Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Residential PV Roof Mount Installation
-SE7600H-US Inverter -COGEN Disconnect Utility Meter Located adjacent to Utility meter F 71 rill - do � R O N Inverter Type: SolarEdge SE760OH-US ° PV Panel: (26)Silfab-SIL 360 NX T Racking: Iron Ridge XR-100 Total Wattage: 9,360W Roof Type: Composition Shingles Wind Load: 27 to 45 Deg O ° Fastener Type: Use 5/16"Dia 4"Lags # # Modules (6) Sheet Index Pitch: 30° S-1 Cover Sheet/Site Plan S-2 Detail Azimuth: 92° E-1 One-Line E-2 Electrical Code S-lA Mounting Plan H General Notes: -SolarEdge SE760OH-US Inverter O located near utility meter -SolarEdge P401 Optimizers T T El located on roof behind each module. U -First responder access maintained and from adjacent roof. 31-I -Wire run from array to connection is 60 feet. R-1 61_011 E # Modules (20) Oak Pitch: 30° Layout Subject to Change Based on Site Conditions AC/DC Solar LLC Azimuth: 182° 605 W Lumsden Rd, Donnie C Godwin Engineering and D GOOD., g g Godwin `.`p:.�,G ENSF.•/2�.��� Desi n LLC No 81360 '• Brandon FL 33511 g , 8378 Foxtail Loop 202 2.2 STATE OF 855-577-7999 :•� System meets the requirements of NFPA 70th Edition, Chapter 11.12 Install will be done to Manufacturer Spec Pensacola, FL 32526 8 ONA�E?�`�,,, Legend 1 Meets All Editions of Florida Fire Prevention Code 2020 7th Edition Customer Info: D. Chad Godwin, PE I,aE,,,,,,,,. First responder access Meets all requirements of NFPA-1 7th Edition and NFPA-101 Chad@godwineng.com 1 2:22:54^°PaM °PEs°Fri°Tor Ground Access Chimney 3' Access Pat wa �E E.�• oa� '00'06- Utility Meter Satellite Represents all Fire Clearance 1st Responder Access Matthew Lewis 0o y 0 Vent Pipe p Date: 12/27/2021 o minimum of 36" unobstructed as per ma PV Disconnect SolarEdge Inverter including Alternative methods p 8212 Amalfi Cir D b ZU NSection R324 of the 2018 IRC rawn Y� Meets the requirements of the following- (2020 FL Residential Code & FBC, 7th Edition (2018 International Fort Pierce, FL Revised by: Rev 00 Residential Code) - 2nd Printing modified by the FL Building Standards, 2020 Florida Building Energy 34951 Conservation Code 7th edition, County of St. Lucie Code, 2017 National Electric Code.) Rev Date: Page: S-1 Compass for Aerial Solar Module 7f6— G x Jfa HEX HERO 6-OLT 3/8-16 FLANGE "UT ��� 3—5/8 11 Ironridge XR-100 Install will be done to Manufacturer Spec General Notes: - Flashlocs are secured to roof rafters. Donnie C Godwin Engineering and Godwin @ 48" O.C. in Zone 1, @ 48" O.0 in Zone 2e, Design, LLC :,: N. 8,360 ..,=_ @ 24" O.C. in Zone 2r, @ 24" O.0 in Zone 3 2021 .12. 8378 Foxtail Loop STATE OF Pensacola FL 32526 using 5/16" x 4" stainless steel Lag bolts. 28 ,... D. Chad Godwin, PE S"" ' - Subject roof has One layer. Chad@godwineng.com 12:23:08 No µTELECTRON1CLOP1E5 - All penetrations are sealed and flashed. '00'06- Roof Section Pitch Roof Rafter and Spacing Overhang Notes: R 1-R2 7/12 2"x4" @ 24 O.C. 1211 Truss AC/DC Solar LLC -Roof Height 15' Customer Info: 605 W Lumsden Rd, g Inverter Type: SolarEdge SE760OH-US Brandon, FL 33511 -Per 2020 FBC, the Roof Mounted PV System PV Panel: (26) Silfab-SIL 360 NX 855-577-7999 will be subject to the following design criteria: Racking: Iron Ridge XR-100 Matthew Lewis Date: 12/27/2021 Design Wind Speed(Vult) - 160mph 3 sec gust, Total Wattage: 9,360w 8212 Amalfi Cir Drawn by: zu Exposure Category - C Roof Type: Composition Shingles Fort Pierce, FL Revised by: Wind Load: 27 to 45 Deg Rev #• 00 -Designed as per ASCE7-16 Fastener Type: Use 5/16" Dia 4" Lags 34951 Rev Date: Page: S-2 Equipment list PHOTOVOLTAIC SYSTEM DC DISCONNECT 1 2 3 a o a 13 MAX POINT CURRENT:23.4 A / Apply to DC MAX POWER POINT VOLTAGE:400 VDC pp Y PV: MAX SYSTEM VOLTAGE:480 DC disconnect/inverter _ MAX CIRCUIT CURRENT:15 A _- (26) Silfab-SIL 360 NX WARNING ELECTRIC SHOCK HAZARD Apply to each J box, combiner (26) SolarEdge Power Optimizer P401 THE DC CONDUCTORS OF THIS box, disconnect,and device where PHOTOVOLTAIC SYSTEM ARE energized, ungrounded circuits 1 2 3 0 0 0 1 3 (1) string of(13) UNGROUNDED AND MAY BE (1) string of(13) ENERGIZED maybe exposed during service. o 0 o - Inverter: (1) SolarEdge SE760OH-US Power Optimizer SolarEdge AC/DC Safety Switch r-sox TIP AC Disconnect: 60A Disconnect All wiring to meet the 2017 NEC and 2018 Energy Code O(4)#10 AWG Wire Main Service (1)#8 EGC SolarEdge Inverter —IT20 200A ! WARNING ! In 3/4"EMT typ or SE760OH-US FMC PVC LFNC w/Integrated Disconnect 0A Bus POWER SOURCE OUTPUT CONNECTION: > > DO NOT RELOCATE THIS OVERCURRENT (depending On route t0 DEVICE inv.Metal if interior) _ Utility PV AC Disco Manual Lockable Disconnect PHOTOVOLTAIC . 