HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Rudy Rodriguez Residence
Builder Name:
Street: 3110 -10M S. 22nd Street
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL , 34982
Permit Number:
Owner: Rudy Rodriguez
Jurisdiction: St. Lucie County
Design Location:, FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Typeo1608.6 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1421.90 ft2
b. Frame - Wood, Adjacent
R=11.0 186.67 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
11. Ceiling Types (1660.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1660.00 ft2
6. Conditioned floor area above grade (ft2) 1660
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(172.9 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
R ft2
6 75
a. U-Factor: Sgl, U=1.05 172.88 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
36.0, SEER:15.50
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 2.229 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.250
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): , N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1660.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1660.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
CF, Pstat
Glass/Floor Area: 0.104 Total Proposed Modified Loads: 51.92
PASS
Total Baseline Loads: 53.79
I hereby certify that the plans and specifications covered by
this in the Florida Energy
Review of the plans and
by
p 'tRE S .Q?�
calculation are compliance with
specifications covered this
Code.
calculation indicates compliance
van
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 10-18-2 211
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
t t St
FloridaStatutes.
with the Florida Energ ode.
OWNER/AGENT: O�
BUILDING OFFICIAL:
DATE: '- -' a
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
10/18/2021 3:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INrU I bUMMAKT tL#MM%.1%L10I r«rVMI
PROJECT
Title: Rudy Rodriguez Residence
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1660
Lot #
Owner Name: Rudy Rodriguez
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
TBD S. 22nd Street
Permit Office: St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: St. Lucie County
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type: Detached
FL, 34982
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating Design Daily Temp
v Design Location TMY
Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1660 15604
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 M Bath 136
1278.4 No
0
1
Yes
Yes
Yes
2 WIC 1 35
329 No
0
1
Yes
Yes
Yes
3 WIC 2 35
329 No
0
1
No
Yes
Yes
4 Master Suite 224
2105.6 No
2
1
1
Yes
Yes
Yes
5 Kitchen 273
2566.2 Yes
2
1
Yes
Yes
Yes
6 Great Room 483
4540.2 No
2
1
Yes
Yes
Yes
7 Laundry 42
394.8 No
0
1
No
Yes
Yes
8 Bedroom 3 168
1579.2 No
1
1
1
Yes
Yes
Yes
9 Bath 2 72
676.8 No
0
1
Yes
Yes
Yes
10 Bedroom 2 168
1579.2 No
1
1
1
Yes
Yes
Yes
11 Hall 24
225.6 No
0
1
No
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
M Bath _ 26 ft
136 ft2
___
1 0
0
2Slab-On-Grade Edge Insulatio
WIC 1 7 ft
35 ft2
1 0
0
3 Slab -On -Grade Edge Insulatio
WIC 2 1 ft
35 ft2
1 0
0
4 Slab -On -Grade Edge Insulatio
Master Suite 16 ft
224 ft2
1 0
0
5 Slab -On -Grade Edge Insulatio
Kitchen 21 ft
273 ft2
_-__
1 0
0
6 Slab -On -Grade Edge Insulatio
Great Room 21 ft
483 ft2
___
1 0
0
10118/2021 3:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
wrwAMT
FORM R405-2020 INrU I ,UIVIIIIIIAKT lirlr-ILP L101 RGrWMI
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
7 Slab -On -Grade Edge Insulatio Laundry 1 ft
42 ft2
___
1
0
0
8 Slab -On -Grade Edge Insulatio Bedroom 3 26 ft
168 ft2
____
1
0
0
9 Slab -On -Grade Edge Insulatio Bath 2 8 ft
72 ft2
1
0
0
10SIab-On-Grade Edge Insulatio Bedroom 2 26 It
168 ft2
-___
1
0
0
11SIab-On-Grade Edge Insulatio Hall 1 ft
24 ft2
1
0
0
ROOF
/
Roof
Gable
Roof
Red
Solar
Absor.
SA Emitt
Tested
Tested
Emitt Deck
Insul.
Pitch
(deg)
v
# Type Materials Area
Area
Color
Barr
1 Hip Composition shingles 1798 ft2
0 ft2
Medium
N
0.6
No 0.9
No 0
22.62
ATTIC
V
# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
300
1660 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented) M Bath
30
Blown
136 ft2
0.1
Wood
2 Under Attic (Vented) WIC 1
30
Blown
35 ft2
0.1
Wood
3 Under Attic (Vented) WIC 2
30
Blown
35 ft2
0.1
Wood
4 Under Attic (Vented) Master Suite
30
Blown
224 ft2
0.1
Wood
5 Under Attic (Vented) Kitchen
30
Blown
273 ft2
0.1
Wood
6 Under Attic (Vented) Great Room
30
Blown
483 ft2
0.1
Wood
7 Under Attic (Vented) Laundry
30
Blown
42 ft2
0.1
Wood
8 Under Attic (Vented) Bedroom 3
30
Blown
168 ft2
0.1
Wood
9 Under Attic (Vented) Bath 2
30
Blown
72 ft2
0.1
Wood
10 Under Attic (Vented) Bedroom 2
30
Blown
168 ft2
0.1
Wood
11 Under Attic (Vented) Hall
30
Blown
24 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
_ 1
N Exterior Concrete Block - Int Insul M Bath
4.1 3
0 9
5
28.3 ft2
0
0
0.4
0
_ 2
S Exterior Concrete Block - Int Insul M Bath
4.1 9
0 9
5
84.8 ft2
0
0
0.4
0
_ 3
W Exterior Concrete Block - Int Insul M Bath
4.1 14
0 9
5
131.8 ft2
0
0
0.4
0
_ 4
S Exterior Concrete Block - Int Insul WIC 1
4.1 7
0 9
5
65.9 ft2
0
0
0.4
0
_ 5
S Exterior Concrete Block - Int lnstMaster Suite
4.1 16
0 9
5.
