HomeMy WebLinkAboutBuilding PlansNEW OUTWARD OPENING SCREEN -----
DOOR SELF CLOSING WITH A SELF
LATCHING AND LOCKING DEVICE
PLACED NO LESS THAN 54" FROM THE
BOTTOM OF THE SCREEN DOOR
LINE OF NEW SCREEN
ENCLOSURE
tl
f
LINE OF NEW SCREEN
ENCLOSURE
NEW SCREEN ENCLOSURE
UNDER SEPARATE PERMIT
LINE OF NEW SCREEN
ENCLOSURE
EDGE OF SLAB
(TYP.) 7'-1011
ELEV -11"
8" TYP. _
LINE OF NEW SCREEN
ENCLOSURE
ELEV -29"
SET BOTTOM OF NEW SPA SLAB ON -
TOP OF EX. FOOTING. FIELD ADJUST NEW SPA
DIMENSIONS AS REQUIRED.
YP. oCL
BENCH 3 SIDES
EX. STEM WALL
FOOTING
EXISTING REAR PORCH
73
t
t
i
i
EXISTING SLIDING GLASS DOOR TO BE= EQUIPPED WITH AN —
AUDIBLE ALARM THAT WILL SOUND WHEN DOOR OR
€ SCREEN IS OPENED. ALARM SHOULD MEET THE
REQUIREMENTS OF UL 2017 GENERAL PURPOSE SIGNALING
DEVICES & SYSTEMS SECTION 77. AND HAVE THE
FOLLOWING FEATURES.
1. ALARM TO LAST FOR A MINIMUM OF 30 SECONDS
2. ALARM TO BE A MINIMUM OF 85 DB
3. ALARM TO BE DISTINCT FROM ALL OTHER HOUSE
SOUNDS
4. ALARM TO HAVE AUTO RESET OF UP TO 15 SECONDS AND
6 --DEACT.IVAUCN SML.ITCF YPAD-OR M"UALLDCATED A—
E MINIMUM OF 54' ABOVE THE THRESHOLD
EXISTING GARAGE
ELEV -4" l
EX. STEM WALL
FOOTING
c
s
/
SPILL WAY
B
A-2
LINE OF NEW SCREEN
ENCLOSURE
Llf -1
N
1
N
EDGE OF SLAB
(TYP.)
WALL TO ALIGN W/
DRAINAGE EASEMENT
LINE
cq /
ELEV -57"
CONCRETE WALL (TYP.)
NEW POOL
CONCRETE
STAIR
7'-811
ELEV -13"
I
I NEW POOL
I
I
LINE OF NEW SCREEN —
ENCLOSURE
I
I
ELEV -13"
ELEV -4"
I
Ff-
10'-6" +/- 7'-611
CONCRETE I INEW POOL DECK
ELEV -57" 'MALL (TYP.)
ELEV -4"
EDGE OF SLAB
NEW POOL DECK (TYP.) I
NEW DRAIN I
ELEV -5"
EXISTING SLIDING GLASS DOOR TO BE EQUIPPED WITH AN
AUDIBLE ALARM THAT WILL SOUND WHEN DOOR OR
SCREEN IS OPENED. ALARM SHOULD MEET THE
REQUIREMENTS OF UL 2017 GENERAL PURPOSE SIGNALING
DEVICES & SYSTEMS SECTION 77. AND HAVE THE
FOLLOWING FEATURES.
1 ALARM TO LAST FOR A MINIMUM OF 30 SECONDS
2 ALARM TO BE A MINIMUM OF 85 DB
3 ALARM TO BE DISTINCT FROM ALL OTHER HOUSE SOUNDS
4 ALARM TO HAVE AUTO RESET OF UP TO 15 SECONDS AND
A DEACTIVATION SWITCH, KEYPAD OR MANUAL LOCATED A
MINIMUM OF 54' ABOVE THE THRESHOLD
POOL PLAN
"'=1' SCALE
EXISTING STORAGE
NEW 4" CONCRETE SLAB
W/ 6X6/W1.4xl.4 WWF
CENTERED ON
COMPACTED SUBGRADE.
COORDINATE SIZE WITH
EQUIPMENT.
LINE OF NEW SCREEN
ENCLOSURE
EDGE OF SLAB
(TYP.)
I
I
I
811 91
TYP. m
I
IrA
I A-2
CONCRETE
WALL (TYP.)
