Loading...
HomeMy WebLinkAboutbuilding planPlumbing Plan Legend Pool Returns 1.51D .. - Skimmersg 2" Vac line O 2" Spa MD o 2.5" Jets 2" JO •--------- Return 1.51 Specifications 2.5" r--------------------------------------------------------------------- , I 1.5" .—..—.._.._. 2d 2" ; 21 , -'r _ �211 i 2.5" n 1.5 �e F ! 1, I i I 2 I ' I , 1 I , I � I I 2.5" BI 0 Va /line 2,r _ .. _ .. � B• 21r . .J fi _ _ _ _ _ _ Pool Dimensions: 17' x 34' Area: 578 Sq Ft Perimeter:102' LN Pool returns: 3 Vac Stub Out: Yes with Approved Vac Lock Pool Capacity: 18,374.62 gallons Light: (2) 10 watt Savi Melody Skimmer: 2 Interior coating: Game coat. Safety ( Child Barrier) Decking: New 1179 Sq Ft of Concrete. Footer 8"x8" W#5R Pump: Pentair Variable Speed @ 30.623 GPM Turnover Rate: 10 HR Chlorinator: Salt generator Filter: Pentair 200 sq ft cartridge Clean and Clear Spa 8'x8' FT +12" rise. with 6 hydro jets, 2 returns. 1 HP Blower. 4811 spell way. #3 Rebar I 1e 12" O.C. w" Separate Circuit for motor and light GFI Breakerlor pump WP GFI 10'-2i from water Swim In Bench Detail N.T.S. WP Manual Starter swdcft1yp) Time Clock F Pump Motor #6 Solid copper bol wire w/ Appn. Clamps(one one as side of Pop-4 lots S.P.S.T ♦ Junction Box Toggle �Er f Si MldPool gSwkchLi M Ground all Metal boxe&(light,motor,ech.(Savi Melody light nitch requires no ground) With #8 wire (solid) Light fixtures do not require ground fault Interrupter Electric Diagram N.T.S. p (1) #8 Bare copper wire bonded to pool steel as shown EOUOPOTENTIAL BONDING DETAIL Per FL Sulk. Code Adaptation of N.E.C. 200e sec680.26 Pump & Filter to be screwed down with 1.5 " long 1/8 or larger approved concrete anchors. Filter 2500 PSI concrete en 2 hard coil T Nails 099 O 0,1'h EMS <" + Existing Wall C o Bu 216D hats (all Material) TYP 12 (1) # 5 rebar Ale or (2) #3 > I Undisturbed soil underneath Existing Slab step rebar footer 2•x4• 10" 04 Edge continuous 5' Tile I Y ` Plywood Footer Detail N.T.S. 6Mil Polly Moisture Barrier Steps N.T.S. III I Compacted fill Wall Section Cantilever N.T.S Pump & Filter Tie Down N.T.S Outside of f rexise,51ft andfanner- 4"thck /#a REBAR 0 12" O/C each way $ FT to 6 FT- 6" Thkk w/#3 Rebere6" 0/C each way 0 FT to 3 PRB" Thick w/#3 Rebar® 6" 0/0 each way 9' 5' s Angle Of i Repose N.T.S. J " 'Excavation of angle of repose Is allowed providing 1. Shoring is Installed on excavatetl surfaces sufficient to secure soil from erosion or settlement. 2.No Undermining occursof undermining occurs consult a design professional. 