150.7 ft2
0
0
0.4
0
_ 6
W Exterior Concrete Block - Int Insul Kitchen
4.1 21
0 9
5
197.8 ft2
0
0
0.4
0
_ 7
E Exterior Concrete Block - Int InsLffireat Room
4.1 21
0 9
5
197.8 ft2
0
0
0.4
0
8
N Exterior Concrete Block - Int InsuBedroom 3
4.1 14
0 9
5
131.8 ft2
0
0
0.4
0
10/18/2021 3:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPHT SHMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity ity Width
Height
Sheathing Framing Solar
Below
#
Omt
In
Wall Type
Et
In Et
In
Aran
R-Vallle
Fraction Ahqnr
Gra 0
9
W
Exterior
Concrete Block - Int InsuBedroom 3
4.1 12
0 9
5
113.0 ftz
0
0
0.4
0
10
N
Exterior
Concrete Block- Int Insul Bath 2
4.1 8
0 9
5
75.3 ftz
0
0
0.4
0
11
N
Exterior
Concrete Block - Int InsuBedroom 2
4.1 14
0 9
5
131.8 ftz
0
0
0.4
0
12
E
Exterior
Concrete Block - Int InsuBedroom 2
4.1 12
0 9
5
113.0 ftz
0
0
0.4
0
_ 13
E
Garage
Frame - Wood
Master Suite
11 7
9
4
65.3 ftz
0.23
0.4
0
14
S
Garage
Frame - Wood
Laundry
11 6
9
4
56.0 ftz
0.23
0.4
0
15
E
Garage
Frame - Wood
Laundry
11 6
9
4
56.0 ftz
0.23
0.4
0
16
S
Garage
Frame - Wood
Great Room
11 1
9
4
9.3 ftz
0.23
0.4
0
DOORS
#
Omt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated
Great Room
None
.39
3
8
24 ftz
2
E
Insulated
Laundry
None
.39
2
8
8
21.3 ftz
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Omt ID
Frame Panes
NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
S 2
Metal Low-E Single
Yes
1.05 0.25
Y
6.9 ftz
1 ft 4 in
1 It 4 in
None
None
2
W 3
Metal Low-E Single
Yes
1.05 0.25
Y
12.0 ftz
1 ft 4 in
1 ft 4 in
None
None
3
S 5
Metal Low-E Single
Yes
1.05 0.25
Y
30.0 ftz
1 ft 4 in
1 ft 4 in
None
None
4
W 6
Metal Low-E Single
Yes
1.05 0.25
Y
24.0 ftz
1 ft 4 in
1 ft 4 in
None
None
5
W 6
Metal Low-E Single
Yes
1.05 0.25
Y
12.3 ftz
1 ft 4 in
1 ft 4 in
None
None
6
E 7
Metal Low-E Single
Yes
1.05 0.25
Y
22.5 ftz
6 ft 0 in
1 ft 4 in
None
None
7
E 7
Metal Low-E Single
Yes
1.05 0.25
Y
10.7 ftz
6 ft 0 in
1 ft 4 in
None
None
8
W 9
Metal Low-E Single
Yes
1.05 0.25
Y
22.5 ftz
1 ft 4 in
1 ft 4 in
None
None
9
N 10
Metal Low-E Single
Yes
1.05 0.25
Y
9.5 ftz
1 ft 4 in
1 ft 4 in
None
None
10
E 12
Metal Low-E Single
Yes
1.05 0.25
Y
22.5 ftz
1 ft 4 in
1 ft 4 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
598 ftz 598 ftz
20 ft
9.4 It
11
INFILTRATION
#
Scope
Method
SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse, Proposed ACH(50) .000298 1300.3 71.34
133.93
.0963
5
10/18/2021 3:14 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6
FnRM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat/
None
COP:1
27 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15.5 36 kBtu/hr
1080 cfm
0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubTpe
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
— Supply —
— Return ---
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic 6 75 ft2
Attic
15 ft2 Default Leakage
Garage
(Default) (Default)
1 1
TEMPERATURES
t:Y
Programable ThermostaH
Ceiling Fans:
Heating Jan Feb Mar
[ j
L1 Apr
X]
May ] Jun Jul
Aug
4 Sep
[ ] Oct Nov
L Oct Nov
Dec
Venting Jan Feb Mar
lxl
1 Jun Jul
Aug
[ Sep
Lx� X
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7-
8
9
10 11
12
Cooling (WD) AM 78
78 78
78 78 78
78
78
80
80 60
80
PM 80
80 78
78 78 78
78
78
78
78 78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78
78
78 78
78
PM 78
78 78
78 78 78
78
78
78
78 78
78
Heating (WD) AM 66
66 66
66 66 68
68
68
68
68 68
68
PM 68
68 68
68 68 68
68
68
68
68 66
66
Heating (WEH) AM 66
66 66
66 66 68
68
68
68
68 68
68
PM 68
68 68
68 68 68
68
68
68
68 66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
M Bath
13efault(8lbs/sq.ft.
ft2
ft
0.3
WIC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Suite
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Great Room
Default(8 Ibs/sq.ft,
ft2
ft
0.3
Laundry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 3
10/18/2021 3:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
W05-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2
Default(8 Ibs/sa.ft. ft2 ft 0.3 Hall
10/18/2021 3:14 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6