HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 F ���
FLORIDA ENERGY IENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: DOTY AND BROWN RESIDENCE
Builder Name: ASSOCIATED HOMES, INC.
Street: 6013 SPRUCE DRIVE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: JAMES DOTY AND RILEY BROWN
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or epsting New (From Plans)
10. Wall Types(2054.6 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Polystyrene Bead Aggr93=9.0 1828.20 ft2
b. Frame - Wood, Adjacent
R=11.0 226.33 ft2
3. Number of units, if multiple family - 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
11. Ceiling Types (2190.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 2190.00 ft2
6. Conditioned floor area above grade (ft2) 2190
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(210.3 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
R ft2
6 150
a. U-Factor: Sgl, U=0.63 168.30 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.67 42.00 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.23
a. Central Unit
35.2 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.246
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2190.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2190.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
None
Total Proposed Modified Loads: 62.11
Glass/Floor Area: 0.096
PASS
Total Baseline Loads: 66.61
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
S' _
Code.
calculation indicates compliance
y� �I;, ' _ .�VIA.
' n�y hhkt-
with the Florida Energy Code.
y
�...f
PREPARED BY: lJrl
DATE: 6-7-2021
Before construction is completed
this building will be inspected for
compliance with Section 553.908
a
I hereby certify that this building, as designed, is in compliance
Florida Statutes.0
with the Florida Energy Cod
OWNER/AGENT
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation'Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
6/3/2021 4:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
DOTY AND BROWN RESIDE
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned
Area:
2190
Lot #
Owner Name:
JAMES DOTY AND RILEY
BR
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
ASSOCIATED HOMES, INC.
Rotate Angle:
0
Street:
6013 SPRUCE DRIVE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House
Fan:
No
City, State,
Zip:
FORT PIERCE,
Family Type:
Detached
FL,
New/Existing:
New (From Plans)
Comment:
SEDONA VISTA 4/3- GARAGE LEFT
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range .
FL, Fort Pierce Fl.VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2190
19949
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
MASTER BEDROO
218
1983.8
No
0
1
1
Yes
Yes
Yes
2
WIC 1
32
259.2
No
0
1
Yes
Yes
Yes
3
WIC 2
36
291.6
No
0
1
No
Yes
Yes
4
MASTER BATH
174
1409.4
No
0
1
Yes
Yes
Yes
5
DEN
151
1525.1
No
0
1
Yes
Yes
Yes
6
FOYER
104
1050.4
No
0
1
Yes
Yes
Yes
7
DINING ROOM
143
1444.3
No
0
1
Yes
Yes
Yes
8
FAMILY ROOM
320
3232
No
0
1
Yes
Yes
Yes
9
KITCHEN
190
1919
Yes
0
1
No
Yes
Yes
10
NOOK
88
888.8
No
0
1
Yes
Yes
Yes