6oA 4oA DISCONNECT ! Donnie C Non-Fused � J`�GNAD��oo�o, RATED AC OUTPUT CURRENT: 32A Godwin Engineering and Godwin �,,,� V\G ENSF•,�2���, Disconnect Design, LLC No 81360 - NOMINAL OPERATING VOLTAGE: 240VAC N * :* 2021 .12.' ' ° - LocatedAdjacenttoUtilityMeter 8378 Foxtail Loop =�'. STATE OF #8 AWG THWN G Cc'+�OR\�p (2)Hot Pensacola, FL 32526 28 �'SS ONA� ?G°� Inverter Output Ckt (')Neutral III T "" ""'° � #8 AWG THWN #8 AWG EGC (2)Hot GEC D. C ad Godwin, PE (� All 1-1111 in @least 3/4"Conduit Typically (1)Neutral 12.2 •1 7 eA EGo�11 _:.'T�s�'� M 11 To Overcurrent Protection Device 1)AWG l Chad@godwineng.com Ne A E E moN,1.11 AC Max Output Current 32 in @ least 3/4"Conduit Typical l 100106— AC Max Output Current * 1.25% 40 Overcurrent Protection A 40 Load Side Connection No. of Current Carrying Cond <4 Busbar Rating 200 Conductor Gauge AWG 8 Main Breaker Size 200 Bus Rating*1.2-Main Break Size 40 AC/DC Solar LLC Max Allowable Load Side 40 Load side connection Per 705.12(B)(2)(3)(b) Load Side Breaker Size 40 605 W Lumsden Rd, System meets the grounding requirements of NEC 690.43 Use Matching or equivalent approved breaker if derating Brandon, FL 33511 Including the label below GEC NOTES Customer Info• Note: - Ungrounded system per 690.41(A)(4) 855-577-7999 -All wiring to meet the 2017 NEC and - GEC must be installed per 250.64 Date• 12/27/2021 - GEC must be continuous un-spliced or irreversibly spliced from In Case of Emergency Call Florida electric codes. inverter to existing service ground system or continuous from the Matthew Lewis ZU Inverter Type: Drawn b c LLC T (� 60A Disconnect arrays to the existing service ground system. 3' SolarEdge ACDC Solar LLC - GEC must be min#8 AWG and installed in conduit 8212 Amalfi Cir Revised b • PV Panel: -Type of conduit to be determined - If GEC is not in conduit,it must be#6 min (26) at 85 5-577-7999 Disconnects will be Visible,lockable,adjacent to Fort Pierce, FL Rev #: 00 Silfab-SIL 360 NX on site by contractor. and within 10'of utility meter Total Wattage: All Labels&Markings for photovoltaic system will be 34951 Rev Date: 9,360W Meets 11.12.2.1.5 Install will be done to Manufacturer Spec reflective and meet all requirements for NFPA 11.12 L Page: E-1 1 EMERGENCY The Placard shall be permanently -A placard will be added with PV Source Ckt © ,• • ma _ •riveted...,and shall be made of red, instructions and locations to be • ' weatherproof,hard plastic,with in compliance with 690.12, Distance above roof Y2 in.-3 Y2 in 310. EQUIPPED •D D• Inverter Output Ckt b f 15B( engraved white block lettering. 690.56 B and NEC 705.10 0 ( ) To Overcurrent Protection Device Amb.Temp.Adder for Rooftops( F) 40 TURN RAPID SHUTDOWN A R N I N SWITCH TO THE'OFF' Design bTemperature(F) Temp Ran a(F 94°F Design temperature °F 136.8 POSITION TO SHUT DOWN Rapid Shutdown Built in In COmphariCe with NEC MaxAmbTempRange(F) 87-95 310.15(B)(2)(a) THE ENTIREPVSYSTEM. p Adjusted Temp. Range for Roof 132-140 310.15(B)(2)(a) ELECTRIC SHOCK HAZARD 250.$8,NEC 690.8, Temp Rating of Conductors(C) 75°C DO NOT TOUCH TERMINALS. 6 Per Code NEC 690.12 NEC 250.24,NEC250.24(D) Current Carrying <4 310.15(B)(3)(a) Temp.Ratin of Conductor 900C TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED AC Max Output Current 32A 690.8(A)(3) No. of Current Carrying Cond. 4-6 310.15(B)(3)(a) IN THE OPEN POSITION. 690.17E NEC690.SG(C)(1)AND NFPA111.12.2.1.1.1.1,t1.t2.2.1.4 AC Max Output Current*1.25% 40A 690.8(B) Max Source Circuit Current 15 690.8(A)(5) PV AC disconnect is Conductors have a min Overcurrent Protection(A) 40ANEC 690.35 lockable in the open position ampacity of 60 amperes Amp Temp Correction Factor 0.94 310.15(B)(2)(a) Max Source Circuit Current* 1.25% 18.8 690.8(B)(1) per code NEC 705.22(7) Per Code NEC 230.79(D) Raceway Fill adjustment Factor 1o0% 310.15(B)(3)(a) Amb. Temp Correction Factor 0.71 310.15(B)(2)(a) zt WARN I N Wire Size(Awg) 8 310.15(B)(16) RacewayFill Adjustment Factor 80% 310.15(B)(3)(a) Everything will be built to Code without all Specifics labeled on plan Cond.AllowableAmpacity(A) 50A Cond. Gauge AWG 10 310.15(B)(16) THIS SERVICE METER Cond Adjusted Ampacity(A) 47A 50A*1*0.94=47A i IS ALSO SERVEDBYA