Loading...
HomeMy WebLinkAboutBuilding Plans Residential�:z�j 7-� cz� � PROPOSED rmESIDENCE-Z Fu" "A R: FDOH in St. Lucie County Environmental Health Site Plan Approved for Construction Supersedes All Previous Site Plans for S'o 22TA_*#JqD E E T OST'-)S #94-&Well # Date: Fogm-'r-117 PIE RC-1E FE 349"1822, Reviewe. AiLt_oU, PARCIEL 11D.- 242,8-602-0046--000-2 : BUILDING DEPARTMENT PROLDUCT APPROVAL SUBMI; TT AIL DA OPENING SCHEDULE- EXTE,"10"-R. S"A'ING DOICI-111D, 0VERHEAD DOORS, SLIDING GI -ASS DOORS, FIXED GLASS, AND WINDOWS 1. DESIGN LOADS IN ACCORDANCU WITH ASCE 7-16. 2. SOIL BEARING CAPACITY. 2500 3. ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICAL CELLS, AND COLUMNS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. 4. SLAB / ' FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS. 5. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" BEAMS: 1 h" SUSPENDED SLABS, I 1h" 6. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS EXCEPT AS NOTED GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS. 7. ALL LUMBER IN CONTACT NTH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 8. SPLITTING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALLATION OF HARDWARE Is NOT PERMITTED. 9. UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICES. 10. LINTELS SHALL HAVE A MINIMUM 4" BEARING. 11. PROVIDE # 5 CORNER BARS W/ 30" MIN. LAP SPLICE FOR BOND BEAM. 12. STUCCO CEILINGS AND SOFFIT NOTE: EXTERIOR CEILING AND SOFFIT TO BE STUCCO OVER WIRELATH W/ 11CA. 2" NAILS W/ 3/8" 0 HEAD 0 6" O,C. OVER 3/8" METAL RIB LATH 0 6- O.C. LAYERSOF 15# FELT OVER EACH FRAMING MEMBER). WITH 11 GA. 2- LONG NAILS WITH 318- 0 ,3. EXTERIOR FRAME WALLS TO BE STUCCO OVER WIRELATH HEAD 0 6" O.C. OVER (2) LAYERS OF (15# FELT OR TYVAK BUILDING WRAP) OVER 19/32- CDX PLYWOOD WITH 10D NAILS TO STUDS 0 6" O.C. PERIMETER AND FIELD. 14, BEARING POINTS 0 F TRUSSES SHALL HAVE VERTICAL STUDS IN A NUMBER EQUAL TO THE NUMBER OF PLIES OF THE BEARING MEMBER MEN THE BEARING MEMBER IS (2) OR MORE PLIES UNLESS NO,ED. ULL11111111111" 11INTERIOR 0 BE h" DRYWALL I jr-41SH. 2. ALL INTERIOR GYPSUM BOA-RD TO BE MIN. �6" THICK NTH (13 CAGE, 1 3/8- LONG, 19/64" HEAD; 0.098" DIAMETER, 1 1A" LONG, ANNULAR -RINGED; 5D COOLER NAIL, 0.086- DIAMETER, 1 5/8- LONG, 15/64" HEAD; OR GYPSUM BOARD NAIL, 0.0861, DIAMETER, 1 5/8- LONG, 9/32" HEAD) SPACED O.C. FOR NAILS AND 12- D.C. FOR SCREWS. 3. WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM. BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS AS BACKERS FOR WALL TILE IN TU13 AND SHOWER AREAS AND WALL PANELS IN SHOWEF AREAS. (PER FRC 702.4.1 & FRIC 702.4.2). 4. WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATERTHAN 450. 5. WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD CLASSIFICATION OF NOT GREATER THAN 200. S. ALL EXPOSED INSULAT10N MATFRIALS INSTALLED ON ATTIC FLOORS SHALL HAVE A CRITICAL RADIANT FLUX NOT LISS THAN 0.12 WATT PER SQUARE CENTIMETER. EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED TO THE UNDERSIDE OF THI ROOF DECK OR ON THE ATTIC WALLS SHALL COMPLY NTH SECTION FRC316. 7. PER FRIC 702.2.1 ALI GYPSUM 130ARD MATERIALS AND ACCESSORIES SHALL CONFORI TO ASTM C 36, C 79, C 475, G 514, C 630, C 931, C 960, C 1002. C 1047, C 117 C 1178, C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557. 8. INSULAT10N MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, ROOF-CEILIN ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDE NOT TO EXCEED 450 MEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. 1. THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ETC. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ETC. 2STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGiNIEER AS CONSTRUCTION PROGRESSES. 1 ALL WRIT71EN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE (FBC) 2020, FBC 2020 RESIDENTIAL, FBC 2020 PLUMBING CODE, FBC 2020 MECHANICAL CODE, FBC 2020 ENERGY CONSERVATION, AND •THE NEC (NFPA 70E) 2021 EDITION. 5RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY TERMITE INFESTATION AREA PER FIRC 301. ADDITIONS, REPAIRS, AND ALTERATIONS MUST CON'FlY WITH THE FB,C 2020 FOR EXISTING BUILDINGS. EaLmwazam 1ALL WORK SHA; 1 BE IN ACCORDANCE WITH THE FBC 2020-PLL:MBING 2. DWV PIPING SHALL BE SCHEDULE 40 PVC. 3. WAT.' PIPING IN BUILDING SHALL BE ONE OF THE FOLLOWING: TYPE L COPPER, . E R CPVC, CR PEX. 4SLEEVE ALL PIPING IN CONTACT WITH CONCREl OR UNDERGROUND WITHIN BLDG. 5. HOT WATER PIPING WITH A MINIMUM THERMAL RESISTANCE OF R-3 SHALL BE APPLIED TO PIPING LARGER THAN %" NOMINAL DIAMETER, PIPING FROM WATER C HEATER TO KITCHEN OUTLETS, PIPING LOCATED OUTSIDE THE CONDITIONED SPA I PIPING FRZOM THE WATER HEATER TO THE DISTRIBUTION MANIFOLD. PIPING LOCA UNDER THE FLOOR SLAB, BURIED PIPING, SUPPLY AND RETUN PIPING IN RECIRCULATION SYSTEMS, PIPING WITH RUN LENGTHS GREATER THAN 20 FEET. 6. WATER HEATERS INSTALLED SHALL BE IN ACCORDANCE WITH FBC 2020 ENERGY c' CONSERVATION. IAN:[ i�ll il!�I[ I mamcam 1• ALL - ELELRCAL WORK SHALL BE IN ACCORDANCE W1111- THE NECI:NF-PA 70) 2017 EDITION. 2. A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH -EFFICACY LAMPS OR A MINIMUM OF 75% OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH -EFFICACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED TO BE HIGH -EFFICACY LAMPS). 1 RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED AND UNCONDITIONED SPACES. 4, SMOKE DETECTORS TO BE 110V W/ BATTERY BACK UP - ARC FAULT CIRCUIT, 5, SMOKE DETECTORS TO BE LOCATED AS SHOWN. 6, SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE. T PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FOR ALL CIRCUITS SERVING- FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMC SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS P-R FBC AND NEC REQUIREMENTs, 8. PROVIDE kAOUND-FAULT CIRCUIT INTERR'k?TER PROTECTION FOR ALL 125-VOLT, SINGLE-PHASE 15 AND 20 AMP CIRCUITS SERVING: BATHROOMS, GARAGES, KITCHENS, ACCESSORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF EDGE OF ANY SINK. 9, CARBON MONOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALL BEDROOMS, M EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT, 11, PROVIDE 7AMPER RESISTANT RECEPTACLES PER NEC REQUIREMENT'S. GLASS ENERGY CONSERVATION NOTES PRODUCT DESCRIPTION MODEL MANUFACTURER ATTACHMENT METHOD PRODUCT DESIGN BUILDING DESIGN PRODUCT NUMBER DESCRIPTION T-T?