HomeMy WebLinkAboutLetter; Termite treatment....
•� . •_��•r:r:.. 'ice vie+:�� '\�`��
F=
Nuelle Engineering Date:10/1712015
Donald J. Nuelle P.E.
815 University Boulevard Apt. 301
Jupiter, FL 33458
Cellular 561.629.6975
GHO Homes .
590 NW Mercantile Place
Port St. Luds, FL 34988
Alin: Bill Handier
Re: Termite Treatment Option
Dear Mr. Handler.:
Per your request, I have inspected the termite treatment requirements in
the FBC and Iind the belting method (which is used on all GHO homes) should
have been specified on the foundation notes instead of the soli treatment. The
soil treatment note Is an error and should be omitted.
R318.1 .7
If a registered termilicide formulated and registered as a bail system is used for
subterranean termite prevention, Section R318.1.1 through Section R318.1 Ado not apply,
however, a signed contract assuring the Installation, rn lenence and mordtortng of the
trattin@ system that is In compliance with the requirements of Chapter 482, Florida Sfafufes,
shall W provided to the building official prior to the pouring of the slab. and the system must
be fnstaped poor to final building approval
If you or any other Interested party has any questions or requires
additional Information please feel free to contact me at any time.
® J. Nuelle RE
•.. rr9 �
P.E.9 04