DOWEL NEW TO EXISTING W/
--- #3xl'-0" LNG. DOWELS
EPDXIED 6" INTO EXISTING
SPA. @ V-4" O.C.
FILTER
PUMP
PROPANE POOL
HEATER
REVIEWED FOR
CODE COMPLIANCE
ST. L UCIE COUNTY
DOCC
7
z
0
a
U
w
I
1
1
1
1
w
0
I
I
1
I
I
z
0
LA
1�1
>
1
I
1
1
1
w
uj
U
W
�
—�
LU
C
W
�
W
P-4
O
_j
oC
z
�-
L.LI.
<
V l
ui
a
aa0
LL!
I..L.
Ln
l0
r n�
V
DATE
DESIGNED
GMW
08-12-21
DRAWN
GMW
08-12-21
CHECKED
JOB NO.
2021-250
Aml
EX.
a
r
rP�
r.
#5 EACH WAY SPACED
@8"O.C.
SLAB LINE OF RESIDENCE EL. 0'-0"
"v
SLAB LINE OF RESIDENCE EL. 0'-0"
0)
EL. +1'-0”
0
TI � aY
•
rr _
,
4" o SPA
r�
M
Vu
4"
STANDARD HOOK b #5 EACH WAY 4
(TYP.) J4 SPACED @ 8" O.C.
#5 EACH WAY SPACED POOL
STANDARD HOOK°
@ 8" O.C. � .
(TYP.) b•
411
11'1
1
1-1
,�
EX COLUMN
(TYP.)
#5 EACH WAY
SPACED @ 8"
O.C.
EX SLAB
6" PVC 6" PVC / 4_ STANDARD HOOK
WATERSTOP PLASTER WATERSTOP ° 1'-0�� 8�� 8��
\ \ \ (TYP.) FINISH TYP. (TYP.) _ _ _ ..___ _....._ _._..___ . __.._ _____ . _ .... _.__ .__ . __ __.� _._ __.__ __._ _ .__ __. __._ _.._
#5 EACH WAY SPACED (TYP.) ° T� �J �� �,� __...._..
° / / j�
@ 8 O.C. ° /� / /� �. / '•,.. \ `�
b • ^ ,....l. ..� ... l..�- • ...... �t... J. .._.. •�A _. _.r. ,..si .�. _ ear--- —�. -- a-...... • l.... a,L" e,.... l.... ..... �.,. a _..... ... • . a. ........ ® \\ \ \ \�
ti � � ,\\ \
\ � � � SET BOTTOM OF NEW
K °" S A� V A V \ \ \ \ \ A V \ \ 'O��.� ``` SPA SLAB ON TOP OF
8 ��-) ' . ` /" ,F` ` EX. FOOTING. FIELD
ADJUST DIMENSIONS
AS REQUIRED.
_ SECTION A
4"=1' SCALE
SECTION B
4"=1' SCALE
�.
a
1r
.'1 W
e � �
Ln
#5 EACH WAY SPACED
@8"O.C.
Q,I
SLAB LINE OF RESIDENCE EL. 0'-0"
°
AIL; - 4"
e °
O re) <6 c .
U
n
1'-6" 8" 1'-6"
EX.
FOOTING
4" MIN. CONCRETE SLAB
W/ 6X6/W1.4X1.4 WWF
CENTERED
5 SPA. @ V-0" O.C.
4)-#5
SECTION C
4"=1' SCALE
EX. STEM
WALL
REVIEWED O.
CODE COMPLIANCE
COUNTYST. LUCIE
.. *.
„s SUMMIT
DESIGN & FORENSICS, INC.
725 SE PORT SAINT LUCIE BLVD.
SUITE 203
PORT SAINT LUCIE FL 34984
(772) 285-0572
BRIAN 1. MASKOL
FL PE #66080
z
0
L
of
U
w
w
Q
0
z
0
w
i
IlLLJ
W
w�
C)
j._q
way
U
J
I.L
z�
C)�Qu')
w�
w
CL
�O
V
z
O
U
Lu
(n
DATE
DESIGNED
GMW
08-12-21
DRAWN
GMW
08-12-21
CHECKED
JOB NO.
2021-250
Am2
�", SUMMIT
DESIGN &FORENSICS, INC.
`*0. •:
EXISTING CONCRETE
FOOTING
UNDERPIN EXISTING —
FOOTING TO BOTTOM OF
POOL SLAB
ouoflr •0
1"=1' SCALE
#5 DOWEL X 1'-0" LONG
EPDXIED 6" INTO EXISTING
PORCH SLAB SPACED @ 1'-0"
O.C.