3.Compadkn test of the backfllled material are provided at C.O. of the pod. Water line 4 inch min to lens Shoring Detail N.T.S. 1" sch 40 pv No J-Box Needed 1.6 sch 40 PVC 14 inch min 1.5" conduit No Bonding needed Light Detail SAVI MELODY N.T.S. 12 volt transformer 32" a All J C Leaf Trip Cover 25"SPx2"SOCx2 2.51 Water 36 " Spa/ Pool Drain N.T.S. 18° 6. � 0' 1.5 2" PVC/ i Flex Bench 1 Pipe I Cross e�� 7B" # 3 12" O.O./ section Bw 1" Mln cement & stee coverage / \ Channel Drain Ant s" Min 6-10" Entrapment Tnkknesa Min Thick Iloor PVC Piping In Gunnite Spa X Section N.T.S. Water Level Concrete or Paver deck 2" or 1.5" PVC sch. �0 Pump Suction Side Skimmer Detail N.T.S. From Beam Total pool Length Typical section through POOL N.T.S. NOTES: 4 1) PLANS AND ENGINEERING IN ACCORDANCE WITH THE FLORIDA BUILDING CObk, RESIDENTIAL 2020, ANWAPSP/1(Y R• ANSI/APCP/frr A• Alvcl/AdSP/ICC 5; ticj,� ANSI/APSP/ICC 6; AND ANSI/APSP/ICC 7. 2) ALL CONSTRUCTION AND INSTALLATIONS TO COMPLY WITH THE FLORIDA BUILDING' ` CODE RESIDENTIAL 2020, ANSI/APSP/ICC3: ANSI/APSP/ICC 4; ANSI/APSP/ICC 5: \ ANSI/APSPACC 6: AND ANSI/APSP/ICC 7. ` 3) GUNITE / SHORECRETE TO BE 3000 PSI MINIMUM AT 28 DAY. \ 4) ALL STEEL SHALL BE GRADE 40 MINIMUM. 5) ALL PIPING SHALL BE SCH 40 OR,SCH 80 PVC, AND INSTALLATIONS SHALL COMPLY WITH FBC PLUMBING 2020. 6) ALL POOL AND SPA SHALL HAVE CONTINUOUS SOIL BEARING ON CLEAN COMPACTED SOIL WITH 2O00 PSF MINIMUM. 7) ALL HANDRAILS, LADDERS, LIGHTS SHALL BE BONDED WITH #8 GROUND WIRE PER NEC 680. 8) POOL AND SPA SHALL BE PROVIDED WITH APPROVED CHILD BARRIER OR SCREEN ENCLOSURE, HOUSE SAFTEY BARRIER OR ALARM SYSTEM ALL IN ACCORDANCE WITH FRCR 4Sm.17.1. 9) ALL GAS AND FUEL PIPING SHALL BE PER FBC FUEL AND GAS 2020 (SEPARATE CONTRACTOR). 10) ALL ELECTRICAL INSTALLATIONS SHALL BE IN ACCORDANCE WITH NEC 2017 EDITION: 11) POOL AND SPA EQUIPMENT SHALL BE SECURED TO CONCRETE PAD. 2,1 ✓c>Z is12) AFTER COMPLETION OF POOL CONSTRUCTION, HOMEOWNER SHALL CONSULT O LISCENSED POOL CONTRACTOR IN ORDER TO DRAIN POOL IF SO DESIRED. REVIEWED FOR 13) HEATING EQIUPMENT SHALL COMPLY WITH FBC R 4501.14 CODE COMPLIANCE ST. LUCIE COUNTY Pools By Vitali,INC Do not duplicate - This drawing is the property of (Family Pools Inc) and may be purchased separately for PAGE DEPT $250. No duplication allowed. Violators may be prosecuted. Scale: 1• = 10' Mark Squadrito i1 7466 Legends DR. Port St Lucie. FL. 34986 Pools By Vitali,INC. State Lic.# CPC 1458526 DESIGNER REV Vitali Bederak SHEET 1 OF 1 PAUL WELCH INC. MECHANICAL * ELECTRICAL * CIVIL ENGINEERING 1984 S.W. BILTMORE ST. SUITE# 114 PORT SAINT LUCIE, FL 34984 PHONE EMAIL (772) 785 - 9888 PWELCHINC@AOL.COM PAUL WELCH P.E. FL. REG. No. 29945 SEP 0 4 2021 \\v11111II IIIII,/,// * No. 29945 0'•. STATE OF 0, .F/OR1QP:�ty, F ''',,50/ONAii-1�;,,. , M. / AREA CALCULATIONS: / LOT CONTAINS: 59,168 SF = 100% / LOWER LEVEL, GARAGE, PATIO, AND ENTRY = 3,770 SF = 6.4% PAVER DRIVEWAY AND CONCRETE SLAB = 3,165 SF = 5.3% / POOL AND DECK = 1,735 SF = 2.9% OPEN SPACE = 50,498 = 85.3% e / MIN. SETBACK REQ. FRONT SIDES ,� S CNR SIDES REAR ZNG. TECH.