HomeMy WebLinkAboutFloor PlanFloor Plan scale: 1/4" = 11"i FIBERGLASS SHINGLES PEEL & STICK UNDERLAYMENT OVER 19/32" C.D.X. PLYWD. ALUM. DRIP EDGE ON 2 x 6 P.T. FASCIA WRAP WITH ALUM.—,. VINYL VENTED PROVIDE "CASTCRETE" PRECAST LINTELS ABOVI ALL OPENINGS 6411VIKKOR a I i'll I W 05 500,04 R30 BLOWN INSULATION Scope of' Work ABOVE LIVING AREAS "1-1/2" CLNG. 1 x 4 P.T. BOARD FIRIESTOP \_(1) COURSE BEAM BLOCK WITH (1) REBAR AND FILLED WITH GROUT 8 x 16 x 8 C.M.U. WITH #5 VERT, DOWEL IN GROUT FILLED CELLS R9 CORE FILLED INSUL. AT LIVING AREA FIRESTOP 2500# CONC. FOOTING WITH (2) #5 RE13AR GRADE --*Jmin. I L 4" 251 FIBERMIX CONC. OVER . 6 VAPOR BARRIER SEE FOOTING ON L"AN, COMPACTED, DETAILS TERMITIL-E. TREATED FILL Typical Wall Sect -ion scale: 3/4f = 1'-0®' WINDOW SCHEDULE MI NON —IMPACT WINDOWS LOW—E MARK M.O. SIZE TYPE REMARKS 25 s. h. 37 3/4" x 63" Singlehung o n gressmpac H32 27 1/4" x 26" _ Singlehung Non Impact 35 54' x 63" Singlehung o n I Pgressmpact 36" x 16" _ Fix. Glass 37 3/4" x 17" Fixed Glass Non Impact Transom 36" x 16" Tempered Fix. Glass 37 314" x 17" Fixed Glass Obscure Transom Non Impact 24 37 3/4 x 50 5/8" Singlehung Temp. Glass Non pact All windows to have white frames, colonial grilles (see elevations) Clear, Low E NON —IMPACT 0 Exterior Doors [:] interior Doors Size Type (D Double 3080 FG Smooth Finish with Dead Bolt 6 Panel 116' x 7' Overhead Steel 9058 Sliding Glass Door 7 2868 Masonite style S.C. with weatherstrip & Threshold 2668 Masonite style H.C. 2868 Masonite style H.C. 1 4068 Masonite style H.C. Bifold 11 2068 Masonite style H.C. 12 6068 Masonite style H.C. Bifold 13 2668 Masonite style H.C. 14 2568 Masonite style H.C. Bifold 15 6068 Masonite style H.C.Bipass 16 1 (2) 3068 FD Single Light Insert 17 , 2568 Masonite style H.C. Bifold H 2668 Masonite style H.C. Bifold C 40 C 0 M 0 U) 0 Q) �; .2> CD a) �Q > CL C 0 .h- 0- CL > LU < 0 U_ M 0 cn :Single level CBS single family residence Buildin(,.'Ode ' 2020 Florida Building Code: Residentia 2017 Natio,ial Electric Code Deli n L io 13 d s Roof Live Load: 20.0 p.s.f. Floor Live Load: N. A. Wind SpeE,d: 161'D MPH (3 second gusts) Wind Importance Factor: 1.0 Building Catecior -y: 11 , Wind Expcl-,sure: B Internal Pressure Coefficent: .18 Structure [)esl�qnecl: Enclosed Soil bearin,j capacity: 2000 p.s.f. f"N Cast in Place Sill or Tie -a, Op Optior In the event that the precast products are clarnaged in the field cast in place sills and tie beams may be used (not to exceed 5' — 10"i TVDical cost in place tie bearri to be a min. 8 x 12 with two W-5 top and two #5 bottom. Safe Load Table Notes Installation Notes 1. All volucs based on minimum 4" nominal bearing. Exception: Safe loads for unfilled U lintels must 1. Inst9liation of U lintels must comply with architectural arid/ 1 or structural drawings. be 6 1 24uc:ed by 20% if bearing length is less than 2. U lintels can be field cut to the required length. 2. N.R. Not Rated 3. Caf��!: in, place concrete may bero provided In composite 3. Safe lauds are superimposed allowable loads. III Inte In lieu of concrete masonry units, 4. One #7 rebar mu be substituted for two #5 rebor in 8 inch linitels 4. They exterior surface of U lintels installed in exterior concrete masonry walls shall have a coating of stucco in ASTM C-926 only. 5. All safe loads In units of pounds per linter foot. applied accordance with or other approved coating. 6. All safe loads are based on simply supported span. 5. Concrete masoniry units used In composite U lintel shall be ald In a running bond. 7. Safe lot ' ratingsbased on rational design analysis 6. Shtpre composite lintels as required. per AD 318 and In ACI 530. 7. U IiIntelS are manufactured with a 5 1/2" long notch at bol:h ends to accomodate vertical cell reinforcing and grvut. NOR" A �' 8F1 6-1 B/1 T --A raw I . 1W / 5/8 Lintelype Designation Cost Crete Lintel Schedule Cornposite U Lintel Materials 1. Graiut per ASTM C476 fg=3000 pal with maximum 3/8 inch aggregate and 8 to 11 inch slump. 2. Rebar per ASTM A615 Grade 60 3. Concrete masonry units (CMU) per ASTM C90 with minimum net area compressive strength = 1900 psi 4. Mortar per ASTM C270 Type M or S ,All Rebar to be #5 Grade 60 min. MARK LENGTH OF LINTEL ALLOWABLE GRAVITY LOAD APPLIED GRAMTY LOAD ALLOWABLE UPLIFT LOAD APPLIED UIIUFr LOAD BEAM SPECS. 6113 11273 2707' 590 BF1 6 1 T/1 8 L-2 W-15" 1366 864 916 231 BF1 6 1T/1B L-3 5'- 1 10" 4360 1325 2080 628 8F16 1T/1B L-4 3'-6" 6113 150 3524 47 BF1 6 1T/113 L-5 4®-6" 6113 200 2707 610 BF16 1T/1B L-6 7'-6- 574,3 200 2166 60 BRF22 1T/113 L-7 61-6. 8360 268 2790 226 8F24 1T/1B L-8 10'- 6" 2781 150 146'1 47 BF24 IT/113 17'-4" 950 200 4-05 BID 8F1 6 1T/1B Min. Beam d!yiths shown, beams may be increased wiffii7mt cement At urg els 30 deep or larger, provide (1) #5 vertical rebar at 24 o.c. along length of lintel Cv o C: 0 as CO CN Ln CD (D c is > ® C3 X > Z V4 V1 C Z UJ C'q C-J oCC LL_ 0 Z APIAALU C, ci 00 T N C= car,(D Cn EU � CUO) .2 M _V = UL C\J U 4� C 0 4� CD 00 • rw yl 0- to E -L)VVD