Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 F ��� FLORIDA ENERGY IENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: DOTY AND BROWN RESIDENCE Builder Name: ASSOCIATED HOMES, INC. Street: 6013 SPRUCE DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: JAMES DOTY AND RILEY BROWN Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or epsting New (From Plans) 10. Wall Types(2054.6 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Polystyrene Bead Aggr93=9.0 1828.20 ft2 b. Frame - Wood, Adjacent R=11.0 226.33 ft2 3. Number of units, if multiple family - 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11. Ceiling Types (2190.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2190.00 ft2 6. Conditioned floor area above grade (ft2) 2190 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(210.3 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: LAUNDRY R ft2 6 150 a. U-Factor: Sgl, U=0.63 168.30 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.67 42.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.23 a. Central Unit 35.2 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.246 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (2190.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2190.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Total Proposed Modified Loads: 62.11 Glass/Floor Area: 0.096 PASS Total Baseline Loads: 66.61 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this S' _ Code. calculation indicates compliance y� �I;, ' _ .�VIA. ' n�y hhkt- with the Florida Energy Code. y �...f PREPARED BY: lJrl DATE: 6-7-2021 Before construction is completed this building will be inspected for compliance with Section 553.908 a I hereby certify that this building, as designed, is in compliance Florida Statutes.0 with the Florida Energy Cod OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation'Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/3/2021 4:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: DOTY AND BROWN RESIDE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2190 Lot # Owner Name: JAMES DOTY AND RILEY BR Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: ASSOCIATED HOMES, INC. Rotate Angle: 0 Street: 6013 SPRUCE DRIVE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: SEDONA VISTA 4/3- GARAGE LEFT CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range . FL, Fort Pierce Fl.VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2190 19949 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 218 1983.8 No 0 1 1 Yes Yes Yes 2 WIC 1 32 259.2 No 0 1 Yes Yes Yes 3 WIC 2 36 291.6 No 0 1 No Yes Yes 4 MASTER BATH 174 1409.4 No 0 1 Yes Yes Yes 5 DEN 151 1525.1 No 0 1 Yes Yes Yes 6 FOYER 104 1050.4 No 0 1 Yes Yes Yes 7 DINING ROOM 143 1444.3 No 0 1 Yes Yes Yes 8 FAMILY ROOM 320 3232 No 0 1 Yes Yes Yes 9 KITCHEN 190 1919 Yes 0 1 No Yes Yes 10 NOOK 88 888.8 No 0 1 Yes Yes Yes 11 BEDROOM 2 139 1125.9 No 0 1 1 Yes Yes Yes 12 CLST 2 16 129.6 No 0 1 No Yes Yes 13 CLST 3 18 145.8 No 0 1 Yes Yes Yes 14 LAUNDRY 66 534.6 No 0 1 No Yes Yes 15 HALLWAY 65 526.5 No 0 1 No Yes Yes 16 M. TOILET 32 259.2 No 0 1 Yes Yes Yes 17 CLST 4 18 145.8 No 0 1 No Yes Yes 18 BEDROOM 4 129 1044.9 No 