-f CZ✓ h0 tih' M �a °ao'9 LOT 3 (OccUp t IRgNs FFF, Z653) 2g29 ON cs LOT 2 Nvp (Vgcq NOIpJe"IR ?Q Nr) N0.14' 6025 ' a �•� 2>1 �Qtgl 25.41 27 S >3°$p, 14' F / ^ kKf* 63,e OB 20. A 25.3 // l„ CS ��SB 'Vbgb E 2 21g ao, / bb' TPgNS 5.40 RI4149__ 2631 26 9�ONCS 2b� `b2 25.50 265* �Zgg G / 25A3 �Nker V / 0 Z64ti 7147'y644 fMENT 262 I FC .65 ¢ $ PNO 25. I 26.0 ■ �O / / y63 /' / N� NO Io/g" IQ >q gigs R� 26.6)9 / �.' \ \ NAt / > 34" IN l I 4 6 s6,4g, l 26.6 � Zg:f9 u cpf6g \ �59 5.51 i / LU O '0 26.0x / 26.4 J 54.3 8 ?s C• s'IO.p,so" 24.71, / / 8.6>, W / 26.4x / 11.08, / M �5g.3g 25.Bx 2>n y 26.1 x 25.66 aj2gi g26 bb* ` l l 27.Ox 27.2x 1�i 0. Z5 CO Sb�3� / gbh No X0 q„-rp 25.90 S 89059'49" E 87 21' _ 2 .68 27.2x / /� O \ h / 7 26./3 UNPLATTED /.gGOLF COURSE/526.�27.2x + / LOT 1 • / / 26.3 pROp05E0 g vfR 27.2x 26. a0t �Ay) `D \ cF 25.9 / \ pROp 26.6>, J 2Z0 / 25. X `\ 'SI q SEp ` y / / 25.8 \ tF Fps-- r"z R oEn ^20 UNPLATTED CONSERVATION `\ 8 zp, / / �, ,��`r� EASEMENT WETLAND NO. 61 \ O.R.B. 1431, PAGE 1158 \ \ h cOVp NO 26. pROp 9.25' ,y y / 25.8 01b \ \ OSFpPOOL c % /// yaati ABBREVIATIONS LEGEND `\ LINE CHART Ll 5 35°26'59" E 10.49' NON RADIAL >.0 po A/C AIR CONDITIONING EOW EDGE OF WATER MAD METES AND BOUNDS SF SQUARE FEET ° „ , /2.83' ry / AC ACRE EP EDGE OF PAVEMENT N6D NAIL AND DISK SHP SHIP SPIKE OR BOLT L2 5 35 26 59 E 21.99 NON RADIAL AL ALUMINUM ESS ELECTRIC SERVICE BOX N NAIL SLCR ST LUCIE COUNTY RECORDS \ / ANC ANCHOR ESMT EASEMENT NA NON -APPLICABLE SLP STREET LIGHT SUPPORT POLE \ ") pp / / AP ANCHOR POLE EX. EXISTING NAVD NORTH AMERICAN VERTICAL DATUM S.S. SANITARY SEWER CURVE CHART 54.33' pg �OSFp 2%0 APRX APPROXIMATE EXT EXTENDED NGVD NATIONAL GEODETIC VERTICAL DATUM SPC STATE PLANE COORDINATES \ �R ASP ASPHALT FNC FENCE NO NUMBER ST SEPTIC TANK Cl BE BUFFER EASEMENT FC F" CURB NTS NOT TO SCALE STD STANDARD \ 26.8x Eby / BFP BACK FLOW PREVENTOR FOC FIRE DEPARTMENT CONNECTION CIA OVERALL STU STORY \ R= 110.00' (P) / BLKG BUILDING LO K FFE R FLOFINISHED FLOOR ELEVATA EAST ION AD OE OVERHEAD EASEMENT SWL SWALFSET 5V EARYVALVE \ A= 67°33'31" 2!2 / BM BENCHMARK FH FIRE HYDRANT OHE OVERHEAD ELECTRIC TA TOP OF ASPHALT L= 129.70' 6 BOC BACK OF CURB FND FOUND CHU OVERHEAD UTILITY TM TAX MAP BP BRICK PAVERS FOC FACE OF CURB OR OFFICIAL RECORD TMH TELEPHONE MANHOLE R= 110.00, (M) h' BOW BACK OF WALK FOW FACE OF WALK O.R.B. OFFICIAL RECORD BOOK TOO TOP OF BANK BAG BEARING FPL FLORIDA POWER 6 LIGHT P/C PROPERTY CORNER TOE TOE OF SLOPE A= 67° 35' 22" 25.9 / h . BW BARBED WIRE GA GREEN AREA P/L PROPERTY LINE TP TRAVERSE POINT , C66 CURB AND GUTTER GMH GAS MANHOLE P PLAT TR TELEPHONE RISER L= 129.76 CdT CULPEPPER6 TERPENING GNO GROUND PAVE PAVEMENT TRANS TRANSFORMER C2 C, C/0 CUT OUT GRD GRINDER PB PLAT BOOK TSB TRAFFIC SIGNAL BOX LEGAL DESCRIPTION: LOT 1, POD 22, P.U.D. II AT THE RESERVE, ACCORDING TO THE PLAT THEREOF, RECORDED IN PLAT BOOK 47, PAGE(S)18, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. 