__­: S7E. SPACING & EMBEDMENT PRESSURES (PSF) PRESSURES (PSF) APPROVAL, NO. 7 I . REaDENCE SHILA� -_ B 1 - N ACCORDANCE WITH FLORIDA BUILDING CODE 2020 ENERGY OVERHEAD GARAGE DOOR W6 CLOPAY CORP, N/A X AG SCREWz�, +36.0 SEE TIONS E ELEVATIONS #115546.4 Planning & Development.Services Department CONSERVATION ',�ESIDEN71AL, . .. . ....... Building & Code Regulations Division 2. ATTIC ACCESS OORS OR HATCHES FROM CONDITIONED SPACES TO UNCONDITIONED OPAQUE SINGLE DOOR FIBER -CLASSIC & THERMA-TRU IMPACT )4 'F i ��INIMUM EM'-_­__rD, TAPCONS A7 14�5' 0,C­ VAX, FL 2400 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1577 . .... ... �;' SPACES SHALLBEWEATHER STRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING �_,URFACES, A WOOD FRAMED OR w/SIDELITE SMOOTH -STAR SEE ELEVATIONS #2046�8.5 EQUIVALENT BAFFLE E OR RETAINER IS REQUIRED TO BE PROVIDED WHEN LOOSE FILL - -- - -------- certification for Design Load Compliance IS INSTALLED, TO PREVENT LOOSE FILI - I'ROM SPILLING INTO THE LIVING SPACE. 8' GLAZED SINGLE DOOR FIBER -CLASSIC & SMOOTH -STAR THERMA-TRU Mlil45MUM 7A:"ONS A� '4.- O.C. MAX.+/-50.0 SEE ELEVATIONS F1_ #20468.10 7th Edition 3. THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE Project Name: _RUQy.RQQRIGUEZ ....... ..... IN ACCORDANCE WITH THE REQUIREMENTS R402.4.1 THROUGH R402.4.4. COMPOSITE EDGE FIBER -CLASSIC & THERMA-TRU A ��IiNIMUM EYBED. 'TA. -CONS AT D.C. MAX, +/-50.0 SEE ELEVATIONS FIL #2:D4-6&4 Project Address: ..$.22NQ STIREET, FORT PIERCE -EL34982 4. THE BUILDING SHALL BE TESTED FOR AIR LEAKAGE IN ACCORDANCE WITH OPAQUE FIBERGLASS SINGLE DOOR SMOOTH -STAR R402.4.1,2 Permit Occupancy Type: R Construction Type; 111 5. WINDOWS, SKYLIGHTS, AND SLIDING GLASS DOORS SHALL HAVE AN AIR SINGLE HUNG WINDOW SERIES 185 MI WINDOWS 7 NIMUM EEMBED, TARCONS AT MAX./-55.0 SEE ELEVATIONS FIL #1749 9. 1 INSTRUMONS FOR USE: INFILTRATION RATE OF NO MORE THAN 0.3 CFM PER SQUARE FT. AND SWINGING AND DOOR LLC Tlh�s certification must be completed, signed, and sealed by the design professional of record. DOORS NO MORE THAN 0.5 CFM PER SQUARE FT AND MUST BE TESTED LISTED If submitting hard copy, submit (2) copies with all pertinent information. St Lucie Fire District requires a digitally AND LABELED IN ACCORDANCE WITH R402.4.3. PICTURE WINDOW 185, PW MI WINDOWS AND DOOR LLC MINI -MUM ��WaED, 7APCONIS AT 3"/R-' O.C. MAX. +50.0 -63.0 SEE ELEVATIONS FL #153�9�5] signed electronic version, If submitting electronically, form should be uploaded into Bluebearn. Separate submission to Fire is still required 6� CONTRACTOR SHALL PROVIDE ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD IN All digital files must be in an unlocked Portable Document Format (PDF) version ACCORDANCE WITH FBC 2020 ENERGY CONSERVATION R401.3, *Note: form not required for interior renovations provided that no exterior structural elements are affected and MODEL ATTACHMENT METHOD PRODUCT DESIGN BUILD:NG DESIGN PRODUCT certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions. PRODUCT DESCRIPTION NUMBER MANUFACTURER TYPE, SIZE, SPACING & EMBEDMENT PRESSURES (PSF) PRESSURES (PSF) APPROVAL NO. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) GARAGES FLOOR SURFACE SHVf,�LE FASTENERS: 1. DESIGN Florida FBCZQ20 Code 7th Edition using ASCE 7-16 FAQ71_NERS FOR ASPHALT SHINGLES SHALL BE COPPER ROOFING NAILS, STAINLESS STEEL, ALUMINUM OR STAINLESS 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open Coi-ER ROOFING NAILS. MINIMUM 12 GAGE :r0.105 INC 1`3 MM)l SHANK WITH A %"10 MM) DIAMETER k 3. Risk Category: _111 IV Exposure Category� X B C D I X tl GARAGE FLOOR SURFACES R' 1. GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL ASPHALT SHINGLES HERITAGE TAMKO HE/-'.;, ASTM F 1667, OF A LENGTH TO PENETRATE THROUGH THE ROOFING MATERIALS AND A MINIMUM OF Y4' VULT: 194 mph VULT: 150 �-Ph FL #181355A (19 f�M) INTO THE ROOF SHEATHING, WHERE THE ROOF SHEATHING IS LESS THAN Y�- (19 MM) THICK, THE 4. Design Wind Velocity____160 _mph ASD LRFD End Zone Width: ft E AREA OF FLOOR 2. THE AREA OF FLOOR USED FOR PARKING OF AUTOMOEOLES OR OTHER VEHICLES E I FAS�,it NER SHALL PENETRATE THROUGH. THE SHEATHING. FASTENERS SHALL COMPLY WITH ASTM F 1667. 5, Mean Roof Height Roof Pitch: 6 :12 Parapet:_ft s SHALL L BE: SLOPED T( SHALL BE ELOPED TO FACILITATE THE MOVEMENT OF 11,-0DS TO A DRAIN OR 6 PER SHINGLE) TOWARD THE MAIN V TOWARD THE MAIN VEHICLE ENTRY DOORWAY. & Components & Cladding Design Pressures Used: +24.2 +24.2 +22A ROOFING UNDERLAYMENT SAND-R SA TRI-BUILT SELF -ADHERING FIL #16048.R6 R Zone 4: __2_Q.2 7one 5:_-32A--. Garage: MATERIALS GROUP 6a. Roofs Maximum +/- +-- -_ Or define individual DOWEL ROD REPAIR, NOTES pressures: psf psf zones on the plans HURRICANE SHUTTERS N/A 7. Design Loads: Floor: __PSF Roof -Dead: 10 PSF Roof -Live: 2 BaIcony+1-_PSF 20 - ---------- -- Dock: PSF Deck: PSF Stairs:- PSF Fence:-PSF Railings: PSF INT' _7 C 1 0 S 0 DRILL 6" INTO CONCRETE (N CLOSER THAN 3Y4" FROM EDGES AND 5" FROM ENDS OF IN THE EVENT STEEL HAS BEEN INADVERTENTLY OMITTED FROM DOWN POUR 7LOCAT1I0N::] SOFFIT COVERING TO BE BUILT ON -SITE USING. 3/8" HI -RIB SELF FURRED EXPANDED METAL LATH WITH "K-PAPER" BACKING (CEMCO; 14 LBS/SQ. YDS, MEETING ASTM C847) FASTENED TO EACH ROOF TRUSS WITH NOT APPLICABLE 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Please Explain: CAP WALLS). REMOVE DUST PER MFC'S INSTRUCTIONS AND USE TWO PART EPDXY TO Z SOFFIT COVERING STUCCO STUCCO #B(MIN) x 1 1/4" PHILLIPS PAN/TRUSS HEAD SCREWS (18-8 S.S. OR GALV, ASTIM A307 STEEL) 5' NOT NOT -i-28.0/-37.0 (FBC-R616. & 4 & ANCHOR EPDXY- #5 REBAR IN PLACE. USE EITHER HILT C-100 OR SIMPSON EPDXY-TiE. TIF. O.C. MAX (2 SCREWS PER EA. SQ. FT. OF LATH), 5/8- THICK MIN, CEMENT STUCCO MIXED AND APPLIED IN APPII ;WAIL ZONE 5)) . R703.1.1) 9. Is a Continuous Load Path Provided?__X Yes Not Applicable Explain Wfiy Not: --- CONFORMANCE WITH ASTM C926. 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes No Assumed -- -- ---- - - -------- DESIGN PROFESSIONAL CERTIFICATION STATEMENT: IT IS THE INTENT OF THESE DRAWINGS TO SHOW GENERAL REQUIREIVIENTS RELATED TO THE 1, ALL GLAZED EXTERIOR OPENINGS SHALL BE IMPACT OR PROVIDED WITH SHUTTERS. I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to CONSTRUCTION OF THIS PROJECT, IT IS NOT THE INTENT TO SHOW EACH AND EVERY PIECE EVERY 2. MAIN EGRESS DOOR MUST BE IMPACT RESISTANT. comply with the applicable structural portions of the current Florida Building Code as adopted. OF MATERIAL OR EVERY METHOD REQUIRED FOR SOUND CONSTRUCTION. THE CONTRACTOR] EHASBEGAN. 