System is in complaince with FFPC 1:11.12 7th Edition. AmpacitycnecklPer69o.s(B)(1) Pass 32A*1.25 40A<SOA Pass Cond.Allowable Ampacity(Amps) 40 Ampacity Check 2 Per 690.8(B)(2) Pass SOA*0.94A*1=47A>32A Pass Cond.Adjusted Ampacity(Amps) 23 40*.71*.8=22.7 PHOTOVOLTAIC SYSTEM 705.12(B)(3) Smoke Detectors will be added as per FBC 553.883 All Exterior equipment is A minimum of Nema-R3 Rated In compliance with 230.71 All Interactive System(S) Points of interconnection ! Markings shall be placed on all DC Conduits,DC Combiners, with other sources shall be marked at an accesible WARN ING:PHOTOVOLTAI Raceways,Enclosures,Junction Boxes,and Cable Assemblies location at the disconnecting means as a power POWER SOURCE POWER SOURCE at every 10',turns,and above and below penetrations in source and with the rated ac output current and the OUTPUT CONNECTION compliance with NFPA nominal operating AC voltage. Per NEC 690.54 DC to DC Converter Current Per String- 15A DO NOT RELOCATE THIS SOLAR PV SYSTEM EQUIPPED OVERCURRENT DEVICE TEXT WITH RAPID SHUTDOWN Disconnect means Shall be provided for all Disconnect is in compliance 230.72 Permanent sticker added to disconnect 3/81N MIN. 705.12(B)(2)(3)(b) disconnecting all ungrounded conductors that supply TURN RAPID or pass through the building or structure Per Code SHUTDOWN SWITCHT 2017 NEC Section 225.31 & Section 225.32 Supply side disconnect adjacent to Msp In Case Of Emergency Call Apply to Main Disconnect 3/161N MIN.TEXT THESHOUT^DOWNIPV Twpm 8 AWARNING ACDC Solar LLC999 SYSTEM AND REDUCE PHOTOVOLTAIC POWER SOURCE E04. Construction documents specify PV system circuits at 855-577-7999 SHOCK HAZARD IN THE Over Current Protection Device is "Next size up" ARRAY. installed tr or in buildings include a rapid shutdown function Based on Inverter Maximum Continuous Output NEC 690.31 (G)(3) that controls specific conductors in accordance with NEC Current Rating 2017 NEC 240.4(B) Load side connection will be done in Main Service Panel inside Home article 690.12. Figure 690.56(C)(1)(a) Label for PV Systems that Labels will be placed Shut down the array and the conductors leaving the array E05.These construction documents specify that a label is -All new equipment Y g Y In the Correct location -Markings Shall Be reflective,Weather Resistant and suitable for the environment. provided with the method to initiate rapid shut down per located adjacent to 3„ �y AD'�Opp p p Per Code NEC 69O.S6(B) -Markings Shall be red with white lettering with minimum a Capital Letters DUAL POWER SUPPLY ,,�� 690.12(4). Meter on exterior wall SOURCES:UTILITY GRID AND *.j N.81360 ,* 690.56(C),&690.53 PV SOLAR ELECTRIC SYSTEM q 3 Note: Godwin Engineeringd FTgTE of :4� E06. Construction drawings specify buildings or structures Metallic conduits, raceways or flexible metal conduit an ,F•.,(�q,pP �,. with both utility service and a PV system,complying with NEC exceeding6 feet in length are not permitted in accordance -Subject PV Systems has been designed SSONA�E;° 9 p Design, LLC article 690.12 shall have a permanent plaque or directory with NEC article 690.31(G). to meet the requirments of the NEC 2017, INVERTER OUTPUT CONNECTION: 8370 FOXtaII Loop including the following wording: "PHOTO VOLTAIC SYSTEM and those set forth by the Florida Solar DO NOT RELOCATE THIS ° EQUIPPED WITH RAPID SHUTDOWN"as per NEC article Include required label for metallic raceways and conduits to OVERCURRENT DEVICE Pensacola FL 32526 sheet E-1 per NEC article 690.31(G)(3). Energy Center Certification, Including )o n n i e C Godwin 690.56(C). Maximum Number of Module Strings, I WARN I D. Chad Godwin, PE p Add required label to sheet E-1 per NEC article 705.10. p g, E07. Construction documents specify PV power circuit labels Maximum number of modules per string, POWER SOURCE OUTPUT CONNECTION: Chad@godwineng.com 2021 •12.28 shall appear on every section of the wiring system that is Include required label to sheet E-1 per NEC article 705.12(B) Maximum Output, Module Manufacturer and DO NOT RELOCATE DEVTHIS ICE OVERCURRENT I I separated by enclosures,walls, partitions,ceilings, or floors. OO O6- 1 2:23:3 1 Photovoltaic AC disconnect shall be capable of being locked model number, inverter manufacturer and model WAR E08. Construction documents specify all warning sign(s)or in the open position per NEC article 705.22(6). number, as applicable. DEDICATED SOLAR PANE label(s)shall comply with NEC