26.2 x x 7.5 27.2 x 3 H 6903� ,qSr ThF F � 162 6S,(A�) NC �V SAT NFRF (Oc OT 1 S4�F FFF �� F�) .04 ADDRESS: 7466 LEGENDS DRIVE PORT ST. LUCIE, FL. 34986 NOTES: SUBJECT TO ANY APPLICABLE EASEMENTS, RIGHTS -OF -WAY, OR OTHER RESTRICTIONS OF RECORD. A SEARCH OF THE PUBLIC RECORDS HAS NOT BEEN MADE BY THIS OFFICE. ELEVATIONS ARE IN FEET AND REFERENCED TO A SURVEY PERFORMED BY VELCON GROUP, INC. DATED 05/08/2013, JOB# 13-026. THE DATUM OF SAID SURVEY IS THE NORTH AMERICAN VERTICAL DATUM OF 1988. (NAVD 1988). BEARINGS SHOWN HEREON ARE BASED UPON AN PLATTED MERIDIAN, ALONG THE SOUTHERLY PROPERTY LINE OF LOT 1, HAVING AN PLATTED BEARING OF N 69°37'09" W. ALL OTHER BEARINGS ARE RELATIVE THERETO. PROPERTY LIES IN F.I.R.M. ZONE "X", AS SHOWN ON MAP NUMBER 12111CO260J, DATED 2/16/20. FLOOD ZONES ARE APPROXIMATE AS SCALED FROM FLOOD INSURANCE RATE MAPS. IN ACCORDANCE WITH CHAPTER 5J-17.051, ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY, IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY. UTILITIES SHOWN HEREON ARE VISIBLE ABOVE GROUND FEATURES. ADDITIONAL SUBSURFACE UTILITIES AND OR FEATURES MAY EXIST. THERE MAY BE ADDITIONAL RESTRICTIONS THAT ARE NOT SHOWN ON THIS SURVEY, THAT MAY BE FOUND IN THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. NOT VALID WITHOUT THE ORIGINAL SIGNATURE AND RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. LEGAL DESCRIPTION PER SPECIAL WARRANTY DEED RECORDED IN OFFICIAL RECORD BOOK 2330, PAGE 1752, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY. THE EXPECTED USE OF THE SURVEY AND MAP IS RESIDENTIAL. ALL DISTANCES AND ELEVATIONS SHOWN ARE IN ACCORD WITH THE UNITED STATES STANDARD USING FEET. ALL DIRECTIONAL MEASUREMENTS SHOWN ARE IN THE FORMAT OF DEGREES, MINUTES AND SECONDS. LOT CONTAINS: 59,168 SQUARE FEET. BOUNDARY AND TOPOGRAPHIC SURVEY FIELD DATE: 11-24-20. FORMBOARO SURVEY FIELD DATE: 02-15-21. CERTIFIED TO: MKS CONSTRUCTION, LLC. C. A (� \Q 25.4 p} p. } h' \ ✓ ✓ 0a \ ° \ O's 25.50 OL�j \ RT \ 'O C 4' '4 N N \ m W \ r \ \ 25.6x C CATV CB CBS CHO Cr CL CLF CM CMP CO COR COW CONST COV CE COVP CPP CPPIPE CS 4 O/F D DC D.E. CALCULATED CABLE TELEVISION BOX CATCH BASIN CHORDETE BLOCK STRUCTURE CURB INLET CENTERLINE CHAIN LINK FENCE CONCRETE MONUMENT CORRUGATED METAL PIPE CLEAN OUT CORNER NSRU CONSTRUCTION COVERED COVERED ENTRY COVERED PORCH CONCRETE POWER POLE CORRUGATED PLASTIC PIPE CONCRETE SLAB DELTA ANGLE DRAIN FIELD DEED