1 ALL GLASS SHALL HAVE A U-FACTOR LESS THAN OR EQUAL TO 0.40 ABD SHCC LESS OR EQUAL TO 0.25. i J J C SHALL CHECK AND VERIFY ALL DIMENSIONS BEFORE STARTING PROJECT. JOAN JAFFE I IS Z 4. WINDOW AND DOOR FENESTRATION SHALL BE IN ACCORDANCE WITH FBC R703.4 (1.2) AS PER DETAILS PROVIDED NOT RESPONSIBLE FOR ANY ERRORS OR MISTAKES ONCE CONSTRUCTION IN CASE BRIAN MASKOL CERT #66088 OF QUESTIONS, PLEASE CONSULT JOAN JAFFE LLC AND SUMMIT DESIGN & FORESICS. INC. Signature, Date, andSeal -Print Name Cert # &Co. Cert o(Authorization I HAVE REVIEWED THE ABOVE PRODUCT APPROVAL INFORMATION AND APPROVE I l, SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT ST L all BLVD., PORT ST _LUCIE FL 34984 Revised 3/2512021 Company Name & Address NAME. BRIAN MASKOL, P.E. CERTIFICATE NUMBER: 66080 REVIEWED FOR COOE C01\4PLIANCE ST� LUCIE COUNTY DF-6--prING SERVICES roux JAMqL � PHONE: (772) 237-79C WWWTREAStMEWASTDRAMINOCOM Z 1.4 �z U U Z 0 U 0rn i-0 ICI 1Z I I O 0 VIC) 00Q Z L U > 0 0 �4 U U W Z l­- V) V) OD > Z U) [L- 0 LLi IAJ u! L� cc 0 U U N LL =) :D _J _J U11) Z 0 C) L,n a- CL LLJ W Ln Lr) Date: SCALE: N. T.S JOB No: 520-1072 C i pr•1 F`7177 I{ --TYPICAL 8" CONCRETE BLOCK WALL (SEE SHEET—A5/DETAIL 1) 5g-0" �0k3 III LE L J L _I 36" x 36" x 24" DEEP F1 IF — P1---J I III I AII I II 7_ I I I I � I I I I I I L (FIELD LOCATE BY OWNER) RUN CONDUIT FOR L — — ELECTRICAL TO ISLAND I I (2500 PSI) CONCRETE PAD FOOTING WITH (4)—#5 BARS EACH WAY II (TYPICAL OF 2) F6 F IAl (n Al I I F5 F1 P1 P1 711 --#5 VERT DOWEL REINF. 0 ALL WALL OPN'N,/JAMB, ALL CORNERS, UNDER ALL GIRDERS / AND AT 48" O.C. MAX. (TYP.) 1 O FS ■ I Al A7 , ®Ca u 4" THICK SLAB (2500 psi min.) I 11 ® / I L _I 1 F9 REINFORCED w/ 66 — W1.4xW1.4 WOVEN WIRE MESH — ®■ ■ ■ ■ I III — _J I Al (OR FIBERMESH) ON 6 MIL VAPOR BARRIER OVER j CLEAN 95% COMPACTED TERMITE TREATED ■ -- —� Al I �; PREPARED SUBGRADE HW �J 0, Al FI F4 Al ■I I ■ ■ ■ ■ " WALL BOTTOM EDGE _ I' (A Al I ""`b°~®27"X4'4" THICK ■ 2" MIN. POURED CONCRETE UTILITY ®® �.- ■ SLAB REINFORCED ® WITH FIBERMESH 0 I I I � 1 F3 F3 16X16 CMU ---- A1 Al COLUMN WITH < �;I ® (4)-5 BARS RECESS S AB 4 ELW FIN BOISH FLOOR ■ HB — A1 FOUNDATION PLAN SCALE: 1/4" =11-0" 8' MASONRY WALL, SEE PLAN #5 REBAR 048$ O.C. (MAX.) do AS SHOWN ON PLANS �%"XB" WIDE BLOCK RECESS FINISHED FLOOR �--� 4" THICK (MIN.) POURED CONC. (2500 PSI MIN.) FINAL GRADE w/FTBERMESH ' 1i/ //i�;/ /i`/i��i�i��� 12" MIN. EMBEDMENT BELOW EXISTING GRADE / 3 MIN. CI (2) 5 CONTINUOUS REBAR 1`_-_4"" CLEAR COVER MIN. (TYP.). 0 (C,j'�:�)TERIORFOOTING I If PC co L-- ■ 3'-10i1 1129 "L 10 = MASONRY WALL, SEE PLAN 5 DEBAR 048" O.C. (MAX.) do AS SHOWN ON PLANS 7-%" CURB 4" THICK (MIN.) POURED CONC. (2500 PSI MIN.) FINAL GRADE w/FIBERMESH "- ���/� 12" MIN. EMBEDMEN%, ✓/ BELOW EXISTING GF��ITE � �,. 3" MIN. (2) ;#5 CONTINU=U REBAR---, 1 -¢" 6" -CLEAR COVER MIN. (`)` TION CURB SEC - 136ARINC - SCALE: 3/8"=1"-0.tl " MASONRY WALL, SEE PLAN 5 REBAR 048" O.C. (MAX.) AS SHOWN ON PLANS X4"X8"WIDE BLOCK RECESS C 4' =}-TICK (MIN.) POURED " POURED CONC- CONC. COLIC. (2500 PSI MIN.) PORCH SLAB w/FIBFRM.F ESH 12" MIN. EMBEDMEN I BELOW EXISTING GRADE 3" MIN. (2) #5 CONTINUOUS REBAR V-4• 16- CLEAR COVER MIN. MIR.). T _ T DEARItJi� 4" 1HICK (MIN.) ®^!'or^ CONC. (2500 PS w/FIBERMESH THICKENED EDGE FOOTING WITH ('� r1 BARS CONTINUOUS _00TING AT ENTRY PORCH SCALE: 318°" = ` -0"k I 4" OR 6" 2x4 FRAMED WALL 1 " SEE TYP. DETAIL FOR ,�" DIA.AO" A.B. 024 O.C. -. CONNECTION TO FOUNDATION MAX. W/7" MIN. EMBED. 2" (MIN.) P.T. SOLE PLATE 4" TRICK (MIN.) POURED F.F. CONIC. (2500 PSI MIN.) ...,;, / 557 1"-4" MONOLITHIC CONCRETE FOOTING WITH (3) #5 BARS CONTINUOUS 1 ��aa RING SCALE: 3/8"" � 1e�"q 1 a" VERIFY W/ DOOR MANUF. 7 F/ �tl THICKENED EDGE -----1 L 2°-0" SCALE: 318" d.� 2x4 FRAMED NON -BEARING ,k" DIA.x10" A.B. 2.4" O.C. WALL SEE TYP. DETAIL FOR MAX. W/7" MIN, EMBED.` CONNECTION TO FOUNDATION 2" (MIN.) P.T. SOLE PLATE VV 60 F F, Q 4" THICK (MIN.) POURED CONC. (2500 PSI MIN.) " 12 `�.a 8X6-1N1,4xW1.4 WWM cj (OR FIBERMESH) #55 BARS CONTINUOUS INTERIOR STEP -_ NON -BEARING— - —,SCALE: 318" = `1%0" 4" THICK (MIN.) POURED 7-5/8" CURB CONC. (2500 PSI MIN.) VARIES 8" w FINAL GRADE a v,�%�\`%�/j\i%� 12" M'N. EMBEDMENT 41 BELOW EXISTING GRADE (2) #5 CONTINUOUS REBAR " - 6X6-W1.4xW1.4 WWM DOUBLE WITHIN 3 FT. MIN. FROM FOOTING (TYP) (OR FIBERMESH) INTERIOR SHOWER CURB ! - - — -- - ° SCALE: 318"ti = 11%0" ca THICK (MIN.) POUREI. i rr PSI MINJ� R" #5 BARS CONTINUOUS Lv-o-l. THICKENED EDGE �7/ SCALE: 3/8" = I %0 " p _ 2x4 FRAMED BEARING WALL SEE TYP. DETAIL FOR CONNECTION TO FOUNDATION " OI;A.x'IO' A.B. 024" O.C. MAX. W/7" MIN. EMBED, 6X6--W1.4xW1.4 W9/ (OR FIBERMESH) 2' (MIN.) P.T. SOLE PLATE cn z F-aI. 4" THICK (MIN.) POURED CONC, (2500 PSI MIN.) —r -^---r L r"s ¢ MONOLITHIC CONCRETE 2"-0" FOOTING WITH (3) I BARS CONTINUOUS F �'O)I_. ZMROR SCALE: 3/8" = I'-U" REVIEWED FOR CODE r ° Yr: . ij� � DRAFTING SERVICES JOA JAFFS, r . r PHONE: (772) 237-7942 A'R`W TAHASURECOASTDRAMNO.COM 41 Z Q � v z r4a a Q A U 0 Z u h-I A z rn vUJ N Z t) V) CO ;mr, Z ��N LLI [0 C? �� 00 as Q � vie N zV +n a_ a LIJ w ®® Ln Ln �Y q Date: , SCALE: AS NOTED JOB No: 520-1072 kv CONCRETE ! lD•NOTES 1. 's / FOOTINGS TO BE CONCRETE 2500 PSI COMPRESSIVER: DAYS. . CONCRETELAN FOR SIZES & STEEL REQUIREMENTS. 2. MINIMUM PROTECTION Or REINFORCING BARS:FOOTINGS: . \ i PREPARATION NOTES 1. THE AREA OF • 1' fN ..LL .VE ALL VEGETATION, _.OP SOIL AND FOREIGN REMOVED.MATERIAL 2. CLEAN FILL SAND AND OR GRAVEL OF VEGETATION AND FOREIGN MATERIAL, -M PLACED TO DESIGN SUBGRADE LEVEL AND COMPACTED TO ASSURE UNIFORM SUPPORT OF THE FLOOR SLAB. 3. SUBGRADE COMPACTION SHALL BE ACHIEVED BY MEANS AND METHODS DETERMINED BY THE RESPONSIBLE A+B CONTRACTOR. r..f.r SOIL DENSITY TESTING BY INDEPENDENT SOILS f .... REQUIRED !. INSURE PRESCRIBED --C ri SOIL DENSITIES ACHIEVED, 4. AFTER FOOTING EXCAVATION,AND FORMING, UPPERCONTRACTOR SHALL RECOMPACT SUBGRADE SOILS USING SUITABLE VIBRATORY MECHANICAL COMPACTOR. THE OF f UNDERLAYING FOOTINGSWALL f ! HAVE A MINIMUM DENSITY OF r OF DRY DENSITY DETERMINED BY MODIFIED PROCTOR •f FOR THE SOILS.EXISTING - O DENSITY SHOULD BE PERFORMED r !r ACCORDANCE wi s D-2922, AT A FREQUENCYDETERMINED BY THE SOIL TECHNICIAN +, VERIFY UNIFORMITY UNDERLYING SOIL DENSITY,PRIOR rfw PLACING CONCRETE. 