article 110.21 (B). Label NorcoNNEc7 <; warnings shall adequately warn of the hazard. Labels shall be Photovoltaic AC Overcurrent protection shall be located NEC 705.10 A permanent plaque or directory,denoting the location of LOADS WAR g q y within 10 feet of the point where conductors are connected to all electric power source disconnecting means on or in the premises,shall 4 permanently affixed to the equipment, and Labels required the service per NEC 705.31. be installed at each service equipment location and at the location(s)of TOVOLTAIC S AC/DC Solar LLC shall be suitable for the environment. the system disconnect(s)for all electric power production sources capable EQUIPPED WIT of being interconnected.One sign required for each PV system. RAPID sl+uroowN 605 W Lumsden Rd, System meets the grounding requirements of NEC 690.43 Plans Satisfy NEC 250.94&NEC250.53(A)(2) Brandon, FL 33511 Including the label below GEC NOTES Customer Info: 855-577-7999 - Ungrounded system per 690.41(A)(4) - GEC must be installed per 250.64 Date• 12/27/2021 - GEC must be continuous un-spliced or irreversibly spliced from In Case of Emergency Call inverter to existing service ground system or continuous from the Matthew Lewis Drawn b : ZIJ Inverter Type: AC ( � c LLC arrays to the existing service ground system. y SolarEdge ACDC Solar LLC - GEC must be min#8 AWG and installed in conduit 8212 Amalfi Cir Revised b • PV Panel: - If GEC is not in conduit,it must be#6 min (26) at 855-577-7999 Disconnects will be Visible,lockable,adjacent to Fort Pierce, FL Rev #: 00 Silfab-SIL 360 NX and within 10'of utility meter 34951 Rev Date: Total Wattage: All Labels&Markings for photovoltaic system will be 9,360W Install will be done to Manufacturer Spec reflective and meet all requirements for NFPA 11.12 1 Page: E-2 OL — Proposed Mounting locations a E: © © L � 0 0L L L © L © (D 0 261-911 L o� L o © � L� 26�_5 t� O O ® O ❑ ° O L O O Iron Ridge XR-100 Rail L L L L L 171 3 ° 10 53'-811 L 4'-611 R-1 R-2 # Modules (20) # Modules (6) 3'- Pitch: 30' Pitch: 30' 3" 4 -S e Bar Azimuth: 182' Azimuth: 92' 6'-0" 59 Unirac Flashloc 66 Iron Ridge UFO's Plans satisfy zones FBC-1510.7.1 28 Iron Ridge Sleeves/End Caps 2 Roof Top Combiner Install will be done to Manufacturer Spec 7 Iron Ridge Ground Lugs 26 Silfab-SIL 360 NX ' ' N.81360 26 SolarEdge SE760OH-US Godwin Engineering and SolarEdge P401 Optimizers Design, LLC 1 60A Non-Fused Disconnect 8378 Foxtail Loop - 1 40A Breaker Pensacola, FL 32526 Donnie CM Godwin D. Chad Godwin, PE 2021 .12.28 Chad@godwineng.com '00'06- 12:23:41 ACIDC Solar LLC Max cantilever is 16" as per manufacturer spec. Zone 1: 605 W Lumsden Rd Max Cantilever Max Span (3)=48 (3)-16 Customer Info. Brandon, FL 33511 Max cantilever is 16" as per manufacturers spec. Inverter Type: SolarEdge SE760OH-US p p 855-577-7999 Zone 2e: PV Panel: (26) Silfab-SIL 360 NX Max Cantilever = Max Span * (3)=48"*6)=16" Matthew Lewis Date: 12/27/2021 Max cantilever is 8" as per manufacturer spec. Racking: Iron Ridge XR-100 Zone 2r: Total Wattage: 9936OW 8212 Amalfi Cir Drawn by: zu Max Cantilever = Max Span * 6)=24"*(3)=8" Roof Type: Composition Shingles Fort Pierce, FL Revised by: Max cantilever is 8" as per manufacturer spec. Wind Load: 27 to 45 Deg Rev #: 00 Max Cantilever = Max Span * (3)=24"*(3)=8" Zone 3: Fastener Type: Use 5/16" Dia 4" Lags 34951 Rev Date: Page: S-1 A Electrical Specifications SIL-360 Test Conditions STC NOCT Module Power(Pmax) Wp 360 258 ���� Maximum power voltage(Vpmax) V 36.6 33.1 Maximum power current(lpmax) A 9.9 7.8 �� Open circuit voltage(Voc) V 44.5 40.4 I \� , ' NXShort circuit current(Isc) A 10.5 8.2 S " If a Module efficiency % 19.7 17.6 Maximum system voltage(VDC) V 1000 SOLAR Series fuse rating A 20 Power Tolerance Wp 0 to+10 Measurement conditions:STC 1000 W/m2•AM 1.5•Temperature 25'C•NOCT 800 W/m=•AM 1.5•Measurement uncertainty<3% a.A •Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by 0 to+10W. AUxOMATEO ..