Loading...
HomeMy WebLinkAboutProject Information+ wrightsoft® Load Short Form Entire House For: MW-64 2644 CONIFER DR, FORT PIERCE, FL34951 Job: Date: Jul 30, 2021 By. Htg Clg Infiltration Outside db (°F) 43 91 Method Simplified Inside db (OF) 70 72 Construction quality Average Design TD (OF) 27 19 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (grflb) 0 65 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond ML14XClS036-230C** AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.3 kW Sensible cooling 24220 Btuh Heating output 24817 Btuh Latentcooling 10380 Btuh Temperature rise 20 OF Total cooling 34600 Btuh Actual airflow 1153 cfm Actual airflow 1153 cfm Airflowfactor 0.048 cfm/Btuh Airflowfactor 0.051 cfm/Btuh Static pressure 0 in H2O t Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.69 ROOM NAME Area (ft2) Htg load (Btuh) Clg load ` (Btuh) HtgAVF (cim) CIgAVF (cfm) MASTER SUITE 312 4855 3646 235 187 HER W IC 60 928 523 45 27 MASTER BATH 169 1784 2220 86 114 BED 2 205 2926 3300 141 169 UTILITY 73 1101 993 53 51 BATH 2 79 64 366 3 19 FOYER 91 754 558 36 29 DINING 131 3533 2743 171 140 KITCHEN 153 1600 2327 77 119 DEN 181 3340 2375 161 122 (1RFAT PRA ZF() 7071 '2A 77 4 AA 470 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. . wrightsoft® 2021-Jf-3013:43:54 i� aM�•�����tiw=r��mwm NgilSute®Uruversal202121.0.05RSU29964 Page +CA...ersWrryUserlDownervts\WdghsoftHVACVM-64.np Calc=MJ8 FrorMoorfaces: N Entire House 1815 23856 22524 1153 1153 Other equip loads 0 0 Equip. @ 0.95 RSM 21510 Latent cooling 10068 Tl1TA1 C 41 r;'70 11 G4 41 r.4 v 1 �I V I V L-- - w I. -- I. -I Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsoft- '� .MR�� •e .•��•mwq Right-Sute®Uriversa1202121.0.05RSU29964 +�...ersW.ryUserTomments\WrightsoftHVACWIW-64.rrp Calc=MJ8 Frorft Door faces: N 2021-JV-3013:43:54 Page 2 wrightsoft® Project Summary Entire House Job: .Date: Jul 30, 2021 By. Project Information =2 For: MW-64 2644 CONIFER DR, FORT PIERCE, FL 34951 Notes: Design Information Weather: Vero Beach Municipal AP, FL, US Winter Design .Conditions. Summer Design Conditions Outside db 43 OF Outside.db 91 OF Inside db 70 OF Inside db 72 OF Design TD 27 OF Design TD 19 OF Daily range L Relative humidity 50 % Moisture difference 65. grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20676 Btuh Structure -19.118 Btuh Ducts 3179. Btuh Ducts 3406 Btuh Central .vent (0 cfm) 0 Btuh Central vent (0 cfrri) 0 Btuh. (none) (none) . r Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23856 Btuh Use manufacturer's data n Rate/swing multipplier Equipmentsensibleload 0.95 21510 Btuh Infiltration Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 8554 Btuh Ducts 1514 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 1815 1815 Equipment latent load 10068 Btuh Volume (f?) 17827 17327 Airchanges/hour . 0.38 0.20 Equipment Total Load (Sen+Lat) 31578 Btuh Equiv AVF (cfrn) 110 58 Req. total capacity at 0.70 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary . Make 1 Make Lennox Trade Trade LENNOX Model Cond ML14=S036-230C** AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating Input 7.3 kW Sensible cooling 24220 Btuh Heat ngOutput 24817 Btuh Latentcooling 10380 Btuh Temperature rise 20 OF Total cooling 34600 Btuh Actual airflow-. - 1153 cfrn Actual airflow 1153 cfrn Airflowfactor 0.048 cfmBtuh Airflowfactor 0.051 cImBtuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.69 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -Fl&- wrightsoft® 2021-JU-3013.43:54 •Mrti4• a••� »�•w•-••mm• • Right-SUte� Urrversa12021 21.0.05 RSU29964 Page 1 erslAryUserlDommenMWdghtsoftHVAGM-64.nQ Calc=MJ8 FrortDoorfams: N DO NOT SCALE PLANS TSTAT SHALL BE WITHIN 3 FEET HORIZONTALLY OF MAIN RETURN V / W 0) .4- OOf �r) LL- _ ry �W �w zU O Z OLLLI a_ �ry O 04