HomeMy WebLinkAboutNOA NOA No.: 21-0518.04
Expiration Date: 07/19/26
Approval Date: 07/15/21
Page 1 of 6
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Owens Corning Roofing and Asphalt, LLC
One Owens Corning Parkway
Toledo, OH 43659
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: TruDefinition® Duration®, and TruDefinition® Duration® Designer Colors Collection
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.17-1211.02 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 21-0518.04
Expiration Date: 07/19/26
Approval Date: 07/15/21
Page 2 of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
SCOPE
This approves a roofing system using TruDefinition® Duration®, and TruDefinition® Duration® Designer Colors
Collection asphalt shingles manufactured by Owens Corning as described in Section 2 of his Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Specifications
Product Description
TruDefinition® Duration®;
TruDefinition® Duration®
Designer Colors Collection
Manufacturing Location(s) #1, 2, 3,
4, 5, 6, 7
13 ¼" x 39 3/8" TAS 110 A heavy weight, fiberglass reinforced
asphalt shingle with large nail area with
bead of sealant.
MANUFACTURING LOCATION
1. Jacksonville, FL
2. Memphis, TN
3. Savannah, GA
4. Irving, TX
5. Kearny, NJ
6. Medina, OH
7. Brookville, IN
NOA No.: 21-0518.04
Expiration Date: 07/19/26
Approval Date: 07/15/21
Page 3 of 6
EVIDENCE SUBMITTED
Test Agency
Test Identifier Test Name/Report Date
PRI Asphalt Technologies, Inc. OCF-157-02-01 TAS 100 10/26/10
OCF-156-02-01 TAS 100 10/26/10
OCF-163-02-01 TAS 100 12/10/10
OCF-164-02-01 TAS 100 12/10/10
OCF-172-02-01 TAS 100 05/26/11
OCF-179-02-01 TAS 100 02/02/12
OCF-367-02-01 TAS 100 11/08/17
OCF-368-02-01 TAS 107 11/08/17
OCF-371-02-01 TAS 100 11/08/17
OCF-372-02-01 TAS 107 11/08/17
OCF-375-02-01 TAS 100 11/08/17
OCF-376-02-01 TAS 107 11/08/17
OCF-462-02-01 ASTM D 3462 05/11/21
OCF-469-02-01 ASTM D 3462 05/11/21
OCF-478-02-01 ASTM D 3462 05/11/21
1378C0004 ASTM D 3462 05/11/21
1378C0012 ASTM D 3462 05/11/21
OCF-501-02-01 ASTM D 3462 05/11/21
OCF-505-02-01 ASTM D 3462 05/11/21
Underwriters Laboratories, Inc. 10NK13947 TAS 107 11/12/10
11CA15662 TAS 107 05/27/11
11NB21712 TAS 107 02/18/12
12CA12180 ASTM D3462 03/01/12
R2453 ASTM D3462 10/20/17
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail 'B', attached.
NOA No.: 21-0518.04
Expiration Date: 07/19/26
Approval Date: 07/15/21
Page 4 of 6
LABELING
1. Shingles shall be labeled with the Miami-Dade Seal as seen below, or the wording “Miami-Dade County
Product Control Approved”.
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate
the installation of this system.
DETAIL A
NOA No.: 21-0518.04
Expiration Date: 07/19/26
Approval Date: 07/15/21
Page 5 of 6
DETAIL B
TRUDEFINITION DURATION
(SEALANT MAY BE CONTINUOUS OR DASHED. NOT SHOWN IN THE DETAIL DRAWINGS)
MAXIMUM SLOPE 21:12
NOA No.: 21-0518.04
Expiration Date: 07/19/26
Approval Date: 07/15/21
Page 6 of 6
SLOPE GREATER THAN 21:12
END OF THIS ACCEPTANCE