5. LOOR SLAB FILL MATERIAL SHALL COMPACTED ! i. MINIMUM DENSITY EQUALO 9 OF DRY UNIT DENSITY OF DETERMINED BY MODIFIED PROCTOR METHOD IN ACCORDANCE ASTM D-1557. 6. CONCRETE SLABS ON GRADE SHALL BE PLACED OVER p. POLYETHYLENE . ■ fr BARRIER r. s .r. WITH A MINIMUM JOINTSTHICKNESS OF 6 MILLS, INSTALLED WITH LAPPED NOT AND CONTINUOUSLY TAPPED NTH HIGH DENSITY POLYETHYLENE ADHESIVE 2" AUTO VENT ALL DOWELS AND VERTICAL BARS ARE #5 2. #5 DOWELS 41- d it I yea 3. ATTACH DOWELS TO 'FOOTING STEEL 4. VERTICAL LIARS TO EXTEND 'TO TOP STEEL AND HAVE HOOKS EQUAL TO DOWEL HOOKS 5. FILL CELLS AT VERTICAL DOWELS 6. GROUT TO BE 3000 PSI AND REBAR TO BE GRADE 3" VTR � JIL 23, I 3b9 VTR I I 11TU B WC + KS U'� LAV '$ / I p , !1 3Y I 2� 3Y3 BATH #2 � '- A"1 KITCHEN -' -ram I � I SHW ' - 31# e\ MASTER WC ,_ BATH .. �s \ 3➢S \ NNI \ \ y \ +. ISOMETRIC RISER DIAGRAM SCALE: N.T.S. 4" (MIN.) BUILDING SEWER TO ON —SITE SANITARY SEWER LIFT STATION SCALE: N.T.S. REVIEWED FOR RE COMPLIANCE ,- L ij� I DRAFTING SERVICES 10w rwrrs,r PHONE: (772) 237-7942 W W W.TRWURECOASTDRAFfINO.COM N N r ry ti Fi F � W uz a A A U 0 * 0 � A H A z �Qr V N W N N� ~ wen 0 � O H OUN °zw�N �+ .. vaA W �U � a U I0-0 04 {0 y i I� O N LU Z (n CO . O j _j n �'��I LJJ co F1 W Ln p 00 U N Il J N v ZLi a 0 LJ W Q Ln N Date: SCALE: N.T.S. JOB No: 520-1072 A2 Zmm 8 '-0" 3, —0" 8°—!�'a 1 5a-011 1 02—Var ■ ■ PRE -CAST LINTEL tE ■ 2'-4" 3'-4" 2`-4 7'-2" 14'-2 1 IJ '-9" 5`-11" 24"X "PW 24" "PW I COV. PATIO is _00 ■ ■ ■ ■ ■ ■ L-7 W-j ", L-7 �I 9'-4" CLG CONC. N ■ L-3 L-3 ■ HB ■ ■ 37"X50" SH TEMP. L-4 ! 54"X63" 1H EGRESS ■■ ■■ ■■ ■ ■ Ell ■ ■■ ■ ■■■ ■ ■■ c ■ � - Wiz. ■ 0I — _ PANTRY I ''- I w ■ tl � � i DW _ M. BATH I � ,1 — `", ° '-4" CLG/TILE a I 3rr bra {yKITCHEN I!I P'f1 I � ILW P L-3 ■ F:3 Q VAULT CLG/TILE i BEDROOM #3 c ■ 9'-4" CLG/TOLE r 4'-0" �, ■ I W.I.C. WL IC. i I N _co CAI I ! o y ■ I m y VERIFY ISLAND r r LW SIZE WNOWNER LOCATION 2880PKT "' — 0 22"X30' 6080 OF' co 0 CID ATTIC 17 w/GASKET N ■ u, EWA 4f-31 " 3`-6 4 3 a �I tz cc I,- HB N L®5 x � _ ■ i0 5#-5I. I y r w MASTER SUITE "'�VANITY B H #2 LA I ■ GREAT ROOM Lo £- ■ tl 9'-4" CLG/TILE Lo I L_3 00 I VAULT CLG/TILE ( l icy �c I Lu I C. 7 W ■ ! 0 I I 60 0 F tl `� �00 L-5 � +9 /'y °°p 12 a-8 It 219-0 " 3'-4 " 8'—O;yfa BRG. WALLrF ] i ■ AHU _ W BEDROOM #2 ' IIQ°III �> L�J ..; Q o a ■ ■ ■ i J� 31:I la a j 9'-4" CLG/TILE b; ■ r = MAIN EGRESS a DRYER = / DOOR PER j � 3"DlA.x48" STEEL GUARD POST VENT VTR 8 OSC WITH °3 pp# FBC R 311.2 7- w/Y4"x10" SQUARE BASE w/(4) W TER STRIP w/1 eSIDD.ITE L-2 L-2 3�"x2 Xz" WEDGE BOLTS 2a-Ml . FI RATED � ■ ■ LF- OSING ol Is ■ ml mr INN Joe Sc _, 54"X 3" SH 54"X63" S EGRESS w/ EATHER ST IP 14'-3 ar 3'- " 3'-5�`" L-, �Lu L-fl *DESIGN FOR STORAGE I = I 10a —9as L-4 4a a12a —2a5a —11» F 22" X 54" ■ �w STARS _j ENTRY i i ,a (FIELD I:LOCATE) ■ ■ 12'-0" CLG/CONC. ■ a. 2 ■ PRE -CAST LINTEL ■ idy I _ co L-7 7 c� ■ i•) 04 II 2—CAR GARAGE N 16X16 CMU 9'-4" CLG/CONC. ■ COLUMN WITH ■ (4)—#5 BARS Q N Z. 20'-83 r' HB ■ i ■ ■ ■ ■ ■ ■ ■ ■ ■ 16'x6' OHGD L-6 3'-0" 16'— 3'-01' 22'— 0" rya-071 24r-03' 55'-019 FLOOR PLAN SCALE: 1/4" =1%0" PRECAST R CONCRETE SCHEDULE: PROVIDE PRECAST CONCRETE "U" LINTEL AS MANUFACTURED BY CAST-CRETE (OR EQUAL) FOR y ' - 'i a REINFORCEDOF THE SIZE AND REINFORCEMENT NOD IN THE FOLLOWINGSCHEDULE: MASONRY WALL LINTEL SCHEDULE LINTEL y LINTEL LINTEL LENGTH TYPE SAFE GRAVITY LOAD APPLIED GRAVITY LOAD SAFE UPLIFT LOAD APPLIED UPLIFT LOAD 400 1000 1. COMPOSITE BEAM DEPTHS SHOWN ARE MINIMUM REQUIRED, AND MAY BE INCREASED IN FIELD WITHOUT ENGINEER'S APPROVAL. 2. CALCULATED APPLIED GRAVITY LOAD AND APPLIED UPLIFT SHOWN ARE WORST CASE, ROOF TRUSS GIRDER LOADING HAVE BEEN CONSIDERED, 3. MASONRY CONTRACTOR TO VERIFY EACH MASONRY OPENING WIDTH AND HEIGHT PRIOR TO CONSTRUCTION. 4. LENGTHS OF LINTEL SHOWN ARE ACTUAL LINTEL SIZES (BEARING OF 4" EACH END). SAW CUT BOTTOMS OF LINTEL MANUFACTURERS NOTCHES WHEN NEEDED TO EXTEND REBAR THROUGH LINTEL @ EACH SIDE OF OPENING. 5. ALL LINTELS SHALL BE SET TO PROVIDE A MINIMUM 4" BEARING ON MASONRY AT EACH END, UNLESS DETAILED ON THESE PLANS. 6. REINFORCED PRECAST "U" LINTELS SHALL BE MANUFACTURED WITH 5 1/2" LONG NOTCHES AT EACH END TO ACCOMMODATE PLACEMENT OF VERTICAL REINFORCING AND GROUT FILLING CELLS BELOW. 7. SEE TYPICAL LINTEL SECTION FOR CAST-CRETE DESIGNATIONS AND PLACEMENT OF REINFORCING STEEL. F = FILLED WITH GROUT / U =UNFILLED rQUANTITY OF #5 FIELD ADDED REBAR AT BOTTOM OF LINTEL CAVITY tt Fib--1 z /1T 0 L QUANTITY OF #5 FIELD ADDED REBAR AT TOP NOMINAL HEIGHT NOMINAL WIDTH WALL CEILING HEIGHT 0 8'-0" OPENING WIDTH OPENINGSTYPICAL IWERIOR ARCH DETAIL **NOTE: ALL ARCH A MINIMUM 80" CLEAR .D HEIGHT — #5 FIELD ADDED REBAR AT TOP MIN. (1) REQ'D 1-1/2- CLEAR ® 8" BOND BEAM BLOCK (RINKER/CEMIX #T81 OR EQ.) ___._ GROUT SOLID (3000 Ps!) — #5 FIELD ADDED REBAR AT BOTTOM OF LINTEL CAVITY 81`16-1 B/1 T LEGEND ❑—❑—❑ • " • s%//////.�J,///l/%i7 . , O 10 0 8" PRECAST LENTIL R--11 INSULATION INTERIOR 2x4 STUD BEARING PARTITION WALL INTERIOR 2x4 STUD NON —BEARING PARTITION WALL PRE —CAST CONCRETE LINTEL DESIGNATION (SEE SHEET A3) SOIL PIPE VENT THROUGH ROOF WINDOW MARK (ALL IMPACT) 5403 SH (54"W x 63"H SINGLE HUNG) (SEE MANUFACTURER'S SPECS FOR DETAILS) 300 DOOR MARK (ALL IMPACT) (3'-O"W x 8'-O"H OPENING) NOMINAL LIVING: 1,660 SQ. FT. GARAGE: 504 SQ. FT. ENTRY PORCH: 56 SQ. FT. COV. PATIO: 100 SQ. FT. TOTAL: 2,320 SQ. FT. WINDOW AND DO IR_NOTE _ ** IT IS THE RESPONSIBILITY OF THE WINDOW AND DOOR SUPPLIER TO COORDINATE ALL REQUIRED OPENINGS WITH THE CONTRACTOR PRIOR TO ANY WORK, THE WNDOW SUPPLIER IS RESPONSIBLE FOR CODE COMPLIANCE OF HIS PRODUCTS. SHOWERS/ UBS SHALL HAVE FLOORS AND WALLS TO 70" OF NON -ABSORBENT MATERIALS AS PER FBC 2020 REQ. ALL GLASS ALONG A TUB OR SHOWER, WITH A SILL LESS THAN 60" SHALL BE TEMPERED AS PER FBC 2020 REQ. ij� 13RAF LKG SERVICYS JOAN JAP l I c PHONE: (772) 237-7942 W W W.TRBASURECOAS7DRAFTING.COM O � s11 A z a A A U 0 z M•I A A z N wN O N O 1 +T �0 p , QA�� QU N w�cNvaA 1.0 0 rl N v Lu �z I-_ =) V woo .at, jCM N z J LL Ln Luca o Lu u 00 O UuN LL J J N V ��v a N n.. LU w In i r. Date: SCALE: 1/411= 1'-0" JOB No: 520-1072 A 3 8'-0"" T. 0. W. 1 6"O.H. (TYP.) 6"X18" SCREENED - SOFFIT VENTS SPA. 0 