Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Rudy Rodriguez Residence Builder Name: Street: 3110 -10M S. 22nd Street Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL , 34982 Permit Number: Owner: Rudy Rodriguez Jurisdiction: St. Lucie County Design Location:, FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Typeo1608.6 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1421.90 ft2 b. Frame - Wood, Adjacent R=11.0 186.67 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Types (1660.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1660.00 ft2 6. Conditioned floor area above grade (ft2) 1660 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(172.9 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft2 6 75 a. U-Factor: Sgl, U=1.05 172.88 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 36.0, SEER:15.50 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 2.229 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): , N/A a. Electric Cap: 50 gallons 9. Floor Types (1660.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1660.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits CF, Pstat Glass/Floor Area: 0.104 Total Proposed Modified Loads: 51.92 PASS Total Baseline Loads: 53.79 I hereby certify that the plans and specifications covered by this in the Florida Energy Review of the plans and by p 'tRE S .Q?� calculation are compliance with specifications covered this Code. calculation indicates compliance van with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 10-18-2 211 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance t t St FloridaStatutes. with the Florida Energ ode. OWNER/AGENT: O� BUILDING OFFICIAL: DATE: '- -' a DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 10/18/2021 3:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INrU I bUMMAKT tL#MM%.1%L10I r«rVMI PROJECT Title: Rudy Rodriguez Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1660 Lot # Owner Name: Rudy Rodriguez Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: TBD S. 22nd Street Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34982 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1660 15604 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M Bath 136 1278.4 No 0 1 Yes Yes Yes 2 WIC 1 35 329 No 0 1 Yes Yes Yes 3 WIC 2 35 329 No 0 1 No Yes Yes 4 Master Suite 224 2105.6 No 2 1 1 Yes Yes Yes 5 Kitchen 273 2566.2 Yes 2 1 Yes Yes Yes 6 Great Room 483 4540.2 No 2 1 Yes Yes Yes 7 Laundry 42 394.8 No 0 1 No Yes Yes 8 Bedroom 3 168 1579.2 No 1 1 1 Yes Yes Yes 9 Bath 2 72 676.8 No 0 1 Yes Yes Yes 10 Bedroom 2 168 1579.2 No 1 1 1 Yes Yes Yes 11 Hall 24 225.6 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio M Bath _ 26 ft 136 ft2 ___ 1 0 0 2Slab-On-Grade Edge Insulatio WIC 1 7 ft 35 ft2 1 0 0 3 Slab -On -Grade Edge Insulatio WIC 2 1 ft 35 ft2 1 0 0 4 Slab -On -Grade Edge Insulatio Master Suite 16 ft 224 ft2 1 0 0 5 Slab -On -Grade Edge Insulatio Kitchen 21 ft 273 ft2 _-__ 1 0 0 6 Slab -On -Grade Edge Insulatio Great Room 21 ft 483 ft2 ___ 1 0 0 10118/2021 3:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 wrwAMT FORM R405-2020 INrU I ,UIVIIIIIIAKT lirlr-ILP L101 RGrWMI FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 7 Slab -On -Grade Edge Insulatio Laundry 1 ft 42 ft2 ___ 1 0 0 8 Slab -On -Grade Edge Insulatio Bedroom 3 26 ft 168 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulatio Bath 2 8 ft 72 ft2 1 0 0 10SIab-On-Grade Edge Insulatio Bedroom 2 26 It 168 ft2 -___ 1 0 0 11SIab-On-Grade Edge Insulatio Hall 1 ft 24 ft2 1 0 0 ROOF / Roof Gable Roof Red Solar Absor. SA Emitt Tested Tested Emitt Deck Insul. Pitch (deg) v # Type Materials Area Area Color Barr 1 Hip Composition shingles 1798 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1660 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) M Bath 30 Blown 136 ft2 0.1 Wood 2 Under Attic (Vented) WIC 1 30 Blown 35 ft2 0.1 Wood 3 Under Attic (Vented) WIC 2 30 Blown 35 ft2 0.1 Wood 4 Under Attic (Vented) Master Suite 30 Blown 224 ft2 0.1 Wood 5 Under Attic (Vented) Kitchen 30 Blown 273 ft2 0.1 Wood 6 Under Attic (Vented) Great Room 30 Blown 483 ft2 0.1 Wood 7 Under Attic (Vented) Laundry 30 Blown 42 ft2 0.1 Wood 8 Under Attic (Vented) Bedroom 3 30 Blown 168 ft2 0.1 Wood 9 Under Attic (Vented) Bath 2 30 Blown 72 ft2 0.1 Wood 10 Under Attic (Vented) Bedroom 2 30 Blown 168 ft2 0.1 Wood 11 Under Attic (Vented) Hall 30 Blown 24 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 N Exterior Concrete Block - Int Insul M Bath 4.1 3 0 9 5 28.3 ft2 0 0 0.4 0 _ 2 S Exterior Concrete Block - Int Insul M Bath 4.1 9 0 9 5 84.8 ft2 0 0 0.4 0 _ 3 W Exterior Concrete Block - Int Insul M Bath 4.1 14 0 9 5 131.8 ft2 0 0 0.4 0 _ 4 S Exterior Concrete Block - Int Insul WIC 1 4.1 7 0 9 5 65.9 ft2 0 0 0.4 0 _ 5 S Exterior Concrete Block - Int lnstMaster Suite 4.1 16 0 9 5. 150.7 ft2 0 0 0.4 0 _ 6 W Exterior Concrete Block - Int Insul Kitchen 4.1 21 0 9 5 197.8 ft2 0 0 0.4 0 _ 7 E Exterior Concrete Block - Int InsLffireat Room 4.1 21 0 9 5 197.8 ft2 0 0 0.4 0 8 N Exterior Concrete Block - Int InsuBedroom 3 4.1 14 0 9 5 131.8 ft2 0 0 0.4 0 10/18/2021 3:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPHT SHMMARY CHECKLIST REPORT WALLS Adjacent Cavity ity Width Height Sheathing Framing Solar Below # Omt In Wall Type Et In Et In Aran R-Vallle Fraction Ahqnr Gra 0 9 W Exterior Concrete Block - Int InsuBedroom 3 4.1 12 0 9 5 113.0 ftz 0 0 0.4 0 10 N Exterior Concrete Block- Int Insul Bath 2 4.1 8 0 9 5 75.3 ftz 0 0 0.4 0 11 N Exterior Concrete Block - Int InsuBedroom 2 4.1 14 0 9 5 131.8 ftz 0 0 0.4 0 12 E Exterior Concrete Block - Int InsuBedroom 2 4.1 12 0 9 5 113.0 ftz 0 0 0.4 0 _ 13 E Garage Frame - Wood Master Suite 11 7 9 4 65.3 ftz 0.23 0.4 0 14 S Garage Frame - Wood Laundry 11 6 9 4 56.0 ftz 0.23 0.4 0 15 E Garage Frame - Wood Laundry 11 6 9 4 56.0 ftz 0.23 0.4 0 16 S Garage Frame - Wood Great Room 11 1 9 4 9.3 ftz 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Great Room None .39 3 8 24 ftz 2 E Insulated Laundry None .39 2 8 8 21.3 ftz WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 2 Metal Low-E Single Yes 1.05 0.25 Y 6.9 ftz 1 ft 4 in 1 It 4 in None None 2 W 3 Metal Low-E Single Yes 1.05 0.25 Y 12.0 ftz 1 ft 4 in 1 ft 4 in None None 3 S 5 Metal Low-E Single Yes 1.05 0.25 Y 30.0 ftz 1 ft 4 in 1 ft 4 in None None 4 W 6 Metal Low-E Single Yes 1.05 0.25 Y 24.0 ftz 1 ft 4 in 1 ft 4 in None None 5 W 6 Metal Low-E Single Yes 1.05 0.25 Y 12.3 ftz 1 ft 4 in 1 ft 4 in None None 6 E 7 Metal Low-E Single Yes 1.05 0.25 Y 22.5 ftz 6 ft 0 in 1 ft 4 in None None 7 E 7 Metal Low-E Single Yes 1.05 0.25 Y 10.7 ftz 6 ft 0 in 1 ft 4 in None None 8 W 9 Metal Low-E Single Yes 1.05 0.25 Y 22.5 ftz 1 ft 4 in 1 ft 4 in None None 9 N 10 Metal Low-E Single Yes 1.05 0.25 Y 9.5 ftz 1 ft 4 in 1 ft 4 in None None 10 E 12 Metal Low-E Single Yes 1.05 0.25 Y 22.5 ftz 1 ft 4 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 598 ftz 598 ftz 20 ft 9.4 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse, Proposed ACH(50) .000298 1300.3 71.34 133.93 .0963 5 10/18/2021 3:14 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FnRM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15.5 36 kBtu/hr 1080 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply — — Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 75 ft2 Attic 15 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES t:Y Programable ThermostaH Ceiling Fans: Heating Jan Feb Mar [ j L1 Apr X] May ] Jun Jul Aug 4 Sep [ ] Oct Nov L Oct Nov Dec Venting Jan Feb Mar lxl 1 Jun Jul Aug [ Sep Lx� X Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7- 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 60 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 M Bath 13efault(8lbs/sq.ft. ft2 ft 0.3 WIC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Suite Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Great Room Default(8 Ibs/sq.ft, ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 10/18/2021 3:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 W05-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sa.ft. ft2 ft 0.3 Hall 10/18/2021 3:14 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6