°nM Temperature Coefficient Isc +0.064%/°C Temperature Coefficient Voc -0.28%/°C Temperature Coefficient Pmax -0.36%/°C NOCT(±2°C) 46°C OperatingINDUSTRY LEADING WARRANTY Mechanical temperats and ure Components •-4o/ moo , All our products include an industry Metric Imperial leading 25-year product workmanship Module weight 20±0.2 kg 44±0.4lbs and 30-year performance warranty. Dimensions(H x L x D) 1832 mm x 1000 mm x 38 mm 72.13 in x 39.4 in x 1.5 in a D Maximum surface load(wind/snow)* 4000 Pa rear load/5400 Pa front load 83.5/112.8 Ib/ftA2 35+YEARS OF SOLAR INNOVATION Hail impact resistance o 25 mm at 83 km/h o 1 in at 51.6 mph g y Leveraging over 35+ ears of worldwide Cells 66-Si mono-PERC-5 busbar 66-Si mono-PERC-5 busbar 158.75 x 158.75 mm 62.25 x 62.25 in experience in the solar industry,Silfab Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, is dedicated to superior manufacturing DSM anti-reflective coating DSM anti-reflective coating Cables and connectors(referto installation manual) 1200 mm o 5.7 mm,MC4 from Staubli 47.2 in, o 0.22(12AWG),MC4 from Staubli processes and innovations such as Bifacial and Back Contact technologies, Backsheet High durability,superior hydrolysis and UV resistance,multi-layer dielectric film, fluorine-free PV backsheet to ensure our partners have the latest in Frame Anodized Aluminum(Black) ® solar innovation. Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL 3730 Certified,IEC 62790 Certified,IP67 rated NORTH AMERICAN QUALITY •/ NX mono ' RC • Silfab is the leading automated solar Module product workmanship warranty 25 years** module manufacturer in North America. Linear power performance guarantee 30 ears1. p p g >_97.1%end 151 year >_91.6%end 12 h year >_85.1%end 25th year >_82.6%end 301h year, Utilizing premium quality materials and _ _ = strict quality control management to deliver ULC ORD C1703,UL1703,CEC listed***•UL 61215 1/1 1/2,UL 61730 1/2, e the highest efficiency,premium quality Product IEC 61 21 5-1/-1-1/-2***.IEC 61730-1/-2***,CSAC22.2#61730-1/-2,IEC62716 PV modules. Ammonia Corrosion;IEC61701:2011 Salt Mist Corrosion Certifed UL Fire Rating:Type 2 Factory IS09001:2015 .3 All states except California California eee Modules Per Pallet:26 eee Modules Per Pallet:26 1.5"[36mm] _ H.Pallets Per Truck:34 ee Pallets Per Truck:32 e o .:e Modules Per Truck:884 .ee Modules Per Truck:832 E • D,.inage(x8) E N *A Warning.Read the Safety and Installation Manual for mounting specifications and before handling, m umng Hae(m)N installing and operating modules. S - **12 year extendable to 25 years subject to regis- tration and conditions outlined under"Warranty'at o • •, • _ • • • • 1 1 • ,• • • • •, www.silfabsolar.com. 'ff E - • • �-•. • • • • • • • • progress. e ***Certification and CEC listingin • • • • ,• •, • • •• • • • • PAN files generated from 3rd party performance s E • • data are available for download at: N E 3 www.siIfabsolar.com/downloads. _ ' " C • • • • • • •- • - -• • • ••. - • •.• • • • • • •• • E o o •.• •. • • • �111• • • •. • • • • • • .• -• • •• • C C ° Silfab Solar Inc. • • •. • :1 _ i 240 Courtneypark Drive East 1.02"[26mm] } o Mississauga ON L5T2Y3 Canada • • • • • • • S i I fa b Tel+1 905-255-2501 1 Fax+1 905-696-0267 04.2..(x2) Grounding H.I. ar SOLAR info@silfabsolar.com I www.silfabsolar.com 910 ® Silfab Solar Inc. 39.37"3 [100 mm] o 37" 000mm] 800 Cornwall Ave _ Bellingham WA 98225 USA Tel+1 360-569-4733 Single Phase Inverter Wit HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ Single Phase Inverter SE760OH-US / SE10000H-US / SE1140OH-US ,,. ,.. ..., • � OUTPUT with HID-Wave TechnologyRated AC Power Output 3000 3800 @ 208V 5000 5000 @ 208V 7600 10000 10000 @ 208V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA for North America 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min. Nom. Max.64) ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / (211 AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ Vac SE760OH-US / SE10000H-US / SE1140OH-US ACFre Frequency AC Frequency(Nominal) 59.3-60-60.50I Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V YEAR solar ..: ., HD„,ove Maximum Continuous Output 16 24 48.5 A Current @208V GFDI Threshold 1 A V) Utility Monitoring,Islanding �. .1 U Protection,Country Configurable Yes solars ,„�� Thresholds INPUT c=) Maximum DC Power @240V 4650 5900 1 7750 9300 11800 1 15500 1 17650 W Maximum DC Power @208V - 5100 - 7750 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc • • • • see * Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240VO 8.5 10.5 13.5 16.5 20 27 30.5 Adc • n Maximum Input Current @208V(I) - 9 - 13.5 - 27 Adc Max.Input Short Circuit Current 45 Adc r Reverse-Polarity Protection Yes 2s = Ground-Fault Isolation Detection 600kQ Sensitivity Maximum Inverter Efficiency 99 99.2 % 98 CEC Weighted Efficiency gg 9. @ 240V .5 @ 208V ® Nighttime Power Consumption <2.5 W ! W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional(') Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect Optimized installation with HD-Wave technology 2017690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL16996,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Specifically designed to work with Extremely small Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) power optimizers Emissions FCC Part 15 Class B Record-breaking efficiency Built-in module-level monitoring INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG 3/4"minimum/14-6 AWG 3/4'minimum/14-4 AWG Range Fixed voltage inverter for longer strings Outdoor and indoor installation DC Input Conduit Size/#of Strings/ 3/4"minimum/1-2 strings/14-6 AWG 3/4"minimum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/ Integrated arc fault protection and rapid shutdown for Optional: Revenue grade data, ANSI C12.20 (HxWxD) mm NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy) Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 Ib/kg Noise <25 <50 dBA UL1741 SA certified, for CPUC Rule 21 grid Cooling Natural Convection compliance Operating Temperature Range -40 to+140/-25 to+60(4)(-40`F/-40°C option)(') °F/°C Protection Rating NEMA 4X(Inverter with Safety Switch) 0)For other regional settings please contact SolarEdge support s o I a r m A higher current source may be used;the inverter will limit its input current to the values stated I'I Revenue grade inverter P/N:SExxxxH-USOOONNC2 solaredge.com (4)For power de-ratinginformation refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf (5)-40 version P/N:SExxxxH-USOOONNU4 m SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All Ro H S other trademarks mentioned herein are trademarks of their respective owners.Date:1212018MVENG NAM.Subject to change without notice. Power Optimizer Power Optimizer mo P370 / P401 / P404 / P485 / P500 / P505 / P601 P370P401 ., P505 P601 OPTIMIZER MODEL (60&70 (60&70 (for 60-cell (for high (for 96-cell (for higher (for 1 x high UNIT, 0 (typical module compatibilty) Cell Cell and 72 cell, voltage modules) current powerPV P370 / P401 / P404 / P485 / P500 / P505 / P601 INPUT modules) modules) short strings) modules) modules) module) Rated Input DC PowWl 370 420 405 485 500 505 600 W Absolute Maximum Input Voltage 60 80 125 80 83 65 Vdc (Voc at lowest temperature) MPPT Operating Range 8-60 12.5-80 12.5-105 8-80 12.5-83 12.5-65 Vdc Maximum Short Circuit Current(Isc) 11 12.5 11 10.1 14 Adc Maximum Efficiency 99.5 % "25 O Weighted Efficiency 98.8 98.6 YEAR Overvoltage Category II WARRANTYOUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 1 15 1 Adc Maximum Output Voltage 1 60 80 60 80 1 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) - Safety Output Voltage per Power Optimizer 1 10.1 Vdc STANDARD COMPLIANCE EMC FCC Part 15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 - ROHS Yes N Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions(W x L x H) 129x153x27.5 129x153x29.5 129x153x42.5 129x159x49.5 129x153x33.5 129x162x59 129x153x52 Trim /5.1x6x1.1 /5.1x6x1.16 /5.1x6x1.7 /5.1x6.2x1.9 /5.1x6x1.3 /5.1x6.4x2.3 /5.1x6x2 /in Weight(including cables) 655/1.5 775/1.7 845/1.9 750/1.7 1064/2.3 gr/lb Input Connector MC40 Single or 3 MC412l 10Dual MC4 Input Wire Length 0.16/0.52,0.9/2.95 0.16/0.52 m/ft Output Connector MC4 Output Wire Length 1.2/3.9 1.4/4.5 m/ft Operating Temperature Rangel41 -40 to+85/-40 to+185 `C/T Protection Rating IP68 Relative Humidity 0-100 % (1)Rated power of the module at STC will not exceed the optimizer"Rated Input DC Power'.Modules with up to+5%power tolerance are allowed PV power optimization at the module level (3)For dual versionf for r types please contact SolarEdge (3)For dual version for parallel connection of two modules use the P485.In the case of an odd number of PV modules in one string,installing one P485 dual version power optimizer connected to one PV module is supported.When connecting a single module,seal the unused input connectors using the supplied pair of seals (4)For ambient temperature above+70°C/+158°F power de-rating is applied.Refer to Power Optimizers Temperature De-Rating Technical Note for more details Specifically designed to work with SolarEdge inverters / Superior efficiency(99.5%) PV System Design Using a Solaredge Inverter(') Single Phase Single Phase Three Phase Three Phase for Up to 25%more energy / Flexible