6'-0" O.C. MAX. 0'-0" F.F.E. 10 %iln. (TYP.) 6"X18" SCREENED - SOFFIT VENTS SPA. 0 6'-0" O.C. MAX. 16" SQ. MANSORY COLUMNS FRONT VIEW ELEVATION e- e- TEXTURED CEMENT STUCCO COATING OVER 8" CMU BLOCK WALL (TYPICAL) .A - - - - - - - - - - - - - - - - - - - ----- X 0 021 < - - - - - - - - - - - - - - 0 REQUIRED VENT, 2,320 FT2 (144 IN 2 /FT2)/150 = 2,227 IN 2 0C. SOFFIT VENT. 257 FT FiT . = 42 VENTS 42 VENTS (6"X18"XO.5) = 2,268 IN 2 RIDGE VENT. 17 FT (12 IN/FT)(1.5 IN) = 306 IN 2 TOTAL 2,574 IN 2 Ak 0'-0" F.F.E. LEFT VIEW ELEVATION 12'-0" BRG. 9'-4" 8R& FAI 16"O.H. (TYP.) m ASPHALT SHINGLES (TYPICAL) WIND PRESSURES AS PER ASCE 7-16 E--XTERIOR OPENING DESIGN PRESSURE CHART 160 MPH EXP:B MARK AREAro 7 E ZONE 4 i BONE 5 POSITIVE (PSF) NEGATIVE (PSF) POSITIVE (PSF) I NEGATIVE ("FISF) -4-22.7 -24.6 +22.7 -30.3 2 15.0 +22.1 -23.8 +22.1 -29.1 3 20.0 +21.6 -23.0 +21.6 -27.9 4 25.0 +21.4 -22.9 +21.4 -27.5 5 30.0 +21.2 -22.8 +21.2 -27.1 6 35.0 +21.0 -22.6 +21.0 -26.7 7 40.0 +20.7 -22.5 +20.7 -26.2 8 45.0 +20.5 -22.3 +20.5 -25.8 9 50.0 -221 +20.3-,-- -25.4 - -------- 10 ---.-+,20.3 110 +19.3 -20.5 +19�3 -210 MEASURED AS 4'-0" FROM BUILDING (.-,ORNER A-i 16 8' RIDGE VENT Lu U LLJ ��LJ � Lu�u LLJ � �� I -l� i---l-L��LJ���I� �L1 I.;o TEXTURED CEMENT Ld STUCCO 'COATING OVER Ld 8sp CMU BLOCK WALL 11 (TYPICAL) a - - - - - - - - - - - - - - - - - - - - - - - --- Ir - - - - - - - - - - - - - - - - - - - - - - - - - M w A w -00 TEXTURED CEMENT STUCCO COATING OVER --/ 8" CMU BLOCK WALL (TYPICAL) - - - - - - - - - - - - -- wo < 0 i READ VIE-W ELEVATION REVIEWED FOR 0 0 E C OWPt P L I A IN C E 53 0 c c DRAFTING SERVICIRS JOAN JAa4%. PHONE: (772) 237-7942 www.T-REAsuREcoAsTT)RAFriNo.com Z z u 0 'o 0 FH rA zd W4 0 0 ccq) V) U 00 �� llt�l 0o Q g p Z � cq 0614, Ia u uo 0� 0 w w U 0 rlj Z Lu Ln M jmn z u_ Ln Lu ld Ln u u CN, OD D D LL _j _j IL/w)0 N N F- L/) 0 CL C n- LLJ LLj Ln Date SCA.LE: 1/4" = F-0" JOB No: 520-1072 A4 V THICK CEILING RATED GYPSLJM----" WALLBOARD SHEATHING (OTHERWISE NON -RATED %" THICK GYPSUM WALL BOARD IS REQUIRED) Y2" GYPSUM WALLBOARD SHEATHING OVER — I x2" (NOMINAL) P.T. FURRING STRIPS 0 AND WITH R4.1 FI-FOIL INSULATION 8" PRECAST LINTEL #5 BAR IN (3000 PSI) CONCRETE FILLED CELL AT ALL DOOR AND WINDOW OPENINGS (SEE LINTEL SCH. FOR MORE INFORMATION) WOOD BASE BOARD POURED CONC. (2500 PSI FLOOR SLAB WITH 6x6-W1.4xW1.4 W.W.M. (OR FIBER MESH) OVER 6 MIL POLYTHENE VAPOR BARRIER & COMPACTED TERMITE TREATED C! - EAN SOIL FILL (SEE SHEET 42 FOR FOUNDATION O NTES) ASPHALT SHINGLES OVER ICE AND WATER SHIELD PEEL AND STICK (COLOR & PROFILE TO BE SELECTED BY OWNER, TYP.) 19/32" C-D STRUCTURAL I PLYWOOD SHEATHING OVER PRE-ENGINEERED WOOD TRUSSES 0 24" O.C. (SEE ROOF FRAMING PLAN SHEET-R1 FOR ROOF SHEATHING NAILING SCHEDULE) 12 16 (TYP) (EE RSHEET-R1 FOR TRUSS CONNECTOR SCHEDULE) 114M WMIR • .7 7 ........................... .................. .. ..................................... ........ ...... ...... ...... ...... ...... ...... ...... ......................................... ...... .... .. ...... .. .. ......... .................... ............. ..... ..... .... LO ................................................... ....................... ...................... ... .................................................... ............... ................... ..... il""""*"""",*,""""""""""""""""I K""I V ='FI' L, 41 — F% 3" MIN. CLEAR COVER (TYP,). 16" TYP. TRUSS TAIL 2X" ALUMINUM DRIP EDGE OVER 1x3 P.T. NAILER O.H. BEARING HEIGHT EL. VARIES SUB -FASCIA BOARD ,x6 ­ASCIA BOARD FASCIA OR P.T. \—METAL LATH AND STUCCO SOFFIT PROVIDE 6"X18" SCREENED VENTS AT 6' O,C. OR 4" CONTINUOUS VENT (SEE ROOFING NOTE #4) CONT. 2x4 P.T. LEDGER BOARD w/ Y4"xY TAPCONS 024" O.C. (OR BETTER) DOUBLE COURSE 8" CMU KNOCKOUT/BOND BEAM BLOCK GROUTED SOLID WITH (1) # 5 REBAR CONTINUOUS EACH COURSE NEW 8" CMU WALL CONSTRUCTION WITH TYPE "M" MORTAR " MIN. CEMENT STUCCO COATING #5 VERT. REBAR AND #5 DOWEL BARS WITH STD. 10" LONG HOOK (MIN.) GROUTED SOLID. SET DOWELS AS INDICATED ON PLAN 30" MIN. LAP SPLICE (TYPICAL) FINISHED FLOOR SLAB,,� FINAL GRADE 12" MIN. EMBEDIVIEN'T BELOW EXISTING GRADE (2) #5 CONTINUOUS REBAR PRE -CAST ("'ONC. LINTEL SEE LINTEL SCHEDULE SIZE & REINFORCEMENT II �II II DA. WEDGE ANCHOR II 3-75" EMBEDMENT w/2" SQUARE WASHER II II II II II II II II II II II II II II II U- r 16 LONG 2x8 P.T. (SYP) BLOCKING FOR TORSION SPRING (AS REQUIRED) I II - - - - - --- - - - - - - - - - - II Ih III II II 2x6x16"-0" P.T. (SYP) ATTACHED CHEDII w/ Jle4"O x 3" TAPCONS 016' O.C. w/ 1" DIA. MIN. WASHERS II II II II Won, =61RIEffill ......... 0 4 = WA 14 10 LAX01 X 112 V10 I 11#10 IMUM WIMPSON TIE -STRAP TYPE SPH6 10d x 1-Y2" NAILS ON TOP & BOTTOM OF ALL STUDS AND 0 HEADER SIMPSON MSTA18 w/(14) 10d NAILS ACROSS HEADER 0 ALL DOOR OPEN'G '11i EYTERIOR (3) 2XII 2 8" CMU WALL (ALL -- CELLS MUST BE GROUTED SOLID AT PLATE CONNECTION) FACE NAIL FULL STUD TO JACK w/10d GUN NAILS @12" O.C. -C-4 STAGGERED -----157��2x6 P.T. (SYP) WOOD JAMB FASTENED II wl %"x3-Y2" (S.S. 304) HILTI KWIK BOLT 2x6 FRAMING SPF - Y4" 0 x 3-k4" " 0It 0 - 3 EXPANSION ANCHOR (OR EQUAL) w/ 2" #2 @12" O.C. (SEE. FULL STUD TAPCON E;CF?EWS 1 SQUARE WASHER (SEE BUCK DETAIL) 0 II II II SET 024" O.C. _Ir .1 w PLANS FOR LOCATION) JACK STUD--\ MAXIMUM c 00 w II II SIMPSON SPH6 3z 0 (TYP. AT ALL I STUDS) 114 P.T, (2x6 FRAMING P.T. (2X6 FRAMING)- CONT. SOLE PLATE MAX GARAGE FLOOR SLAB I 0 A A GARAGE AJI 41-- (0"-10") FLOOR SLAB �FTOP SLAB, FTC L. ----------- SET Y2"O x 10"(MIN.) J-BOLT (7" EMBED.) FOOTING PER FOUNDATION PLAN (2)#5 DOWEL WITH 30" 024" O.C. OR N'0 x 8" LONG REDHEAD OVERLAP "TRUBOLT" WEDGE ANCHORS (6'* EMBED.) 016" O.C. w/2"O WASHERS - FOR ALL BEARING WALLS ?4 MN (AND ANY WALL RESISTING UPLIFT) TYP. BEARING WALL FOOTING OR THICKEND SLAB) SEE FOUNDATION PLAN FOR DETAILS SHEET-P1 TYPICAL EXTERIOR WALL and FOOTING SECTION 2 OVERHEAD GARAGE DOOR GOAL POST 3 � TYPIC-''AL INTERIOR WOOD FRAME BEARING WALL SCALE: 1/2" = 1%0" A5 SCALE: 1/2" = `11%0" 1 \,A5 SCALE: 1/2" = 1%0" 1 . SEE COMPONENT AND CLADDING PRODUCT APPROVAL SCAEDULE FOR ASPHALT ROOFING SHINGLE REQUIREMENTS WHICH HAVE BEEN SELECTED TO COMPLY WITH 2020 FBC-RESIDENTIAL, CHAPTER 9, SECTION R905.2, AND CLASSIFIED TO MEET Vult=160 MPH WIND RESISTANT RATING PER TABLE R905.2.6.1 2. INSTALLATION OF ASPHALT SHINGLES SHALL BE NAILED PER SHINGLE MANUFACTURER I SPECIFICATION BUT NO LESS THAN (6) 12 GAUGE x 1j" CORROSION -RESI STAN T ANNULAR RING SHANK ROOFING NAIL PER TAB, OVER ICE AND WATER SHIELD PEEL AND STICK. 