11
BEDROOM 2
139
1125.9
No
0
1
1
Yes
Yes
Yes
12
CLST 2
16
129.6
No
0
1
No
Yes
Yes
13
CLST 3
18
145.8
No
0
1
Yes
Yes
Yes
14
LAUNDRY
66
534.6
No
0
1
No
Yes
Yes
15
HALLWAY
65
526.5
No
0
1
No
Yes
Yes
16
M. TOILET
32
259.2
No
0
1
Yes
Yes
Yes
17
CLST 4
18
145.8
No
0
1
No
Yes
Yes
18
BEDROOM 4
129
1044.9
No
0
1
1
Yes
Yes
Yes
19
BATH 3
66
534.6
No
0
1
Yes
Yes
Yes
20
BEDROOM 3
137
1109.7
No
0
1
1
Yes
Yes
Yes
21
BATH
48
388.8
No
0
1
Yes
Yes
Yes
6/3/2021 4:23 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO
39 ft
0
218 ft2
___-
0
1
0
2 Slab -On -Grade Edge Insulation
WIC 1
8 ft
0
32 ft2
-- -
0
1
0
3 Slab -On -Grade Edge Insulation
WIC 2
1 ft
0
36 ft2
____
0
1
0
4 Slab -On -Grade Edge Insulation
MASTER BATH
22 ft
0
174 ft2
____
0
1
0
5 Slab -On -Grade Edge Insulation
DEN
15 ft
0
151 ft2
----
0
1
0
6 Slab -On -Grade Edge Insulation
FOYER
8 ft
0
104 ft2
_-__
0
1
0
7 Slab -On -Grade Edge Insulation
DINING ROOM
11 ft
0
143 ft2
0
1
0
8 Slab -On -Grade Edge Insulation
FAMILY ROOM
16 ft
0
320 ft2
_-__
0
1
0
9 Slab -On -Grade Edge Insulation
KITCHEN
1 ft
0
190 ft2
__-_
0
1
0
10SIab-On-Grade Edge Insulation
NOOK
8 ft
0
88 ft2
____
0
1
0
11SIab-On-Grade Edge Insulation
BEDROOM 2
19.9 ft
0
139 ft2
____
0
1
0
12SIab-On-Grade Edge Insulation
CLST 2
1 ft
0
16 ft2
___-
0
1
0
13SIab-On-Grade Edge Insulation
CLST 3
2 ft
0
18 ft2
___-
0
1
0
14SIab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
66 ft2
___-
0
1
0
15SIab-On-Grade Edge Insulation
HALLWAY
1 ft
0
65 ft2
____
0
1
0
16SIab-On-Grade Edge Insulation
M. TOILET
12 ft
0
32 ft2
__-_
0
1
0
17SIab-On-Grade Edge Insulation
CLST 4
1 ft
0
18 ft2
-___
0
1
0
18SIab-On-Grade Edge Insulation
BEDROOM 4
11 ft
0
129 ft2
____
0
1
0
19SIab-On-Grade Edge Insulation
BATH 3
6 ft
0
66 ft2
----
0
1
0
20SIab-On-Grade Edge Insulation
BEDROOM 3
24 ft
0
137 ft2
____
0
1
0
21SIab-On-Grade Edge Insulation
BATH
5 ft
0
48 ft2
----
0
1
0
ROOF
Roof
Gable
Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip Composition shingles 2449 ft2
0 ft2
Medium
N
0.6 No 0.9
No
0
26.57
ATTIC
RBS IRCC
V # Type
Ventilation
Vent Ratio (1
in)
Area
1 Full attic
Vented
300
2190 ft2
N N
6/3/2021 4:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY GFIEGKL.IST REPURT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) MASTER BEDRO
30
Blown
218 ft2
0.1
Wood
2
Under Attic (Vented) WIC 1
30
Blown
32 ft2
0.1
Wood
3
Under Attic (Vented) WIC 2
30
Blown
36 ft2
0.1
Wood
4
Under Attic (Vented) MASTER BATH
30
Blown
174 ft2
0.1
Wood
5
Under Attic (Vented) DEN
30
Blown
151ft2
0.1
Wood
6
Under Attic (Vented) FOYER
30
Blown
104 ft2
0.1
Wood
7
Under Attic (Vented) DINING ROOM
30
Blown
143 ft2
0.1
Wood
8
Under Attic (Vented) FAMILY ROOM
30
Blown
320 ft2
0.1
Wood
9
Under Attic (Vented) KITCHEN
30
Blown
190 ft2
0.1
Wood
10
Under Attic (Vented) NOOK
30
Blown
88 ft2
0.1
Wood
11
Under Attic (Vented) BEDROOM 2
30
Blown
139 ft2
0.1
Wood
12
Under Attic (Vented) CLST 2
30
Blown
16 ft2
0.1
Wood
13
Under Attic (Vented) CLST 3
30
Blown
1 B ft2
0.1
Wood
14
Under Attic (Vented) LAUNDRY
30
Blown
66 ft2
0.1
Wood
15
Under Attic (Vented) HALLWAY