system design for maximum space utilization ' 277/480V Grid Minimum String Length P370,P401,P500'e' 8 16 18 Next generation maintenance with module-level / Module-level voltage shutdown for installer and (Power Optimizers) P404,P485,P505,P601 6 14(13 with SE31<17I) 14 monitoring firefighter safety Maximum String Length(Power Optimizers) 25 50 50 / Mitigates all types of modules mismatch-loss,from / Fast installation with a single bolt Maximum Nominal Power per String") 5700 5250 112500I 12750110I W manufacturing tolerance to partial shading Parallel Strings of Different Lengths or Orientations Yes (5) It is not allowed to mix P404/P485/P505/P601 with P370/P401/P500 in one string (6)The P370/P401/P500 cannot be used with the SE3K three phase inverter(available in some countries,refer to the three phase inverter SE3K-SE10K datasheet) (7) Exactly 10 when using SE3K-RW010BNN4 (8)If the inverters rated AC power<maximum nominal power per string,then the maximum power per string will be able to reach up to the inverters maximum input DC power Refer to:https://www.solaredge.com/sites/default/files/se-power-optimizer-single-string-design-application-note.pdf (9) For the 230/400V grid:it is allowed to install up to 13,500W per string when the maximum power difference between each string is 2,000W (10) For the 277/480V grid:it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W so I a red g e.co m solar=@@ O SolarEdge Technologies,Ltd.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc. C E Al,othertrademarks mentioned herein are trademarks of their respective owners.Date:10/2021 DS-000047-2.2-ENG.subject to change without notice. /lam IRONRIDGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, fgrl but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing ; i enough to buckle a panel frame. XR Rails are the structural backbone preventing ,z XR10 XR100 XR1000 these results. They resist uplift, protect against buckling and safely and efficiently ®�®® � XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among transfer loads into the building structure. ®� �® rail,designed for regions with light or mounting rail. It supports a range of solar mounting rails.It's built to handle Their superior spanning capability / ® ® � no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 Q �®requires fewer roof attachments, while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. e�/���� reducing the number of roof 6'spanningcapability 10'spanningcapability 12'spanningcapability penetrations and the amount ®� Moderate load capability Heavy load capability Extreme load capability Clear&black anodized finish Clear&black anodized finish Clear anodized finish of installation time. y Internal splices available Internal splices available Internal splices available ® ® Rail Selection I ® The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. \ Force-Stabilizing Curve 90 Sloped roofs generate both vertical and lateral 120 forces on mounting rails which can cause them None to bend and twist.The curved shape of XR Rails 140 XR10 XR100 XR1000 is specially designed to increase strength in both directions while resisting the twisting.This unique 160 feature ensures greater security during extreme weather and a longer system lifetime. 90 120 � 20 140 160 9 30 0 160 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 XR Rails are IronRidge offers All XR Rails are made of 6000-series 40 compatible with a range of tilt leg aluminum alloy,then protected with an , 160 FlashFoot and options for flat anodized finish.Anodizing prevents surface other pitched roof ■■■ roof mounting and structural corrosion,while also providing . I 80 160 attachments. applications. a more attractive appearance. 120 160 'Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. GODWIN ENGINEERING AND DESIGN, LLC 8378 Foxtail Loop, Pensacola, FL 32526 1 (850)712-4219 1 chad@godwineng.com December 27, 2021 To: St. Lucie County Building Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Lewis - Residential PV Roof Mount Installation 8212 Amalfi Cir. Fort Pierce, FL 34951 Plan Reviewer, This letter is regarding the installation of a new roof mounted Solar PV System on the existing residential structure at the address above. I have reviewed the attachment plan and have determined that the roof mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction: 2020 Florida Building Code 71h Edition,FBC ASCE 7 