0 1 1 Yes Yes Yes 19 BATH 3 66 534.6 No 0 1 Yes Yes Yes 20 BEDROOM 3 137 1109.7 No 0 1 1 Yes Yes Yes 21 BATH 48 388.8 No 0 1 Yes Yes Yes 6/3/2021 4:23 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 39 ft 0 218 ft2 ___- 0 1 0 2 Slab -On -Grade Edge Insulation WIC 1 8 ft 0 32 ft2 -- - 0 1 0 3 Slab -On -Grade Edge Insulation WIC 2 1 ft 0 36 ft2 ____ 0 1 0 4 Slab -On -Grade Edge Insulation MASTER BATH 22 ft 0 174 ft2 ____ 0 1 0 5 Slab -On -Grade Edge Insulation DEN 15 ft 0 151 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulation FOYER 8 ft 0 104 ft2 _-__ 0 1 0 7 Slab -On -Grade Edge Insulation DINING ROOM 11 ft 0 143 ft2 0 1 0 8 Slab -On -Grade Edge Insulation FAMILY ROOM 16 ft 0 320 ft2 _-__ 0 1 0 9 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 190 ft2 __-_ 0 1 0 10SIab-On-Grade Edge Insulation NOOK 8 ft 0 88 ft2 ____ 0 1 0 11SIab-On-Grade Edge Insulation BEDROOM 2 19.9 ft 0 139 ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulation CLST 2 1 ft 0 16 ft2 ___- 0 1 0 13SIab-On-Grade Edge Insulation CLST 3 2 ft 0 18 ft2 ___- 0 1 0 14SIab-On-Grade Edge Insulation LAUNDRY 1 ft 0 66 ft2 ___- 0 1 0 15SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 65 ft2 ____ 0 1 0 16SIab-On-Grade Edge Insulation M. TOILET 12 ft 0 32 ft2 __-_ 0 1 0 17SIab-On-Grade Edge Insulation CLST 4 1 ft 0 18 ft2 -___ 0 1 0 18SIab-On-Grade Edge Insulation BEDROOM 4 11 ft 0 129 ft2 ____ 0 1 0 19SIab-On-Grade Edge Insulation BATH 3 6 ft 0 66 ft2 ---- 0 1 0 20SIab-On-Grade Edge Insulation BEDROOM 3 24 ft 0 137 ft2 ____ 0 1 0 21SIab-On-Grade Edge Insulation BATH 5 ft 0 48 ft2 ---- 0 1 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2449 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 26.57 ATTIC RBS IRCC V # Type Ventilation Vent Ratio (1 in) Area 1 Full attic Vented 300 2190 ft2 N N 6/3/2021 4:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY GFIEGKL.IST REPURT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 218 ft2 0.1 Wood 2 Under Attic (Vented) WIC 1 30 Blown 32 ft2 0.1 Wood 3 Under Attic (Vented) WIC 2 30 Blown 36 ft2 0.1 Wood 4 Under Attic (Vented) MASTER BATH 30 Blown 174 ft2 0.1 Wood 5 Under Attic (Vented) DEN 30 Blown 151ft2 0.1 Wood 6 Under Attic (Vented) FOYER 30 Blown 104 ft2 0.1 Wood 7 Under Attic (Vented) DINING ROOM 30 Blown 143 ft2 0.1 Wood 8 Under Attic (Vented) FAMILY ROOM 30 Blown 320 ft2 0.1 Wood 9 Under Attic (Vented) KITCHEN 30 Blown 190 ft2 0.1 Wood 10 Under Attic (Vented) NOOK 30 Blown 88 ft2 0.1 Wood 11 Under Attic (Vented) BEDROOM 2 30 Blown 139 ft2 0.1 Wood 12 Under Attic (Vented) CLST 2 30 Blown 16 ft2 0.1 Wood 13 Under Attic (Vented) CLST 3 30 Blown 1 B ft2 0.1 Wood 14 Under Attic (Vented) LAUNDRY 30 Blown 66 ft2 0.1 Wood 15 Under Attic (Vented) HALLWAY 30 Blown 65 ft2 0.1 Wood 16 Under Attic (Vented) M. TOILET 30 Blown 32 ft2 0.1 Wood 17 Under Attic (Vented) CLST 4 30 Blown 18 ft2 0.1 Wood 18 Under Attic (Vented) BEDROOM 4 30 Blown 129 ft2 0.1 Wood 19 Under Attic (Vented) BATH 3 30 Blown 66 ft2 0.1 Wood 20 Under Attic (Vented) BEDROOM 3 30 Blown 137 ft2 0.1 Wood 21 Under Attic (Vented) BATH 30 Blown 48 ft2 0.1 Wood WALLS Adjacent Cavity y Width Height Sheathing Framing Solar Below 1 S Exterior Concrete