INFORMATION D" CURB DRAINAGE EASEMENT DROP INLET HC HCP HOPE HW HYD ICV ID ILL 1:NT INV IP S IR IRR N ICV IW L LB LFST LME LOC LP LS M HEADER CURB HANOI-CAP HIGH DENSITY POLYETHYLENE WIRE HEADWALL HYDRANT IRRIGATION CONTROL VALVE IDENTIFICATION ILLEGIBLE INTERSECTION INVERT IRON PIPE IRON PIPE 6 PLUG IRON ROD IRRIGATION RRIGATION VALVE RRIGATION CONTROL VALVE IRRIGATION WELL LENGTH LICENSED BUSINESS LIFT STATION LAKE MAINTENANCE EASEMENT LOCATION LIGHT POLE LICENSED SURVEYOR MEASURED PC PCC PCO PCP P D.E. PG PI PRKG PK6D PK/TT PLS POD PPCOPMMENCEMENT PRC PRO PROP PRM PSM PSWL PT P.U.E. PVC R&C R/W R POINT OF CURVATURE POINT OF COMPOUND CURVATURE PRESSURE CLEAN OUT (SANITARY) PRIVATE DRAINAGE EASEEMENT PAGE POINT OF INTERSECTION PARKING PARKER KALON NAIL AND DISK PARKER KALON NAIL AND TIN TAB PROFESSIONAL LAND SURVEYOR POINT OF BEGINNING PER OF POINT OF REVERSE CURVATURE PRORATED DISTANCE PROPOSED PERMANENT REFERENCE MONUMENT PROFESSIONAL SURVEYOR 6 MAPPER PLASTIC SWALE POINT OF TANGENCY PRIVATE UTILITY EASEMENT POLYVINYL CHLORIDE ROD AND CAP RiGHT-OF-WAY RADIUS TT TWP TYP U/C U.E. UP UR UW VC VLT WO WL WM PWEL WPP WS WV 6 TIN TAB TOWNSHIP TYPICAL UTPOINT ILITY EASEMENT ON UTILITY POLE UTILITY RISER UNDER WATER VALLEY CURB VAULT WOOD WATER LINE WATER POINT WOOD POWER POLE WATER SERVICE WATER VALVE OAK TREE PINE TREE PALM TREE R= 110.00' (P) A= 56'44146" L= 108.94' R= 110.00' M ( ) A= 56°50,5r, L= 109.14' C3 R= 330.00' (P") A= 5°12'5T' L= 30.04' C4 R= 330.00' (P") A= 14° 38' 3r' - L= $4.34, \ \ 25 411, pA'p C. 6 NO rb DIA DIP DMH DUE E ECP EL ELEC ELEV EM ENC DIAMETER MAX DUCTILE IRON PIPE MB DRAINAGE MANHOLE MEAS DRAINAGE 6 UTILITY EASEMENT MES EE OF CONCRETE MH ELLEECTRICALL CONTROL PANEL MHWL ELEVATION MIN ELECTRIC MN ELEVATION MN6D ELECTRIC METER MIT ENCROACHMENT MW MAXIMUM MAIL BOX MEASURED MITERED END SECTION MAN HOLE MEAN HIGH WATER LINE MINIMUM MAGNETIC NAIL MAGNETIC NAIL 6DISK MITERED END MONITORING WELL RCP RFL RE RLS RP RR RRS S/W SMH SOT SEC REINFORCED CONCRETE PIPE ROOF LINE RANGE REGISTERED LAND SURVEYOR RADIUS PO RAILROAD TNT RAILROAD SPIKE SIDEWALK SANITARY SEWER MANHOLE SOUTHERN BELL TELEPHONE SECTION EM ®B YRa 27.0 ELECTRIC METER ELECTRIC SERVICE BOX YARD DRAIN PROPOSED ELEVATION \ \ \ \ \ \ ROBERT F. KEMERSON PROFESSIONAL SURVEYOR AND MAPPER STATE OF FLORIDA (PSM) #6285 o ZN DC J � � W�z� M W •zoo z J o .3 u O 0> v ^ Z CUD 00 us r W>>c LUd CL LL d z U) Z�°z CL N <� ° 3 .J wr > U z O 0 V C7 440 >6 W N V% H CL Q (L aW � of OWZ > V iy10 N Q Y Z 0 m N wri G DRAWN BY: BK _ APPROVED BY: R. KEMERSON SCALE: 1 20 DATE• 1_2/_02/20 FIELD BOOK/PAGES SURVEY MAP JOB NUMBER: 20-2128 SHEET: 1 OF i N:\Projects\2020\20-2128 MKS Legends Dr\20-2128 BNDY CAD 2020.dwg, 9/27/2021 10;37;48 AM, Canon iPF670