30
Blown
65 ft2
0.1
Wood
16
Under Attic (Vented) M. TOILET
30
Blown
32 ft2
0.1
Wood
17
Under Attic (Vented) CLST 4
30
Blown
18 ft2
0.1
Wood
18
Under Attic (Vented) BEDROOM 4
30
Blown
129 ft2
0.1
Wood
19
Under Attic (Vented) BATH 3
30
Blown
66 ft2
0.1
Wood
20
Under Attic (Vented) BEDROOM 3
30
Blown
137 ft2
0.1
Wood
21
Under Attic (Vented) BATH
30
Blown
48 ft2
0.1
Wood
WALLS
Adjacent Cavity y
Width
Height
Sheathing Framing Solar
Below
1
S
Exterior Concrete Block - PolystyTER BE
9
9
0 9
1
81.8 ft2
0
0
0.6
0
2
W
Exterior Concrete Block - Polystyddt(STER BE
9
13
0 9
1
11 B.1 ft2
0
0
0.6
0
3
N
Exterior Concrete Block - PolystyhMTER BE
9
17
0 9
1
154.4 ft2
0
0
0.6
0
4
N
Exterior Concrete Block- Polystyrend/VIC 1
9
8
0 8
1
64.7 ft2
0
0
0.6
0
_ 5
E
Exterior Concrete Block - PolystyddA STER BA
9
8
0 8
1
64.7 ft2
0
0
0.6
0
_ 6
N
Exterior Concrete Block - PolystyftWTER BA
9
14
0 8
1
113.2 ft2
0
0
0.6
0
7
E
Exterior Concrete Block- Polystyrene DEN
9
12
0 10
1
121.0 ft2
0
0
0.6
0
8
N
Exterior Concrete Block - PolystyreneDEN
9
3
0 10
1
30.3 ft2
0
0
0.6
0
9
E
Exterior Concrete Block - Polystyren€DYER
9
8
0 10
1
80.7 ft2
0
0
0.6
0
10
E
Exterior Concrete Block - PolystytMNG ROO
9
11
0 10
1
110.9 ft2
0
0
0.6
0
11
W
Exterior Concrete Block - PolystyfM MILY ROO
9
16
0 10
1
161.3 ft2
0
0
0.6
0
_ 12
W
Exterior Concrete Block - Polystyren(NOOK
9
8
0 10
1
80.7 ft2
0
0
0.6
0
13
W
Exterior Concrete Block - PolystyREBROOM 2
9
11
0 8
1
88.9 ft2
0
0
0.6
0
_ 14
N
Exterior Concrete Block - PolystyRE®ROOM 2
9
9
0 8
1
72.8 ft2
0
0
0.6
0
15
W
Exterior Concrete Block - Polystyren6LST 3
9
2
0 8
1
16.2 ft2
0
0
0.6
0
_ 16
E
Exterior Concrete Block - PolystyrddeTOI LET
9
8
0 8
1
64.7 ft2
0
0
0.6
0
17
N
Exterior Concrete Block - PolystyrdMeTOILET
9
4
0 8
1
32.3 ft2
0
0
0.6
0
18
S
Exterior Concrete Block - PolysgMDROOM 4
9
11
0 8
1
88.9 ft2
0
0
0.6
0
19
S
Exterior Concrete Block - Polystyren@ATH 3
9
6
0 8
1
48.5 ft2
0
0
0.6
0
6/3/2021 4:23 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020
INPU I bUMMAKY UHt:UKLIb I
KhPUKI
WALLS
Adjacent
Space
Cavity Width
Et
Height
rea
Sheathing Framing
le
Solar
Below
_ 20
S
Exterior
Concrete Block - PolystyM§)ROOM 3
9 13 0
8
1
105.1 ft2
0
0
0.6
0
21
W
Exterior
Concrete Block - Polysty&EDROOM 3
9 11 0
8
1
88.9 ft2
0
0
0.6
0
22
S
Exterior
Concrete Block - Polystyrend3ATH
9 5 0
8
1
40.4 ft2
0
0
0.6
0
23
E
Garage
Frame - Wood LAUNDRY
11 21
8
1
169.8 ft2
0
0.25
0.600000
0
_ 24
S
Garage
Frame - Wood DINING R00
11 7
8
1
56.6 ft2
0
0.25
0.600000
0
DOORS
# Ornt Door Type
1 E Insulated
V
Wall
#
Omt
ID
Frame
Panes
1
W
2
Metal
Low-E Single
_ 2
N
3
Metal.
Low-E Single
3
N
6
Metal
Low-E Single
4
E
7
Metal
low-E Single
5
E
10
Metal
Low-E Single
6
W
11
Metal
Low-E Single
_ 7
W
12
Metal
Low-E Single
8
W
13
Metal
Low-E Single
9
E
16
Metal
Low-E Single
10
S
18
Metal
Low-E Single
11
S
19
Metal
Low-E Single
12
W
21
Metal
Low-E Single
_ 13
S
22
Metal
Low-E Single
# Floor Area Ceiling A
1 441 ft2 441 ft2
Space
rea
Storms
U-Value
FOYER
None
.23
WINDOWS
ntation shown is the entered, Proposed orientation.