Block - PolystyTER BE 9 9 0 9 1 81.8 ft2 0 0 0.6 0 2 W Exterior Concrete Block - Polystyddt(STER BE 9 13 0 9 1 11 B.1 ft2 0 0 0.6 0 3 N Exterior Concrete Block - PolystyhMTER BE 9 17 0 9 1 154.4 ft2 0 0 0.6 0 4 N Exterior Concrete Block- Polystyrend/VIC 1 9 8 0 8 1 64.7 ft2 0 0 0.6 0 _ 5 E Exterior Concrete Block - PolystyddA STER BA 9 8 0 8 1 64.7 ft2 0 0 0.6 0 _ 6 N Exterior Concrete Block - PolystyftWTER BA 9 14 0 8 1 113.2 ft2 0 0 0.6 0 7 E Exterior Concrete Block- Polystyrene DEN 9 12 0 10 1 121.0 ft2 0 0 0.6 0 8 N Exterior Concrete Block - PolystyreneDEN 9 3 0 10 1 30.3 ft2 0 0 0.6 0 9 E Exterior Concrete Block - Polystyren€DYER 9 8 0 10 1 80.7 ft2 0 0 0.6 0 10 E Exterior Concrete Block - PolystytMNG ROO 9 11 0 10 1 110.9 ft2 0 0 0.6 0 11 W Exterior Concrete Block - PolystyfM MILY ROO 9 16 0 10 1 161.3 ft2 0 0 0.6 0 _ 12 W Exterior Concrete Block - Polystyren(NOOK 9 8 0 10 1 80.7 ft2 0 0 0.6 0 13 W Exterior Concrete Block - PolystyREBROOM 2 9 11 0 8 1 88.9 ft2 0 0 0.6 0 _ 14 N Exterior Concrete Block - PolystyRE®ROOM 2 9 9 0 8 1 72.8 ft2 0 0 0.6 0 15 W Exterior Concrete Block - Polystyren6LST 3 9 2 0 8 1 16.2 ft2 0 0 0.6 0 _ 16 E Exterior Concrete Block - PolystyrddeTOI LET 9 8 0 8 1 64.7 ft2 0 0 0.6 0 17 N Exterior Concrete Block - PolystyrdMeTOILET 9 4 0 8 1 32.3 ft2 0 0 0.6 0 18 S Exterior Concrete Block - PolysgMDROOM 4 9 11 0 8 1 88.9 ft2 0 0 0.6 0 19 S Exterior Concrete Block - Polystyren@ATH 3 9 6 0 8 1 48.5 ft2 0 0 0.6 0 6/3/2021 4:23 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPU I bUMMAKY UHt:UKLIb I KhPUKI WALLS Adjacent Space Cavity Width Et Height rea Sheathing Framing le Solar Below _ 20 S Exterior Concrete Block - PolystyM§)ROOM 3 9 13 0 8 1 105.1 ft2 0 0 0.6 0 21 W Exterior Concrete Block - Polysty&EDROOM 3 9 11 0 8 1 88.9 ft2 0 0 0.6 0 22 S Exterior Concrete Block - Polystyrend3ATH 9 5 0 8 1 40.4 ft2 0 0 0.6 0 23 E Garage Frame - Wood LAUNDRY 11 21 8 1 169.8 ft2 0 0.25 0.600000 0 _ 24 S Garage Frame - Wood DINING R00 11 7 8 1 56.6 ft2 0 0.25 0.600000 0 DOORS # Ornt Door Type 1 E Insulated V Wall # Omt ID Frame Panes 1 W 2 Metal Low-E Single _ 2 N 3 Metal. Low-E Single 3 N 6 Metal Low-E Single 4 E 7 Metal low-E Single 5 E 10 Metal Low-E Single 6 W 11 Metal Low-E Single _ 7 W 12 Metal Low-E Single 8 W 13 Metal Low-E Single 9 E 16 Metal Low-E Single 10 S 18 Metal Low-E Single 11 S 19 Metal Low-E Single 12 W 21 Metal Low-E Single _ 13 S 22 Metal Low-E Single # Floor Area Ceiling A 1 441 ft2 441 ft2 Space rea Storms U-Value FOYER None .23 WINDOWS ntation shown is the entered, Proposed orientation. NFRC U-Factor SHGC Imp Area Yes 0.63 0.25 N 20.0 ft2 Yes 0.63 0.25 N 12.0 ft2 Yes 0.67 0.23 N 12.0 ft2 Yes 0.67 0.23 N 15.0 ft2 Yes 0.67 0.23 N 15.0 ft2 Yes 0.63 0.25 N 60.3 ft2 Yes 0.63 0.25 N 15.0 ft2 Yes 0.63 0.25 N 15.0 ft2 Yes 0.63 0.25 N 4.0 ft2 Yes 0.63 0.25 N 15.0 ft2 Yes 0.63 0.25 N 6.0 ft2 Yes 0.63 0.25 N 15.0 ft2 Yes 0.63 0.25 N 6.0 ft2 GARAGE Exposed Wall Perimeter Avg. Wall 28 ft 8 ft INFILTRATION # Scope Method SLA CFM 50 ELA EgLA 1 Wholehouse ProposedACH(50) .000405 2327.4 127.69 239.72 Width Ft In 6 Overhang Depth Separatii 1 ft 0 in 1 ft 4 in 1 ft 0 in 1 ft 4 in 1 ft 0 in 1 ft 4 in 1ft0in 1ft4in 1ft0in 