3. INSTALLATION OF METAL ACCESSORIES, AND PLACEMENT OF SHINGLES AT INTERSECTIONS, EAVES, VALLEYS, AND GABLES SHALL CONFORM 11-0 2020 FBC ROOF APPLICATION STANDARD RAS No. 115. 4. UNLESS OTHERWISE SHOWN, EXTERIOR CEILINGS OF FRONT PORCH AND REAR PATIO AND SOFFITS SHALL CONSIST OF 7/a" CEME14T STUCCO OVER WIRELATH WITH 11GA.x2" LONG NAILS WITH %" HEAD AT 6" O.C. OVER %" METAL RIB LATH AT 6" O.C. PROVIDE (2) LAYERS OF 15# FELT OVER EACH FRAMING MEMBER. ME7AL 67UD WALL FRAMING NOTES: WEN METAL STUDS ARE SELECTED FOR INTERIOR NON -BEARING PARTIO,. 1. ''ON WALL FRAMING SHALL CONSIST OF COLD -FORMED STEEL MATERIALS AS FOLLOWS: A) 3�" METAL STUD: 3 1/2" (18 GA.) COLD -FORMED STEEL STRUCTURAL C-SECTION PRODUCT DESIGNATION: 350S162-43; 33 KSI, G60 (OR BETTER) B) 3Y2" METAL TRACK: 3 1/2" (20 GA.) COLD -FORMED STEEL STRUCTURAL T-SECTION PRODUCT DESIGNATION 350T137-33; 33 KSI, G60 (OR BETTER) 2. BOTTOM TRACK STUDS SHALL BE FASTENED TO THE CONCRETE FLOOR SLAB WITH POWDER- ACTUATED 0.22 CALIBER (MIN.) SHOT PINS, 1" LONG x 0.300 HEAD DIA. x 0.145 SHANK DIA, NTH 36" DIA. STEEL WASHER. PLACE 1 SHOT PIN AT 16" O.C. STAGGERED FROM SIDE -TO -SIDE OF TRACK, OR EQUAL. 3. ALL METAL STUDS SHALL BE FASTENED TO TOP Alf"'D BOTTOM TRACKS WITH (2) MIN. #8-18 x 4" S.M.S. (i DIA. SHANK x 5/16" HEAD), OR BETTER. 4. METAL STUD TRACK SHALL BE FASTENED TO 2x4 WOOD STUD FRAMING WITH (2) #12-16 x 13/4" HEX WASHER HEAD WOOD SCREWS (OR BETTER). SHOP DRAWINGS APPROVED PRE -FABRICATED WOOD TRUSSES 024" O.C. INSULATION PER ENERGY CODE SIMPSON STRONG -TIE ROO . F C TRUSS LIP TYPE STC (1 CLIP 0 2x4S, 2 CLIPS @ 2x6S, 3 CLIPS 0 2X8S) (NOTE: EQUAL ANCHORS MAY BE SUBSTITUTED) FIRE BLOCKING (SEE NOTE #1) ATTACH P.T. WOOD STUD- 10 CMU WALL WITH )/4" X T' TAPCON AT 24" O.C. VERT. USE .145" DIA P.A.F. @16" O.C. TO CONCRETE WOOD BASE BOARD MOLDING 'RE 1 SIM$ MZWCH��Qam )�" THICK CEILING RATED GYPSUM WALLBOARD SHEATHING (OTHERWISE NON -RATED %" THICK GYPSUM WALLBOARD IS REQUIRED) 2x4 CONT. TOP PLATE OR LIGHT GAUGE METAL I -TRACK WOOD STUDS LIGHT GAUGE METAL C-STUD 2x4S @ 16" O.C. FOR H=10' TO 14' 3 1/2" 0 24" O.C. FOR H=8' TO 10' 2x4S @ 24" O.C. FOR H=8' TO 10' 3 1/2" @ 16" O.C. FOR H=10' TO 14' 2x6S 0 24" O.C. FOR H=10' TO 14' WOOD STUD TO PLATE 2-16d NAILS @ 2x4S 3-16d NAILS 0 2x6S N' GYPSUM WALLBOARD SHEATING P.T. 2X SOLE PLATE OR LIGHT GAUGE I META"' TRACK STUD (SEE NOTE #2) CONCRETE FLOOR SLAB PER PLAN 1. PLACE FIRE BLOCKING CONSISTING OF 2x4 SOLID BLOCKING (OR CODE APPROVED EQUAL) BETWEEN ALL STUDS IN ALL INTERIOR PARTITION WALLS EXCEEDING 10'-0" IN HEIGHT. BLOCKING TO BE PLACED IN A CONTINUOUS ROW AT 8'-0" (+/-) ABOVE FINISHED FLOOR SLAB. 2. INTERIOR PARTITION WALLS CONSTRUCTED WITH LIGHT GAUGE METAL STUD SHALL BE CONSTRUCTED OVER 2X P.T. WOOD PLATE FASTENED AS NOTED IN THIS DETAIL. 3. ATTACH P.T. 2x4 STUD TO ADJACENT CMU WALLS WITH Y4%3" TAPCONS AT 24" O.C. VERT. y: 1116: 11611:1111f ------------ - ----- - - - -------- I I - -BEARING WALL) NINE SCAI-E: 1/2" = V-0" 1 STRAP FOR UPLIFT 1175# 2 STRAPS FOR UPLIFT UP (2) 2x8 P.T. LEDGER BOARD NAILED TOGETHER ------------ -- WITH (2) 16d NAILS 0 20" O.C. (MAX.) AND FASTENED TO MASONRY WALL WITH -3/4"0 WEDGE A,B. x 6" MIN. EMBEDMENT. SET A.B. 6" FROM EACH WALL CORNER AND 24" O.C. MAX. ALONG LEDGER BOARD. ALL A.B. MUST BE SET INTO SOLID GROUTED FILLED MASONRY NOTE: LEDGER BOARD WEDGE ANCHOR BOLT SHALL BE: HILTI KWIK BOLT 3 EXPANSION ANCHOR OR EQUAL INSTALLED WITH HEAVYDUTY WASHER AND HEAVY HEAD NUT. (OR BETTER) SIMPSON H]"SM16 I - 'OMMON PRE-ENGINEERED ROOF TRUSS ONLY) (MISALIGNMENT OF GIRDER TRUSS 'CONNECTOR TO BE APPROVED BY -ENGINEER) ROM REVIEWED FOR CODE COMPLIANCE ST, LUCIE COUNTY 'SCALE. N.T.S. 12 ISLE ELEV. (TYP) 12 SEE ELEV, (TYP) STUCCO OVER WIRELATH WITH 11GA. 2 NAILS w/ " 0 HEAD " O.C. OVER $ BW METAL RIB LATH " O.C, w/(2 LAYERSOFT 15# FELT OVER EACH FRAMING MEMBER). r fr fr f"' i ON (2500 PSI) CONC. FOUNDATION (SEE SHEET —Al FOR SIZES AND 36" SPECIFICATIONS) SEE TYPICAL WALL SECTION FOR ADDITIONAL INFORMATION PRE— ENGINEERED WOOD TRUSSES 0 24" O.C. (MAX. SPACING) "SIMPSON" STRAP PER TRUSS CONNECTOR SCH. (2) ROW 8x8 CONTINUOUS CONCRETE BEAM BLOCK WITH (1)—#5 BAR IN (3000 PSI) CONC. FILLED EACH CELL 8" PRECAST LINTEL WITH (1)—#5 BAR IN (3000 PSI) CONCRETE FILLED CELL (SEE LINTIEL SCHEDULE FOR MORE INFORMATION) 16" X 16" CONCRETE BLOCK COLUMN WITH (4) ®#5 BARS IN (3000 PSI) CONCRETE FILLED CELLS STUCCO FINISH #5 REBAR W/ 330" MIN. LAP SPLICE DE Cv-RATIVE STUCCO BANIDING FINISH_D GRADE (2500 PSI) CONIC, FOUNDA1.110N SEE PLAN FOR SIZES AND SPECIFICATIONS i SEE TYPICAL WALL SECTION FOR ADDITIONAL INFORMATION #5 REBAR w/90'H0OK 5"x8" CONTINUOUS CONC. BEAM BLOCK w/(1) #5 BAR IN (3000 PSI) CONC. FILLED CELL 8"x16"x16" CONCRETE BLOCK COLUMN w/(3) #5 BARS PERT. IN (3000 PSI) CONC. FILLED CELL STUCCO FINISH " THICK -#5 REBAR w/30" MIN. LAP SPLICE to FINAL GRADE SCA,L E. 1.;2,W m 1'-0 e STEEL TRACK BRACKETS TO BE FASTENED TO WOOD 2x6 BUCK w/ PER GARAGE DOOR MANUFACTURER'S SPECIFICATIONS (OR AS NOTED BELOW) OHGd TRACK BRACKETS TO P.T. BUCK 7' HIGH DOOR: (7) 9fr," x 1—%" LONG CORROSION RESISTANT HEX HEAD LAG SCREWS SPACED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. BUCK DETAIL - _ .__ _._ SCALE: N.1°.. STUCCO CEMENT FINISH CORROSION RESISTANT FLASHING — PER WATERPROOFING NOTE #2 APPLY PERIMETER SEALANT CAULK BETWEEN BUCK & WINDOW FRAME (SEE WATERPROOFING NOTE #5) �4 IIIYij STUCCO CEMENT FINISH CMU WATER RESISTANT COATING (SEE WATERPROOFING NOTE #1) CORROSION RESISTANT FLASHING PER WATERPROOFING NOTE #2 NOTE: WINDOW FRAME SHOULD BE COMPLETLY SEATED ON THE BUCK. IN NO INSTANCE SHALL THE FRAME OVERHANG THE BUCK 10 P.T. WOOD FIRRING ALL (3) SIDES CONTINUOUS WOOD TRIM ! ffr 1x3 P.T. WOOD FIRRING ALL (3) SIDES CONTINUOUS SEE WATER PROOFING NOTE #6 P.T. WOOD BUCK WITH SEALANT PER WATERPROOFING VOTE #4 AND ANCHORED TO MASONRY PER BUCK ATTACHMENT NOTE. f r . W: f f ,■, NOTE: WINDOW AND DOOR FENESTRATIONS IN ACCORDANCE WITH FBC R7034 (1,2) AS PER DETAILS PROVIDI-D BUCKS: a FOR WINDOWS, SGD, AND SWING DOORS USE 2X4, 2X6, 2X8, 1X6, 1X8, DOUBLE 1X6, OR DOUBLE. 1X8 IS ACCEPTABLE. 9 ALL BUCKS MUST BE PRESSURE TREATED. 