NFRC
U-Factor SHGC
Imp
Area
Yes
0.63 0.25
N
20.0 ft2
Yes
0.63 0.25
N
12.0 ft2
Yes
0.67 0.23
N
12.0 ft2
Yes
0.67 0.23
N
15.0 ft2
Yes
0.67 0.23
N
15.0 ft2
Yes
0.63 0.25
N
60.3 ft2
Yes
0.63 0.25
N
15.0 ft2
Yes
0.63 0.25
N
15.0 ft2
Yes
0.63 0.25
N
4.0 ft2
Yes
0.63 0.25
N
15.0 ft2
Yes
0.63 0.25
N
6.0 ft2
Yes
0.63 0.25
N
15.0 ft2
Yes
0.63 0.25
N
6.0 ft2
GARAGE
Exposed Wall Perimeter
Avg. Wall
28 ft
8 ft
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA
1 Wholehouse ProposedACH(50) .000405 2327.4 127.69 239.72
Width
Ft In
6
Overhang
Depth Separatii
1 ft 0 in 1 ft 4 in
1 ft 0 in 1 ft 4 in
1 ft 0 in 1 ft 4 in
1ft0in 1ft4in
1ft0in 1ft4in
1ft0in 1ft4in
1 ft 0 in 1 ft 4 in
1ft0in 1ft4in
1 ft 0 in 1 ft 4 in
1ft0in 1ft4in
1 ft 0 in 1 ft 4 in
1 ft 0 in 1 ft 4 in
1 ft 0 in 1 ft 4 in
Height
Ft In
6 8
Int Shade
None
None
None
None
None
None
None
None
None
None
None
None
None
Height Exposed Wall Insulation
11
ACH ACH 50
1331 7
Area
40 ft2
None
None
None
None
None
None
None
None
None
None
None
None
None
6/3/2021 4:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7
FnRM R4ns-Pnpn INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat/
None
COP:1
27 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Single SEER: 16
35.2 kBtu/hr
1056 cfm
0.8
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0:98 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft2
DUCTS
---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT .
OUT QN
RLF
Heat Cool
1 Attic 6 150 ft2
Attic
15 ft2 Default Leakage
LAUNDRY
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan [[ ]] Feb ((j Mar
Heatin�7C� Jan [X] Feb [X] Mar
[ j Apr
[ ] Apr
] May [X] Jun [X] Jul
] May [ ] Jun [ ] Jul
X AugX]
Au[
Se
] Sep
[ ] Oct
[ ] Oct
Nov
Nov
Dec
Dec
Venting[[ ]] Jan [[ jj Feb [[XX]] Mar
[X] Apr
[ ]] May [ ] Jun [ l Jul
l
[ Aug
L
[ ] Se
[Xl Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 80
80 78 78
78
78
78
78
78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 80
80 78 78
78
78
78
78
78
78
Heating (WD) AM 65
65 65
65 65 65
65
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
68
68
Heating (WEH) AM 65
65 65
65 65 65
65
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 3
Default(8 lbs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(B Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(B Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
6/3/2021 4:23 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LINEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FAMILY RM
Default(8lbs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CABANA RM
Default(8lbs/sq.ft.
ft2
ft
0.3
CABANA WIC
Default(8 Ibs/s .ft.
ft2
ft
0.3
CABANA BATH
6/3/2021 4:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the EnergyPerformance Index, the more efficient the home.
6013 SPRUCE DRIVE, FORT PIERCE, FL,
1. New construction or epsting
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Polystyrene Bead AggrER=9.0
1828.20 ft2
b. Frame - Wood, Adjacent
R=11.0
226.33 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
11. Ceiling Type and insulation level
Insulation
Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0
2190.00 ft2
6. Conditioned floor area (ft2)
2190
b. N/A
R=
ft2
c. N/A
R=
ft2
7. Windows- Description
Area
12. Ducts, location & insulation level
R ft2
a. U Factor: Sgl, U=0.63
168.30 ft2
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
6 150
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.67
42.00 ft2
SHGC: SHGC=0.23
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
35.2
SEER:16.00
SHGC:
d. U-Factor: N/A
ft2
14. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
27.0
COP:1.00
Area Weighted Average Overhang Depth:
1.000 ft.
Area Weighted Average SHGC:
0.246
8. Skylights Description
Area
15. Hot water systems
C'
40 gallons
a. U-Factor(AVG): N/A
ft2
a. Electric
EF: 0.98
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
2190.00 ft2
Credits (Performance method)
None
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features_,--1
Builder Signature: - Dater
Address of New Home: I�®� 3 Sr�rt�c� City/FL
`Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/3/2021 4:23 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: DOTY AND BROWN RESIDENCE Builder Name: ASSOCIATED HOMES, INC.
Street: 6013 SPRUCE DRIVE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
U
Owner: JAMES DOTY AND RILEY BROWN Jurisdiction: ST LUCIE COUNTY
w
Design Location: FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind pipinci and wirin .
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub -floor, wall covering or ceiling
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or cellincls.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
6/3/2021 4:23 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1