1ft4in 1ft0in 1ft4in 1 ft 0 in 1 ft 4 in 1ft0in 1ft4in 1 ft 0 in 1 ft 4 in 1ft0in 1ft4in 1 ft 0 in 1 ft 4 in 1 ft 0 in 1 ft 4 in 1 ft 0 in 1 ft 4 in Height Ft In 6 8 Int Shade None None None None None None None None None None None None None Height Exposed Wall Insulation 11 ACH ACH 50 1331 7 Area 40 ft2 None None None None None None None None None None None None None 6/3/2021 4:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 FnRM R4ns-Pnpn INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 35.2 kBtu/hr 1056 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0:98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT . OUT QN RLF Heat Cool 1 Attic 6 150 ft2 Attic 15 ft2 Default Leakage LAUNDRY (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan [[ ]] Feb ((j Mar Heatin�7C� Jan [X] Feb [X] Mar [ j Apr [ ] Apr ] May [X] Jun [X] Jul ] May [ ] Jun [ ] Jul X AugX] Au[ Se ] Sep [ ] Oct [ ] Oct Nov Nov Dec Dec Venting[[ ]] Jan [[ jj Feb [[XX]] Mar [X] Apr [ ]] May [ ] Jun [ l Jul l [ Aug L [ ] Se [Xl Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(B Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(B Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO 6/3/2021 4:23 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 LINEN Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 FAMILY RM Default(8lbs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 CABANA RM Default(8lbs/sq.ft. ft2 ft 0.3 CABANA WIC Default(8 Ibs/s .ft. ft2 ft 0.3 CABANA BATH 6/3/2021 4:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the EnergyPerformance Index, the more efficient the home. 6013 SPRUCE DRIVE, FORT PIERCE, FL, 1. New construction or epsting New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Polystyrene Bead AggrER=9.0 1828.20 ft2 b. Frame - Wood, Adjacent R=11.0 226.33 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2190.00 ft2 6. Conditioned floor area (ft2) 2190 b. N/A R= ft2 c. N/A R= ft2 7. Windows- Description Area 12. Ducts, location & insulation level R ft2 a. U Factor: Sgl, U=0.63 168.30 ft2 a. Sup: Attic, Ret: Attic, AH: LAUNDRY 6 150 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.67 42.00 ft2 SHGC: SHGC=0.23 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 35.2 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.246 8. Skylights Description Area 15. Hot water systems C' 40 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF: 0.98 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2190.00 ft2 Credits (Performance method) None b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features_,--1 Builder Signature: - Dater Address of New Home: I�®� 3 Sr�rt�c� City/FL `Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/3/2021 4:23 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: DOTY AND BROWN RESIDENCE Builder Name: ASSOCIATED HOMES, INC. Street: 6013 SPRUCE DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner: JAMES DOTY AND RILEY BROWN Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pipinci and wirin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or cellincls. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/3/2021 4:23 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1