Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's i Contractor FORM R405-2017 �/ FLORIDA ENERGY EFFICIENCY COD�oF�(�R BUILDING CONSTRUCTION Florida Department of Business'and Professional Regulation - Residential Performance Method Plroject Name: Lot 126 Block 5 Waterstone 1820 BGL Builder Name: ADAMS HOMES Street: 5343 Vespera Street Permit Office: City,State,Zip: Fort Pierce,FL,34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL,ST_LUCIE_CO_INTL County: St.Lucie(Florida Climate Zone 2) I 1. New construction or existing New(From Plans) 9. Wall Types(2120.0 sqft.) Insulation Area I 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1850.00 ft2 b.Frame-Wood,Adjacent R=13.0 270.00 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1820.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1820.00 ft2 6. ;Conditioned floor area above grade(ft2) 1820 b.N/A R= ft2 iConditioned floor area below grade(ft2) 0 c. N/A R= ft2 11.Ducts R ft2 7. Windows(239.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 364 a. U-Factor: Dbl,U=0.33 168.74 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.33 32.38 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a.Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl,U=0.33 20.42 ft2 SHGC: SHGC=0.31 13.Heating systems kBtu/hr Efficiency d. U-Factor: other(see details) 17.78 ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: other(see details) Area Weighted Average Overhang Depth: 4.143 ft. Area Weighted Average SHGC: 0.269 14.Hot water systems 8. Floor Types (1820.0 sqft.) Insulation Area a. Electric Cap:40 gallons EF:0.940 a.Slab-On-Grade Edge Insulation R=0.0 1820.00 ft2 b. Conservation features b.N/A R= ft2 None c. N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.131 Total Proposed Modified Loads: 64.41 Total Baseline Loads: 68.84 PASS I hereby certify that the plans and specifications covered by Review of the plans and S74?' this calculation are in complian he Florida En specifications covered by this Code. O _ �, O calculation indicates compliance � �,,,r o 1.0 with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: os-18-g0go Winn KPomany this building will be inspected for O -`-? IjY - y compliance with Section 553.908 * w I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida:MCode CIO OWNER/AGE �"� BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). i 3/18/2020 12:42 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 1 , FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Lot 126 Block 5 Waterstone 1 Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 1820 Lot# 126 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone #Iof Units: 1 Worst Case: No PlatBook: Blwlder Name: ADAMS HOMES Rotate Angle: 0 Street: 5343 Vespera Street PIermit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City,State,Zip: Fort Pierce, Famil Type: Single-family i Y YP 9 Y FL 34951 New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp 1/ Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium I BLOCKS Number Name Area Volume 1 Block1 1820 18200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 33 ft 0 1820 ft2 ---- 0.42 0 0.58 I ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium N 0.85 N 0.85 No 0 26.6 I / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1820 ft2 N N I I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1820 ft2 0.11 Wood I I I I3/18/2020 12:42 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 4 f I o FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS ornt Adjacent Space Cavity Width Height Sheathing Framing Solar Below To Wall Type0 ! 1 N Exterior Concrete Block-Int Insul Main 4.1 59 0 10 0 590.0 ft2 0 0 0.6 0 2 W Exterior Concrete Block-Int Insul Main 4.1 20 0 10 0 200.0 ft2 0 0 0.6 0 3 S Exterior Concrete Block-Int Insul Main 4.1 66 0 10 0 660.0 ft2 0 0 0.6 0 4 E Exterior Concrete Block-Int Insul Main 4.1 40 0 10 0 400.0 ft2 0 0.6 0 5 - Garage Frame-Wood Main 13 27 0 10 0 270.0 ft2 0 0.23 0.01 0 I DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 I WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in 0 ft 10 in None None I 2 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in None None 3 W 2 Vinyl Low-E Double Yes 0.33 0.31 N 7.1 ft2 9 ft 0 in 0 ft 6 in None None 4 W 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 0 in 0 ft 10 in None None 5 W 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 0 in 0 ft 10 in None None 6 W 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 9 ft 0 in 2 ft 0 in None None 7 S 3 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in None None 8 E 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 11 ft 10 in 0 ft 6 in None None 9 E 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in None None 10 E 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 11 ft 10 in 0 ft 6 in None None I GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 396 ft2 396 ft2 64 ft 8 ft 1 I INFILTRATION # I Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 2123.3 116.57 219.22 .1685 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 I i 3/18/2020 12:42 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 4 f FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 35 kBtu/hr 1167 cfm 0.75 1 sys#1 I HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None I SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftZ I DUCTS ----Supply--- --Return--- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 364 ftZ Main 91 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar Apr Ma ri Jun X Jul X Au X Se Oct Nov Dec Heating Jan Feb Mar f Apr f May Jun f Jul f Au f SeP Oct NDeVentin Jan Feb Mar [X]A r [ Ma Jun [ Jul [ Aug [ Se [X]Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Sc i edule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftZ 0 ft 0.3 Main i I 3/18/2020 12:42 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 4 �2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location &insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Main 3. No.of units (if multiple-family) 3. 1 4. Number of bedrooms 4. 4 13.Cooling system: Capacity 35.0 a)Split system SEER 15.5 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 1820 d) Room unit/PTAC EER e) Other 7.Windows,type and area a) U-f actor:(weighted average) 7a. 0.346 b) Solar Heat Gain Coefficient(SHGC) 7b. 0.269 14. Heating system: Capacity 34.6 c)Area 7c. 239.3 a)Split system heat pump HSPF 8.5 b)Single package heat pump HSPF 8.Skylights c) Electric resistance COP a) U-f actor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient(SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab-on-grade (R-value) 9a. 0.0 b)Wood, raised (R-value) 9b. 15.Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10.Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g) Other 1'.Wood frame (Insulation R-value) 10131. 13.0 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b, c)Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Sign Date: i Address of New Home: 5343 Vespers Street City/FL Zip: Fort Pierce, FL 34951 I 3/18/2020 12:42:42 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1