: N/A ft2 SHGC: 13.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 35.2 SEER:16.00 SHGC: b.Central Unit 18.8 SEER:16.00 d. U-Factor: N/A ft2 14.Heating systems kBtu/hr Efficiency SHGC: a.Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 7.954 ft. b.Electric Strip Heat 17.0 COP:1.00 Area Weighted Average SHGC: 0.250 8. Skylights Description Area 15.Hot water systems a.Electric Cap:1 gallons a. U-Factor(AVG): N/A ft2EF:0.99 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 3243.00 ft2 Credits(Performance method) None b.N/A R= ft2 c.N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building o&zgE sT.grF Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant fe tures. Builder Signature: AWAS Date: I��22-Ztf�/ �*✓ K`I �. Address of New Home: JDjOs Lane �,1Q `�,�-��L, City/FL Zip: rr(?m,•Y- pc 3�rg,,s 'co D wig *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/17/2021 3:21 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1