EXISTING MASONRY STEM WALL
NOTE: STAIR NOT SHOWN.
00
-•
THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE 2020
FLORIDA BUILDING CODE RESIDENTIAL ALONG WITH AMENDMENTS. MATERIALS
AND SERVICES PROVIDED BY THE CONTRACTOR SHALL CONFORM TO THE ABOVE
MENTIONED CODES AND THE CONTRACT SPECIFICATIONS.
ELECTRICAL SHALL CONFORM TO THE 2017 NEC.
THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE JOB
CONDITIONS AND RESTRICTIONS.
INSTALL ALL PRODUCTS PER MANUFACTURER'S RECOMMENDATIONS AND
SPECIFICATIONS.
7a .T ftyu TK+Z
WIND LOADS:
ULTIMATE WIND SPEED, 3 SECOND GUST: 160 MPH
BUILDING CATEGORY: II
EXPOSURE CATEGORY: D
INTERNAL PRESSURE COEFFICIENT: +/-0.1
FLOOR LOADS:
FLOOD ZONE AE
BASE FLOOR ELEVATION 5'
FOUNDATIONS:
FOUNDATIONS, SLAB AND SITE PREPARATION SHALL SHALL CONFORM TO THE
RECOMMENDATIONS OF A RETAINED GEO TECHNICAL ENGINEER LICENSED IN
FLORIDA.
THE CONTRACTOR SHALL EXERCISE GREAT CARE DURING EXCAVATION.
UNDERGROUND UTILITY LOCATIONS ARE UNKNOWN. THE CONTRACTOR SHALL
PREDETERMINE UTILITY LOCATIONS AND NOTIFY THE ENGINEER IMMEDIATELY IF
A CONFLICT EXISTS. THE CONTRACTOR IS RESPONSIBLE FOR THE SAFE
SUPPORT OF UTILITIES ACROSS EXCAVATIONS.
PRIORA SOILS REPORT WAS NOT AVAT
LLABLE DURING TH1z- DESIGN OF THE
FOUNDATIONS FOR THE SUBJECT STRUCTUREw FOUNDATION DESIGN HAS BEEN
PREPARED USING AN ASSUMED ALLOWABLE BEARING PRESSURE OF 2,500 PSF.
CONSTRUCTION . GEOTECHNICAL ENGINEER SHALL
PROVIDEASSUMPTION, PERFORM COMPACTION TESTING, MAKE SLAB AND SITE
RECOMMENDATIONS AND PROVIDE A SIGNED AND SEALED COMPLIANCE LETTER
STATING THE SITE SOILS WILL , MINIMUM BEARINGPRESSURE
!f PSF.
CONCRETE:
CONCRETE SHALL CONFORM TO ACI SPECIFICATIONS, LATEST EDITION.
REINFORCING SHALL CONFORM TO CRSI, LATEST EDITION.
CAST -IN -PLACE CONCRETE SHALL DEVELOP A MINIMUM 28 DAY COMPRESSIVE
STRENGTH OF 4,000 PSI.
REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60.
ALL REINFORCING BAR SPLICE LENGTHS SHALL BE CALCULATED IN ACCORDANCE
WITH ACI UNLESS NOTED OTHERWISE. SPLICES SHALL BE CLASS "B" AS DEFINED
BY ACI UNLESS NOTED OTHERWISE.
AEVIEWED FOR
r pCOMPLIANCE
725 SE PORT SAINT LUCIE BLVD.
SUITE 203
PORT SAINT LUCIE FL 34984
(772) 285-0572
BRIAN J. MASKOL
FL PE #66080
i
U]
i
z
0
w
o
v
cf)
w
Q
w
z
�
a
w
c.7
z
6
wl
cv
G1
co
cv
z
0
4�
N
w
i
a
•
DA'I'L
DESIGNED
GMW
08-12-21
DRAWN
GMW
08 -12- 21
CHECKED
JOB NO.
2021-25
3178 Living S.F. at 3 VA
9534
VA
Electrical Load
Calculations
(2) Two 20 Amp Appliance Ckts.
