Loading...
HomeMy WebLinkAboutProduct Review; HeaterSELECTING THE CORRECT SIZE H-SERIES HEATER: FOR YOUR SWIMMING POOL Determine your pool's surface area in square feet: A L B R L W Area = (A+B) x L x.45 Area=RxRx3.14 Area =LxW H500 1,500 H400 1,200 H350 1,050 H300 900 H250 750 H2O0 .600 H150 450 In this table, locate the surface area that is equal to, or just greater than, the pool's surface area. To the left of this number is the appropriate Universal H-Series model that will fit the selected area. For indoor pool installations, divide the pool's surface area by 3. Table is based on a 30°F temperature rise, 3-1/2 mph average wind velocity and elevation of up to 2,000 feet above sea level. FOR YOUR SPA OR HOT TUB Determine your spa capacity in gallons (surface area x average depth x 7.5). The reference table lists the time required in minutes to raise the temperature of the spa/hot tub by 307 In the table below, locate the column with the spa/tub size in gallons that is closest to yours. Select the desired time to raise the spa/hot tub temperature 307, F, read to the left and select the appropriate Universal H-Series model This guide can be adjusted for other temperature rises. For example, if you desire a 157 increase in temperature, simply divide the time for 3o"F rise by the ratio of 30/15, or 2. (Note: Heat lost and/or heat absorbed by spa walls or other objects will add to the time it takes the spa to heat up) Spa sizing is based on an insulated and covered spa. Always cover your spa or hot tub when not in use to minimize heat loss and evaporation. H500 7 11 14 18 22 25 29 32 35 H400 9 14 18 - . 23 27 32 36 " 41 45 H350 10 16 21 26 _ 31 36 41 46 _ 52 H300 12 18 24 30 36 42 48 54 60 ^H250 15 22 29 36 43 51 58 65 72 H2O0 18 27 ^ 36 .54 63 72. 81, 90 H150 24 36 48 60 72 84 96 108 120 SPECIFICATIONS AND DIMENSIONS: UNIVERSAL H-SERIES HEATER 5001006 ' 399,900 - _82.7% 84% - 29-1/2" _ .__..24" 29-1/2" 24„ 2"x 2-1/27'_. ' .. 2" x 2-1/2„ Cupro Cupro Nickel - Nickel 6" 6" y 223 160 - r 3/4" 350,000 300,000 250,000 199,900 — 156,000 t 83%_ 82.7%-- _83% 83% 82.7%- 33„ 30" 28" 25" W 21" 29-1/2"—r_-_-29-1/2" 29-1/2" 29-1/2" , 29-1/2" 24" 24" 24" 24" 24" 2" x 2-1/2" 2" x 2-1/2" 2"-x-2-1/2" _ 2" x 2-1/2" 2" x 2-1/2" ; Cupro Cupro Cupro Cupro Cupro Nickel Nickel Nickel Nickel _--_.Nickel 8" 8" 4" 6" 6" W8" 61, _ 6„ 61, " 158-~~------_145 134 123 3/4" 3/4" 3/4" 3/4" 3/4" H-Series heaters are available in a comprehensive range of BTU sizes for natural or propane gas. All units are certified by the Canadian Standards Association and carry the exclusive Hayward° warranty 1 [0 IMAYWARD" Hayward and Hayward Energy Solutions are registered trademarks of Hayward Industries, Inc. © 2016 Hayward Industries, Inc. All other trademarks not mvned by Hayward are the property of their respective mmers. Hayviard is not in any rvay affiliated vfith or endorsed by those third parties. To take a closer look at other Hayward products, go to hayward.com or call 1-888-HAYWARD.