Min. Design Loads for Buildings&Other Structures Per 2020 FBC,the Roof Mounted PV system will be subject to the following design criteria: Design Wind Speed(V,,,t) - 160mph 3sec gust, Exposure Category- C The PV System consist of the modules,railing,and connection hardware.The system will add a dead load of approximately 3 psf to the roof. The existing roof covering is Asphalt Shingle with min. 1/z" plywood decking and 2"x 4" roof trusses 24" O.C. The roofing,decking,and roof trusses are in good condition.The existing structure will be adequate for supporting the additional PV dead load and wind loads. The securement method of the PV system is to be flush mounted to the asphalt shingle roof with the Ironridge railing and flashings/attachments.The attachments can be attached up to 48" apart in roof zones 1 &2e,and 24"apart in roof zones 2r, &3.The mounts should be staggered,where possible,to allow distribution of the design loads evenly to the structure.The mounts shall be installed with a min. 5/16"lag screw with minimum 2-5/16"thread length. Please see attached documents and contact me should you have any questions. Donnie CP'D Go /.�'�'. Sincerely, Godwin, No 81360 ;.* - Tt D. Chad Godwin, PE 81360 9 STATE OF 4U Exp. 02/28/2023 2021 .12.2Al 12:2 3:5 2 8 THIS TEM HASOB'EE'NN ECTR"N CALLV SIGNED AND SEALED BY DONNIE CH AD GOD—USING A DIGITAL SIGNATURE AND D TE,PRINTED COPIES OF DOCUMENT AND 100106 ANDTOHESGNATURE M USCONSIDEREDGTBESVERFEDOND ANY ELECTRONIC COPIES ASCE 7-16 CHAPTER 29 WIND LOADS-Rooftop Solar Panels Minimum Design Loads-Part 1:Enclosed(Gable,Hip,Flat h<60ft,0*<6<45*) Wind Load Parameters-Inputs Wind Load Paramaters Risk Category II Table 1.5-1 Wind Speed(asd) 124 mph FRC R301.2.1.3 Basic Wind Speed(Ult) 160 mph Figure 26.5-1B Effective Wind Area 19.72 It' 26.20 Roof Angle 28°to 45' Wind Directionality Kd 0.85 Table 26.6-1 Roof Type Hip Topographic factor Ka 1.00 26.8 or 26.8.2 Exposure Cat. B,C,or D C Section 26.7 Ground Elevation Factor K* 1.00 Table 26.9-1 Mean Roof Height h 15.00 ft Velocity Exposure Coefficient Kr 0.85 Table 26.10-1 Roof attachment 5/16"x 4"Lag Screw Array Edge Factor yr 1.50 29.4.4 *Modules are considered Exposed Rafter/Truss Spacing 24 in O.C. Solar Panel Equalization Factor y, 0.68 Fig.29.4-8 No.of Rails 2 Velocity Pressure qn 28.41 psf qn=0.00256 K,K„Kki No.of Modules-Portrait 26 Added Safety Factor 1.2 No.of Modules-Landscape 0 Allowable Pullout per mount 709.6 Ibs Module Model Number SIL-360 NX 0.4h or 0.6h 6.00 ft Flat-0.6h,Gable,Hip-0.4h bldg.least horizontal dim(typ.) 180 10%of least horizontal dim 1.50 ft -vflexnnor.oim.oro.dn,wmmever�::moose WtnvJ-man silly-fteanhor.or Elevation <5000 ft Roof Zone Set Back a 3.00 ft arc.(nar roof-0.6h) Est.#of attachment points 59 h2 5 in rva>ioin(panel neitnran-oof) PV Dead Load Module and Racking Spm 2hz r 30 in mmai:xa"rea,ray,nao de ftom me roa eaxe,sable ndfse,or hipridge #of Modules 26 Dimensions,LxWxH(in) 72.13 x 39.37 x 1.5 0.25 in mpg.p rw- cis der no11s.7ft Module Wmoa 44 Ibs Width 3.28 ft all 1.00 ft I a p eiedxe Array Wmoa, 1144 Ibs Length 6.01 ft d2 0.25 ft rvorao--a"re I- a p,oeim me pearen edx-me oea row Micro/optimizer W- 104 Ibs Module Area 19.72 ft` 0.5h 7.50 ft *moawes.rewo:iaeree.po::e ma.rewrtnm s.sip rrom roor.et. PV Rail W1 rA 18 Ibs Module load ratings Notes Total Weight W,oei 1266 Ibs Ultimate Allowable Total Area AT 512.73 ftz Load Rating-Snow(psf) 1 113.4 75.6 Eq.1 Point Load=Roof Zone psf*TA Dead Load D, 2.47 psf Load Rating-Wind(psf) -84 -56.0 Eq.2 TA=(Module Length/2)*Max Span Weight/attachment 21.S Ibs Eq.3 *Max span Equation,SF Allowable pullout/Point Load PVAttachni-Results Eq.4 Max Span=Allowable Pullout/(SF*Roof Zone psf Roof Zones-Hip 28'to 45' 1 2e 2, 3 a)The Max span between attachment points must not exceed the rail spans provided by racking manufacture. GCp-Uplift -1.4 -1.5 -2.1 -2.1 GCp-Down 0.7 0.7 0.7 0.7 b) Allowable Module load ratings are determined by SF=1.5 P=gn(GCo)(ye)�ya) -38.2 -41.1 -58.6 psf 29.4-7 P=gn(GC,)(yr)(y,) 20.3 20.3 20.3 20.3 psf 29.4-7 Max Allowable Span 4 4 2 2 ft *notes Max Cantilever(in) 16 16 8 8 Max span*33%(in) ,,,,,,GNADi�Gog,"..i Donnie C Godwi n= No 81360 2021 .12.210. STATE 4u 12:2 4:11 8 THIS ITEMHASS BEENA,ELECTRONICALLY SIGNED AND SEALED BY DONNIE CHAD 6 GOD IN USING A DIGITAL SIGNATURE AND D TE.PRINTED COPIES OF THIS DOCUMENT ARENREDAND '00'0 ANDTOHESGNAITEREM STSEDVERIFIEDLON ANY ELECTRONIC COPIES