0 ALL BUCKS MUST COVER ENTIRE DEPTH OF THE DOOR/WINDOW JAMB. STUCCO CEMENT FINISH FILLED CELL AT JAMB BLOCK (TYP) t. CMU WATER RESISTANT COATING (SEE WATERPROOFING NOTE #1) a d a• 10 P.T. WOOD FIRRING ALL (3) SIDES CONTINUOUS WOOD TRIM P.T. WOOD BUCK WITH SEALANT PER WATERPROOFING APPLY PERIMETER SEALANT CAULK NOTE #4 AND ANCHORED TO MASONRY PER BUCK BETWEEN BUCK & WINDOW FRAME ATTACHMENT NOTE. (SEE WATERPROOFING NOTE #5) SEE WATERPROOFING NOTE #6 CORROSION RESISTANT FLASHING PER WATERPROOFING NOTE #2 ANCHOR DOOR JAMB AND HEADER TO 2x BUCKS IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCT APPROVAL INSTALLATION REQUIREMENTS. - }- ! * 1, r f♦ r; CORROSION RESISTANT FLASHING PER WATERPROOFING NOTE #2 CAULK SEAM AT WINDOW INSTALLATION (SEE WATERPROOFING NOTE #5) CMU WATER RESISTANT COATING (SEE WATERPROOFING NOTE #1) SET SILL IN FULL MORTAR BED STUCCO OR DECORATIVE CEMENTITIOUS COATING 8" C,M.U. 4" FURRING TO MASONRY WALL .a f f ■ ! • r fir'. f_� r '' « * A M s ,� f r -♦ f ! f � A ♦ r ■: s r .. . w i yW i *-� r wl a +� r♦ r rf♦• �- !i A a r s ■rf 'r f f Z •1 f '' f r rf •'" r a ■■ r !f ,,. BUCK ATTACHMENT: 0 FOR 1 X BUCKS ATTACH 10NiL? WALL WITH; 1 1/2tre LONG CASE HARDENED COIL NAILS AT 4" FROM ENDS AND 12" O.C. OR 3/1C X 1 1/2" TAPCONS AT 4" FROM ENDS AND 12" O,C. OR 1/4- X 1 1/2" TAPCONS AT 4" FROM ENDS AND 12" O.C. • FOR 2 X BUCKS ATTACH TO CMU WALL WITH: 2 1/4" LONG CASE HARDENED COIL NAILS AT 4" FROM ENDS AND 12" O.G., OR 3/16" X 2 1/4" TAPCONS AT 4" FROM ENDS AND 12" O.C. OR 1/4" X 2 1/4" TAPCONS AT 4" FROM ENDS AND 12" O.C. • FOR DOUBLE 1 X BUCKS ATTACH FIRST COURS TO CMU WALL WITH: REVIEWED 1 1/2" LONG CASE HARDENED COIL NAILS AT 4" FROM ENDS AND 12" O.C. ,. . ,. LI AMCE OR CIE COUUTY 3/16" X 1 1/2" TAPCONS AT 4" FROM ENDS AND 12" O.C.' m,' OR 1/4- X 1' 1/2" TAPCONS AT 4" FROM ENDS AND 12" O.C. ATTACH SECOND COURS TO CMU WALL THRU FIRST COURSE WITH: 2 1/4" LONG CASE HARDENED COIL NAILS AT 4" FE�OM ENDS AND 12" O.C. OR 3/16" X 2 1/4" TAPCONS AT 4" FROM ENDS AND 12" O.C. OR 1/4" X 2 1/4" TAPCONS AT 4" FROM ENDS AND 12" O.C. ,gk 9'-4" TYP71 ICAL WALL HEIGHT -OL 7'-4" WINDOW HEADER HEIGHT "IF A7) #5 VERTICAL BARS WALL REINFORCING -7 ABOVE WALL OPENINGS SHALL BE PROVIDED WITH A STD. ACI HOOK TIED -rn I [KlTrl mmkirnDnlkin CTE-C71 tTVDInAl 1 P7 44 4 7L 1,A (MNG IN.) PRECAST CONCRETE LINTEL 8' BEAR (SEE SCHEDULE FOR DESIGNATION AND REBAR REQUIREMENTS) REBAR PLACED IN LINTEL MUST BE CONTINUOUS -NO SPLICING ALLOWED jm. T4 H 2 COURSES OF 8" BOND BEAM BLOCK (CEMEX/RINKER # T81 OR EQ.) ALONG TOP OF ALL WALLS REINFORCED WITH (1) #5 BARS CONTINUOUS IN EACH BLOCK ErT Ll - LINTEL TYPE BF1 6-1 B/1 T SECTION A -A SET PRECAST CONCRETE WINDOW SILL (SEE DETAIL 7, SHEET-A6) OR POUR IN PLACE CONC. SILL W/ (2) #4 BARS EXTENDED 6" INTO EACH SIDE JAMB BLOCK BEFORE GROUTING WALL CAVITIES (OR Dili AND SET WITH 5" EPDXY EMBEDMENT) 8" CMU 13LOCK WALL- REINFORCED AS NOTED ON THE PLANS AND INDICATED IN DETAILS (ALL VERTICAL BARS SHALL BE HOOKED INTO TOP BOND BEAM BLOCK) (1) #5 VERTICAL BARS —TYPICAL AT ALL WALL OPENINGS LESS THAN 8'-0" WIDE ALL OPENINGS 8'-0" WIDE AND LARGER SHALL HAVE (1) #5 BAR IN 2 ADJACENT BLOCK CELLS GROUTED SOLID (SEE PLANS FOR LOCATIONS) 4 IVA 141 k SCALE: N.T.S. n COURSES nr " in 0 BLOC" u ullu r-MM LU (CEMEX/RINKER TYPE T81 OR M) (2)#5 BAR CONTINUOUS EACH LOUR: ALONG TOP OF WALL, FILLED SOLID GROUT HORIZONTAL BOND BEAM BARS WITH STD. 90- ACI HOOK i MINIMUM) (TYPICAL) ELEVATION VIEW #5 REBAR WITH STD. 90' HOOK AT TOP GROUTED SOLID STEPPED BOND BEAM DETAIL CMU WALL DETAIL a. ENTRANCE WAY FIELD CUT LINTELS TO MITER END AND CUT BOTTOM TO ALLOW EXTENSION OF 3 COLUMN VERTICAL BARS THROUGH LINTEL (1) #5 REBAR CONT ALONG TOP OF BEAM S2 0 _j m 00 Z z < EB (L #5 REBAR AT BOTTOM GROUT SOLID (3000 psi) 8" BOND BEAM BLOCK (CEMEX/RINKER # T81 OR EQUAL) #2 STIRRUP (ACI TYPE Sl) a 8., O.C. 3/4" CLEAR OFF LINTEL CAVITY o 8" PRECAST LINTEL LINTEL TYPE BF16-18/1T MODIFIED AS SHOWN SCALE: N.T.S. OIL 9'-4" TYPICAL WALL HEIGHT T 8'-0" WINDOW HEADER HEIGHT "IF #5 VERTICAL BARS WALL REINFORCING ABOVE WALL OPENINGS SHALL BE PROVIDED WIT11 A STD. ACI HOOK TIED TO LINTEL REINFORCING STEEL (TYPICAL) I �A T 4 • A A 7177 7 . 1! .4 a. 4 zw 7 . ' =4q L! A PRECAST CONCRETE LINTEL (SEE SCHEDULE FOR DESIGNATION BEARING ��A'u AND REBAR REQUIREMENTS) REBAR PLACED IN LINTEL MUST BE L L., CONTINUOUS —NO SPLICING ALLOWED REINFORCEMENT PLAC: — - ------------- - oil Lill oil 2 COURSES OF 8" BOND BEAM BLOCK (CEMEX/RINKER # T81 OR EQ.) ALONG TOP OF ALL WALLS REINFORCED WITH (1) #5 BARS CONTINUOUS IN EACH BLOCK LINTEL TYPE 81`16-18/1 T SECTION A -A SET PRECAST CONCRETE WINDOW SILL (SEE DETAIL 7, SHEET—Aii OR POUR IN PLACE CONC. SILL W/ (2) #4 BARS EXTENDED 6" INTO EACH SIDE JAMB BLOCK BEFORE GROUTING WALL CAVITIES (OR DRILL AND SET WITH 5" EPDXY EMBEDMENT) 8 CMU BLOCK WALL— REINFORCED AS NOTED ON THE PLANS AND INDICATED IN DETAILS (ALL VERTICAL BARS SHALL BE HOOKED INTO TOP BOND BEAM BLOCK) (1) #5 VERTICAL BARS -TYPICAL AT ALL WALL OPENINGS LESS THAN 8'-0" WIDE ALL OPENINGS 8'-0" WIDE AND LARGER SHALL HAVE (1) #5 BAR IN 2 ADJACENT BLOCK CELLS GROUTED SOLID (SEE PLANS FOR LOCATIONS) ff-ml 0.9p- A -9- lk A A I El 0 A '.A.te IL & 9 r m —a . . a . — — 0— — - — — - - - SCALE. N.T.S. REVIEWEED FOR fw-OMPLIANCF, DRAFTING SERVICES 10ANJAFFIR, L C PHONE: (772) 237-7942 W WW TREASURECOASTDRAPTING.COM rl u z u 0 occ� c) 040 0 Z Q�IHz o It cq u �0�W 0 1:4 U uj U) 00 0) rn (N > -, r-, z a- j u :n uj Lu w Ln u u 00 0 =) 0 N LL_ _j _j — C6 i - � 'r, Z 00 LLI Lr) r4 u./ LA Date: SCALE. N.T.S. JOB No: 520-1072 A7 ELECTRIC LOAD l".;`AL.C"S PER NEC 1660 sq. ft. x 3VA (GENERAL LIGHTING) 4,980 VA GARBAGE DISPOSAL N/A REFRIGERATOR 1,200 MICROWAVE 1,500 DISHWASHER 1,800 RANGE/OVEN 12,000 DRYER 5,000 WASHER 1,200 WATER HEATER 5,000 OPT. POOL PUMP 1,500 OPT. POOL HEATER 6,000 OPT. WELL PUMP 2,000 OPT. IRRIGATION PUMP 2,000 misc. 10,000 TOTAL 54,180 VA FIRST 10 KW 0100% 10,000 REMAINDER 040% 17,672 TOTAL 27 A/C HEAT 0 100% TOTAL 37,6VIA TOTAL/240V 15-/ ............ EXHAUST VENT THRU'SOFFIT EXHAUST VENT THRU'ROOF SWITCH $ DIRECT WIRE LIGHT FIXTURE 3 �- H WAY SWITC- THERMOSTAT (D CEILING MOUNTED LJ 4-WAY SWITCH 3 PHONE/CAT5 PH c!5 T LIGHT FIXTURE w/PULL SWITCH DIMMER SNTCH o TV JACK 1 20V OUTLET SMOKE DETECTOR & HI HAT HALF HOT OUTLET CARBON MONOXIDE VAPOR PROOF Fill HAT DETECTOR 220V OUTLET EXHAUST FAN , FLOOD LIGHT >8 Gr' CIUTLET PUSH BUTTON W'P -DPI OUTLET DOOR CHIMES ff—"5 CEILING Wo Wo ALARM PAD FAN with LIGHT QUAD OUTLET PANEL FUSE DISCONNFC- METER # POLES FRAME SILE- FUSE SIZE FIGHTLUORESCENT INEMA ENCLCSURF? 