3000
VA
Laundry
1500
VA
Sub Panel
Dryer
Dishwasher
5000
1200
VA
VA
Pool Pump
p
2000 VA
Oven
5,000
VA
Propane Pool Heater 200 VA
Cook Top
8,000
VA
Pool Lighting
600 VA
Disposal
800
VA
Landscape Lighting
1000 VA
Microwave
1600
VA
Total
3,800 VA
Garage Door Opener
900
VA
Garage Door Opener
900
VA
3,800 VA / 240
V = 16 Amps
Ref. Circuit
Water Heater
1200 VA
5500 VA
NEW 40 Amp
Sub —Panel
Total 44,134 VA
First 10 KVA at 100% 10,000 VA
Remainder at 40% 13,654 VA
Total
AC Heat at 100%
Tota
42,954 VA / 240 V = 179 Amps
ELECTRICAL LEGEND
23,654 VA
19,300 VA
43,911 VA
WATERPROOF RECESSED POOL LIGHT AND LENS
SWITCH
W�GFI WEATHER PROOF GROUND FAULT
$� D!SCCNNECT
Pool
Heater
Main Panel 42,954 VA / 240 V = 179 Amps
Sub Panel 3,800 VA / 240 V = 16 Amps
Total Load Requirements 195 Amps
400 Amp Existing Service
Electrical contractor to verify all equipment loads prior to
start of construction. Electrical contractor to recalculate
electrical schedule if loads are to be modified
service
D amp meter
in combo
ground copper
�LIC uuna wire
to noting rebars
Electrical Riser Diagram
,,�, SUMMIT
DESIGN & FORENSICS, INC.
725 SE PORT SAINT LUCIE BLVD.
SUITE 203
PORT SAINT LUCIE FL 34984
(772) 285-0572
z
O
a
U
Ln
w
w
Q
0
z
O
in
>
w
W
W
U
—�
``'
z
W�
0
�--
w
�U
way
J
a�
z�
oC
'�
Cn
W
Cl'
�
w
�a
0
�10a
�
V
Z
Q
J
Q
U
U
W
I
W
J
0
0
r
DATE
DESIGNED
GMW
08-12-21
DRAWN
GMW
08-12-21
CHECKED
JOB NO.
2021-250
E-1
SPA
JET
SPA
POOL
JET
SPA
DRAIN
SPA
JET
2"
POOL
JET
SKIMME
MAIN
DRAIN
7'
2 11
1-1 /2"
SWAY JANDY
VALVE
211
DIRECTION
OF FLOW
POOL PLUMBING
NOT TO SCALE
FLOW RATE CALCULATIONS
GALLONS OF WATER REQUIRED FOR POOL 7594 GAL
GALLONS OF WATER REQUIRED AT SUN DECK 877
GALLONS OF WATER REQUIRED FOR SPA 878 GAL
TOTAL GALLONS REQUIRED 9203 GAL
FLOW RATE ONE EXCHANGE PER 8 HOURS
9203 DIVIDED BY 8 HRS = 1150 GPH
1090 GPH DIVIDED BY 60 SEC = 19.17 GPM
FEET OF HEAD CALCULATIONS
FOR 1-/2" PVC PIPE
TOTAL (SUCTION) PIPE LENGTH 55.5'
9.40HD
1 nn' DTDF X 55.5' OF PIPE = 5.217 FT OF HEAD
ADD
(4) 45° TURNS 4X2.4= 9.6 F.O.H.
(6) 90° TURNS 6X7.6= 45.6 F.O.H.
(1) 3 WAY DIVERTER = 2.3 F.O.H
TOTAL
57.5
57.5/100 X 7.76 = 4.46 F.O.H. FOR CONNECTORS
Pipe Lengths and Rise
5.21
valves and Turns
4.46
Cartridge Filter
7.5
Heater
7.5
TOTAL
24.67 F.O.H.
I SOMETR I C
2 11
DE FILTER
PUMP REQUIRED
HAYWOOD MAX FLO XL PUMP
2HP
MODEL NO: SP261OX15 OR EQUAL
>> SUMMIT
DESIGN & FORENSICS, INC.
725 SE PORT SAINT LUCIE BLVD.
SUITE 203
PORT SAINT LUCIE FL 34984
(772) 285-0572
BRIAN J. MASKOL
FL PE #66080
r
I
J
z
0
a
U
w
0
w
Q
0
z
0
>
w
w
w
U'-J
Ie
w
z
w0
C)
�-
zU
way
z�
Q�
w�
a'
w
a
0
U)
lD
r nD
V
CD
z
00
a
0
0
CL
DATE
DESIGNED
GMW
08-12-21
DRAWN
GMW
08-12-21
CHECKED
JOB NO.
2021-250
PM1