'L FANCEILING G� GARAGE DOOR - SPEAKER FINIE R BOX LIGHT FIXTURE Julw_'TION WALL MOUNTED SARBAG7E DISP, ABOVE FINISHED FLOOR AFF ECTRI,CAL NOTES: SMOKE DEFLOJORS TO BE 110V wl BAT 7,11''ERY BACK UP -ARC FAULT CIRCUIT. SMOKE DETECTORS TO BE LOCATED AS SHOWN. SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE. PROVIDE ARC -FAULT PROTECTION FOR ALL BRANCH CIRCUIT OUTLETS, PER N.E.C. 21012 EXHAUST FANS TO BE VENTED THRIJ ROOF OR SOFFIT. PROVIDE PHONE AND TV OUTLETS, VERIFY LOCATIONS. MICROWAVE OUTLET TO HAVE DEDICATED CIRCUIT. ALL BATH., GARAGE, KITCHEN, AND EXTERIOR OUTLETS WHERE NOTED TO HAVE GROUND FAULT INTERRUPT. PROVIDE LEGIBLE DIRECTORY AT PANEL INDICATING INDIVIDUAL CIRCUITS. ALL WORK SHALL COMPLY WITH ALL LOCAL STATE AND NATIONAL CODES. CARBON MONOXIDE DETECTORS TO BE INSTALLED WITHIN 10' FROM ALL BEDROOMS. PROVIDE TAMPER RESISTANT RECEPTACLES PER N.E.C. 406.11. RUN CONDUIT WITH PULL STRING FOR FUTURE POOL EQUIPMENT. CONTACT WINDOW MANUFACTURER ABOUT REQUIREMENTS TO MEET THE SHGC & U FACTOR. THE SHGC AND U FACTOR TO BE COORDINATED WITH ENERGY CALCULATIONS PROVIDED TO MEET ENERGY CODES -REQUIRED. C, �� �.�ERHEAD SERVICE FROM FPL 2" RGS OR 2" RGS SERVICE IMC CONDUIT DETERMINED BY POWER COMPANY +1)2;/03/0W/2 #3-'0THHN + 0 cu CU) CU CU OR EQUAL METER IER (MIN RATING--10,000 A/C --------- INTERRUPTING) #4 SOLID COPPER GROUND TO 5/8"x2O'-O" REBAR EMBEDDED IN FOUNDATION (OR NEC EQUAL) i 200 AMP PANEL — MAIN BREAKER 40 CIRCUIT. 2 MOLE, 1 PHASE � 00 AMP DISC'. R— Eo'QUIRED FOR X XT TENDED SERVICE ONLY) ........... . mro GROUND TO 5/8"x2O'--O" REEBA EMBEDDED IN FOUNDATION (OR NEC EQUAL) 4:10 REVIEWED FOR cOn P E CM WILIANCE -TRICAL Rl'-_r__R ABOVE GROUND ELE' "'AL RI] _R UNDERGR' 9UND ELEC G" UNTY 120/240 V, 1 PHASE, 3 WIRE SERVICE t-�,10 SCAL120/240 V, 1 PHASE, -, 3 WIRE SERVICE N0 SCALE 0 1-1 DRAFTING SERVICES roAN JA&'Ez , IA.0 PHONE: C772) 237-7942 W'WW.TRRASURECOASTDRAFTTNT(5,COM -4 z u z u z 0 u z LO CIA u 0 0 rA 174 U 0 L) 0 u Lu m ul) 00 cr) Li In 'm ■ V) > I _ 0 ad Z coi LjLn W cr- W LLJ Ln 00 D U U, r'4 0 ILL =) D -j -j 06 F-�- V) U) rs Z Lj '� 0 uj 00 *0 a- M Llj Ill Ln '000, Ln f14 Date: SCALE; 1/4" JOEI No: 520-1072 55' 0" TRUSS BEARING ID POINT A13 A C4, C , C6 B B4 C ALL OTHERS AT CBS EACH BEARIc'x� r RS AT THANt E EACH TRUSS ACTUAL 1 UPLIFT <2000# <450# CONNECTOR ID I (1)—MGT (1)—LUS28 CONNECTOR UPLIFT FASTENERS DESIGN 3965# (1) 5/8" THRD. ROD EPDXIED 7" MIN. & (22)-10d 1165# (10)-10d NOTES AT CBS BEARING AT LEDGER ui w.j xuc M JD1 t <1350# <1730# (1)—HTS20 (1)—HETA12 1450 (4)-10d x 1 1/2" 1730# (7)-16d AT FRAME BEARING AT CBS BEARING <1000 (1)-MTS 16 1000# (14)-10d x 1 1/2"" AT F' E BE ING 0 NOTE: ALL STRAPPING TO BE SIMPSON STRONG -TIE AS SPECIFIED NOTES: ; �+, VALLEY TRUSSES MAY BE ATTACHED WITH SIMPSON VTCR w/(4)-#9 SD x 232" TO SUPPORTING TRUSS AND ()-#9 SD x 1%2" TO VALLEY TRUSS IN LIEU OF MTS16 AS STATER. VTCR SHALL BE INSTALLED AT EACH END AND 24" O.C. D 0 USE SIMPSON EPDXY STRONG TEE SYSTEM H 12" MIN. EMBEDMENT FOR ANCHOR BOLTS (A.B.). TRUSS NOTES: D1 1. ALL ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANY'S ENGINEER. D1 2. CONTRACTOR TO PROVIDE ENGINEER, AND BUILDING DEPARTMENT WITH ENGINEERED TRUSS DRAWINGS BEFORE INSTAI TRUSSES. . CONTRACTOR TO VERIFYROOF CONDITIONS, DIMENSIONS BEFORE ORDERING, INSTALLING TRUSSES. A /2 J1 4. TRUSS TO TRUSS CONNECTION TO BE PROVIDED BY TRUSS COMPANY. 5. SEE TRUSS CONNECTOR SCHEDULE FOR TRUSS TO WALL CONNECTIONS. 111KNUM 1422- 1,11011111 DESIGN1. REACTIONS .: HAVE BEEN DETERMINED AND PROVIDED w#'..:1 iR BY TRUSS MANUFACTURER'S r SHOP DRAWINGS (BUILDERS ' OR JOB NO. r 6.. LAYOUTDATE 1 #:". CUT -SHEET DATE: 03/05/21 AND REVIEWED BY THIS STRUCTURAL ENGINEER FOR DETERMINA11ON OF THE TRUSS CONNECTOR TYPE AND ALLOWABLE LOADS NOTED IN THE TRUSS TO WALL OUV V1 e a . r : y y.. # r r21 RRFA ONE •_ 1. y . r ! • c ..,l • # M 1 - : 3. ALL TRUSS TO PERIMETER 8" CMU WALL CONNECTORS SHALL BE META 12• UNLESS DESIGNATED OTHERWISE ON THE ROOF FRAMING PLAN. 4. MINIMUM 4" EMBEDMENT WITH MINIMUM EDGE DISTANCE OF 2" REQUIRED rOR META STRAPS CAST —IN —PLACE. 5. TRUSS ANCHOR --META 16 STRAP SHALL BE PROVIDED WITH "TSS" MOISTURE BARRIER SEAT. 6. ANCHORS, HANGERS, AND TIE STRAPS AS SHOWN IN THE ABOVE SCHEDULE ARE IDENTIFIED ON THE ROOF FRAMING PLAN. SUBSTITUTION OF APPROVED EQUAL OR BETTER ANCHORS" HANGERS AND TIE STRAPS FOR THE SPECIFIED ALLOWABLE LATERAL & UPLIFT LOADS ARE ACCEPTABLE. 7. THE SIMPSON STRONG —TIE CONNECTOR ALLOWABLE LOAD VALUES SHOWN IN THE ABOVE SCHEDULE ARE THE C-2018 PUBLISHED VALUES BASED ON WOOD TRUSSES FABRICATED USING SOUTHERN YELLOW PINE AND INCLUDE AN APPLIED 1/3 STRESS INCREASE FOR WIND LOAD DURATION ONLY, IN ACCORDANCE WITH NDS ALLOWABLE STRESS DESIGN PERMITTED FOR WOOD OR FASTENERS IN WOOD. 8. PROVIDE SUITABLE PRE —FORMED OR LIQUID APPLIED MOISTURE BARRIER BETWEEN BOTTOM CHORD OF ROOF TRUSS AND TOP OF MASONRY WALLS, WHEN BARRIER IS NOT PROVIDED WITH TRUSS CONNECTOR. f M ' r � f. '. � r . � r. g . r s. � 1 . �',. � 1: A I� 1: 1 � 1 i .' 1 'r r i #: � # .1 �, r... : :. r ♦ , r : .. DRILL HOLE DIA. (MAX.) IXG"" //%%i n in EMBEDMENT DEPTH (MIN. 12P 1291 PLYWOOD SH11EATHI G NAILING SCHEDULE -------------------- LOCATION NAIL SIZE/TYPE EDGE FIELD NOTES SPACING SPACING WALL Z SHEATHING 0 ALL 6d COMMON 6" O.C. 6" O.C. (15/32"°) N WALL ZONES E r� 0 @ 8d Ring Shank 4" O.C. 4" O.C. (OVERHANGS) Z ROOF SHEATHING (19/32") O 2 N 8d RingShank 4" O.C. 6" O.C. E 8d Ring Shank 6" O.C. 6" O.C. f RING-SHANKNAILS SHALL HAVE THE FOLLOWING 1. 0.113-INCH NOMINAL DIAMETER 3. 16 To 20 RINGS 2. RING DIAMETER OF 0.012 OVER SHANK DIAMETER INCHES 4. 0.280 INCH FULL ROUND ' M DIAMETER 5. 2-INCH NAIL LENGTH Hatch Legend 12 =0" A.F.Fl =4" AmFmF 11 #.� NAILS ZONE AT D.C. PERIMETER . r AND " D.C.FIELD ZONE NAILSO.C.PERIMETERAND r O.C.1 O NAILS AT O.C.PERIMETER .r AND r O.C. FIELD NOTE ij� DRAP'PING SERVICES JOAN JAFP6, I I.0 PHONE, (772) 237-7442 W W W.TRHASURECOASTDRAFTINO.COM � a a z N w U w a A A U 0 F-� U 14 I—i H A Q A d z rV� A N N O h�j ® 0 V)UO° ®®z�N w F+�I Q 0 V N W ® ,Z H U)rn Cq h J W Ln CIOLL C" Uj H V7 h_q O J J N W N v Ce 00 V1 a a w uJ Ln Ln n Date: SCALE: 1/41" = 1"-01" JOB No: 520-1072 R 1